Operating instructions III / 2004

Similar documents
Professional-Practice

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

QTi DALI 2X14/24/ DIM

QUICKTRONIC INTELLIGENT DALI DIM T8

QUICKTRONIC FIT 8. Product family datasheet. ECG for FL 26 mm

The systematic way to get more light In most cases, the lamp developments are effectively system developments as they also involve modern electronic

Luminaire installation box Surface-mounted box Ceiling installation box

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

QTi 2X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DIM T5 ECG dimmable 1 10 V for FL 16 mm. Areas of application.

Tectiv 220 Instructions for use

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Gamma instabus. Technical product information

OPTOTRONIC Intelligent

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

As versatile as your requirements.

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Mosaic TM Dimmer 3 x 1000 W

Technical Information

ArteorTM Dimmer 3 x 1000 W / /60

QUICKTRONIC DE LUXE HF DIM T8

WE-EF LEUCHTEN. Technical information for Eco Step Dim Basic. Product ID

Instruction manual. DALI Gateway art Installation manual

Benefits. Applications

LUNA 129 star-time

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

PHASED OUT. Control module with 3 channels/single, twin push to make switches/ presence detector/modulardim power supply

Installation Guide. HDMI 4x1 Switcher

Figure 1: Device components

SubstiTUBE Value ST8-HV5

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Emergency lighting units EM powerled

Operating Manual. Basic Control BC16. two-channel for eco moon

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Operating instructions

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

IP Roombox. Hotel Room Management

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

2-output DALI controller

Preliminary Data sheet

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Tri-level Control HF Sensor

SubstiTUBE Value ST8V-0.6m

Emergency lighting units EM powerled

OT 100/ /700 P5

SubstiTUBE Value EM ST8V-1.2m-17W-EM

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

PRODUCT FAMILY DATASHEET QUICKTRONIC PROFESSIONAL DL

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

DALI TOUCHPANEL BASIC TW. Operating and control unit

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM

OPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

ABB i-bus EIB Universal dimmer 6155 EB for Installation

SubstiTUBE Advanced ST8-HA4

15 Series - Dimmer

LED Driver Linear / area fixed output

PRODUCT FAMILY DATASHEET QUICKTRONIC MULTIWATT

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

SY-HDBT-SLIM-100S Extender Set

LED Driver Compact fixed output

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

SY-HDBT-100 Extender Set

Technical operating data

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Operating instructions Electronic preset counter Type series 717

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

LED Driver Compact fixed output

Technical operating data

Level Measurement silometer FMC 420, FMC 423

Remote Voltage Detector - JET (RVD) Medium and High Voltage kV AC

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Simply clever! The digital DIN-rail time switches by Grässlin

SY-MS121 SY-MS121-AP

SubstiTUBE Value EM Fighter Tube Technical Datasheet

LED Driver Compact dimming

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

KNX Dimmer RGBW - User Manual

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

Ultra thin LED lamp for Pool & Spa OWNER S MANUAL

KRF EMC Filters Installation, Operation and Maintenance Manual

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Sevenlogic Comfort Timer Switch

HDMI Matrix Switch, 4 x 2-Port

SceneStyle2 User Guide

LED control gear Compact fixed output

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

R xx-C0900-J074

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Product information. Front-door station series with video for surface-mount

Aspect 2 Circuit Digital Scene Control

HID control gear Electronic

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

EGM Einthoven Goldberger Module Type 701

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

Transcription:

Operating instructions III / 2004 Light sensor TOUCH DIM LS LI OSRAM GmbH Costumer-Service-Center (CSC) Germany Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49) 1803 / 677-200 (charges apply) Fax.: (+49) 1803 / 677-202

General Contents General Installation Operation Appendix Application and function... 2 Design and dimensions... 3 Wiring diagram... 3 Installation hints... 4 General functions... 5 Controlling brightness at the workplace... 5 Troubleshooting... 7 Technical data... 8 Application and function The TOUCH DIM LS LI sensor was developed to regulate and control the brightness at workplaces. The sensor measures the brightness. The lighting conditions at the workplace are maintained at a user-adjustable set point by providing artificial light according to the amount of available daylight. If there is more than sufficient daylight, the lighting control switches off the luminaire. The TOUCH DIM sensor can be installed in luminaires (e.g. floor-standing luminaires), or by use of a flush device box with adequate cover also into the ceiling. Good workplace lighting makes the working environment more comfortable. Energy savings of up to 50% can be made compared with conventional workplace lighting. Safety and installation information The unit should be installed and tested only by a qualified electrician. Power to the units must be switched off before any work is undertaken. The relevant safety and accident prevention regulations must be observed. The TOUCH DIM sensor is used exclusively for controlling electronic control gear type QUICKTRONIC INTELLIGENT LI (QTi LI...DIM) or HALOTRONIC INTELLIGENT LI (HTi LI..DIM). No further control units may be operated on the control line. Other applications are not permitted. They may destroy the TOUCH DIM LS/PD LI and other equipment. The maximal number of ECG and the maximal overall cable length between push button, sensor and ECG has to be respected (see Technical data). If the control cable is wired with external voltage, the unit may be destroyed. The TOUCH DIM Sensor may only be supplied with AC operating voltage. This is particularly important to remember if UPS systems are used. page 2 OSRAM - operating instructions TOUCH DIM LS LI

