Series CDP2 Definite Purpose Contactors

Similar documents
Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Series CDP2 Definite Purpose Contactors

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

AC1036. Definite Purpose Contactors

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

Data Sheet Definite Purpose Contactors Ex9CK Series

Definite Purpose Contactors

Magnecraft Power Relays

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Series CT7N Bimetallic Overload Relays

AS09..S 3-pole Contactors - Spring Terminals

16 A and 25 A power contactors with or without handle

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Bulletin 190 IEC Modular Starter System

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Modular pulse operated latching relay 16 A

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Bulletin 190 Compact. Combination Starters

ALLEN BRADLEY TIMING RELAY

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

MILLITARY SPECIFICATION SHEET

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Minicontactorrelay,2NO/2NC,DCoperated


Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Bulletin 100-G IEC Contactors

High performance circuit breakers

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Type: DILM25 10(24V50HZ) Article No.:

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Power Circuit of a UL508A Panel. Typical UL489 Application

EXLUX ECOLUX C-LUX 6480 Series

Electronic Timer Control Day Astronomic Electronic Control

GR circuit breaker - hydraulic magnetic, Datasheet

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Pendant Light Fitting IEC Series 6470/2

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Type: DILM12 10(24VDC) Article No.:

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Bulletin 100-G IEC Contactors

02/11/2015

A V 50Hz / V 60Hz

Features XT SC 012 B B A

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.

PERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE THREE-POLE, AUXILIARY CONTACTS

llen-bradley 194R-HM4-NFPA3

Sign Illuminating Ballasts

Photoelectrics Through-beam Type PA18C.T..., DC

Kulka Military Class (A-A-59125) / (MIL-T-55164*)

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Features XT SC 012 B B A

Modular Lube Lubrication Systems System Controls

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

EXLUX ECOLUX 6480 Series

3AH3 Vacuum Circuit-Breakers

GRASSLIN - DEFROST TIMER GRASSLIN DTMV SERIES SPECIFIERS GUIDE

NEW! Wide Area Lighting - Rough Service Fluorescent. MULTIVOLTAGE Automatically Operates at 120 to 277 VAC 50 or 60 Hz *1142 only

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Datasheet - SRB301LC 24VAC/DC

Ordering details. Approval. Classification

GR circuit breaker - hydraulic magnetic, Datasheet

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

XT IEC Power Control Combination Motor Controllers

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Solid-State Digital Timer

INCH-POUND MIL-PRF-55629/21G 10 March 2010 SUPERSEDING MIL-PRF-55629/21F 21 September 2005 PERFORMANCE SPECIFICATION SHEET

Part-Turn Electric Multi-Turn Electric

Figure 1: Device components

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Single Point Flow Monitor SW118 SW119

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Transcription:

Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air conditioning, refrigeration, resistive heating and many other installations where a low cost, high performance contactor is needed. These devices offer flexibility and are designed to meet or exceed electrical and mechanical requirements as defined by definite purpose contactor standards. Popular sizes for most applications The CDP2 series consists of one, two, three and four pole contactors rated to 600V C. Three pole devices range up to 90, while the one and two pole models are rated to 40. Four pole contactors are also available ranging from 25 to 40. Flexibility and convenience make installation easy Standard Features Universal mounting plate 25 & 30 have screw power terminals that will accept ring-tongue terminals 40 and larger have box power terminals Dual quick-connect power terminals on all sizes Dual quick-connect coil terminals on all sizes Double break power contact design with feed-thru wiring Class B (130 C) coil insulation Double E magnet assembly Optional Features SPDT auxiliary contacts optional on 3- and 4-pole contactors (max of two) Optional covers for 1- and 2-pole contactors Mechanical interlock for 3-pole contactors CDP2 contactors are compact in size and offer three convenient methods of wire connection: quick connect terminals, screws or box lugs. Box lugs are standard on 40 and larger contactors. Other models come standard with combination quick connect terminals and screws that accept hex, slotted or phillips screwdrivers. One Pole Two Pole Two Pole Three Pole Four Pole 30 40 30 40 30 40 50 60 75 90 30 40 178

Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide range of voltages and 50/60 Hz ratings. Includes shading coil that reduces contact chatter. Snap-on uxiliary Contact (optional on 3 and 4 pole contactors) One or two SPDT (shown) available. lso 1NO and 1NC with 600V C rating. Industry Standard Mounting Plate Easily accessible mounting holes. Coil Terminals #6-32 screw and one.250 Quick Connect or Dual.250 Quick Connects (will accept two insulated quick connect terminals). Double E Magnet ssembly Provides optimal performance with reduced power consumption Stationary Terminal One piece terminal design with integral dual.250 Quick Connects. Meets NEM standard for spacing without insulated terminals. Base ssembly High arc resistant polyester holds stationary terminals, positions actuator and magnet/coil assembly. Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability ctuator Molded from high arc resistant polyester, holds upper magnet, movable contacts and contact springs position. Quick Selection Guide One and Two Pole Definite Purpose Contactors with C Coil - See page 152 CDP2 ➊ 1P 30 24 Type Frame Size Poles mp Rating Coil Voltage Definite = 30 & 40 1P = 1 pole 30 = 30 amps 24 = 24 volts Purpose 2P = 2 pole 40 = 40 amps 120 = 120 volts 220W = 208-240 volts 277 = 277 volts Three Pole Definite Purpose Contactors with C Coil- See page 153 CDP2 ➊➋ B 3P 30 24 Type Frame Size Poles mp Rating Coil Voltage Definite B = 30 & 40 3P = 3 poles 30 = 30 amps 24 = 24 volts Purpose C = 50 & 60 40 = 40 amps 120 = 120 volts D = 75 & 90 50 = 50 amps 220W = 208-240 volts 60 = 60 amps 277 = 277 volts 75 = 75 amps 480 = 480 volts 90 = 90 amps Four Pole Definite Purpose Contactors with C Coil - See page 154 CDP2 ➊➋ E 4P 25 24 Type Frame Size Poles mp Rating Coil Voltage Definite E = 25...40 4P = 4 poles 25 = 25 amps 24 = 24 volts Purpose 30 = 30 amps 120 = 120 volts 40 = 40 amps 220W = 208-240 volts 277 = 277 volts 480 = 480 volts ➊ Screw power terminals standard on 30. Box lug power terminals standard for 40 and larger. ➋ Box lugs on 30 available with volume special order only. 179

Definite Purpose Contactors 1 & 2 Pole - Series CDP2 One and Two Pole Definite Purpose Contactors with C Coil (Open type only) ➍ Full Load mps Poles Maximum H.P. Locked Rotor mps Resistive mps ➋ 1Ø 240V ➋ 480V 600V 120V 240V ➋ Catalog Number Price Each 30 ➊ 1 ➏ 150 75 50 40 1 2 CDP2-1P30- ➎ 64.80 50 Std. Pkg. 30 ➊ 2 150 125 100 40 2 3 CDP2-2P30- ➎ 79.90 50 Series CDP2 1-pole contactor 40 1 ➏ 200 150 120 50 2 3 CDP2-1P40- ➌ 82.50 50 40 2 200 150 120 50 2 3 CDP2-2P40- ➌ 96.10 50 Series CDP2 2-pole contactor (with optional cover) ccessories ccessory Description For use with... Catalog Number Price Contactor Cover- Prevents foreign particles from entering contactor. Covers current carrying parts. CDP2-1P30... CDP2-2P30... CDP2-1P-C ➐ CDP2-2P-C 7.79 9.36 C Coil Codes C Coil Code Ordering Instructions 180 Voltage Range 60 Hz 24 24V 120 120V 220W 208-240V 277 277V Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ 25 contactors only available by special order. Contact your Sprecher +Schuh representative. ➋ 240V rating also applies to 277V applications. ➌ Box Power Lugs are supplied as standard. Screw terminals are available on the power connections by special order only in quantity. ➍ 1 and 2 Pole, 25 and 30 contactors supplied without cover. See ccessories for cover options. ➎ Screw Power Terminals are supplied standard on 25 and 30 contactors. Box Lugs available by special order only in quantity. ➏ 1-Pole (1-pole plus) contactors include a shunt for termination and feed-thru of neutral. ➐ 40 mp contactors are supplied with cover as standard. Discount Schedule B8

