K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

Similar documents
Model Number Structure

Model Number Structure

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Multifunction Digital Timer

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Accessories (Order Separately)

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Self--powered Time Counter

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

H8GN. Model Number Structure. Ordering Information. Preset Counter/Timer (48 24) Model Number Legend. List of Models

K3MA Series. Digital Panel Meters K3MA-L K3MA-F K3MA-J. Frequency/Rate Meter. Process Meter. Temperature Meter INTRODUCTION

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

02/11/2015

Self-powered Totalizer

Weighing Meter. Ordering Information. Highly Functional Weighing Meter with Easy-to-read LED. Base Units

K3MA Series Digital Panel Meter USER MANUAL

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Self-powered Totalizer New H7E

Type Contact form Model

K3NX Process Meter OPERATION MANUAL

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Frequency/Rate Meter

Solid-State Digital Timer

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

Ordering Information. Self-Powered Tachometer H7ER. Subminiature Tachometers With Improved Appearance and Features. H Large display with 8.

Features. Digital Time Switch H5S. Easier and More Convenient to Use

Indoor Linear 80W Driver SI-C215280N2KR

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Operating Manual RISH OPTIMA VAF

Photoelectric Sensors E3F2

Input type NPN/Voltage pulse PNP 240 VAC

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

Process Transmitter RMA 422

USB-TG124A Tracking Generator User Manual

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

Digital Time Switch H5S. Features. Easier and More Convenient to Use

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

1X4 HDMI Splitter with 3D Support

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Installation Manual SaVi Note Underwater LED Light

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

OM2000N INSTALLATION MANUAL

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Solution Selection Guide

Model /29S RF Splitter

WLS27 Multicolor LED Strip Light with EZ-STATUS

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Specifications. Reference Documentation. Performance Conditions

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

Electronic converter for level transmitters MT03L Instructions manual

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

True RMS AC/DC Mini Clamp Meter

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Process transmitter RMA422

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

EZ-LIGHT K30L Series With Independent Push Button Contact

Magnecraft Power Relays

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

VideoSplitter HDMI 4K PT

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

CV-105. DVI & Audio to HDMI Converter. User Manual. Made in Taiwan

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

Model P/03P Upconverters

Transcription:

Temperature Meter CSM DS_E_11_2 Highly Visible LCD Display with 2-color (Red and Green) LEDs Wide input range - select from two types of platinum-resistance thermometers and ten types of thermocouples. Front-panel key operation for easy setting. Average processing function suppresses flicker. Temperature input shift and temperature unit selection functions. Easy confirmation of max/min display. Short 80-mm depth (measured from edge of face plate). Finger protective cover (standard equipment) protects against electric shock. Water- and dust-proof NEMA4X (IP66 equivalent) front panel. Recognized conform U.S. and Canadian requirements under the Component Recognition Program of UL. CE marking. Refer Safety Precautions for All Digital Panel Meters. For the most recent information on models that have been certified for safety standards, refer your OMRON website. Model Number Structure Model Number Legend -@ 1 2 3 1. Input Type L: Platinum-resistance thermometer or thermocouple 2. Output Type None: No output C: With relay contact output (SPDT) 3. Supply Voltage 100-240VAC: 100 240 VAC 24VAC/VDC: 24 VAC/VDC Ordering Information List of Models Input type Supply voltage Output Model Platinum-resistance thermometer or thermocouple 100 240 VAC None 100-240VAC 1 relay contact output (SPDT) -C 100-240VAC 24 VAC/VDC None 24VAC/VDC 1 relay contact output (SPDT) -C 24VAC/VDC 1

