Device/PLC Connection Manuals

Similar documents
Device/PLC Connection Manuals

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Configuration Nordex CC

Network Camera Operating Manual

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

XG-PH80W-N XG-PH80X-N SETUP MANUAL DATA PROJECTOR MODEL

LCD Projector XL30U / XL25U / SL25U

Controling the projector using a personal computer

DiD. LCD Video Monitor & Video Wall Universal User Manual. Digital Information Display

Controling the projector using a personal computer

DXI SAC Software: Configuring a CCTV Switcher. Table of Contents

FP2500-T41 User Manual

PREFACE. GP2000 Series VM Unit User Manual

Controlling the projector using a personal computer

USER MANUAL HDMI over IP EXTENDER

Modbus for SKF IMx and Analyst

The LP770 projector uses RXD, TXD and GND lines for RS-232C control. For RS-232C cable, a reverse type cable should be used.

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

DX100 OPTIONS INSTRUCTIONS

I N S T R U C T I O N D A T A

Projection Display. Serial Interface Specification

APPLICATION NOTE VACUUM FLUORESCENT DISPLAY MODULE

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Displacement sensor control unit UQ1 series. User s manual

Controlling the projector using a personal computer

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Content. 3G SDI 4X1 Switcher 1 INTRODUCTION. 1 2 SPECIFICATION PACKAGE CONTENT PANEL DESCRIPTION CONNECTION AND OPERATION..

WJ-GXE500 (NTSC) WJ-GXE500E (PAL)

Digital Ratio Controller

VGA AUDIO SWITCHER S MANUAL

MLA-XLR MIDI Line Amplifier

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

BUS UNITRONIC BUS CAN

PLEASE READ THIS PRODUCT MANUAL CAREFULLY BEFORE USING THIS PRODUCT.

Truck router (3Gbps/HD/SD/ASI)

EVENT INPUT/OUTPUT MODULE [PUME]

SignalTap Plus System Analyzer

This Errata Sheet contains corrections or changes made after the publication of this manual.

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

3-in 1- out DVI Switcher

PRELIMINARY. Orbis CU. Preliminary Data Sheet!

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708)

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

Design and Use of a DTV Monitoring System consisting of DVQ(M), DVMD/DVRM and DVRG

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

SY-HDBT-100 Extender Set

Fiber Optic Transmission Systems

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

EX-57A-O. User Manual. HDMI over IP (fiber) Uncompressed Multicast System. rev: Made in Taiwan

mini Wiring & Installation Instructions V06/05/08

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

FX2N-232IF RS232C INTERFACE BLOCK

System Troubleshooting for

Inverters Selection Guide

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

YAMAHA 03D SERIAL AUDIO MIXER

SY-HDBT-SLIM-100S Extender Set

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Siemens Industry Online Support

MULTIMEDIA PROJECTOR MODEL XG-PH70X XG-PH70X-N SETUP MANUAL

Globalmediapro SMR-650

HVWIP-Series (HVWIP-T + HVWIP-R)

LED-DEC W07 REMOTE DISPLAY WIRELESS DECODER

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 Operating Instruction

Single sensor setup with NIVEL210

PATTERN GENERATOR PG-3D1X USER MANUAL V.2012PG-3D1X101.00

Datasheet NVISION Compact Space and Cost Efficient Utility Routers

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

Model 1476-C SuperQuad HR

AtlonA 4x4 HDMI over CAT5 Matrix Switcher with IR Control AT-HD44M-SR. User Manual

MPEG4 Digital Recording System THE VXM4 RANGE FROM A NAME YOU CAN RELY ON

LAUREL ELECTRONICS, INC.