Three Pole Definite Purpose Contactors with C Coil (Open Type only) Full Load mps Locked Rotor mps Resistive mps ➋ Maximum Horsepower ➋ 1Ø 3Ø 240V ➋ 480V 600V 120V 200 240V 200V 240V 480V 600V Catalog Number Definite Purpose Contactors Price Each 30 ➊ 180 150 120 40 2 ~ 5 10 10 15 20 CDP2-B3P30- ➍ 102 25 Std. Pkg. 3 Pole Series CDP2 40 240 200 160 50 3 ~ 7-1/2 10 10 20 25 CDP2-B3P40- ➌ 124 25 50 300 250 200 65 3 7-1/2 10 15 15 25 25 CDP2-C3P50-238 15 Series CDP2 3-pole contactor 60 360 300 240 75 5 7-1/2 10 25 25 30 30 CDP2-C3P60-276 15 75 450 375 300 93 5 10 15 20 25 40 40 CDP2-D3P75-360 1 90 540 450 360 120 7-1/2 15 20 25 30 50 50 CDP2-D3P90-498 1 uxiliary Contacts for 3 Pole Contactors uxiliary Description Circuit Diagram Catalog Number Price Two pole uxiliary Contact Block (1-NO / 1-NC) - Side mount with quick connect stabs for 25...40, 3 pole contactors NC CDP2-BE-11 ➏ 39.00 for 50...90, 3 pole contactors CDP2-CD-11 ➎ 40.32 NO One pole uxiliary Contact Block (SPDT) - Side mount with quick connect stabs for 25...40, 3 or 4 pole contactors COM NC CDP2-BE-1SPDT ➎ 34.42 NO C Coil Codes C Coil Code Voltage Range 60 Hz 24 24V 120 120V 220W 208-240V 277 277V 480 480V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ 25 contactors available by special order. Contact your Sprecher + Schuh representative. ➋ 240V rating also applies to 277V applications. ➌ Box lugs are supplied as standard. Screw terminals are available on the power connections by special order only in quantity. ➍ Screw power terminals are supplied standard on 25 and 30 contactors. Box Lugs available by special order only in quantity. ➎ Meets NEM Standard B600. See page 7 for technical details. ➏ Meets NEM Standard B600 EXCEPT has 10 continuous current rating. Discount Schedule B8 181

Four Pole Definite Purpose Contactors With C Coil (Open Type only) Full Load mps Locked Rotor mps 240V ➋ 480V 600V Resistive mps ➋ Maximum Horsepower ➋ 1Ø 3Ø 120V 240V 200V 240V 480V Catalog Number Price Each 30 ➊ 180 150 120 40 2 5 10 10 15 CDP2-E4P30-Q ➍ 118 20 Std. Pkg. Definite Purpose Contactors 4 Pole Series - CDP2 40 240 200 160 50 3 7-1/2 10 10 20 CDP2-E4P40-Q ➌ 137 20 Series CDP2 4-pole contactor uxiliary Contacts for 4 Pole Contactors uxiliary Description Circuit Diagram Catalog Number Price Two pole uxiliary Contact Block (1-NO / 1-NC) - Side mount with quick connect stabs for all 4 pole contactors NC NO CDP2-BE-11 12.30 One pole uxiliary Contact Block (SPDT) - Side mount with quick connect stabs for all 4 pole contactors COM NC NO CDP2-BE-1SPDT 19.50.C. Coil Codes C Coil Code Voltage Range 60 Hz 24 24V 120 120V 220W 208-240V 277 277V 480 480V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ 25 contactors available by special order. Contact your Sprecher + Schuh representative. ➋ 240V rating also apples to 277V applications. ➌ Box Power Lugs are supplied as standard. Screw terminals are available on the power connections by special order only in quantity. ➍ Screw per terminals are supplied standard on 25 and 30 contactors. Box Lugs available by special order only in quantity. 182 Discount Schedule B8