Accessories (Order Separately) Name Shape Model Splash-proof Soft Cover K32-49SC Hard Cover K32-49HC Watertight Cover Y92A-49N Rubber Packing K32-P1 Note: Rubber packing is provided with the Controller. Specifications Ratings 100-240VAC, -C 100-240VAC 24VAC/VDC, -C 24VAC/VDC Supply voltage 100 240 VAC 24 VAC (50/60 Hz), 24 VDC Operating voltage range Power consumption (under maximum load) Insulation resistance Dielectric strength Noise immunity Vibration resistance 85% 110% of the rated supply voltage 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) 20 MΩ min. (at 500 VDC) between external terminal and case. Insulation provided between inputs, outputs, and power supply. 2,000 VAC for 1 min between external terminal and case. Insulation provided between inputs, outputs, and power supply. ±1,500 V on power supply terminals in normal or common mode. ±1 μs, or 100 ns for square-wave noise with 1 ns. Vibration: 10 55 Hz, 0.35-mm half amplitude 5 min each in X, Y, and Z directions for 10 sweeps. ±480 V on power supply terminals in normal mode. ±1,500 V in common mode. ±1 μs, or 100 ns for square-wave noise with 1 ns. Shock resistance 150 m/s 2 (100 m/s 2 for relay contact outputs) 3 times each on 3 axes, 6 directions. Ambient temperature Operating: 10 C 55 C (with no condensation or icing) Srage: 25 C 65 C (with no condensation or icing) Ambient humidity Operating: 25% 85% (with no condensation) Approved safety standards UL61010-1, CSA C22.2 No.61010-1-04, conforms EN61010-1 (Pollution degree 2/overvoltage category II) Conforms VDE0106/P100 (finger protection) EMC (EMI) EN61326-1 Industrial electromagnetic environment Emission Enclosure: CISPR 11 Group 1 class A Emission AC Mains: CISPR 11 Group 1 class A (EMS) EN61326-1 Industrial electromagnetic environment Immunity ESD: EN61000-4-2: 4 kv contact discharge 8 kv air discharge Immunity RF-interference: EN61000-4-3: 10 V/m (amplitude-modulated, 80 MHz 1 GHz) Electrical Fast Transient Noise: EN61000-4-4: 2 kv (power line) Immunity Burst Noise: 1 kv line line (I/O signal line) Immunity Surge: EN61000-4-5: 1 kv (power line) 2 kv line ground (power line) Immunity Conducted Disturbance: EN61000-4-6: 3 V (0.15 80 MHz) Immunity Voltage Dip/Interrupting: EN61000-4-11: 0.5 cycle, 0, 180, 100% (rated voltage) Weight Approx. 200 g 2

Characteristics Indication accuracy (at 23±5 C) (See note.) Input Note: The indication accuracy of the K thermocouple at a temperature of 200 1300 C is ±2 C ±1 digit maximum. The indication accuracy of the T and N thermocouples at a temperature of 100 C or less is ±2 C ±1 digit maximum. The indication accuracy of the U and L thermocouples at any temperature is ±2 C ±1 digit maximum. The indication accuracy of the B thermocouple at a temperature of 400 C or less is unrestricted. The indication accuracy of the R and S thermocouples at a temperature of 200 C or less is ±3 C ±1 digit maximum. Measuring Ranges Platinum-resistance Thermometer Thermocouple Input/Output Ratings Relay Contact Output Thermocouple: (±0.5% of indication or ±1 C, whichever greater) ±1 digit max. Platinum-resistance thermometer: (±0.5% of indication or ±1 C, whichever greater) ±1 digit max. Thermocouple: K, J, T, E, L, U, N, R, S, B Platinum-resistance thermometer: JPt100, Pt100 Double integral method 500 ms Sampling period (sampling times multiplied by number of averaging times if average processing is selected.) Measurement method Sampling period Display refresh period Max. displayed digits 4 digits (1999 9999) Display 7-segment digital display, Character height: 14.2 mm Polarity display is displayed aumatically with a negative input signal. Zero display Leading zeros are not displayed. Input shift Input shift equivalent the setting supported for all points within the sensor measurement range. Hold function Max hold (maximum ), Min hold (minimum ) Hysteresis setting Programmable with front-panel key inputs (0001 9999). Other functions Display color change (green (red), green, red (green), red) Average processing (simple average OFF/2/4/8 operations) Setting change lockout Parameter initialization Output Delay in comparative outputs Degree of protection Memory protection Relay contact (SPDT) 1 s max. Front panel: NEMA4X for indoor use (equivalent IP66) Rear case: IEC standard IP20 Terminals: IEC standard IP00 + finger protection (VDE0106/100) Non-volatile memory (EEPROM) (possible rewrite 100,000 times) (with terminal cover attached) Input Pt100 JPt100 Range C 200 850 199.9 500.0 0.0 100.0 199.9 500.0 0.0 100.0 F 300 1500 199.9 900.0 0.0 210.0 199.9 900.0 0.0 210.0 Parameter 0 1 2 3 4 Input K J T E L U N R S B Range C 200 1300 F 300 2300 20.0 500.0 0.0 900.0 100 850 100 1500 20.0 400.0 0.0 750 200 400 300 700 199.9 400.0 199.9 700.0 0 600 0 1100 100 850 100 1500 200 400 300 700 199.9 400.0 199.9 700.0 200 1300 300 2300 0 1700 0 3000 0 1700 0 3000 Parameter 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Item Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms) Rated load (UL ratings) 5 A at 250 VAC, 5 A at 30 VDC 1.5 A at 250 VAC, 1.5 A at 30 VDC Min. permissible load 10 ma at 5 VDC (P level, reference ) Mechanical life 20,000,000 times min. Electrical life 100,000 times min. 100 1800 300 3200 3

