actions. 12 digital outputs can be assigned to 4 different types of events (MODE, Alarm, Time and PV) 32 Programs, 800 segments

Similar documents
UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

DCP100 Digital Control Programmer Specifications

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

SCALE & WEIGHT DISPLAYS

LAUREL ELECTRONICS, INC.

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Hybrid Chart Recorder 250 mm (10")

Wall-/Pipe-Mount Level Indicator

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

AF-300 E11 Adjustable Frequency Drive

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

EVENT INPUT/OUTPUT MODULE [PUME]

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Humidity and Temperature Controllers (Product Code To ) DTH-966 with HYGROTX

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

USER S MANUAL. FX2N-8AD Analog input block

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

YS1000 Series. Compatible Type for Pneumatic 100 Line (with YS100 Terminal)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

Controllers, series CON Indicators, series IND. Controllers and indicators

Model IQ4-PC User Manual Revision Date:

Global Water Instrumentation, Inc.

DPR100 C/D Pen and Multichannel Recorder: Digital Display

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Pen and Multichannel Recorder: Digital Display

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

SY-HDBT-SLIM-100S Extender Set

ex 800 Series ematrix System

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Quick Operation Guide of LTN7700/7600 Series NVR

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

Standard RS232 RS ma

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

AHP-1200CPV Cold/Warm Plate Product Manual Volume 1.3

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

ADJUSTABLE SPEED DRIVES. nc1 Drive

FOM-9010, FOM-9011 and FOM-9012

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Solid-State Digital Timer

Solution Selection Guide

2 MHz Lock-In Amplifier

Section C Recorders. DPR mm Digital Strip Chart Recorder

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

INST No.CP CP Computing unit. Instruction Manual. Important Notice. Keep this manual with due care after understanding operation.

LARGE DIGITAL TEMPERATURE LED DISPLAYS

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

ED5229GT-E Series. Page 1 of 8

TempScan/1100 & MultiScan/1200

ED5229GT-E/GTRE Series

Model Number Structure

Automatic Transfer Switch Control PLC Operator s Manual

Process Transmitter RMA 422

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Multifunction devices

User s Manual. Digital Media Converter Package Part #: DL-HDCAT

263 Series LED Bargraph Indicator and Controllers

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

HOBO H Energy Logger

SXT SXGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Micro-DCI 53ML5100 Manual Loader

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

16-BIT LOAD CELL/DUAL STATUS INPUT

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

JENCO ELECTRONICS, LTD.

HS-509 VIBRATION TRIP MODULE

Standard signal metering in wall-mounting case

MICROMASTER Encoder Module

Durable and Reliable Design for 24/7 Use. Overview. Narrow Bezel Optimized for Video Walls. 42 Narrow bezel commercial LED display

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

FP93 Program Controller

Operating instructions Electronic preset counter Type series 717

TC3301. User's Manual

02/11/2015

Gamma instabus. Technical product information

The Art of Engineering

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

PRINCIPLES AND APPLICATIONS

SIMATRIX NEO V2 Modular Video Matrix

Transcription:

05/06 30-08-10-05-EN Page 1 of 14 IPC5000 S/D Universal Programmer Specification Overview The IPC5000 is a high-functional Single or Dual loop programmer retaining all the reliability, simplicity, and compatibility. This programmer is operated by touchscreen in 5.7 inch LCD monitors and controls in various kinds of applications such as: Furnace & Industrial Oven Autoclave Test Chamber Environmental Room / Clean Room Retort Oven Pressure Cooker Dyeing Machine Reactor Features 5.7 inch LCD Touch Screen Configuration & operation will be done by touch screen function keys in graphic LCD display. Universal Input(s) Analog input(s) is a low-level type (s), which accepts Thermocouple, RTD, ma, voltage type. (See Table 1) 0.1% Input Accuracy Analog input(s) has typical accuracy of ± 0.1% of full-scale input. 12 DIs/12 Dos 12 points of digital inputs can be connected to non-voltage contact (relay contact) or open collector (sink current toward 0V), and they are allocated to predefined actions. 12 digital outputs can be assigned to 4 different types of events (MODE, Alarm, Time and PV) 32 Programs, 800 segments 32 Programs can be programmed within 100 segments for each and 800 segments in total. 10 Links are offered, and each Link can link up to 6 programs. Heat/Cool Capability Each control loop provides split range control with independent PID tuning constants one for heating, one for cooling plus mixed output forms. Ethernet Communication A communication link is provided between IPC5000 and a host computer or PLC via RS-485 (Modbus RTU) or Ethernet (Modbus TCP) communications option. IP65 Front Face Protection IP65 rated front face permits use in applications where it may be subjected to moisture, dust conditions. Asynchronous/Synchronous Mode In Dual-Channel type, two loop controls can be run independently with different program and also they can be operated simultaneously with one single program. Multi-Language Prompts 3 different languages will be selected via configuration and displayed. PC Configuration A free-ware will be offered and IPC5000 can be configured and operated thru this software on PC. Real Time Clock IPC5000 provides accurate time and makes it possible to schedule running operation.

