PRODUCTION BIBLE. last update November 2015

Similar documents
VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

Tickets will be sold through our ABC account and all tickets are scannable on entry.

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice!

Les Docks / Av. de Sévelin Lausanne. Technical Rider

THEATRE EQUIPMENT DECEMBER 2017

Contents. 1. Contacts. 2. Directions & Transport Links 2.1. Address 2.2. Local Map & Directions 2.3. Public Transport

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Technical Specifications

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

Dr JOHN GALLAGHER CONCERT CHAMBER

Treefort Music Fest- March Festival Information Main Stage

TECHNICAL SPECIFICATION

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

Technical Specification

UNIVERSITY CONCERT HALL. Technical Specification

SOUND TECH RIDER FIDO

Information for Incoming Companies

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Technical Specifications

Hard Rock Cafe Times Square Sound System Advance Sheet

FASO DANCE COMPANY KALAKUTA REPUBLIK

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

Barbican Concert Hall Sound System Spec

SUSAN AGLUKARK. Keynote Speaker/ Solo Presentation TECHNICAL RIDER HOSPITALITY RIDER 2018 Revision 1/15/18 KEY CONTACT:

CARGO PRODUCTION GUIDE 2016

Ed Blackwell Production Manager Mike Weller Head of Music

Music Hall of Williamsburg

SHOWBOX SODO TECHNICAL SPECIFICATIONS

BITUSA 2019 General DRESSING ROOMS

TECHNICAL SPECIFICATIONS LEPERCQ

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

GENERAL INFORMATION CONTACT DETAILS. Venue Booker: Shaun Adams E: P: (03)

SOUND + DESIGN THE FUNKTION-ONE SOUND SYSTEM ECO-CONSCIOUS DESIGN AND CONSTRUCTION

Technical specifications - Compagnie José Besprosvany Prométhée enchaîné

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Specifications

Main Stage Technical Specs - Hall #2

National Theater_sound

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

The Taal Inc. Rhythm Ensemble Tech Rider

Technical Specifications

TECHNICAL SPECIFICATIONS 2018!

GENERAL INFO. GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony. SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

TECHNICAL SPECIFICATIONS

Thank you for thinking of The Fonda Theatre for your private event!

Event Hire Equipment Packages

Project manager (PM): Pamela Næss Mail: Phone:

Technical Information

RIDER 2018 version 1 English

Technical Rider. (last update: Jan. 2016) For more info: Yves Moquin, technical director (514)

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Technical Specifications for the Rival Theatre 2018

WE RE BACK CONCERT PACK UNSWROUNDHOUSE.COM

Complete guide Compiled January 2014

Small Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Patriots Theater at the War Memorial Technical Data

LOAD IN / LOAD OUT CARS / SPLITTER VAN / NIGHTLINER THROUGH MAIN ENTRANCE SITUATED AT AUGUSTE ORTSSTRAAT 20-28, 1000 BRUSSEL.

Analog General Information West End Ave. Nashville, TN, Time Zone: CST

TECHNICAL SPECS SECOND HALL PATRONAAT

Technical Data Sheet

Production Advance Information

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Sound Equipment Sound Control Room

MAIN STAGE GENERAL INFO AND FACILITIES

Technical Specification for the Alley Theatre, Strabane

Bloomington Center for the Performing Arts. Technical Specifications

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

CONTENTS. CONTACT DETAILS. FINDING US. VENUE INFORMATION. TECHNICAL INFORMATION. ROOM DIAGRAMS.

The Lantern Technical Information

STANDARD TIME SCHEDULE JUPILER STAGE doors + showtime HET PARADIJS: 20:30 // 21:00h 14:00 Start local tech crew & backstage manager

Contact. Directions. Stichting Studio301 Overtoom HW Amsterdam The Netherlands.

Monty Kultuurfaktorij Technical Rider

Technical Specification Ardhowen Theatre

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

v. 2.4 Address: Musikhuset Posten Østre Stationsvej 35 DK-5000 Odense C Booking/management: Morten Østlund

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Technical specifications Main theatre. Sound

TECHNICAL SPECIFICATIONS

Ex-Hire Used Equipment Price List

Tech Specs and General Terms & Conditions 2018

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet

ARTISTIC RENTALS RATE CARD. Queen Elizabeth Hall AUDITORIUM CAPACITIES ARTISTIC HIRE RATES

The Willoughby Brothers

Technical Pack. Attenborough Arts Centre

Mics, DIs, Stands, and Cables

TECHNICAL / HOSPITALITY RIDER

Talent Booking: Ph: Fax: Ph: Fax: Ph: Cell: Ph:

TECHNICAL REQUIREMENTS

Theatre Technical Specifications

The Lexington VENUE SPEC. The Lexington Live music venue and whisky lounge. Version 2.5 Updated January 2015