Connections Terminal Arrangement Power supply Models with A1 comparative E1 output A2 OUT1 E2 Output 100-240-VAC type or terminals 24-VAC/VDC type E3 (No polarity for 24-VDC connection.) E4 Input terminals + E5 E6 For thermocouple input A E4 B E5 B E6 For platinumresistance thermometer input A1 - A2 E4 E1 - E6 - E5, E2 - E3 Terminal No. Name Description Operation power Connects the operation power supply. Thermocouple or platinum-resistance thermometer input Outputs Connects the thermocouple or platinum-resistance thermometer input. Outputs the relay outputs. Block Diagram Input Input Key Microcomputer Display EEPROM 5 V 12 V Output circuit X Contact output (See note.) Constant voltage circuit Power supply circuit Note: Relay output models only. 4

Operation Main Functions Input Types and Ranges Parameter Setting Input type Meaning in-t 0 Platinum-resistance Pt100 200 850 C 300 1500 F 1 thermometer 199.9 500.0 C 1999 900.0 F 2 0.0 100.0 C 0.0 210.0 F 3 JPt100 199.9 500.0 C 199.9 900.0 F 4 0.0 100.0 C 0.0 210.0 F 5 Thermocouple K 200 1300 C 300 2300 F 6 20.0 500.0 C 0.0 900.0 F 7 J 100 850 C 100 1500 F 8 20.0 400.0 C 0.0 750.0 F 9 T 200 400 C 300 700 F 10 199.9 400.0 C 199.9 700.0 F 11 E 0 600 C 0 1100 F 12 L 100 850 C 100 1500 F 13 U 200 400 C 300 700 F 14 199.9 400.0 C 199.9 700.0 F 15 N 200 1300 C 300 2300 F 16 R 0 1700 C 0 3000 F 17 S 0 1700 C 0 3000 F 18 B 100 1800 C 300 3200 F Note: The initial is 5: thermocouple K (200 1300 C/300 2300 F). Temperature Unit Selection Either centigrade ( C) or fahrenheit ( F) can be selected as the temperature unit. Parameter Setting Meaning d-u c Display in C. f Display in F. OUT Types (Comparative Output Models Only) OUT 1 can be set operate in one of the three following modes in accordance with the compared s: Upper limit (High Acting): The output is turned ON when the measurement is greater than its set. Lower limit (Low Acting): The output is turned ON when the measurement is less than its set. Upper and lower limits (Outside Band Acting): An upper limit (H set ) and lower limit (L set ) can be set independently. The output is turned ON when the measurement is greater than the upper-limit set or less than the lower-limit set. Parameter Setting Meaning out 1.t hi Upper limit: Alarm operates at upper limit. lo Lower limit: Alarm operates at lower limit. hi-lo Upper and lower limits: Alarm operates at upper and lower limits. Upper Limit (High Acting) Lower Limit (Low Acting) Upper and Lower Limits (Outside Band Acting) OUT1 Measurement Output ON OFF Hysteresis Measurement OUT1 Output ON OFF Hysteresis OUT1 upper-limit Measurement OUT1 lower-limit ON Output OFF Hysteresis Hysteresis 5

