CrossLine Generator Operation Manual

Similar documents
DUAL/QUAD DISPLAY CONTROLLER Operation Manual

PIX/2 Operation Manual

VSC300 / VSC400 VT300 / VT400 Operation Manual

DSP x1 Color Screen Splitter Instruction Manual

instruction manual Model 619YY video dual vertical line generator s/n

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

ARS x4 MATRIX SWITCHER Instruction Manual

instruction manual Model 619D video dual cross hair generator s/n

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan

instruction manual video scan reverser models NVCN422CS & NVCN422C

instruction manual model 315 video sync separator s/n

Kramer Electronics, Ltd. USER MANUAL. Model: CV / YC to SDI Converter

INSTRUCTION MANUAL MODEL IEC-788 NTSC/PAL, F1/F2, S-VHS CLOSED CAPTION DECODER

PRO-ScalerV2HD VGA to HDMI & Audio Scaler Converter. User s Guide. Made in Taiwan

Kramer Electronics, Ltd. USER MANUAL. Model: FC Standards Converter / TBC

instruction manual x-y indicator model 620D

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

User Manual rev: Made in Taiwan

VGA & Audio over CAT5 Distribution Series

VGA Extender LR EXT-VGA-141LR. User s Manual

VGA Extender LR EXT-VGA-141LR. User s Manual

Indoor/Outdoor Security System with Quad Monitor User s Manual

Instruction Guide. Component/Composite/S-Video to DVI-D/HDTV Scaler and Converter Component/Composite/S-Video to VGA/HDTV Scaler and Converter

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

4X1 Gefen TV Switcher GTV-HDMI N. User Manual

Kramer Electronics, Ltd. USER MANUAL. Model: SG-6005xl. Genlock Multistandard SPG/Audio Generator

BRIGHTLINK HD Video Wall Controller BRIGHTLINKAV.COM

4x1 HD Analog Audio Switcher

DVI to HD-SDI Conversion Box

TBC & Matrix Switcher TBC-5000 Instruction Manual

1:2 VGA Audio Over CAT5

Kramer Electronics, Ltd. USER MANUAL. Model: VP-100. VGA/XGA to RGBHV Converter

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

Passive Video Transceivers

CV-105. DVI & Audio to HDMI Converter. User Manual. Made in Taiwan

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

User Manual DV-HDSS-41-TX. 4x1 4K Scaling Presentation Switcher with Dual Outputs. NOTE: See FSR LIT1628 API manual for serial commands.

Cablesson HDelity 7.1ch Audio Extractor & Mixer. User Manual

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Kramer Electronics, Ltd. USER MANUAL. Model: SG Genlock Multistandard SPG / SDI / AUDIO Generator

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

VideoStamp 8 TM. Eight channel on-screen composite video character and graphic overlay with real-time clock. Version 1.01

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. Dtrovision LLC

Kramer Electronics, Ltd. USER MANUAL. Model: FC Format Converter / TBC

with Carrier Board OSD-232+ TM Version 1.01 On-screen composite video character and graphic overlay Copyright 2010 Intuitive Circuits, LLC

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

1:4 VGA Hub EXT-VGA-144 USER S MANUAL.

V R171P-HDA R171P-HDA

PC/HDTV 2-Way Converter

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

DVI to HD-SDI Scaler Pro

Universal Video Format to HDMI Converter

instruction manual video mixer model 614gs & 614g

CAT USER MANUAL.

User Guide. Video to VGA/HD Converter/Scaler DVI-3420a. Video to DVI Converter/Scaler DVI-3410a

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

CV-005B. Mini Component to HDMI Converter. User Manual. Made in Taiwan

USER MANUAL. DV-HXT-2 HDMI to CAT5e /6 EXTENDERS LIT1374

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Instruction Manual RT-91600D-SL RR-91600D-SL Sixteen Channel Video Multiplexer With Remote Diagnostic Interface

VideoEase HDMI 3x1 Switcher Kit (110V) Installation Guide

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Kramer Electronics, Ltd.

4X1 Gefen TV Switcher. GTV-HDMI User Manual

User Manual. Model 1365 Video Scaler

Kramer Electronics, Ltd. USER MANUAL. Model: 810B. Black Burst / Audio Generator

instruction manual video cross hair generator/converter model VC619

Broadcast A/V Division M-LYNX-702 V.3. Dual 7 LCD Display. User Manual

Kramer Electronics, Ltd.

