CWDM BIDI SFP Series. EOLS-BI XX 21XX 24XX 26XX 34XX Series. Features. Applications. Ordering information

Similar documents
Part No. Data Rate Wavelength Interface Temp. DDMI EOLS-BI * (note1) EOLS-BI * (note1) Up to 4.25Gbps 1550nm SC Standard NO

DWDM SFP Series. Laser

CWDM SFP Series. EOLS-1624-XX Series. Features. Applications. Ordering Information

SFP+ BIDI Series Preliminary EOLP-BI1696-XAD & EOLP-BI1696-XDA Series

EOLP-BI1696-XAD & EOLP-BI1696-XDA Series

GBIC BIDI Series EOLG-BI1X12-X series

GBIC BIDI Series EOLG-BI1X12-X series

EOLQ-851HG-02-MO Series Multi-Mode 100GBASE-SR4 QSFP28 Transceiver RoHS6 Compliant

Single Fiber SFP Series

10GE BIDI SFP+ Series

Part No. Input Output Burst-mode DDM Interface Temp. EOLS-GT-35-D* (note1) AC DC LVTTL YES SC 0~70 EOLS-GT-35-DI AC DC LVTTL YES SC -40~85

3G-SDI Video SFP CWDM nm 40km Optical Transceivers

OC-48/STM-16 Bi-directional SFP Transceiver (40km) RBT25SI2

Dual Fiber SFP Series

FTS-S12G-B53Y-005. SFP 1000Base-LX, BiDi, 1550/1310nm, single-mode, 5km

GbE SFP CWDM Transceiver (120km) RCP12SVX

QSFP28 Series Preliminary. EOLQ-161HG-20-LA2 Series. Features. Applications. Ordering Information

AddOn Computer s SFP transceivers are RoHS compliant and lead- free.

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

FTS-R27G-S31L-002DI. Multirate SFP 125Mbps-2.67Gbps, 1310nm, single-mode, 2km

The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting postamplifier

OC-48/STM-16 SFP Transceiver (SR) RSP25SS1

Specification. Small Form Factor Pluggable Transceiver (MSA) LC Receptacle SFP+ 12 Gigabit SDI TIM-A1CB1-F11

Power (dbm) λ (nm) LINK DISTANCE SDI Bit Rate Max. Link Distance (km) 3G-SDI 2.97Gbps 30 HD-SDI 1.485Gbps 30 SD-SDI 270Mbps 30

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

1550 nm TX / 1310 nm RX / 3 Gb/s Medium Power 1-Fibre SM Video SFP Transceiver

10Gbps 10km Range SFP+ Optical Transceiver

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

SFP-Bxx-ttrr. Up to 80km Sinlge-Mode SFP Transceiver. Features. Applications. Benefits

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

Part No. Input Output Burst-mode DDM Interface Temp. EOLS-GT-35-D* (note1) AC DC LVTTL YES SC 0~70 EOLS-GT-35-DI AC DC LVTTL YES SC -40~85

T A S A 2 N B 1 F A H

CWDM GBIC. 1.25Gbps GBIC Optical Transceiver, 80km Reach

CWDM / 12 Gb/s Medium Power SM Video Digital Diagnostic SFP+ Transceiver

10G- XFP- LR- AO. 10Gbs XFP Transceiver

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

WS G Gbps GBIC Optical Transceiver, 80km Reach

10G- XFP- SR- AO. 10Gbs XFP Transceiver

SNR-SFP-W43-GPON-C+ GPON OLT Series

1310nm Single Channel Optical Transmitter

10Gb/s 40km DWDM XFP Optical Transceiver

Gigabit Ethernet LC Bi-directional SFP Transceivers RBT12SLX

10G BiDi XFP 10km Optical Transceiver GBX-xxxx192-LRC

Product Specification XFP 10G LR 20km LC Optical Transceiver

Part No. Data Rate Distance Interface Temp. DDMI MMF OM3 for 70m QSFP28.100G.SR Gbps

1310nm Video SFP Optical Transceiver

FTX-S1XG-S55L-040DI. XFP 10GBase-ER, 1550nm, single-mode, 40km

XFP ZR Optical Transceiver, 80km Reach GX ZRC

XFP-1020-WA/B 10Gbps XFP Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

3G-SDI Video SFP Rx Optical Receivers

Very Long Haul Multi-rate Gigabit Ethernet SFP CWDM Transceivers with Digital Diagnostics