Definite Purpose Lighting Contactors with C Coil (Open Type only) Tungsten Rating (mps) Ballast Rating (mps) Number of Poles Standard uxiliary Contacts NO Electrically Held Open Type Catalog Number Price 30 40 1 0 0 CDP2-1P30-64.80 40 40 1 0 0 CDP2-1P40-82.50 30 40 2 0 0 CDP2-2P30-79.90 40 40 2 0 0 CDP2-2P40-96.10 30 40 3 0 0 CDP2-B3P30-102 40 40 3 0 0 CDP2-B3P40-124 30 40 4 0 0 CDP2-E4P30-118 40 40 4 0 0 CDP2-E4P40-137 NC Definite Purpose Contactors Lighting Rated Contactors - Series CDP2 Series CDP2 1-pole contactor Series CDP2 3-pole contactor Description Sprecher + Schuh Definite Purpose contactors can be used to control a mixture of lighting loads. These contactors are well suited to handle the high inrush currents typical of this application as well as other non-motor (resistive) loads. Lamps can basically be divided into three categories: Tungsten Filament Lamps - General purpose incandescent - Special purpose incandescent - Infrared - Sodium Iodine Discharge Lamps (with Ballast) - Fluorescent lamps - Mercury vapor - High/low pressure sodium - Quartz - Halogen metal-vapor Mixed Light Lamps In pplication... The tungsten filaments of incandescent lamps have a very low ohmic resistance when cold. s a result, the closing current is very high but also very short. The closing current of discharge lamps (lighting with ballast) is highly inductive (due to seriesconnected transformers or chokes), and its duration depends on the lamp type. Electrically held contactors Electrically held contactors are available for use where the control signal is activated by a timer or other maintained electrical signal. The coil is energized as long as the contactor is closed. This design is well suited for applications where lights are operated frequently or where the control panel is in a remote location. C Coil Codes C Coil Code Voltage Range 60 Hz 24 24V 120 120V 220W 208-240V 277 277V 480 480V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page Discount Schedule B8 183

ccessories/technical Information Series CDP2 Definite Purpose Contactors ccessories uxiliary Description For use with... Catalog Number Price DIN-rail daptor - ttaches to the universal mounting plate of 1-, 2-, 3- and 4-pole contactors 25...40 mps. CDP2-1P B3P CDP2-E4P CDP2-DR Mechanical Interlock - Can be combined with electrical interlocks on 3-pole and 4-pole contactors as required. CDP2-B3P CDP2-E4P CDP2-MK1 184 Discount Schedule B8

Short-Circuit Coordination 25-30 1+2-Pole 40 1+2-Pole 25-30 3-Pole 40 3-Pole Technical Information Series CDP2 Definite Purpose Contactors 50-90 3-Pole 25-30 4-Pole Standard Short Circuit Rating [k] 5 5 5 5 5 5 5 High Current Short Circuit Rating Class J-fuses vailable fault current [k] 100 100 100 100 ➊ 100 100 cul Max. fuse (600V) [] 60 100 60 100 ➊ 50 100 Enclosure Minimum [in 3 ] 96 96 144 144 ➊ 144 144 Molded Case Circuit Breaker vailable fault current [k] 100 100 100 100 ➊ 100 100 cul Max. breaker (480V) [] 80 80 80 100 ➊ 80 100 Enclosure Minimum [in 3 ] 144 144 144 144 ➊ 144 144 40 4-Pole Service Life Mechanical (operations) 1,000,000 1,000,000 1,000,000 1,000,000 500,000 1,000,000 1,000,000 Electrical (operations) Resistive Load (UL) 250,000 250,000 250,000 250,000 6,000 ➌ 250,000 250,000 Inductive Load (UL) 100,000 100,000 100,000 100,000 6,000 ➍ 100,000 100,000 Inductive Load (Self-certified) 200,000 200,000 200,000 200,000 200,000 200,000 200,000 Data for Surge Suppression Selection Contactor Configuration (ll voltages) Resistor Capacitor Snubber ➋ 1 Pole 680 ohms 0.47 nƒ RCS1M-6 2 Pole 330 ohms 0.47 nƒ RCS1K-6 3P 30/40 mp 220 ohms 0.47 nƒ RCS1-6 4P 30 mp 220 ohms 0.47 nƒ RCS1-6 3P 50/60 mp 150 ohms 0.47 nƒ RCS1H-6 3P 75/90 mp 68 ohms 0.47 uƒ RCS1E-6 ➊ UL testing not complete at the time of this printing. ➋ Recommended snubbers from RK Electric. ➌ UL File update to 250,000 pending at the time of this printing. 250,000 Self-certified at this time. ➍ UL File update to 100,000 pending at the time of this printing. 185