Specifications Display Model IPC5000S IPC5000D Digital Indication & Display Display Type Screen Size (Unit: mm/inch) Resolution 5.7 inch LCD (STN Negative, Blue) 115.17 86.37 ( W ) ( H ) 4.534 3.4 320(W) x 240(H) Back Light LED, White (Luminous Intensity: 20cd/m 2 ) Display Size Display Color Display Language Cap. 40 lines x 30 lines (8x8 dots characters) Blue characters on white background Up to 3 languages Operation Analog touch panel (Actuation force: 10g 80g) General Rated Power Supply Voltage Inrush Current when power supply turns on Insulation Resistance Withstand Voltage 100 to 240V AC 50/60Hz, 37VA Max. Lower than 50 A Higher than 50MΩ under DC 500V megger during power terminal and PE terminal 1500V AC 50/60Hz for 1min across power terminal and PE terminal Ambient Temperature 23 ± 2 C Reference Relative Humidity Power Voltage (Vac) Power Frequency 60 ± 5% RH 110V AC 50 ± 1Hz or 60 ± 1HZ Vibration Resistance 0 m/s 2 Ambient Temperature 0 to 50 C Operative Limits Relative Humidity Power Voltage (Vac) Power Frequency Vibration Resistance 10 to 90%RH (non-condensing) 85 to 264V AC 50 ± 2Hz or 60 ± 2Hz 0 to 1.96m/s 2 (10 to 60Hz in X, Y, Z directions for 2 hours each) Transportation & Storage Exterior Mounting Ambient temperature -20 to +70 C Relative Humidity 10 to +95% RH (non-condensing) Vibration Resistance 0 to 1.96m/s 2 (10 to 60Hz in X, Y, Z directions for 2 hours each) Case and front panel: plastic Panel-mount Exterior Size (unit: inch Panel Cutout (unit: inch mm ) 196 131 154 ( W ) ( H ) ( D ) 7.717 5.157 6.063 mm ) 185.5 ± 0.5 120.5 ± 0.5 ( W ) ( H ) 7.303 ± 0.02 4.744 ± 0.02

Specifications Input & Output Model IPC5000S IPC5000D Analog Input Number of point 1 point (Universal input) 2 points (Universal input) TC RTD : K, J, R, S, B, E, T, N (JIS/IEC), W, C : Pt100 (JIS/IEC), JPt100 (JIS) Type Linear : VOLTAGE 0~10V, 0~5V, 1~5V CURRENT 0 ~ 20mA, 4 ~ 20mA (For details, refer to Table 1-1) Sampling Rate Indication Accuracy Cold junction accuracy Input bias Digital filter Square-root Extraction 100 ms ±0.1%FS ± 1digit (Accuracy is variable according to input type or range) ±1.0 ºC (under standard conditions) -99.9 ~ +99.9 variable 0 ~ 120 sec (0: filter off) Low-cut: 0.1~5.0% of input (in case of voltage input from orifice or pressure sensor) Linearity / Approximation (1) Segment break-point: 1 to 10 of total range (2) Linearity Compensation Bias : -10000.0 ~ 10000.0 Compensation Set : -5.0~105.0% of input range span (3) Approximation Bias : -5.0~105.0% of input range span Compensation Set : -5.0~105.0% of input range span Analog Output Object PV1, SP1, MV1, DEV1 PV1, SP1, MV1, PV2, SP2, MV2, DEV 1/ 2 (Transmission output) : Optional Digital Inputs (External switch input) Output type Output accuracy Update Rate Number of point Connectable type Allocation (Fixed) 4~20mA DC +/- 0.1% of span 100 ms 12 points No-Voltage contact (relay contact) Open collector (sink current toward 0V) RUN/STOP, HOLD, ADV, Trouble inputs, Program number (For details, refer to Table 1-2) Trouble input 4 points 2 points Trouble message Sampling cycle 32 messages (Each trouble can have its message), Max. 22 characters 100 ms