1550 nm / 3 Gb/s Medium Power Single Optical SM Digital Diagnostic Transmitter FVD2-1TR-SM50

10Gb/s SFP+ Optical Transceiver Module 10GBASE-LR/LW

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS. Logic Symbol Name/Description Note 1 - GND Module Ground 1

GbE SFP CWDM Transceiver (40km) RCP12SEX

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

CWDM / 3 Gb/s Medium Power Optical SM Digital Diagnostic Transmitter/Receiver FVD2-1TR-SM30-XX

10G E-PON ONU PR-30 Transceiver (20km)

Product Specification. RoHS-6 Compliant 10Gb/s 10km XFP Optical Transceiver FTLX1412M3BCL

Tunable SFP+ DWDM 10G 80Km ZR SLSSD-10GE-ZR-T

10G/1G E-PON ONU SFP+ Bidi Optical Transceiver (20km) P3157-8D20-RSP

OC-48/STM-16 LC Bi-directional SFP Transceiver (2km) RBT25xS1

XFP Bi-Directional 10G 20Km 1270/1330nmTx / 1330/1270nmRx SLXFB-XXXX-20

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

GIGALIGHT 300m XFP Optical Transceiver GX SRC

Applications: Features: Description: 10G SFP+ Transceiver LR 10km (PLS-10G-LR) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD

Gigabit Ethernet CWDM SFP Transceivers

Product Specification. 10Gb/s, 10km XFP Optical Transceiver FTLX1413M3BCL

FX-1310-F10 10Gbps XFP Optical Transceiver, 10km Reach

10Gbps SFP+ Optical Transceiver, 10km Reach

XFP Optical Transceiver

Features: Compliance: Applications: Warranty: QSFP-40G-LR4-GT 40GBASE-LR4 QSFP+ SMF Module Cisco Compatible

10Gb/s XFP Optical Transceiver Module

10303 (10G BASE-LRM SFP+) Datasheet

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

XFP 10G 850nm 300M SR SLXF-1085-SR

SHQP28-100G-LR4-B. 103/112Gb/s QSFP28 Transceiver Hot Pluggable, Duplex LC, +3.3V, 1310nm DML/PIN, Single mode, 10km, 0~70 C

GPP LRMC 10Gbps 220m Multi Mode Datacom SFP+ Transceiver

6ch LC duplex QSFP Receiver ROSA (4ch x 6Gbps) + μ-bosa (2.5Gbps) (2km) FVQ2-4R1B-SM2

Applications LX xDR 10Gb. Gb/s 10km XFP Optical Transceiver

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

LambdaFLEX Zero Chirp Tunable XFP Module TL8800ZPCND

Ordering information. 40Gb/s QSFP+ ER4 Optical Transceiver Product Specification. Features

GPON ONU Triplexer Transceiver

Intel Ethernet SFP+ Optics

QSFP-100G-LR4-AR-LEG. 100Gbase-LR4 QSFP28 Transceiver

QSFP+ 40GBASE-SR4 Fiber Transceiver

SO-QSFP28-LR4. QSFP28, 100GBase, 1310nm, SM, DDM, 10km, LC OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

EPON ONU Triplexer Transceiver

LambdaFLEX Negative Chirp Tunable XFP Module TL8900NACND

LambdaFLEX Tunable XFP Module

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

CWDM Optical Transceiver

Parameter Symbol Min. Typ. Max. Unit. Supply Voltage Vcc V. Input Voltage Vin -0.3 Vcc+0.3 V. Storage Temperature Tst C

QSFP+ 40GBASE-LR4 Fiber Transceiver

40GBd QSFP+ SR4 Transceiver

Transcription:

EOLS-BI1612-19XX 21XX 24XX 26XX 34XX Series Single-Mode 100Mbps to1.25gbps FE/GBE /FC SC/LC Single-Fiber SFP Transceiver RoHS6 Compliant Features Up to 1.25Gbps Data Links 19/21/24/26/34dB power budget optional Tx/Rx Wavelength are compliant with ITU-T G.694.2, with wavelength spacing more than 60nm Single 3.3V Power supply and TTL Logic Interface Hot-Pluggable SFP Footprint Simplex LC Connector Interface Class 1 FDA and IEC60825-1 laser safety compliant Operating Case Temperature Standard: 0 ~+70 Industrial: -20 ~+85 Compliant with SFP MSA Compliant with SFF-8472 Applications Fiber Channel Links Gigabit Ethernet Fast Ethernet WDM Gigabit Ethernet Links Other Optical Links Ordering information Part No. Data Rate Power budget Interface Temp. DDMI EOLS-BI1612-19XX* (note1) 125~1250Mbps 19dB SC Standard NO EOLS-BI1612-19XXI 125~1250Mbps 19dB SC Industrial NO EOLS-BI1612-19XXD 125~1250Mbps 19dB SC Standard YES EOLS-BI1612-19XXDI 125~1250Mbps 19dB SC Industrial YES EOLS-BI1612-19XXL* (note1) 125~1250Mbps 19dB LC Standard NO EOLS-BI1612-19XXIL 125~1250Mbps 19dB LC Industrial NO EOLS-BI1612-19XXDL 125~1250Mbps 19dB LC Standard YES EOLS-BI1612-19XXDIL 125~1250Mbps 19dB LC Industrial YES EOLS-BI1612-21XX* (note1) 125~1250Mbps 21dB SC Standard NO Page 1 of 14

EOLS-BI1612-21XXI 125~1250Mbps 21dB SC Industrial NO EOLS-BI1612-21XXD 125~1250Mbps 21dB SC Standard YES EOLS-BI1612-21XXDI 125~1250Mbps 21dB SC Industrial YES EOLS-BI1612-21XXL* (note1) 125~1250Mbps 21dB LC Standard NO EOLS-BI1612-21XXIL 125~1250Mbps 21dB LC Industrial NO EOLS-BI1612-21XXDL 125~1250Mbps 21dB LC Standard YES EOLS-BI1612-21XXDIL 125~1250Mbps 21dB LC Industrial YES EOLS-BI1612-24XX *(note1) 125~1250Mbps 24dB SC Standard NO EOLS-BI1612-24XXI 125~1250Mbps 24dB SC Industrial NO EOLS-BI1612-24XXD 125~1250Mbps 24dB SC Standard YES EOLS-BI1612-24XXDI 125~1250Mbps 24dB SC Industrial YES EOLS-BI1612-24XXL *(note1) 125~1250Mbps 24dB LC Standard NO EOLS-BI1612-24XXIL 125~1250Mbps 24dB LC Industrial NO EOLS-BI1612-24XXDL 125~1250Mbps 24dB LC Standard YES EOLS-BI1612-24XXDIL 125~1250Mbps 24dB LC Industrial YES EOLS-BI1612-26XX* (note1) 125~1250Mbps 26dB SC Standard NO EOLS-BI1612-26XXI 125~1250Mbps 26dB SC Industrial NO EOLS-BI1612-26XXD 125~1250Mbps 26dB SC Standard YES EOLS-BI1612-26XXDI 125~1250Mbps 26dB SC Industrial YES EOLS-BI1612-26XXL* (note1) 125~1250Mbps 26dB LC Standard NO EOLS-BI1612-26XXIL 125~1250Mbps 26dB LC Industrial NO EOLS-BI1612-26XXDL 125~1250Mbps 26dB LC Standard YES EOLS-BI1612-26XXDIL 125~1250Mbps 26dB LC Industrial YES EOLS-BI1612-34XX* (note1) 125~1250Mbps 34dB SC Standard NO EOLS-BI1612-34XXI 125~1250Mbps 34dB SC Industrial NO EOLS-BI1612-34XXD 125~1250Mbps 34dB SC Standard YES EOLS-BI1612-34XXDI 125~1250Mbps 34dB SC Industrial YES EOLS-BI1612-34XXL* (note1) 125~1250Mbps 34dB LC Standard NO EOLS-BI1612-34XXIL 125~1250Mbps 34dB LC Industrial NO EOLS-BI1612-34XXDL 125~1250Mbps 34dB LC Standard YES EOLS-BI1612-34XXDIL 125~1250Mbps 34dB LC Industrial YES Note1: Standard version, X refer to CWDM Wavelength range 1270nm to 1610nm, A=1270, B=1290 Q=1590, R=1610. TX and RX wavelength spacing must 60nm. Typical transmitter and receiver wavelength combinations of 19dB power budget list in the following table. For the relation between transmission distance and power budget, it is related to the power penalty, the value is about 0.40~0.45dB/km under 1270~1450nm and 0.30~0.35dB/km under 1470~1610nm. *The product image only for reference purpose. Page 2 of 14