The Haymarket Basingstoke Technical Specifications

Technical Pack. Embrace Arts at the RA Centre

ARTISTIC RENTALS RATE CARD. Royal Festival Hall AUDITORIUM CAPACITIES ARTISTIC HIRE RATES

Transcription:

PRODUCTION BIBLE last update November 2015 FOR THE LATEST VERSION OF THIS DOCUMENT PLEASE DOWNLOAD IT FROM www.viperclub.eu/files/vipertheatre-productionbible.pdf

We welcome you to the Viper theatre and hope you will have a nice concert! To make everything work out in the best possible way during the evening, we kindly ask you to read these info sheets. 2

For Evaluation Only. TECH SPEC. Stage size: 8m. X 8m. - height from dancefloor 1m. Barrier: In-house pit barrier Total House power: 90 kw LIVE P.A.: 2x stack with 4 x Martin Audio W8LC 4x Martin Audio WS218X 8x Lab Gruppen FP3400 Power Amplifiers 2x XTA DP 426 processor Stage: 1x Monitor Consolle Soundcraft SM 20 47ch, 12 aux 1 2x HandK 18in. stage sub 2x bss dpr stereo gate 2x dbx 166A stereo compressor 1x Yamaha SPX 900 5x DBX1231 Graphic EQ, 31 bande, 2ch 2x Lab Gruppen Q10000 4ch Power Amplifiers 6x VEAM SubSnakes 8ch 8x Martin Audio 200 wedge monitor Front of house desk: 1x Mic Multicord 48ch, passive 1x Aux returns Multicord 8ch 1x Mixer Midas Heritage H3000 48ch Outboard 1x DBX 1231 Stereo 31 bands Graphic Eq 1x Lexicon PCM70 1x Yamaha SPX990 1x Yamaha SPX900 1x Lexicon PCM 91 1x Yamaha REV500 1x TC electronics D-2 1x DBX 566 Tube compressor 2 ch 2x DBX 160A comp 2x DBX 166A comp 2ch 2x BSS DPR402 Comp 2ch 2x Drawmer Punch MX40 quad Gate raisers: 2x PAV 20/40/60/80/100 DI Boxes: 4x AudiBox ProDi active 2x EMO Stereo Passive DI 2x LA - D12 - Active mono DI Dynamic mics: 5x Shure SM58 2x Shure Beta 58A 5x Shure SM57 2x Sennheiser e604 2x Sennheiser e602 1x Sennheiser e902 1x AKG D112 Condenser mics: 3x Shure PG81 2x AKG 451 wireless mics: 1x SM58 handheld radio + BLX serie receiver Mic Stands: 12x Tall boom Stands 2x Table Stands 4x Short boom stands Dj Stuff: 1x Pioneer DJM-800 2x Technics SL-1210 MK2 turntable 2x Pioneer CDJ-1000 MK3 1x Allen Heat X-one 92 2x Pioneer Cdj 100 2x Technics SL-1200 MK2 turntable Lightning desk: ChamSys PC Wing Video Control: 2x DVD player 2x 3500 Ansi Lumen LCD XGA Projector 1x Motorized projection screen 4x3mt. on backtruss First floor balcony area/bar: 2x 42 Plasma screen Lighting system stage: 4x Robe 575 XT spot moving head 4x Bars of ACL(4 each) 2x bars of 5 Led pars 240 volts 4x PAR 64 1000w 240v 4x Blinder 2 cells 1x Strobe 1500w 1x standard smoke machine Lightning system DanceHall: 2x Robe 250 xt wash moving head 2x Robe 250 xt Spot moving head 8x Led Pars 3

FLOORPLANS Lower ground floor 4

Ground floor 5

Lightning plot stage 4x Spot Robe 575xt spot Moving head 4x Bars of ACL(4 each) 2x bars of 5 Led pars 240 volts 4x Par 64 1000w 1x Strobe 1500 4x Blinder 2 cells Lightning plot house 2x Robe 250 xt wash moving head 2x Robe 250 xt spot movimg head 8x Led Pars 6