Broadcast A / V Division M-LYNX-702 V.3. Dual 7 LCD Display. User Manual

FD70CV-M-C-6. Installation and Operation Manual. 7 Widescreen LCD /Standard Arm. Revision Date: 05/05/2017 Page 1 of 13. Rev: B

4 x 4 VGA Matrix Switch

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

OA White OA Black. Owner s Manual. Low Profile Digital HDTV Over-the-Air Antenna. w/built-in KING SureLock Digital TV Signal Meter

SAFETY AND NOTICE TABLE OF CONTENTS

AV Toolbox. Instruction Manual. AVT-3190HD PC/HDTV to Video Scan Converter

VGA Extender SRN. EXT-VGA-141SRN User Manual.

JACK Digital HDTV Over-the-Air Antenna w/built-in SureLock Digital TV Signal Meter

User Manual HD-HAUD-SP-RX. 100m HDBaseT HDMI Receiver

CV-937D. VGA/component, Audio & RS-232 over CAT5 Extender with RGB Delay Control & IR Pass-through. User Manual. Made in Taiwan

SXT SXGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

Kramer Electronics, Ltd. USER MANUAL. Models: VP-503xl, UXGA Scan Converter VP-504xl, UXGA/HD Scan Converter

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS

PRO-CoaxExt HDMI extender over Coaxial cable with bi-directional IR User s Guide

instruction manual video color synthesizer Model 606 & 606S

3GSDI to HDMI 1.3 Converter

JACK Digital HDTV Over-the-Air Antenna

CSA x2 Alarming RS-232 Seq. Video Switcher. Instruction Manual

Kramer Electronics, Ltd. USER MANUAL. Model: VS x1 Video Audio Switcher

USER S MANUAL. Deuce HD User's Manual WORLD HEADQUARTERS

Intelligent Security and Fire Ltd

Kramer Electronics, Ltd. USER MANUAL. Model: FC Analog Video to SDI Converter

INSTALLATION MANUAL Model: HMDD. ATSC/QAM Digital Mini Demodulator

4x1 HDTV Switcher USER MANUAL.

Transcription:

WARRANTY MicroImage Video Systems warrants that each CL5400A is free from defects due to faulty materials or improper workmanship for a period of one (1) year. MicroImage Video Systems further warrants that any part which proves defective in materials or workmanship within one (1) year, will be replaced or repaired at no cost to the user. Labor to replace defective parts will be done without charge, provided the equipment is returned to MicroImage Video Systems prepaid, insured and properly packaged. Prior return authorization must be obtained from MicroImage Video Systems. NOTE This warranty covers the MicroImage CL5400A Video CrossLine Generator only. CONDITIONS This warranty is void if the warranted part has been altered or subjected to abuse or misuse. Defective parts must be returned to MicroImage Video Systems. CrossLine Generator Operation Manual Model CL5400A SOLE WARRANTY This Warranty is in lieu of all other warranties expressed or implied including, without limitation, any implied warranty or any implied warranty of fitness for a particular purpose. MicroImage Video Systems shall have the final right to determination as to the existence and cause of any defect and its appropriate adjustment in accordance with the terms of this warranty. In no event shall MicroImage Video Systems be liable for any consequential or collateral damages. MicroImage Video Systems division of World Video Sales Co., Inc RETURNS All returns MUST have an RMA number. Please call, fax or email for an RMA form. The RMA form will have the proper shipping address for returns. PO Box 331 Boyertown, PA 19512 Phone 610-754-6800 Fax 610-754-9766 sales@mivs.com www.mivs.com Phone 610-754-6800 Fax 610-754-9766 Email techsupport@mivs.com Page 12

CONTENTS UNPACKING...3 CONNECTIONS...3 Power...3 Video Connections...3 S-Video (YC)...3 Video...4 OPERATION...4 Power...4 Position Controls...4 Lock...4 (Independent)...5 Track...5 Mirror...5 Box...5 Setup...5 Display...6 B/W...6 Dip Switch 1...6 Dip Switch 2...6 Dip Switch 3...6 Dip Switch 4...6 Reset...7 B/W Setup...7 RS232 REMOTE CONTROL...8 IN CASE OF DIFFICULTY...9 SPECIFICATIONS...10 WARRANTY...12 RETURNS...12 Version CL5400A Rev 1.0 09-01-2007 JWS/JAK, Reviewed 07-06-2015 Page 2 Page 11