Typical Tx/Rx Combinations and PN of 19dB budget Illustration: Standard Version PN Tx Rx EOLS-BI1612-19CL 1310nm 1490nm EOLS-BI1612-19LC 1490nm 1310nm EOLS-BI1612-19LO 1490nm 1550nm EOLS-BI1612-19OL 1550nm 1490nm EOLS-BI1612-19MP 1510nm 1570nm EOLS-BI1612-19PM 1570nm 1510nm EOLS-BI1612-19MQ 1510nm 1590nm EOLS-BI1612-19QM 1590nm 1510nm CWDM* Wavelength Band O-band Original E-band Extended S-band Short Wavelength Nomenclature Wavelength(nm) Min. Typ. Max. A 1264 1270 1277.5 B 1294 1290 1297.5 C 1304 1310 1317.5 D 1324 1330 1337.5 E 1344 1350 1357.5 F 1364 1370 1377.5 G 1384 1390 1397.5 H 1404 1410 1417.5 I 1424 1430 1437.5 J 1444 1450 1457.5 K 1464 1470 1477.5 L 1484 1490 1497.5 M 1504 1510 1517.5 N 1524 1530 1537.5 C-band Conventional O 1544 1550 1557.5 L-band Long Wavelength P 1564 1570 1577.5 Q 1584 1590 1597.5 R 1604 1610 1617.5 CWDM*: 18 Wavelengths from 1270nm to 1610nm, each step 20nm. Please contact EOPTOLINK to confirm the wavelength availability. Page 3 of 14

Regulatory Compliance* Note2 CWDM BIDI SFP Series Product Certificate Certificate Number Applicable Standard EN 60950-1:2006+A11+A1+A12+A2 TUV UL R50135086 E317337 EMC CE AE 50285865 0001 EN 60825-1:2014 EN 60825-2:2004+A1+A2 UL 60950-1 CSA C22.2 No. 60950-1-07 EN 55022:2010 EN 55024:2010 FCC WTF14F0514417E 47 CFR PART 15 OCT., 2013 FDA / CDRH 1040.10 ROHS / 2011/65/EU Note2: The above certificate number updated to June 2014, because some certificate will be updated every year, such as FDA and ROHS. For the latest certification information, please check with Eoptolink. Product Description The EOLS-BI1612-XX series is small form factor pluggable module for GBE/FC single fiber communications. It is with the SFP 20-pin connector to allow hot plug capability. The EOLS-BI1X12-XXD series are designed to be compliant with SFF-8472. Absolute Maximum Ratings Parameter Symbol Min. Max. Unit Storage Temperature T S -40 +85 C Supply Voltage V CC -0.5 3.6 V Operating Relative Humidity - 95 % *Exceeding any one of these values may destroy the device immediately. Recommended Operating Conditions Parameter Symbol Min. Typical Max. Unit EOLS-BI1612-X 0 +70 Operating Case Temperature T c C EOLS-BI1612-XI -20 +85 Power Supply Voltage V CC 3.15 3.3 3.45 V Power Supply Current I CC 300 ma Date Rate FE 100 Mbps FC 1.063 Gbps GBE 1.25 Gbps Performance Specifications - Electrical Parameter Symbol Min. Typ. Max Unit Notes Transmitter LVPECL Vin 400 2000 mvpp AC coupled Page 4 of 14

Inputs(Differential) Input Impedance (Differential) Tx_Dis CWDM BIDI SFP Series Zin 85 100 115 ohms Disable 2 Vcc Enable 0 0.8 Tx_FAULT Fault 2 Vcc+0.3 normal 0 0.5 V Receiver LVPECL Outputs (Differential) Vout 370 2000 mvpp Output Impedance Rx_LOS (Differential) MOD_DEF ( 0:2 ) Zout 85 100 115 ohms LOS 2 Vcc+0.3 V normal 0 0.8 V VoH 2.5 V VoL 0 0.5 V Performance Specifications - Optical V inputs* (note5) Rin > 100 kohms @ DC AC coupled outputs* (note5) With Serial ID (CWDM DFB and PIN-TIA with 19dB Power Budget) Parameter Symbol Min. Typical Max. Unit Power budget 19 db Data Rate 100 1250 Mbps Transmitter Channel Centre Wavelength* (note9) λ C -6 λ C λ C +7.5 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power* (note3) Pout -5 0 dbm Extinction Ratio* (note4) ER 9 db Rise/Fall Time(20%~80%) tr/tf 2 ns Output Optical Eye* (note4) Compliant with IEEE 802.3ah-2004* (note7) TX_Disable Assert Time t_off 10 Us Receiver Channel Centre Wavelength* (note9) λ-20 λ λ+20 nm Receiver Sensitivity* (note6) Pmin -24 dbm Receiver Overload Pmax -3 dbm Return Loss 12 db Optical Path Penalty 1 db LOS De-Assert LOSD -25 dbm LOS Assert LOSA -35 dbm LOS Hysteresis* (note8) 0.5 db Page 5 of 14