Temperature Input Shift Input shift equivalent the setting supported for all points within the sensor measurement range. Parameter ins -1999 9999 Temperature Before shift Setting Changing the Display Color The color of the displayed can be set either red or green. For comparative output models, the display color can be set change from green red, or from red green, according the status of the comparison criterion. OUT1 Green 192.0 Red 258.9 After shift Temperature input shift Parameter Initialization This function returns all of the parameters their initial s. Parameter Setting Meaning init off --- on Initializes all parameters. Use this reset the after returning it its facry-set condition. Average Processing Input Display Au-return Time This function aumatically returns the display the operation level s current if no keys are pressed for a preset time (called the display au-return time). Move--Protect-Level Time The time required shift the protect level can be set as desired. MAX/MIN Display The maximum and minimum measurement (display) s from the time the power is turned ON until the current time can be sred and displayed. This is useful, for example, when measuring the maximum. Current Average processing stabilizes displayed s minimize flicker by averaging the fluctuating input signals. Average processing can be performed for the measurement s in either of four steps (OFF, 2 times, 4 times, or 8 times). MAX/MIN LEVEL SHIFT UP Max MAX MAX/MIN MAX/MIN MAX/MIN LEVEL SHIFT UP This is useful for ignoring rapid fluctuations, e.g., eliminating spike noise. Hysteresis (Comparative Output Models Only) The hysteresis of comparative outputs can be set prevent chattering in the output when the measurement fluctuates finely near the OUT. Upper limit (high acting) Min MAX/MIN LEVEL SHIFT UP MIN MAX/MIN Set Hysteresis Measurement ON Output OFF 6

Nomenclature 2. Operation indicars 3. Level indicar 1 Max Min SV 1. Main indicar MAX/MIN LEVEL SHIFT UP 4. MAX/MIN key 5. Level key 6. Mode key 7. Shift key 8. Up key Name Functions 1. Main indicar Displays current s, parameters, and set s. 2. Operation 1 Lit when output 1 is ON. indica- SV Lit when a set is being displayed or changed. rs Max Lit when the main indicar is showing the MAX. Min Lit when the main indicar is showing the MIN. 3. Level indicar Displays the current level that the is in. (See below for details.) 4. MAX/MIN Key Used display the MAX and MIN s when a measurement is being displayed. 5. Level Key Used change the level. 6. Mode Key Used allow the main indicar indicate parameters sequentially. 7. Shift Key Used enable a set be changed. When changing a set, this key is used move along the digits. 8. Up Key Used change a set. Used set or clear a forced-zero function when a measurement is being displayed. p Not lit a s f Level indicar Level Protect Operation Adjustment Initial setting Advanced-function setting 7

Dimensions (Unit:mm) 101.2 91 Finger protective cover (provided) Main indicar character size Panel cut-out 120 min. A B C D E 14.2 mm 85 97 7.6 mm 75 min. 92 +0.5 0 96 12 1.3 48 80 44.8 45 +0.5 0 Mounting Recommended Panel Thickness 1 8 mm. Mount the product horizontally. MAX/MIN LEVEL SHIFT UP The uses M3 terminals. A terminal cover is provided. Application Examples Moniring the temperature of an industrial furnace Sending a temperature alarm for molding equipment Moniring the bearing temperature for a generar mor PID control Temperature Controler Generar mor Industrial furnace Molding Alarm equipment output Alarm output Alarm output Moniring the temperature of an industrial furnace/sintering furnace. Moniring/alarm function for disinfecting equipment. Moniring (failsafe checking) abnormal temperatures in molding equipment. Moniring the liquid temperature for cleaning devices. Moniring temperature rises in electric power generating facilities. Inspecting temperatures in machines and devices. 8