The CL5400A package includes the following items: UNPACKING SPECIFICATIONS Front panel controls Line position controls (2 X and 2 Y axis), multi turn, high precision optical encoders Front panel switches 11 - Display on/off, Position locks (4), B/W, Track and Mirror modes, Box mode, Setup, and Power Rear Panel Switches (4) Resolution, Origin, 2 reserved Remote port RS-232-9 pin female D-sub connector Data rate 9600 baud, 8 data bits, no parity, 1 stop bit Data format MicroImage Control Language (MICL-CL5400A) X axis line width 81.5 us NTSC/RS170, 70nS PAL/CCIR (high res) Y axis line width 2 scan lines (interlaced) 1 scan line (non-interlaced) Line resolution 640 x 480 NTSC, 768 x 576 PAL (high res) 320 x 240, 384 x 288 PAL (low res) Adjustment range 98% of raster typical Sync system NTSC/RS170A or PAL/CCIR Genlock Precision Phase Locked Loop (PLL) Input levels NTSC 1.0 Vpp composite, 75 Ω S-Video NTSC - 1.0 Vpp (Y), 0.286 Vpp burst (C), 75 Ω PAL - 1.0 Vpp (Y), 0.300 Vpp burst (C), 75 Ω Output levels Same as respective input "5% into 75 Ω Bandwidth Greater than 30 MHz Connectors NTSC / SYNC BNC Female S-Video 4 pin mini-din Female (std. S-Video conn.) Temperature Operating 0E - 40E C (32E - 104E F) Storage -40E - 60E C (-40E - 140E F) Humidity Operating 10% - 90% (noncondensing) Storage 5% - 95% (noncondensing) Power Voltage +10 to +20VDC (+12VDC typical), neg ground Consumption 130mA at 12VDC typical (LEDs on), 180mA max. 3mA standby Size 7.5" (W) x 5.6" (D) x 2.6" (H) 190 mm (W) x 142 mm (D) x 66 mm (H) Weight 1 lb 6oz. (625g) Manufactured in Pennsylvania, USA by MicroImage Video Systems CL5400A CrossLine Unit 12Volt Universal Power Supply or equivalent This operation manual Please inspect all items carefully and report damaged or missing items to your dealer or MicroImage Video Systems. Power CONNECTIONS The CL5400A will operate from +12VDC power. A 120-240V universal power adapter is included. For medical applications, consult the factory for the availability of a very low leakage power adapter. Video Connections The MicroImage CL5400A Video CrossLine Generator will operate with either S-Video, composite video, or B&W video signals. It will automatically detect which type is connected. S-video and composite/b&w should NOT be connected at the same time or a degraded picture will result. S-Video (YC) Connect the video source (i.e. a video camera) to the S-VIDEO IN connector on the CL5400A. Connect the S-VIDEO OUT signal from the CL5400A to the monitor or other video display device. Page 10 The CL5400A uses industry standard mini-din connectors for S- Video Page 3

Video (composite or B&W video) Connect the video source (i.e. camera) to the VIDEO IN connector on the CL5400A. Connect the VIDEO OUT signal from the CL5400A to the monitor or other video display device. IN CASE OF DIFFICULTY If you are experiencing problems with any MicroImage product, you can contact MicroImage Support using the following methods: OPERATION The CL5400A is designed to be easy to operate while also providing maximum flexibility. All the controls are listed below. Phone 610-754-6800 Fax 610-754-9766 Email techsupport@mivs.com Web www.mivs.com Power The Power Switch and power indicator LED are located on the right side of the front panel. The power switch is a Asoft touch@ switch but it will remember its setting even when power is removed. Position Controls The four rotary controls adjust the position of the lines. Two controls are for the X axis and two controls are for the Y axis. The exact functions of the controls are dependent on the settings of the Track and Mirror mode switches, and are described in those sections. Normally, the first control on the left will adjust the horizontal position of a vertical (X axis) line or pair, and the second control will adjust the vertical position of a horizontal (Y axis) line or pair. The third and fourth controls may be used either to adjust the second vertical and horizontal lines, or to set the spacing between the lines within a pair. Due to the use of precision optical encoders, the unit can be powered down and will restore the last line positions on power up, even if the controls have been moved in the mean time. Lock (1 thru 4) There is a lock switch for each control (4 total). Press the lock switch to lock the controls so the associated lines will not be moved in case a control Page 4 Page 9