(CWDM DFB and PIN-TIA with 21dB Power Budget) Parameter Symbol Min. Typical Max. Unit Power budget 21 db Data Rate 100 1250 Mbps Transmitter Channel Centre Wavelength* (note9) λ C -6 λ C λ C +7.5 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power* (note3) Pout -3 +2 dbm Extinction Ratio* (note4) ER 9 db Rise/Fall Time(20%~80%) tr/tf 2 ns Output Optical Eye* (note4) Compliant with IEEE 802.3ah-2004* (note7) TX_Disable Assert Time t_off 10 Us Receiver Channel Centre Wavelength* (note9) λ-20 λ λ+20 nm Receiver Sensitivity* (note6) Pmin -24 dbm Receiver Overload Pmax -3 dbm Return Loss 12 db Optical Path Penalty 1 db LOS De-Assert LOSD -25 dbm LOS Assert LOSA -35 dbm LOS Hysteresis* (note8) 0.5 db (CWDM DFB and PIN-TIA with 24dB Power Budget) Parameter Symbol Min. Typical Max. Unit Power budget 24 db Data Rate 100 1250 Mbps Transmitter Channel Centre Wavelength* (note9) λ C -6 λ C λ C +7.5 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power* (note3) Pout 0 +5 dbm Extinction Ratio* (note4) ER 9 db Rise/Fall Time(20%~80%) tr/tf 2 ns Output Optical Eye* (note4) Compliant with IEEE 802.3ah-2004* (note7) TX_Disable Assert Time t_off 10 Us Receiver Channel Centre Wavelength* (note9) λ-20 λ λ+20 nm Receiver Sensitivity* (note6) Pmin -24 dbm Receiver Overload Pmax -3 dbm Return Loss 12 db Page 6 of 14

Optical Path Penalty 1 db LOS De-Assert LOSD -25 dbm LOS Assert LOSA -35 dbm LOS Hysteresis* (note8) 0.5 db (CWDM DFB and PIN-TIA with 26dB Power Budget) Parameter Symbol Min. Typical Max. Unit Power budget 26 db Data Rate 100 1250 Mbps Transmitter Channel Centre Wavelength* (note9) λ C -6 λ C λ C +7.5 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power* (note3) Pout 0 +5 dbm Extinction Ratio* (note4) ER 9 db Rise/Fall Time(20%~80%) tr/tf 2 ns Output Optical Eye* (note4) Compliant with IEEE 802.3ah-2004* (note7) TX_Disable Assert Time t_off 10 Us Receiver Channel Centre Wavelength* (note9) λ-20 λ λ+20 nm Receiver Sensitivity* (note6) Pmin -26 dbm Receiver Overload Pmax -3 dbm Return Loss 12 db Optical Path Penalty 1 db LOS De-Assert LOSD -27 dbm LOS Assert LOSA -42 dbm LOS Hysteresis* (note8) 0.5 db (CWDM DFB and APD-TIA with 34dB Power Budget) Parameter Symbol Min. Typical Max. Unit Power budget 34 db Data Rate 100 1250 Mbps Transmitter Channel Centre Wavelength* (note9) λ C -6 λ C λ C +7.5 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power* (note3) Pout +1 +5 dbm Extinction Ratio* (note4) ER 9 db Rise/Fall Time(20%~80%) tr/tf 2 ns Output Optical Eye* (note4) I Compliant with IEEE 802.3ah-2004* (note7) TX_Disable Assert Time t_off 10 Us Receiver Page 7 of 14