DMX CHAINS AND ADDRESSES Universe "A" (Stage) DMX Ch Heads and Dimmers 1 Blinder FOH LEFT 1-2 2 Front PAR 1 (FOH LEFT) 3 Front PAR 2 (FOH LEFT) 4 Blinder FOH RIGHT 3-4 6 Front PAR 4 (FOH RIGHT) 8 Front PAR 3 (FOH RIGHT) 9 ACL bars BackTruss 10 ACL bars External/Side Truss 25 Smoke Machine (Generic Dimmer/H63) 100 Robe 575XT Spot 1 BackTruss 120 Robe 575XT Spot 2 BackTruss 140 Robe 575XT Spot 3 BackTruss 160 Robe 575XT Spot 4 BackTruss Universe "B" (DanceHall) DMX Ch Heads and Dimmers 1 Robe 250XT wash (Entrance side) 17 Robe 250XT Wash (Entrance side) 40 Robe 250XT Spot (Stage side) 60 Robe 250XT Spot (Stage side) 80 ParLed 1 Litecraft AT10 88 ParLed 2 Litecraft AT10 96 ParLed 3 Litecraft AT10 104 ParLed 4 Litecraft AT10 112 ParLed 5 Litecraft AT10 120 ParLed 6 Litecraft AT10 128 ParLed 7 Litecraft AT10 136 ParLed 8 Litecraft AT10 200 ParLed 1 Litecraft AT10 Left Side Truss 208 ParLed 2 Litecraft AT10 Left Side Truss 216 ParLed 3 Litecraft AT10 Left Side Truss 224 ParLed 4 Litecraft AT10 Left Side Truss 232 ParLed 5 Litecraft AT10 Left Side Truss 240 ParLed 6 Litecraft AT10 Right Side Truss 248 ParLed 7 Litecraft AT10 Right Side Truss 256 ParLed 8 Litecraft AT10 Right Side Truss 264 ParLed 9 Litecraft AT10 Right Side Truss 272 ParLed 10 Litecraft AT10 Right Side Truss 510 Stage Strobo backtruss ch1 (generic/h33) 511 Stage Strobo backtruss ch2 (generic/h34) 7

SEATED FORMAT DETAILS 8 8

ENTRY PROCEDURES TICKET CHECK BOX OFFICE CLOAKROOM 9

LOAD IN DETAILS Viper Theatre load in is on Via Lombardia backdoors. Access through a parking area in Via Pistoiese. Three steps to the stage. Via Pistoiese PARKING Via Lombardia SMALL VEHICLE LOAD IN AREA 10

Viper Theatre load in is on Via Lombardia backdoors. Access through a parking area in Via Pistoiese. Three steps to the stage. LOAD IN DETAILS AREAS & PASSES Viper Theatre has unique areas for your use: 1.Production office 2.Dressing room + shower and toilette Below are the passes which are needed for those areas: AAA:Access all areas-escorting/not escorting-please specify Crew:Access all areas except dressing rooms-not escorting BACKSTAGE PASS All musicians and crew(and any guest),who will be backstage during the evening, must wear a backstage pass. Please tell the host how many backstage passes you need. It is very important that everybody wear them, since the guards have the same information. The guards do not let people backstage, if they do not wear a backstage pass. Wi-fi connection is provided in the whole building. Accounts will be settled with the host after the concert. WI-FI CONNECTION ACCOUNTS GUEST LIST The number of guestlist includes the number, which has been negotiated in the contract. In case of deviations the host must be contacted in advance. SALES OF MERCHANDISE Merchandise cannot be placed at the entrance due to the fire authorities.therefore we kindly ask you to place it in the corner next to the box office.if you have any doubts,please ask the host. 11

HIRE DEAL What you can expect as part of your hire fee: 780 standing capacity venue + sound and lights. One house manager,one house technician. One fully equipped production office with WIFI access What you cannot expect as part of your hire fee: Viper theatre experienced guest list person Use of our foyer box office and tickets machine Security staff Extra technical staff Supply of towels Any damage to the venue or equipment will be charged for Please note Viper theatre is not responsible for any equipment left in any part of the venue 12

TRAVEL INFO Mappa piagge+(link : http://www.viperclub. eu/?q=node/50) EMERGENCY INFO Police: Rifredi Peretola police station,via Sgambati 21, tel : 055/323886. A&E: Ospedale Careggi (Firenze), Viale Morgagni n. 85, tel : 055/4277247 Accident and emergency general tel:118 Fire:115 13

RECOMMENDED RESTAURANTS IN THE AREA Paladar Via Pistoiese n 315 Firenze - Tel. 055/317228 - Cell. 338/3737710 email: as.paladar@yahoo.it Trattoria Da Burde Via Pistoiese n. 154 Firenze,tel.055/311329 Xiang Shun- Great Chinese restaurant Via Della Saggina n.2 Firenze,tel. 055/319234 Aluisius-Restaurant and pizzeria Via Pistoiese n. 2/r Firenze, tel.055/308653 Eurohotel Via Pistoiese n.30 Tel:055/319234 Cosmopolitan Hotel Via Baracca n.187 Tel:055/4225800 Mirage hotel Golden Tulip Via Baracca n.231/18 Tel:055/352011 Novotel Via Tevere n. 23 Firenze Tel. 055/308338 - Fax: 055/308336. La Spiga Via Pistoiese n. 50 San Donnino Firenze Tel 055/8964025 - Cell. 3407112610 - Fax 055/8964025. HOTEL NEARBY 14