is accidentally altered. An LED will light to indicate that the associated control is locked. RS232 REMOTE CONTROL All standard CL5400A units have RS232 remote & query capability. In order to use the RS232 port to control the CL5400A, a remote terminal or custom software must be used. A manual describing how to control the unit is available from MicroImage Video Systems. This information is also available on the MicroImage web site at www.mivs.com. When RS232 control is used, it may affect the operation of the front panel switches and controls depending on how the modes are set by the remote software. The RS232 port on the CL5400A uses a 9 pin female D-Sub connector. For a normal PC, it is wired as a straight through connection. The functions of the pins are as follows: Pin 2 - TxD (data transmitted to CL5400A) Pin 3 - RxD (data received by CL5400A) Pin 5 - Ground Baud rate is 9600 and the data is 8N1 with no flow control. (Independent) Track Mirror Box When both the Track and Mirror modes are off, the unit will be in Independent mode. In independent mode, each of the four lines may be adjusted by its own control. The functions of the position controls will be: X1 (Vertical Line 1), Y1 (Horizontal Line 1), X2 (Vertical 2), Y2 (Horizontal 2). Neither the Track LED nor the Mirror LED will light while Independent mode is enabled. Track mode allows the lines to be repositioned without affecting the spacing between them. The left set of controls adjusts the positions of the vertical and horizontal pairs of lines. The right set of controls adjusts the spacing between the lines within a pair by moving the second line relative to the first. The functions of the controls will be: Position of vertical line pair, position of horizontal line pair, spacing of vertical lines, spacing of horizontal lines. The Track LED will light to indicate that Track mode is enabled. Mirror mode allows the lines to be repositioned without affecting the spacing between them, exactly as per Track mode. The right pair of controls sets the spacing between the lines of a pair by moving both lines relative to a point centered between them. The Mirror LED will light to indicate that Mirror mode is enabled. Pressing this switch enables the box mode. Pressing it again returns the unit to displaying full lines. When the CL5400A is placed into box mode, the lines will be truncated at their intersections, forming a box. The sides of the box may be positioned using any of the three line control modes above: Independent, Track, or Mirrored. The Box LED will light when the unit is in Box mode. Setup In Setup Mode, the lines may be set either as solid, serrated, or off. Each rotary control will affect its corresponding line: X1, Y1, X2, and Y2. The lengths Page 8 Page 5

of the serrations may be varied through 16 steps. The Setup LED will light while Setup is enabled. Display B/W The Display switch will turn all lines on or off. Note that individual lines may be rendered transparent through other functions, and may not be visible regardless of the Display setting. The Display LED will light to indicate that the display is turned on. The Black/White switch selects the brightness of the lines (black or white). The brightness levels for both black and white may be adjusted from a special mode on power up. In addition to the front panel controls, the CL5400A has four DIP switches on the rear panel. These switches are used to enable additional features on the unit. They are numbered 1 through 4. Additional features may be accessed by holding certain buttons while the CL5400A powers up. The buttons may be released once the text or line display appears. Reset To restore the unit to its factory default settings, switch the unit off, hold in Lock buttons 1 and 3, and switch the unit back on while keeping Lock buttons 1 and 3 depressed. Once the display is stable, you may release the Lock buttons. This will return the unit to normal functionality in the event that the controls or display are in an unusable state. Note: this will overwrite all existing user settings Dip Switch 1 Dip Switch 2 Dip Switch 3 Dip Switch 4 Reserved for future use Reserved for future use Y Origin Select - When the switch is in the OFF position (UP), turning the rotary controls clockwise will move the horizontal lines downward from an origin point in the upper left corner of the display. When the switch is in the ON (DOWN) position, turning the rotary controls clockwise will move the horizontal lines upward from an origin point in the lower left corner. Resolution - When the switch is in the OFF (UP) position, the CL5400A will be in Low Resolution mode. The lines will be heavier and may show less Aflicker@ on some monitors. When the switch is in the ON (DOWN) position, the CL5400A will be in High Resolution mode. The lines will be finer, but will require more rotation of the controls to move. Note that changing resolution may shift the lines off the right or bottom of the display, and may require several turns of the controls to bring them back into the field of view. Page 6 B/W Setup The B/W switch alternates between two brightness settings. The user can modify the brightness of either setting, which can be black, white, or any of 62 intermediate shades of gray. To enter the special B/W setup mode, switch the unit off, hold in the Setup button, and switch the unit back on while keeping the Setup button depressed. Once the display becomes stable, you may release the Setup button. A text box will appear on the screen, showing numeric values for the black and white levels. Rotating the first or third rotary control will adjust the black level, and rotating the second or fourth control will adjust the white level. The lines on the display will change to the current value of the last control used. Values may be set within a range of 0 through 63. Press the B/W button to save the selected brightness levels and return the unit to normal operation. Switching the unit off will exit the B/W Setup mode without saving the changes. The factory default values are 2 for black and 56 for white. Page 7