Installation 1. Insert the in the panel cut-out hole. 2. For a waterproof installation, insert the rubber gasket on the body of the. Wiring Precautions Use crimp terminals. Tighten the terminal screws a rque of approximately 0.5 N m. To avoid the influence of noise, route signal lines and power lines separately. Wiring Use the following M3 crimp terminals. 5.8 mm max. 5.8 mm max. 3. Fit the adapr in the grooves on the left and right sides of the rear case, then push it until it contacts the panel secure the. Unit Labels (Provided) The unit labels are not attached the. Select the desired labels from the provided sheet. LCD Angle of View The K3MA is designed provide the best visibility at the angles shown in the following diagram. Note: For scales and gauges, use the unit labels that are specified by the relevant laws or regulations. 10 30 Watertight Cover Y92A-49N Rubber Packing K32-P1 If the rubber packing is lost or damaged, it can be ordered using the following model number: K32-P1. (Depending on the operating environment, deterioration, contraction, or hardening of the rubber packing may occur and so, in order ensure the level of waterproofing specified in NEMA4, periodic replacement is recommended.) Note: Rubber packing is provided with the Controller. 9

Operating Procedures Operations in Run Mode Checking the Maximum and Minimum Values The maximum and minimum s can be displayed by pressing the MAX/MIN Key while the measurement is being displayed. Measurement MAX/MIN Key MAX MAX/MIN Key MIN MAX/MIN Key The maximum and minimum s can be reset by pressing the MAX/MIN Key for 1 s min. when the maximum or minimum is displayed. Checking and Setting Comparative Set Values (for Models with the Comparative Output Function) Each time the Mode Key is pressed when the measurement, maximum, or minimum is displayed, the comparative s will be displayed in the following order: OUT1 (or OUT1 upper-limit, OUT1 lower-limit ). Adjustment Level Operation Setting Temperature Input Shift Values Temperature Input Shift A shift can be set for a temperature input. Temperature After shift Input shift Before shift Measurement MAX MIN Mode Key OUT1 upperlimit OUT1 Mode Key OUT1 lowerlimit Mode Key Input The set for the temperature input shift is applied the entire measurement range of the temperature sensor. 10

Levels Level refers a grouping of parameters. The following table lists the operations that are possible in each of the levels, and the diagram tells how move between levels. There are some parameters that are not displayed for certain models. Level name Function Measurement Protect Setting lockouts. Continue Operation Displaying current s, and setting OUT 1. Continue Adjustment Setting communications writing control. Continue Initial setting Advanced-function setting Making initial settings of input type, output operating action, and other parameters. Setting average processing, display color settings, and other advanced function parameters. Spped Spped Power ON + Time set by user (See note.) Operation level 1 s min. Adjustment level Less than 1 s Flashing sps if key is released. Protect level + 1 s min. 1 s min. - 123.4 Indicates change of level. Continue press the key for 2 s min. Initial setting level 1 s min. Password "0169" Advanced-function setting level Note: The move--protect-level time can be set in the advanced-function setting level. 11

Parameters Note: 1. Some parameters are not displayed for certain models. 2. The will sp measurement if the level is changed the initial setting level or the advanced-function setting level. 3. If the input range is changed, some parameters are set default s. Therefore, set the input range first. 4. Settings displayed in reversed colors are defaults. Power ON Adjustment level Press Level Key for less than 1 s. Press Level Key for less than 1 s. Operation level Current 0 Temperature input shift For models with the comparative output function OUT1 Set one of these. OUT1 upper-limit OUT1 lower-limit 12