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

H.264. Mobile DVR 4CH

and HDCP 2.2 supported Digital Multi Switcher MSD-802UHD Specification (Preliminary)

Digital Video Wall Control Box

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

Installation Guide. HDMI 4x1 Switcher

AVK-901 DVI/VGA with Audio Extender over IP for Digital Signage

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

Programmable Video Signal Generator VG-880. Instruction Manual. Ver 1.10

1x12 VGA & Audio over CAT5 Splitter

Bel 2120B. Analogue/AES/SDI Shuffler. User s Guide Version /05/04

User Manual RTHDBT402PT & RTHDBT402PR

USER S MANUAL (1/2) (Functions and connections)

CSA x2 Alarming RS-232 Seq. Video Switcher. Instruction Manual

VIS-PSC9 Professional Scaler Switcher

MS2540 Current Loop Receiver with RS485 Communication

Extra long-range RFID (proximity) card reader

Rack mounted telephone- and leased line modem for industrial applications

HITACHI. VisionCube. Service Manual

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

Installation instructions for Brookhouse NMEA multiplexer model AISC

Transcription:

Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection manual" information. Also, be sure to download the "Preface for Trademark Rights, List of Units Supported, How to Read Manuals and Documentation Conventions" PDF file. Furthermore, be sure to keep all manual-related data in a safe, easy-to-find location.

Fuji Electric Corporation s 1 System Structure The following describes the system configuration used when connecting the Fuji Electric inverters to the GP/GLC/LT. If a communication error occurs while the unit is operating via RS-485, a stop command may not be recognized via RS-485. To prevent any accidents, be sure to use the inverter external signal terminal s forced stop function so that emergency stop will always be effective. If an alarm is reset with a run command sent via RS- 485, the unit will suddenly restart. To prevent accidents, be sure to confirm that the run command is no longer being sent. FRENICS5000G11S Series *1 Cable Diagram GP/GLC/LT FRN G11S-2 FRN G11S-4 FRENICS5000P11S Series RS-485 (1:1) (Cable Diagram 1) RS-485(1:n) (Cable Diagram 2) GP Series GLC Series LT Type C *1 Cable Diagram GP/GLC/LT FRN P11S-2 FRN P11S-4 RS-485 (1:1) (Cable Diagram 1) RS-485(1:n) (Cable Diagram 2) GP Series GLC Series LT Type C *1 The characters in the inverter model codes reflect applicable standard generator capacities. *2 The character in the option card model code reflects the classification of the card type (either A, B, or C) according to this series inverter capacities. GP-PRO/PBIII for Windows Device/PLC Connection Manual 1

FVR-E11S Series *1 Cable Diagram GP/GLC/LT FVR E11S-2 FVR E11S-7 RS-485 (1:1) (Cable Diagram 3) RS-485(1:n) (Cable Diagram 4) GP Series GLC Series LT Type C FVR-C11S Series (Optional for Communication) *1 Communication I/F Cable Diagram GP/GLC/LT FVR C11S-2 FVR C11S-6 FVR C11S-7 Option: RS-485 (1:1) OPC-C11S-RS *2 (Cable Diagram 1) RS-485(1:n) (Cable Diagram 2) GP Series GLC Series LT Type C *1 The characters in the inverter model codes reflect applicable standard generator capacities. *2 The character in the option card model code reflects the classification of the card type (either A, B, or C) according to this series inverter capacities. 2 GP-PRO/PBIII for Windows Device/PLC Connection Manual

2 Cable Diagrams The following cables are recommended: <For G11S, P11S, C11S> Furukawa Electric UL AWM2789 1/0.65 mm 2 long distance braided shield cable < For E11S> Cable conforming to EIA568 standard (for 10BASE-T), as well as RJ45 connector The maximum length of a cable (transmission distance) is 500m. Depending on the usage environment, a unit may malfunction due to the noise generated from the inverter. In such a case, connect a ferrite core or condenser to the cable. GP or GLC or LT RDA RDB FG Attach to straight cable, or to looped section of cable (loop 2 to 3 times). DX(+) DX(-) SD Ferrite core Condenser G A terminating resistor (100Ω ) has been embedded in the E11S. When connecting the inverter to the end of the cable, turn ON SW2 located below the connector. Cable Diagram 1 (1:1) <When using Digital's RS-422 connector terminal adapter > 1:1 RS-422, 2 wires RDA RDB SDA TERM FG terminal block DX(+) DX(-) SD GP-PRO/PBIII for Windows Device/PLC Connection Manual 3

