DS3/STS-1 Repeater Products

Similar documents
Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

FOM-9010, FOM-9011 and FOM-9012

Instruction Manual Model BlockUpconverter

Model /29S RF Splitter

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

High Density Optical Platform for FTTx and HFC

Broadband Connectivity System II

7000 Series RossGear Series RossGear

ex 800 Series ematrix System

BCS 4R DSX-3 Connectivity System. Models , , and User Manual

Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs!

Video Patching Systems ProPatch Miniature (PPM) Series

Instruction Manual Model # Block Upconverter

HighBand 25. TrueNet Category 6 Solutions

MODULO - HFC YOUR SMART HFC HEADEND TOOLKIT UNIVERSAL, SMART AND EASY - DON T MISS IT THE ART OF ENGINEERING

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation

DSX-1 Cross-Connect Procedures

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

Video Digital Optical Converter

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

The UTAH-300 and its Smart Architecture UTAH-300. Routing System. the optimal balance between rackframe density

Traditional RF Splitter/Combiner and Directional Coupler User Manual

HI-DEX PRODUCT SET DATASHEET

Modular Block Converter Systems

Traditional RF Splitter/Combiner and Directional Coupler User Manual

User s Manual. Digital Media Converter Package Part #: DL-HDCAT-WP

LCC (Little Coaxial Connector) Installation Instructions)

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

Cisco RF Gateway 1. Product Overview

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

Noise Detector ND-1 Operating Manual

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.

Model R177M and R177S Baseband Switch

PREMIUM 5e F/UTP PRODUCTS

FORWARD PATH TRANSMITTERS

Headend Systems. Series 9900 RF Signal Manager Modules. Introduction. Description

Cisco RF Gateway 1. Product Overview

ED5229GT-E Series. Page 1 of 8

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Benchtop Portability with ATE Performance

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

JD725A Cable and Antenna Analyzer - Dual Port

6000 Series Patch Panel Terminating Instructions

Advanced Test Equipment Rentals ATEC (2832)

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Model PR710 Series Signal conditioner operating guide

Simple all-in-one design style with front stereo speakers and natural ventilation system

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

ED5229GT-E/GTRE Series

Headend Optics Platform (CH3000)

Stud Welding Equipment

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

L-Band Fiber Optic Links

High Performance fibre systems

Telephony Training Systems

Automated Local Loop Test System

SIMATRIX NEO V2 Modular Video Matrix

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Analog HD video over fiber converters for smart HD CCTV

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Analog Dual-Standard Waveform Monitor

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

1/3 RACK-MOUNTED BLOCK CONVERTERS

I/A Series Hardware Fiber Optic LAN Converter

Long Distance L-Band Fiber Optic Links

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

The 1.2 GHz NCI solution from Technetix:

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

National Park Service Photo UTAH-1OO/3. MADI Terminal.

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

RACKS, ENCLOSURES AND CABLE MANAGEMENT

Datasheet. Licensed Backhaul Radio. Models: AF-11FX-L, AF-11FX-H. Full-Duplex, Point-to-Point Radio. 11 GHz Frequency Operation

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

E3/DS3 Fibre Extender

User s Manual. Digital Media Converter Package Part #: DL-HDCAT

Telephony Training Systems

3G-SDI Fiber Optic Digital Extension Modules in 19 1RU Frame

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

LandRake HYC V 4006-MIMO Series 4GHz PTP / NATO Mobile Mesh Series

Chameleon Labs Model 7720

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Dynatel Advanced Cable Locator 2250

LEGEND L6. # Designed and engineered in the U.K. 6 Modules Just 3U

DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES

Transcription:

With over a decade of proven design and manufacturing expertise in the repeater market, ADC provides both the DS3 ntraoffice (R) and Bridging ffice Repeater (BR). Built for reliability, modularity and density, ADC repeaters provide the distinctive switchselectable capability, allowing either DS3 or STS-1 signal rates with a flip of a switch. The R enhances network flexibility by allowing the extension of cable distance between network elements. A typical application for intraoffice repeaters is signal extension between multiple floors within a central office. This repeater also extends cross-connect cable distances within long line-ups on the same floor. The BR products allow for in-service patch and roll functions when in-service rerouting or patching of DS3 or STS-1 signals at the -3 bay are required. Repeater cards can be added as needed to the chassis and the convenient portable unit with its lightweight design allows easy use in multiple locations. ADC has a proven track record and has been designing and manufacturing a reliable line of intraoffice repeaters and bridging office repeaters since 1988. Features: Highest Standards - eets NEBS Level 3 standards Highest Density - Up to 16 modules in a 6"H x 23"W chassis odular System - Flexibility to add modules as network grows Compatibility - Chassis design fits into same -3 bay systems