Technical Information Series CDP2 Definite Purpose Contactors General Specifications CDP2 CDP2 CDP2 CDP2 CDP2 pprovals UL 25...40, 1 & 2 pole 25...40, 3 pole 50...60, 3 pole UL508, Guide No. NLDX2-File No. E3125 75...90, 3 pole CS C22.2 No. 14, Class; 321104-File No. 210566 (75, 3 pole / C22.2 No. 14, Class: 122201 - File No. 210566) CE / SEMKO Certified EN60947-4-1: 2010 IEC IEC 947-4-1 (Except 50 90, 3 pole) CCC Registration # 2005010304145109 (Except 50 90, 3 pole) 25...40, 4 pole Line and Load Terminals #10-32 screw or box lug #10-32 screw or box lug Box lug Box lug #10-32 screw or box lug Wire Size (min/max) #10-32 screw (all 25 & 30) [WG] 16-8 ➊ 16-8 ➊ ~ ~ 16-8 ➊ Box Lug (>40) [WG] 14-4 Cu/I 14-4 Cu/I 14-2 Cu/I 14-1/0 Cu/I 14-4 Cu/I Recommended Tightening Torque #10-32 screw (all 25 & 30 devices) 22 lbs-in 22 lbs-in ~ ~ 22 lbs-in Box Lug (40 devices only) 40 lbs-in 40 lbs-in 50 lbs-in 50 lbs-in 40 lbs-in Quick Connects Coil Terminals Dual.250 QC (2) Quad..250 QC (2) #6-32 screw 7.250 QC (2) #6-32 screw 7.250 QC (2) Dual.250 QC (2) Power Terminals 1 pole: Quad.250 QC Dual.250 QC (2) Dual.250 QC (2) Dual.250 QC (2) Dual.250 QC (2) 2 pole: Quad.250 QC rc Cover Optional Standard Standard Standard Standard Insulation System 130 C Class B Temperature Range [ C] -40 C to +65 C [ F] -40 F to +150 F Weight 1 pole 0.5 lb 2 pole: 0.6 lb 1 lb 2 lbs 4 lbs 1.5 lbs. UL/CS Ratings for 25 special order contactors 1 Pole 2 Pole 3 Pole Locked Rotor mps 240/277 V [] 150 150 150 480V [] 125 125 125 600V [] 100 100 100 Resistive mps [] 35 35 35 120 V [HP] 2 2 2 Max. HP 1 240 V [HP] 3 3 3 200 V [HP] ~ ~ 7.5 230 V [HP] ~ ~ 7.5 3 460 V [HP] ~ ~ 10 575 V [HP] ~ ~ 10 Coil Data 1 Pole Contactors (25...40) 24V Coils 120V Coils 220W Coils 277V Coils 480V Coils Normal Coil Voltage [V] 24 120 208 / 240 277 ~ Pickup voltage (min.) [V] 18 88 177 221 ~ Drop-out/Voltage Range [V] 6...15 20...70 40...140 50...165 ~ Nominal Inrush ~ 50 Hz [V] 22.5 22.5 22.5 22.5 ~ 60Hz [V] 20 20 20 20 ~ Nominal Seal-in ~ 50 Hz [V] 7 7 7 7 ~ 60 Hz [V] 5.25 5.25 5.25 5.25 ~ Nominal DC Resistance [Ω] 16.5 420 1850 2650 ~ 2 Pole Contactors (25...40) ~ Normal Coil Voltage [V] 24 120 208 / 240 277 ~ Pickup voltage (min.) [V] 18 88 177 221 ~ Drop-out Voltage Range [V] 6...15 20...70 40...140 50...165 ~ Nominal Inrush ~ 50 Hz [V] 37 37 37 37 ~ 60Hz [V] 35 35 35 35 ~ Nominal Seal-in ~ 50 Hz [V] 8 8 8 8 ~ 60 Hz [V] 7 7 7 7 ~ Nominal DC Resistance [Ω] 11 250 1000 1600 ~ ➊ Stranding must be split for #8 wire. 186