Channel Centre Wavelength* (note9) λ-20 λ λ+20 nm Receiver Sensitivity* (note6) Pmin -33 dbm Receiver Overload Pmax -8 dbm Return Loss 12 db Optical Path Penalty 1 db LOS De-Assert LOSD -34 dbm LOS Assert LOSA -45 dbm LOS Hysteresis* (note8) 0.5 db Note3: Output is coupled into a 9/125μm single-mode fiber. Note4: Filtered, measured with a PRBS 2 7-1 test pattern @1250Mbps. Note5: LVPECL logic, internally AC coupled. Note6: Measured at all data rates specified in Data Rate table with ER=9 db, 2 7-1 PRBS data pattern, BER <1E-12. Note7: Eye pattern mask Note8: LOS Hysteresis Note9: The channel center wavelength of transmitter side is compliant with table <CWDM* Wavelength (0~70C)>, and the channel center wavelength of receiver side is the typical wavelength of CWDM channel ±20nm Functional Description of Transceiver Page 8 of 14

SFP Transceiver Electrical Pad Layout CWDM BIDI SFP Series Pin Function Definitions Pin Num. Name FUNCTION Plug Seq. Notes 1 VeeT Transmitter Ground 1 5) 2 TX Fault Transmitter Fault Indication 3 TX Disable Transmitter Disable 3 3 1) 2), Module disables on high or open 4 MOD-DEF2 Module Definition 2 3 3) 2 wire serial ID interface. 5 MOD-DEF1 Module Definition 1 3 3) 2 wire serial ID interface. 6 MOD-DEF0 Module Definition 0 3 3), Grounded within the module. 7 Rate Select Not Connect 3 Function not available 8 LOS Loss of Signal 3 4) 9 VeeR Receiver Ground 1 5) 10 VeeR Receiver Ground 1 5) 11 VeeR Receiver Ground 1 5) 12 RD- Inv. Received Data Out 3 6) Page 9 of 14

13 RD+ Received Data Out 3 7) 14 VeeR Receiver Ground 1 5) 15 VccR Receiver Power 2 3.3 ± 5%, 7) 16 VccT Transmitter Power 2 3.3 ± 5%, 7) 17 VeeT Transmitter Ground 1 5) 18 TD+ Transmit Data In 3 8) 19 TD- Inv. Transmit Data In 3 8) 20 VeeT Transmitter Ground 1 5) Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 10 K Ω resistor. Its states are: Low (0 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K 10KΩresistor on the host board. The pull-up voltage shall be VccT or VccR. Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 5) VeeR and VeeT may be internally connected within the SFP module. 6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 370 and 2000 mv differential (185 1000 mv single ended) when properly terminated. 7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module. Page 10 of 14

8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 400 2000 Mv (250 1200Mv single-ended), though it is recommended that values between 500 and 1200 Mv differential (250 600Mv single-ended) be used for best EMI performance. EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not write protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. The diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2h. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 9.3. Page 11 of 14

Recommend Circuit Schematic CWDM BIDI SFP Series Mechanical Specifications SC Page 12 of 14

*This 2D drawing only for reference, please check with Eoptolink before ordering. Laser Emission LC Obtaining Document You can visit our website:http://www.eoptolink.com Or contact Listed at the end of the documentation to get the latest documents. Revision History Revision Initiate Review Approve Revision History Date V1.a Cathy Kelly Released. 2009.09.10 V1.b Cathy Kelly Update the mechanical specl 2010.1.23 V1.c Cathy Updated EEPROM. 2011.3.11 V2.a Phlio Update Recommend Circuit Aug 10, 2011 V2.b Phlio Remove EEPROM Detail Aug 22, 2011 Page 13 of 14

Information Change Power Link Budget V2.c Phlio Kelly Add 21db link budget items Sep. 26, 2011 V2.d Kelly Add 36Db budget product and PN illustration, update Oct 8, 2011 SFP BIDI SC photo. V2.e Kelly Update photo. Nov 4, 2011 V2.f Angela, Jans Kelly Update power budget, delete 36Db product. Dec 8,2012 V2.g Angela Kelly Correct slip of a pen Jan 18,2013 V2.h Angela, Jans Kelly Update pin definition notes Jan 23,2013 Angela Kelly/Vina Update the regulatory compliance, LOSA, optical output eye pattern mask and the 2D drawing. Feb 17,2016 Notice: Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add: Floor 5 Building 2 No. 21 Gaopeng Avenue High-Tech District CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 035-85122709 ext 816 & 809 Fax: (+86) 035-85121912 Postal: 610041 E-mail:sales@eoptolink.com http://www.eoptolink.com Page 14 of 14