Specifications Input & Output Model IPC5000S IPC5000D Digital Output (Event Output) Number of point Output Type External supply voltage Max. load current Time Event Event Code Object PV Event 12 points Open collector MAX DC30V MAX 100mA/1ch Code 0 (OFF), Code 1 (ON), Code 2 (On-Delay & Cut-Back) Segment Time Event code Code 11 Code 38 Object Operating point Operating Condition Set Point (SP) / Process Variable(PV) Destination(Target) Value (DV) / Manipulated value (MV) Absolute value (ABS) / Deviation (DEV) / MAX, MIN value Band / LOW/HIGH Range Absolute Deviation Differential -19999.0~20000.0 Unit -19999.0~20000.0 Unit 0 ~ 1000.0 Unit On delay time 0 ~ 99 sec Mode Event Event code Code 41 Code 60 Object RUN, HOLD, ADV, WAIT, MAN, TUNE, READY, FIX, STOP, END, TRBL, DOWN, UP Alarm Event Event Code Code 61 Code 80 INNER : Object = PV, SP, DV, MV Object Range DIAGNOSIS FAIL Operating point = ABS, DEV, MAX & MIN value Operating condition = Band/LOW/HIGH : Same with PV Event : PV input burn-out : Instrument fail (Type: Memory, Power failure) Auxiliary Analog Input : Optional Action Number of point Input type Sampling Rate Input accuracy RUN: Operation in RUN mode ALL: Operation in all cases 1 point ma (4~20mA), V (0~10V, 1~5V) 200 ms ±0.3%FS ± 1digit * The analog input option has no functional assignment, available for future purpose only.

Specifications Model IPC5000S IPC5000D Program Max. Program Number 32 programs (No. 0 ~ No. 31) Max. Segment Number 100 segments/1 program & total 800 segments Segment Setting Segment Time : Setting by set points (SP) and time (Max. 99hours59min or 99min59sec) Segment Ramp-rate : Soaking-segment ramp rate (hr.min/min.sec) * Time unit is switcheable Ascending/descending ramp (Slope per hour/min) Ramp rate: 0.0 to 9.9 PID Group Setting (1) Segment PID (2) Zone PID Group No.: 1 to 8 Junction Code 0: Shifting to next segment 1: Holding when the segment completed 2: Transmitting to FIX control when last segment completed in the program WAIT Function Repeat Type (Front, rear, all) and WAIT width 1 pattern all repeat x 1 (Maximum repeat is 999 cycle) Part repeat x 5 (Maximum repeat is 999 cycle) Program Start Mode - SSP Start from a preset point (SSP1 or SSP1/SSP2) to the target set point of the first segment - SPV Start from the point determined by the PV position compared with the target set points of program - Time Start from PV to the target set point of the first segment Program Link Maximum 6 patterns Link program registration: Maximum 10 links Program Name 32 programs (Each program can have its name), Max. 12 characters FIX Control Ramp (Slope) Ramp Time : Max. 9999 hours 59minutes or 9999 minutes 59 seconds Ramp Rate : 0.0 to 9.9 G. SOAK Type (Front, Rear, All) and WAIT width Event Set PV Event Set : 11 to 38 Power Failure Controls right away after recovery of power failure, if the power failure lasts less than 7 seconds. For power failure that lasts longer than 4 seconds, setup modes below will be followed. BREAK: Stops program HOT START: Controls at the state just before power failure COLD START: It starts again at the beginning of program (Note) In fix control, it is HOT START if the TIMER is off.