To provide maximum long-term value, ADC offers a wide variety of modules and features for repeater applications. The repeater products reflect ADC's emphasis on practical design. They follow a modular scheme that allows service providers to add modules one at a time to meet their service requirements with peak efficiency. The DS3/STS-1 intraoffice and bridging office repeaters are available in non-protected or in fully protected hot stand-by configurations. The protected modules contain redundant generators. n the event of a failure in the working module, an error condition is detected, and the working module switches over to its dedicated "protect module" in less than 20 milli-seconds. Dual ntraoffice Repeater Using ADC's DS3/STS-1 Dual ntraoffice Repeater (R), which supports bi-directional transmission, service providers can extend the normal cross-connect range between modules from 21 feet to 450 feet. Similarly, the distance from modules to network elements can be extended from 225 feet to 675 feet. odules are available in non-protected or fully protected hot stand-by mode versions. Features and Benefits deal for co-location applications and multiple floor central office environments igrating to a higher bandwidth is greatly simplified by use of front access signal rate switch Repeaters regenerate superior signal quality ensuring network elements receive proper signal levels in extended cable arrangement Application for -3 Bay to -3 Bay NETWRK ELEENT UT N Application for -3 Bay to Network Element 225' DS3/STS-1 DUAL NTRAFFCE REPEATER 225' 225' NETWRK ELEENT UT -3 BAY T -3 BAY 450 FEET AXU *Distances are based use of 735A cable N NETWRK ELEENT DS3/STS-1 DUAL NTRAFFCE REPEATER NETWRK ELEENT UT 225' 450' UT N N -3 BAY T NETWRK ELEENT 675 FEET AXU 2

Dual ntraoffice Repeater rdering nformation RP3-A10000 Specifications ELECTRCAL Power nput Voltage: nput Current: N/UT mpedance: Recommended Fusing: DS3 CRCUT nput/utput mpedance: nput Signal nput Level: Frequency: utput Signal Drive Distance (Short): Drive Distance (Long): utput Power: Pulse Amplitude: STS-1 CRCUT nput/utput mpedance: nput Signal nput Level: Frequency: utput Signal Drive Distance (Short): Drive Distance (Long): utput Power: Pulse Amplitude: Description Dual ntraoffice odules Non-Protected Dual ntraoffice Repeater (R) Non-Protected Dual ntraoffice Repeater with ndividual Alarm Disable Switch (R) Protected Dual ntraoffice Repeater (PR) Catalog Number RP3-A10000 RP3-A20000 RP3-F10000-42 to -56 Vdc 76/105 ma maximum R; 85/125 ma maximum PR 75 hms R: 2.5A* PR: 3.0A* 75 hms -8 dbm to 4.7 db R/PR 44.736 bps ± 20 ppm 0 to 200' (0 to 61 m) using 734-type cable 0 to 100' (0 to 30.48 m) using 735A-type cable 200 to 450' (0 to 144.2 m) using 734-type cable 100 to 225' (30.48 to 68.6 m) using 735A-type cable 75 hms -5.5 to 4.7 db 51.840 bps ± 20 ppm 0 to 200' (0 to 61 m) using 728-type cable 0 to 450' (0 to 137 m) using 728-type cable Per T1.102.1993 * Based on 23" chassis/16 repeaters 3

Dual Bridging ffice Repeater ADC's DS3/STS-1 Dual Bridging ffice Repeater (BR) and fully Protected Bridging ffice Repeater (PBR) adds the capabilities that service providers need to reconfigure circuits without disrupting service. t supports in-service "patch-and-roll" functions in which a new parallel configuration is established by bridging off a small portion of the signal from the existing network and boosting it to full power with a BR. nce the new circuit is fully functional, new cross-connect jumpers can be run and the old ones removed. Features n-service patching capabilities allow continuous service to customers while reconfiguring circuits DS3 or STS-1 switch-selectable BR module can be used in either rack-mount or portable chassis Available in non-protected, fully protected, and non-protected extended output range module versions n-service Patching Application DS3/STS-1 SGNAL FFCE A DS3/STS-1 DUAL BRDGNG FFCE REPEATER FALED R LD FACLTY DS3/STS-1 SGNAL FFCE B DS3/STS-1 DUAL BRDGNG FFCE REPEATER SPARE R NEW FACLTY 4