GP GP230-IS11-0 <When using Digital s RS-422 connector terminal adapter > RDA DX(+) RDB DX(-) SDA FG SD terminal block <When making your own cable> 7 9 TRMX terminal block 10 RDA DX(+) 16 RDB DX(-) 11 SDA SD 15 18 CSB 19 ERB 21 CSA 22 ERA 1 FG Cable Diagram 2 (1:n) <When using Digital s RS-422 connector terminal adapter > 1:n RS-422, 2 wires 1 2 n RDA DX(+) DX(+) DX(+) RDB DX(-) DX(-) DX(-) SDA SD SD SD TERM FG <When making your own cable> GP GP230-IS11-0 1 2 n RDA DX(+) DX(+) DX(+) RDB DX(-) DX(-) DX(-) SDA SD SD FG SD 4 GP-PRO/PBIII for Windows Device/PLC Connection Manual

<When making your own cable> 1 2 n 7 9 TRMX DX(+) DX(+) DX(+) 10 RDA DX(-) DX(-) DX(-) 16 RDB SD SD SD 11 SDA 15 18 CSB 19 ERB 21 CSA 22 ERA 1 FG Cable Diagram 3 (1:1) <When using Digital s RS-422 connector terminal adapter > 1:1 RS-422, 2 wires RDA RDB SDA TERM FG <When making your own cable> RJ45 connector 4DX(+) 3DX(-) 7 9 TRMX RJ45 connector 10 RDA 4DX(+) 16 RDB 3DX(-) 11 SDA 15 18 CSB 19 ERB 21 CSA 22 ERA 1 FG GP-PRO/PBIII for Windows Device/PLC Connection Manual 5

Cable Diagram 4 (1:n) <When using Digital s RS-422 connector terminal adapter > 1:n RS-422, 2 wires 1 2 n RDA 4DX(+) 4DX(+) 4DX(+) RDB 3DX(-) 3DX(-) 3DX(-) SDA TERM FG <When making your own cable> 7 9 TRMX 1 4DX(+) 2 4DX(+) n 4DX(+) 10 RDA 3DX(-) 3DX(-) 3DX(-) 16 RDB 11 SDA 15 18 CSB 19 ERB 21 CSA 22 ERA 1 FG 6 GP-PRO/PBIII for Windows Device/PLC Connection Manual

3 Supported Devices FRENICS5000G11S/FRENICS5000P11S Series Device Bit Addresses Word Addresses Remarks Basic function F0000 ~ F4215 F00 ~ F42 Terminal function E0100 ~ E4715 E01 ~ E47 Controlling function C0100 ~ C3315 C01 ~ C33 Motor 1 P0100 ~ P0915 P01 ~ P09 High level function H0300 ~ H3915 H03 ~ H39 Motor 2 A0100 ~ A1815 A01 ~ A18 Option o0000 ~ o2915 o00 ~ o29 Command data S0100 ~ S1115 S01 ~ S11 Monitor data M0100 ~ M4815 M01 ~ M48 *1 Alarm reset m00 *2 L/H *1 Data write cannot be performed. *2 m00 is a virtual device and is used to reset the history of alarms occurred on the inverter. Writing any data to m00 will reset the alarm. However, data read cannot be performed. FVR-E11S Series Device Bit Addresses Word Addresses Remarks Basic function F0000 ~ F4215 F00 ~ F42 Terminal function E0100 ~ E4215 E01 ~ E42 Controlling function C0100 ~ C3315 C01 ~ C33 Motor 1 P0100 ~ P1015 P01 ~ P10 High level function H0100 ~ H4615 H01 ~ H46 Motor 2 A0100 ~ A1915 A01 ~ A19 Command data S0100 ~ S1115 S01 ~ S11 Monitor data M0100 ~ M4815 M01 ~ M48 *1 Alarm reset m00 *2 L/H *1 Data write cannot be performed. *2 m00 is a virtual device and is used to reset the history of alarms occurred on the inverter. Writing any data to m00 will reset the alarm. However, data read cannot be performed. GP-PRO/PBIII for Windows Device/PLC Connection Manual 7