Coil Data (continued) 50/60 Hz 24V Coils 110-50 Hz 120-60 Hz 120V Coils 220-50 Hz 208-240 - 60 Hz 220W Coils Technical Information Series CDP2 Definite Purpose Contactors 277-60 Hz 277V Coils 440-50 Hz 480-60 Hz 480V Coils 3 Pole Contactors (25...40) Nominal Coil Voltage [V] 24 120 208-240 277 480 Pickup Voltage (min.) [V] 18 88 177 220 384 Drop-out Voltage Range [V] 6...15 20...70 40...140 50...165 150...270 Nominal Inrush 50 Hz [V] 65 65 65 65 65 60Hz [V] 60 60 60 60 53 Nominal Seal-in 50 Hz [V] 7.5 7.5 7.5 7.5 7.5 60 Hz [V] 6 6 6 6 6 Nominal DC Resistance [W] 7 180 720 950 3100 3 Pole Contactors (50...60) Nominal Coil Voltage [V] 24 120 208-240 277 480 Pickup Voltage (min.) [V] 18 88 177 221 374 Drop-out Voltage Range [V] 6...15 20...70 40...140 65...185 120...286 Nominal Inrush 50 Hz [V] 114 108 126 120 98 60Hz [V] 105 105 125 115 108 Nominal Seal-in 50 Hz [V] 13 12 14 13 10 60 Hz [V] 12 11 13 1 10 Nominal DC Resistance [W] 4 52 282 453 1390 3 Pole Contactors (75...90) Nominal Coil Voltage [V] 24 120 208-240 277 480 Pickup Voltage (min.) [V] 22 95 177 235 384 Drop-out Voltage Range [V] 6...15 20...70 40...110 65...185 150...270 Nominal Inrush [W] 50 Hz [V] 225 225 280 210 210 60Hz [V] 222 220 270 202 202 Nominal Seal-in 50 Hz [V] 22 19 27 27 19 60 Hz [V] 21 18 25 25 18 Nominal DC Resistance [W].66 15.8 50 93 258 4 Pole Contactors (25...40) Nominal Coil Voltage [V] 24 120 208-240 277 480 Pickup voltage (min.) [V] 18 88 177 220 384 Drop-out Voltage Range [V] 6...15 20...70 40...140 65...185 15...270 Nominal Inrush 50 Hz [V] 62 62 62 62 67 60 Hz [V] 59 59 59 59 60 Nominal Seal-in 50 Hz [V] 9 9 9 8 9 60 Hz [V] 7 7 7 6.5 7 Nominal DC Resistance [W] 6 150 600 750 2400 Operating Times C: 50Hz, 60hz Pick-up [ms] 0...20 0...20 0...20 0...20 0...20 Drop-out [ms] 0...30 0...30 0...30 0...30 0...30 uxiliary Contacts 2 Pole (NO/NC) - Single Circuit Contact Rating Voltage Rating 120 240 480 600 Break 3.0 1.5 0.75 0.6 mperes Make 30 15 7.5 6 Continuous 10 10 10 10 SPDT 10, 1/3 HP, 125 or 250V C; 1/2, 125 V DC; 1/4, 250V DC; 4, 120V C on Lamp Load 187

Dimensions Series CDP2 Definite Contactors 1-Pole CDP2 25...40, 1 & 2 Pole Dimensions are in inches (millimeters). Dimensions not intended for manufacturing purposes. 2-Pole CDP2 25...40, 3 Pole with uxiliary 188

Dimensions Series CDP2 Definite Purpose Contactors CDP2 50...60, 3 Pole with uxiliary Dimensions are in inches (millimeters). Dimensions not intended for manufacturing purposes. CDP2 75...90, 3 Pole with uxiliary 189

Dimensions Series CDP2 Definite Purpose Contactors CDP2 25...40, 4 Pole with uxiliary Dimensions are in inches (millimeters). Dimensions not intended for manufacturing purposes. CDP2-MK1 Mechanical Interlock Terminations 190