Specifications Control Model IPC5000S IPC5000D PID Algorithm Proportional Band (P) Integral Time (I) Derivative Time (D) Manipulated Value Limit (MV) PID-A / PID-B / DUP-A / DUP-B Proportional Band: 0.1 ~ 9999% GAIN: 0.001 ~ 1000 0.00 ~ 10.00 min 0.02 ~ 50.00 min Low-limit: -5.0 to High-limit% High-limit: Low-limit to +105.0% Manual Reset 100 to +100 Maximum PID groups 8 groups Loop 1 : 0 groups, 8 groups Loop 2 : 0 groups PID Group Selection Segment specified, Automatic zone selectable during program run Accutune II: Automatic setting of PID value by limit cycle method. Auto Tuning * Single Auto tuning Auto tuning with specified PID group number * Automatic Auto tuning Zone PID 1 to Zone number Segment PID 1 to 8 PID group number Fuzzy Control Function Fuzzy Control function On-off Control Diff. 0 ~ 1000 Control Direction Selection is settable (Direct/Reverse) HEAT/COOL Control HEAT/COOL available HEAT/COOL available for each CH Operation Mode Auto/Manual operation is switcheable *Manual Output: i) Bumpless ii) Preset value: -5.0~105.0% Output Output Set TYPE Provided with 9 types (refer to Table1-3) Signals 4~20mA DC Current Accuracy +/-0.1% of span Update cycle 100 msec Voltage Pulse Open Time Terminal Voltage Lower than 15V DC (20mA) (PWM) Time Proportional Cycle 1 ~ 240 sec Relay Signal NC, NO, and common terminals (SPDT) Contact Contact Rating 250VAC, 3A or 30VDC, 3A (Resistance load) Open Collector External Supply Voltage Max. Load Current MAX DC30V MAX 100mA/1ch

Specifications Control Operation Model IPC5000S IPC5000D READY RUN Stand-by status before program start (Control stop) Program running status * Program Start Quick Start by RUN/STOP key or external contact relay input Program HOLD WAIT END BREAK TUNE READY RUN Timer Start by scheduled time Status to hold program run by force Waiting status during the WAIT function enabled Status after program completed (Control stop) POWER FAILURE or Stop status (Control stop) AUTO-TUNING status Stand-by status before program start (Control stop) Program running status * Program Start Fix Control Quick Timer Start by RUN/STOP key or external contact relay input Start by scheduled time HOLD TUNE Status to hold program run by force AUTO-TUNING status Communication Speed 9600 or 19200 RS-232 Parity check NONE (Basic) Bit length 8 Stop Bits 1 Communication RS-485 (Option) Data Bits per Character Bit transfer order End of message LSB first Idle line for three or more characters (>1.82 msec). Protocol Modbus TCP Ethernet (Option) Port Cabling Type One 10Base-T(RJ-45 connector) UTP category 2 or better Note) UTP: Unshielded Twisted Pair cable

Table 1 Input Actuations Input type Input Code Range ºC ºF Measurement Accuracy K1-200.0~200.0-328.0~392.0 +/-0.1%FS Below 0ºC: +/-0.2%FS K (CA) K2 0.0 ~ 1200.0 32.0~2192.0 +/-0.1%FS K3 0.0~800.0 32.0~1472.0 +/-0.1%FS Thermocouples K4 0.0~400.0 32.0~752.0 +/-0.1%FS J (IC) J 0.0~800.0 32.0~1472.0 +/-0.1%FS R R 0.0~1600.0 32.0~2912.0 +/-0.1%FS S S 0.0~1600.0 32.0~2912.0 +/-0.1%FS B B 0.0~1800.0 32.0~3272.0 +/-0.1%FS E (CRC) E 0.0~800.0 32.0~1472.0 +/-0.1%FS +/-4.0%FS at 0 to 260ºC +/-0.15%FS at 260 to 800ºC T (CC) T -200.0~300.0-328~572 +/-0.1%FS +/-0.3%FS at 200 to -45ºC N N 0.0~1300.0 32~2372 +/-0.1%FS W W1 0.0~1200.0 32~2192 +/-0.1%FS W2 0.0~2300.0 32~4172 +/-0.1%FS C C 0.0~2300.0 32~4172 +/-0.1%FS Pt1-200.0~500.0-328.0~932.0 +/-0.1%FS Pt2-200.0~200.0-328.0~392.0 +/-0.1%FS Pt3-100.0~150.0-148.0~302.0 +/-0.1%FS Pt100 (JIS/IEC) Pt4-50.0~200.0-58.0~392.0 +/-0.1%FS Pt5-40.0~60.0-40.0~140.0 +/-0.2%FS Pt6 0.0~100.0 32.0~212.0 +/-0.2%FS Pt7 0.0~300.0 32.0~572.0 +/-0.1%FS RTD Pt8 0.0~500.0 32.0~932.0 +/-0.1%FS JPt1-200.0~500.0-328.0~932.0 +/-0.1%FS JPt2-200.0~200.0-328.0~392.0 +/-0.1%FS JPt3-100.0~150.0-148.0~302.0 +/-0.1%FS JPt100 (JIS) JPt4-50.0~200.0-58.0~392.0 +/-0.1%FS JPt5-40.0~60.0-40.0~140.0 +/-0.2%FS JPt6 0.0~100.0 32.0~212.0 +/-0.2%FS JPt7 0.0~300.0 32.0~572.0 +/-0.1%FS JPt8 0.0~500.0 32.0~932.0 +/-0.1%FS 0~10V DCV1 +/-0.1%FS DC Voltage DC Current 0~5V DCV2 Configurable Range +/-0.1%FS 1~5V DCV3-19999 ~ 20000 +/-0.1%FS 0~20mA MA1 (DP position is configurable) +/-0.1%FS 4~20mA MA2 +/-0.1%FS