FRENICS5000G11S/FRENICS5000P11S Series Device Bit Addresses Word Addresses Remarks Basic function F0000 ~ F3615 F00 ~ F36 Terminal function E0100 ~ E0315 E01 ~ E03 Controlling function C0100 ~ C0715 C01 ~ C07 Motor 1 P0000 ~ P0015 P00 High level function H0100 ~ H2515 H01 ~ H25 Option O0000 ~ O1115 o00 ~ o11 *1 Command data S05 ~ S06 S05 ~ S06 Monitor data M0100 ~ M4815 M01 ~ M48 *1 Alarm reset m00 *2 L/H *1 Data write cannot be performed. *2 m00 is a virtual device and is used to reset the history of alarms occurred on the inverter. Writing any data to m00 will reset the alarm. However, data read cannot be performed.! Caution The system area (20 words) cannot be used. Also, on the GP/GLC/LT offline screens and the screen editor software s system area selection screen, the protocol display and operation will be the same as that which appears when the system area can be used. Even if the system area is selected on these screens, however, it will automatically be designated as not selected. Depending on the inverter series, supported functions and ranges will vary. For more detailed information, refer to each inverter series operation manual. On GP-PRO/PB III, enter the device address and station address as follows: Address (decimal number) (Decimal bit position number) Device name Station address (decimal number) 8 GP-PRO/PBIII for Windows Device/PLC Connection Manual

4 Environment Setup FRENICS5000G11S/FRENICS5000P11S Series GP/GLC/LT Settings Settings Setting Function Baud Rate 9600bps Baud rate 9600bps H34 Data Length 8bit Data Length 8bit H35 Stop Bit 2bit Stop Bit 2bit H37 Parity Bit None Parity Bit None H36 Data Flow Control ER Communication Format 2-wire type Station Address 1 ~ 31 Station Address 1 ~ 31 H31 FVR-E11S Series GP/GLC/LT Settings Settings Setting Function Baud Rate 9600bps Baud rate 9600bps H34 Data Length 8bit Data Length 8bit H35 Stop Bit 1bit Stop Bit 1bit H37 Parity Bit None Parity Bit None H36 Data Flow Control ER Communication Format 2-wire type Unit No. 1 ~ 31 Station Address 1 ~ 31 H31 FVR-C11S Series GP/GLC/LT Settings Settings Setting Function Baud Rate 9600bps Baud rate 9600bps o04 Data Length 8bit Data Length 8bit o05 Stop Bit 2bit Stop Bit 2bit o07 Parity Bit None Parity Bit None o06 Data Flow Control ER Communication Format 2-wire type Unit No. 1 ~ 31 Station Address 1 ~ 31 o01 Optional selection 1 o00! Caution The FVR-C11S Series requires a communication card (Model: OPC-C11S-RS*). Be sure to set o00 to 1 to enable the RS-485 communication option. GP-PRO/PBIII for Windows Device/PLC Connection Manual 9

5 Error Codes <Error Codes Specific to s> The error codes specific to the inverters will appear on the GP screen s left bottom, as Host Communication Error (02:**:##). (The ** characters indicate an error code specific to the inverter, and the ## characters indicate the station address of the inverter on which an error occurred.) Error Codes Error Code Error Name Description 4AH Format error Data transmission request statement characters are incorrect. The last character of the request statement is not in the correct position. 4BH Command error A non-existent command has been sent. 4CH Link priority error It was attempted to write command or operation command data, with the link option installed. (When the link option has been installed, the command and operation command data cannot be written via RS-485.) 4DH It was attempted to write new function data No write authorization during data write from the link option. 4EH Function code error A non-existent function code has been requested. 4FH Write inhibit error It was attempted to write an operation inhibit function or write inhibit during run function while the unit was operating. 50H Data error Data that has been written was exceeded an effective range. 51H Write error It was attempted to write new function data during writing another function. Note: The latest communication error code has been stored in M26. Alarms occurred on the inverter will have either code numbers M16, M17, M18, or M19. M16: Latest alarm M17: Previous alarm M18: Alarm before the previous alarm M19: Alarm before the two old alarms For more detailed information, refer to your inverter s operation manual. 10 GP-PRO/PBIII for Windows Device/PLC Connection Manual