Press Level Key for more than 3 s. Press Level Key for more than 1 s. Models with the comparative output function Initial setting level Input type Temperature unit OUT1 type Move advancedfunction setting level To change a setting, press the Shift Key make the change with the Up Key. Press Level Key for less than 1 s. Temperature unit OUT1 type Upper Limit Lower Limit Upper/Lower Limits Password: 0169 Enter password "0169" Models with the comparative output function again, and then Advanced-function setting level Parameter initialization Average processing OUT1 Hysteresis Display color change / / / / Unit: times OUT1 hysteresis Green (red) Green Red (green) Red Display au-return time Unit: s Move-protectlevel time Unit: s Settings displayed in reversed colors are initial settings. 13

Press Level Key + Mode Key for more than 1 s. Operation Level Press Level Key + Mode Key for more than preset time. Protect level Operation/adjustment lockouts Setting level lockouts / / / / Setting change lockout / Operation/Adjustment Lockouts Restricts key operations for operation level and adjustment level. Parameter Setting Operation level Moving adjustment level Process display Initial setting is 0. This cannot be displayed on models not equipped with the comparative output function. Setting Level Lockouts Restricts shifting initial setting level or advanced-function setting level. Setting Change Lockout Set display oapt 0 Allowed Allowed Allowed 1 Allowed Allowed Prohibited 2 Allowed Prohibited Prohibited Parameter Setting Shift initial setting level icpt 0 Allowed Allowed Restricts setting changes by key operation. When this lockout is set, it is no longer possible shift a setting change mode. However, all protect level parameters can still be changed. Shift advancedfunction setting level 1 Allowed Prohibited 2 Prohibited Prohibited Parameter Setting Setting change by key operation wtpt off Allowed on Prohibited Initial Settings Press the Level Key level. Select the input type. Power ON for 3 s min. move the initial setting If desired, shift the adjustment level set the temperature input shift. If required, shift the advanced-function setting level set the number of measurements for averaging, hysteresis s, au-zero time, display color change, display au-return time, or move--protect-level time. Press the Level Key operation level. Set the OUT s. for less than 1 s min. return the Measurement starts. 14

1 SV MAX/MIN LEVEL SHIFT UP Setting Example Initial Settings The settings for the following example are shown here. Example: Moniring the temperature of an industrial furnace Here, the temperature inside the furnace is be displayed in centigrade ( C). Temperature sensor: E52-PR Thermocouple, Measurement range: 0 1,400 C. 1. Set the input type the thermocouple R input range. Parameter: in-t (input type), Setting : 16 2. Select centigrade ( C) as the temperature unit. Parameter: d-u (temperature unit), Setting : c If you are using a comparative output model, make the setting as desired. Industrial furnace E52-PR Thermocouple Max Min Troubleshooting -C 100-240VAC When an error occurs, error details will be displayed on the main indicar. Confirm the error from the main indicar and take the appropriate countermeasures. Level display Main indicar Error contents Countermeasures Not lit e111 RAM memory error Repair is necessary. Consult your OMRON sales representative. 5 e111 EEPROM memory error When this error is displayed, press the Level Key for 3 seconds, and the settings will be resred the facry settings. If the error cannot be recovered, repair is necessary. Consult your OMRON sales representative. Not lit Flashes s.err Input error Confirm that the temperature sensor is correctly connected, and that there are no broken signal lines the temperature sensor. Input is out of the specified range (control range). Set the within the range immediately. If the condition does not return normal, repair is necessary. Consult your OMRON sales representative. Not lit Flashes 9999 The measurement after temperature input correction exceeds 9999. Not lit Flashes -1999 The measurement after temperature input correction is lower than 1999. The temperature input correction may be inappropriate. Use the adjustment level review the temperature input correction. The temperature input correction may be inappropriate. Use the adjustment level review the temperature input correction. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters in inches, multiply by 0.03937. To convert grams in ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject change without notice. 15

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, sred, installed and maintained and not subject contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not be construed as an amendment or addition the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it actual application requirements. Actual performance is subject the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned fix or establish key specifications for your application. Please consult with your Omron s representative at any time confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Aumation Company http://www.ia.omron.com/ 2017.8 In the interest of product improvement, specifications are subject change without notice. (c)copyright OMRON Corporation 2017 All Right Reserved.