Table 2 The Function Table of External Switch Input (Digital Input) DI No. Function Detection way DI 01 RUN/STOP (RUN STOP) Leading edge DI 02 HOLD ON status DI 03 ADV Leading edge DI 04 Trouble Message Input 1 ON status DI 05 Trouble Message Input 2 ON status - IPC5000 Single Channel Type DI No. Function Detection way DI 06 Trouble Message Input 3 ON status DI 07 Trouble Message Input 4 ON status - IPC5000 Dual Channel Type DI 06 DI 07 Channel Selection OFF OFF Both CH1 and CH2 Disabled OFF ON CH1 Disabled, but CH2 Enabled ON OFF CH1 Enabled, but CH2 Disabled ON ON Both CH1 and CH2 Enabled - Program Selection DI 08 DI 09 DI 10 DI 11 DI 12 Pattern Selection OFF OFF OFF OFF OFF Select Program No. 00 OFF OFF OFF OFF ON Select Program No. 01 OFF OFF OFF ON OFF Select Program No. 02 OFF OFF OFF ON ON Select Program No. 03 OFF OFF ON OFF OFF Select Program No. 04 OFF OFF ON OFF ON Select Program No. 05 OFF OFF ON ON OFF Select Program No. 06 OFF OFF ON ON ON Select Program No. 07 OFF ON OFF OFF OFF Select Program No. 08 OFF ON OFF OFF ON Select Program No. 09 OFF ON OFF ON OFF Select Program No. 10 OFF ON OFF ON ON Select Program No. 11 OFF ON ON OFF OFF Select Program No. 12 OFF ON ON OFF ON Select Program No. 13 OFF ON ON ON OFF Select Program No. 14 OFF ON ON ON ON Select Program No. 15 ON OFF OFF OFF OFF Select Program No. 16 ON OFF OFF OFF ON Select Program No. 17 ON OFF OFF ON OFF Select Program No. 18 ON OFF OFF ON ON Select Program No. 19 ON OFF ON OFF OFF Select Program No. 20 ON OFF ON OFF ON Select Program No. 21 ON OFF ON ON OFF Select Program No. 22 ON OFF ON ON ON Select Program No. 23 ON ON OFF OFF OFF Select Program No. 24 ON ON OFF OFF ON Select Program No. 25 ON ON OFF ON OFF Select Program No. 26

DI 08 DI 09 DI 10 DI 11 DI 12 Pattern Selection ON ON OFF ON ON Select Program No. 27 ON ON ON OFF OFF Select Program No. 28 ON ON ON OFF ON Select Program No. 29 ON ON ON ON OFF Select Program No. 30 ON ON ON ON ON Select Program No. 31 Model Interpretation Instruction - Select the desired key number. The arrow to the right marks the selection available. - Make one desired selection each from Table I through III. A dot ( ) denotes unrestricted availability. KEY NUMBER Table I Table II Table III IPC5000 _ - - - _ KEY NUMBER Description Selection Control Loop Single Loop Control IPC5000S Dual Loop Control IPC5000D Availability TABLE I - Input & Outputs Input Standard Input (2 Analog Inputs + 12 Digital Inputs) 0 _ Standard Output (2 Analog Outputs + 12 Digital Outputs) _ 0 Output Standard Output + 2 Analog Outputs _ 1 TABLE II - Options Communication Manual & Cable RS-232C 0 _ RS-232C, RS-485 (Modbus RTU) 1 _ RS-232C, Ethernet (Modbus TCP) 2 _ None _ 0 Manual CD _ 1 Manual CD, RS-232C Cable (connection with PC) _ 2 TABLE III - Language Display Language English/Korean 0

External Dimension 196.0 7.717 mm (Unit: ) inch 131.0 5.157 13.0 0.512 140.7 5.539 119.0 4.685 185.5 ± 0.5 7.303 ± 0.02 120.5 ± 0.5 4.744 ± 0.02