Installation Design and dimensions Wiring diagram L N PE Push button (manual control) L N S TOUCH DIM Sensor ECG QTi LI ECG QTi LI ECG QTi LI 1 2 3 4 1 2 3 4 1 2 3 4 Lamp Lamp Lamp max. 4 QTi ECG or HTi transform ers signal wire length max. 10m Push button and sensor have to be connected to the same mains phase! ECG QTi LI 1 2 3 4 Lamp OSRAM - operating instructions TOUCH DIM LS LI page 3

Installation Installation hints The sensor is connected to a 3 wire cable which is admitted for mains voltage. Parallel connection of several sensors is not allowed. The sensor is typically installed in luminaires, ceiling installation is possible by use of a flush device box and an adequate cover. When installing the sensor, please note the following: Avoid placing the sensor where it is directly exposed to light from other sources as this will lead to incorrect measurements. The sensor should be installed centrally in the sphere of action, so that all controlled lumnaires contribute with the same proportion to the measured brightness. Example: Office with 4 controlled luminaires: window controlled luminaire controlled luminaire possible place of installation window controlled luminaire controlled luminaire optimal place of installation Touch DIM Sensor 2m window min. 40 1m Height above window sill 0m 1m min. distance to window 2m 0m Diagram: minimal distance to windows page 4 OSRAM - operating instructions TOUCH DIM LS LI

Operation General functions Switching the luminaire on/off 1. Briefly press the switch once. The luminaire is switched on or off each time the switch is operated. Changing the brightness With the luminaire switched off: 1. Press the switch. Keep pressing the switch until the required brightness is reached. With the luminaire switched on: 1. Press the switch. Keep pressing the switch until the required brightness is reached. The luminaire goes on at minimum brightness. The longer the switch is pressed, the brighter the luminaire gets. When the switch is released the luminaire will remain at the brightness it has reached. The brightness will change. When the switch is released the luminaire will remain at the brightness it has reached. Switching between more and less brightness: 2. Release the switch then press it again. Keep pressing the switch until the required brightness is reached. Every time the switch is held down the unit toggles between more light and less light. Note: Changing the brightness deactivates brightness control. When the unit is switched on again brightness control is reactivated, if a set point value was is stored. Controlling brightness at the workplace Adjustment / Storage of the set point for brightness control 1. Change the brightness to the required level by holding down the switch. 2. Once the set point is reached, make a double click (switch pressed twice briefly within short time) within 30 s. The brightness will change. When the switch is released the luminaire will remain at the brightness it has reached. The brightness you have just set will be stored as the new set point. The luminaire will flash twice to confirm that this value has been stored. OSRAM - operating instructions TOUCH DIM LS LI page 5

Operation Deactivation of the brightness control Brightness control can be completely deactivated: 1. If the luminaire is switched on, switch off the luminaire by briefly pressing the switch. 2. Make a double click (switch pressed twice briefly within short time). The set point is erased and brightness control is now disabled and the luminaire will dim to 100%. To activate the brightness control again, store a new set point as described on the previous page. page 6 OSRAM - operating instructions TOUCH DIM LS LI

Appendix Troubleshooting The luminaire is not working. Possible cause: There is no power. Check if the luminaire is connected to power. The lamps are faulty. Replace them. The luminaire was switched off at the switch. Switch the luminaire on. The luminaire is not regulating its brightness to the set point. Possible cause: After setting the brightness you must press the switch twice within 30 seconds. If you press the switch later a set point will not be stored. Bear this time in mind. Brightness control is not started until 5 seconds after the set point has been set. Within this time any other switch operations are ignored. Bear this time in mind. Brightness control was deactivated by changing the brightness level with the switch. Switch the luminaire off and on again. Brightness control is deactivated because set point was erased. Store a new set point. The luminaire is not reacting as expected to switch operations. Possible cause: The switch is being pressed too long. Please note: Hold down the switch to change the brightness until the luminaire reaches the brightness level you want. For all other functions, just briefly press the switch. If you cannot remedy the problem, please contact the customer service department of your luminaire manufacturer. OSRAM - operating instructions TOUCH DIM LS LI page 7

Appendix Technical data Designation : TOUCH DIM LS LI, light sensor Operating voltage : 220 240V AC / 50 60Hz (no DC operation) Connections : L, N, S (signal) Interface : OSRAM specific, max. 4 QTi LI ECG or. 4 HTi transformers connectable overall length of signal Max. 10 m connection : Power consumption : approx. 0,5 W Operating temperature : 0C...+ 50 C Adjustable light value : 10 300 lux measured at sensor resp. approx. 10-1200 lux at desk surface Pollution severity: 2 Dry, not conductive to IEC 664 CE requirement : EMC to EN 61547 Dimensions: 63 x 29 x 21mm (L x W x H) Protection class: II Protection type: IP 20 The CE symbol signifies compliance with the relevant EU Directives. page 8 OSRAM - operating instructions TOUCH DIM LS LI