Dual Bridging ffice Repeater rdering nformation RP3-B10000 Specifications ELECTRCAL nput Voltage: nput Current: N/UT mpedance: Recommended Fusing: DS3 CRCUT nput Signal nput Level: Frequency: utput Signal Drive Distance (Short): Drive Distance (Long): utput Power: Pulse Amplitude: STS-1 CRCUT nput Signal nput Level: Frequency: utput Signal Drive Distance (Short): Drive Distance (Long): utput Power: Pulse Amplitude: Description Dual Bridging ffice odules Non-Protected DS3/STS-1 Dual Bridging ffice Repeater (BR) Non-Protected Dual Bridging ffice Repeater with Extended utput Range (BR) Protected Single Bridging ffice Repeater (PBR) -42 to -56 Vdc 85/125 ma maximum BR; 95/140 ma maximum PBR 75 hms BR: 3.0A* PBR: 3.5A* -26 dbm to -15 dbm 44.736 bps ± 20 ppm 0 to 200' (0 to 61 m) using 734-type cable** 0 to 100' (0 to 30.48 m) using 735A-type cable 200 to 450' (61 to 137 m) using 734-type cable*** 100 to 225' (30.48 to 68.6 m) using 735A-type cable -26 dbm to -15 dbm 51.840 bps ± 20 ppm Catalog Number RP3-B10000 RP3-B20000 RP3-G10000 0 to 200' (0 to 61 m) using 728-type cable** 200 to 450' (61 to 137 m) using 728-type cable*** Per T1.102.1993 * Based on 23" chassis/16 repeaters ** RP3-B10000 and RP3-B20000 modules *** RP3-B20000 module only (extended output range) 5

R/BR Repeater Chassis Features Description RP3-2A0000 Front View RP3-2A0000 Rear View 16 Position Rack ount Chassis 12 Position Rack ount Chassis 3 Position Horizontal Rack ount Chassis 1 Position Wall ount Chassis A variety of repeater chassis offer capacity, termination and mounting features to fit your system requirements. ADC's repeater chassis offers a connectorized backplane which supports pre-cabling operations in order to defer cost of repeater module plug-ins until needed for circuit turn-up. The repeater chassis is powered from two separate 48 Vdc office battery power sources. An onboard DC to DC converter within each repeater module produces the voltage required for powering signal regeneration. The 23" chassis holds 16 non-protected modules, eight pairs of protected modules or a combination of protected and non-protected modules. The 19" chassis holds 12 non-protected modules, six pairs of protected modules, or a combination of protected and non-protected modules. Chassis connectorized backplane supports pre-termination operations rdering nformation Dimensions (H x W x D) 6" x 23" x 12" (15.2 x 58.4 x 30.5 cm) 6" x 19/23" x 12" (15.2 x 48.2/58.4 x 30.5 cm) 1.75" x 23" x 12" (0.7 x 58.4 x 30.5 cm) 7.5" x 2" x 8.75" (19.1 x 5.1 x 22.2 cm) Catalog Number RP3-2A0000 RP3-1A0000 RP3-5A0000 RP3-4A0000 NTE: Repeater odules can be used in any chassis listed above. 6

DS3 Portable Bridging ffice Repeater RP3-3A0000 Front View Features 110V AC power input provides convenient means of powering the chassis Accommodates up to 9 BR or PBR modules Description 9 Position Portable Bridging ffice Repeater * With unit cover attached Dimensions (H x W x D) 7.6" x 13.5" x 13"* (19.3 x 34.3 x 33.0 cm) RP3-3A0000 Front View with Cover Attached With its lightweight design, the compact Bridging ffice Repeater (BR) portable unit is easy to carry and allows use in multiple locations. The chassis features a removable lid with a storage area for patch cords. t is also versatile because it is powered by a 110V AC power, and can easily be plugged into any 120V/60 cycle outlet. This portable unit holds a total of nine BR or PBR modules - the same repeater modules that are used in the rack-mount chassis. Lightweight and compact unit has an ergonomically-designed handle for easy transport Portable chassis has a cover for protection of the modules during transport and provides convenient storage for patch cords, accessories and the power cord. rdering nformation Catalog Number RP3-3A0000 7

Web Site: www.adc.com From North America, Call Toll Free: 1-800-366-3891 utside of North America: +1-952-938-8080 Fax: +1-952-946-3292 For a complete listing of ADC's global sales office locations, please refer to our web site. ADC Telecommunications, nc., P.. Box 1101, inneapolis, innesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in inneapolis. ADC Telecommunications, nc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. 263 09/00 Revision 2000 ADC Telecommunications, nc. All Rights Reserved An Equal pportunity Employer