Wiring Diagram - Single Channel (IPC5000S) <IPC5000S> [Note] 1. Open collector outputs are externally powered. 2. Two common terminals (DO_COM1 & DO_COM2) are disconnected each other. 3. Modbus & Ethernet connectors on the wiring diagram show the optional parts. If the communication is not selected, the communication feature will not be supported. No. Terminal name Function No. Terminal name Function No. Terminal name Function No. Terminal name Function 1 3 DI_COM DI2 Digital input2 1 3 DO_COM1 DO2 Digital output2 1 3 Output1(+) Output2(+) 4~20mA, 4~20mA, 2 4 DI1 DI3 Digital input1 Digital input3 2 4 DO1 DO3 Digital output1 Digital output3 2 4 Output1(-) Output2(-) Voltage Pulse Voltage Pulse 9 pin 8 pin 5 DI4 Digital input4 5 DO4 Digital output4 5 RDA 6 DI5 Digital input5 6 DO5 Digital output5 6 Not RDB 7 DI6 Digital input6 7 DO6 Digital output6 7 Connected 5 pin SDA 8 DI_COM 8 DO_COM2 8 SDB 9 DI7 Digital input7 9 DO7 Digital output7 9 Input1 (+) RTD(A),mA,V,TC SG 10 DI8 Digital input8 10 DO8 Digital output8 10 Input1 (-) RTD(b) 11 DI9 Digital input9 11 DO9 Digital output9 11 Input1(B) RTD(B) 12 DI10 Digital input10 12 DO10 Digital output10 12 13 DI11 Digital input11 13 DO11 Digital output11 13 14 DI12 Digital input12 14 DO12 Digital output12 14 15 15 N.C. 15 Terminal name Function Not 16 16 N.O. Relay 1 16 Connected L 100Vac to Main 17 Not 17 COM 17 N 240Vac Power supply 18 Connected 18 N.C. 18 Protective Earth Connect the PE 19 19 N.O. Relay 2 19 (PE) to Frame Ground 20 20 COM 20 D-sub connector (9 pin) RJ-45 connector (8 pin) RS232 (default) Ethernet (option) RS485(Modbus) (option)

- Dual Channel Type (IPC5000D) No. Terminal name Function No. Terminal name Function No. Terminal name Function No. Terminal name Function 1 3 DI_COM DI2 Digital input2 1 3 DO_COM1 DO2 Digital output2 1 3 Output1(+) Output2(+) 4~20mA, 4~20mA, 2 4 DI1 DI3 Digital input1 Digital input3 2 4 DO1 DO3 Digital output1 Digital output3 2 4 Output1(-) Output2(-) Voltage Pulse Voltage Pulse 9 pin 8 pin 5 DI4 Digital input4 5 DO4 Digital output4 5 Output3(+) AUX. Output RDA 6 DI5 Digital input5 6 DO5 Digital output5 6 Output3(-) (4~20mA) RDB 7 DI6 Digital input6 7 DO6 Digital output6 7 Output4(+) AUX. Output 5 pin SDA 8 DI_COM 8 DO_COM2 8 Output4(-) (4~20mA) SDB 9 DI7 Digital input7 9 DO7 Digital output7 9 Input1 (+) RTD(A),mA,V,TC SG 10 DI8 Digital input8 10 DO8 Digital output8 10 Input1 (-) RTD(b) 11 DI9 Digital input9 11 DO9 Digital output9 11 Input1(B) RTD(B) 12 DI10 Digital input10 12 DO10 Digital output10 12 Input2 (+) RTD(A),mA,V,TC 13 DI11 Digital input11 13 DO11 Digital output11 13 Input2 (-) RTD(B) 14 DI12 Digital input12 14 DO12 Digital output12 14 Input2(B) RTD(B) 15 15 N.C. 15 Input3(+) Terminal name Function AUX. Input(mA,V) 16 16 N.O. Relay 1 16 Input3(-) L 100Vac to Main 17 Not 17 COM 17 N 240Vac Power supply 18 Connected 18 N.C. 18 Not Connect the PE Protective Earth 19 19 N.O. Relay 2 19 Connected to Chassis ground 20 20 COM 20 D-sub connector (9 pin) RJ-45 connector (8 pin) RS232 (default) Ethernet (option) RS485 Modbus (option)

Warranty / Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications are subject to change without notice. Honeywell Process Solution IM&C Asia Pacific Honeywell Building 17 Changi Business Park Central 1 Singapore 486073 www.honeywell.com/imc