MODEL7304 V.35 Optic Fiber Modem User Manual Shenzhen 3onedata Technology Co.,Ltd

Similar documents
Computer - Digital Output - Modem - Analog - RJ 11 Output Jack

MultiMode FOMs -ST and -SMA

High Speed Async to Sync Interface Converter

Miniature Synchronous/Asynchronous Fiber Optic Modems

Single mode 9/125µm, duplex

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

OPERATION MANUAL INSTALLATION AND KML.F. Fiber Optic Interface Main Link. Kilomux Module. The Access Company

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Async/Sync Fiber Optic Multiplexor

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Perle Fast Ethernet Media Converters

PHOX TM. Camera Link Fiber Extender. Base Configuration KEY FEATURE APPLICATIONS PHOX-BM PHOX-BL-10/20/40/50

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

RS-232 to Multi-Mode Fiber Optic Media Converter

Features. CPU Version. Non-CPU Version

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Synchronous Fiber Optic Modem

USER MANUAL MODEL 2701/B, C, D. G.703/G.704 NTU with EIA-530, V.35, X.21 Interfaces SALES OFFICE (301) TECHNICAL SUPPORT (301)

Perle Fast Ethernet Media Converters

DVI KVM Extender DVIVision 7.6

MultiView 450. Installation & Reference Guide. Preliminary. Magenta Research Ltd

VIDEO ALARM VERIFICATION UNIT VIVER

DVI KVM Extender DVIVision 7.4

DXI SAC Software: Configuring a CCTV Switcher. Table of Contents

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Analog HD video over fiber converters for smart HD CCTV

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual


F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

MediaCento IPX 4K. Product Data Sheet VX-HDMI-4KIP-TX VX-HDMI-4KIP-RX. Overview. Basic Features blackbox.com

PHOX TM. Camera Link Fiber Extender. Dual Base Configuration KEY FEATURES APPLICATIONS PHOX-B2M-250 PHOX-B2L-10/20/40/50

I N S T R U C T I O N D A T A

ASP-FIBRS1 User Manual

Industrial 4 Port RS232/422/485 to Dual Ethernet Serial Device Server - PoE PD

E3/DS3 Fibre Extender

ACTIVE IF SPLITTER/COMBINER UHP-IFS

SY-HDBT-100 Extender Set

TC3005(LED/ELED/LASER) User's Manual

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. June 2015 Part Numbers FIBER DRIVER

DVI KVM Extender DVIVision 7.2

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

RCV VOICE/DATA CSU VOICE/DATA CSU XMT BUSY. BUSY TxD RxD RTS CTS POWER LOOPBACK SIG SYNC USER'S MANUAL

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

CH-526RX HDMI Splitter with Audio over CAT5e/6/7 Receiver

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

PRO-SDI44/84/124/164. 4x4/8x4/12x4/16x4 3G-SDI Matrix Switchers OPERATION MANUAL

Job Aid Server and CSS Separation Avaya S8700 Media Server

CH-2538TXWPKD 4K UHD HDMI/VGA over HDBaseT Wallplate Transmitter. CH-2527RX 4K UHD HDMI over HDBaseT Receiver. Operation Manual

Model CMX3838A2 AV Matrix Switch with DSP audio (firmware 1.0)

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

User s Manual. Component video to 1-fiber DVI converter, CNDF-200. Manual Contents.

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

3G fiber. TL7075/76 Optical 3Gbit/s Link solution with full duplex Communication Channel. TL Features. TL Features

SY-HDBT-SLIM-100S Extender Set

Model Colorado Ultra Wide Bandwidth HDTV Matrix Switch

CH-507TX & RX HDMI to CAT5e/6 with LAN/IR/RS-232

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Installation Manual. Fiber Optic Transmission Systems. 19inch 1U Rack version

Quick Operation Guide of LTN7700/7600 Series NVR

CH-507TX & RX HDMI over CAT5e/6/7 Transmitter and Receiver

CH-1605RXV 4K UHD+ HDMI over HDBaseT 2.0 Receiver (PD) with HDR/ARC

Chapter Status. Contents. Chapter 5. Overview STATUS

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

CMLUX-4H4CAT. 4 by 4 HDMI V1.3 over CAT 6 Matrix with IR Return Control. Operation Manual CMLUX-4H4CAT

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

TC1630. T1/E1 FIBER OPTIC MODEM User's Manual

CDVI-1109TXC & RXC DVI over CAT5e/6/7 with LAN/PoC/IR Extender

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

Fiber Optic Transmission Systems

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

3G-SDI 4 by 4 Switcher

3GSDI Audio Embedder

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

CH-507TX & RX HDMI to CAT5e/6 with LAN/IR/RS-232

Video Digital Optical Converter

TRUCOLOUR. 4x4 Video Matrix with HDBaseT Outputs INSTALLATION GUIDE

CMSDI G-SDI Matrix

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

Instruction Manual RT-91600D-SL RR-91600D-SL Sixteen Channel Video Multiplexer With Remote Diagnostic Interface

Configuration Vestas VMP3500

Hardware Specifications

RS-232 to Fiber Optic Multiplexor

CH-507TXBD & RXBD HDMI to CAT5e/6 with LAN/IR/RS-232/ Bidirectional PoE DRAFT. Operation Manual

Rack mounted telephone- and leased line modem for industrial applications

Functional Diagram: Figure 1 PCIe4-SIO8BX-SYNC Block Diagram. Chan 1-4. Multi-protocol Transceiver. 32kb. Receiver FIFO. 32kb.

HDMI over Optical Fibre Transmitter & Receiver Kit # 15354

CWHDI-TX2 & RX2 Wireless Multi-Format input Transmitter to HDMI Receiver Box

Transcription:

MODEL7304 V.35 Optic Fiber Modem User Manual Shenzhen 3onedata Technology Co.,Ltd Tel: +86-755-26702688 Fax: +86-755-26703485 www.3onedata.com

Contents 1. Introduction...3 2. Product Features...3 3. Specifications... 3 4. Description on Installation and Panels...4 4.1 Unpacking:...4 4.2 Front/Rear panels of the stand alone device:...4 4.3 Front/Rear panels of Rack-mountable casing:...6 5. MODEL7304 Application... 7 5.1 Definition of signal lines at V.35 interface...7 5.1.1 Distribution diagram of guiding feet on M34 cored jack...7 5.1.2 Definition of signal lines at V.35 interface...7 5.2 Standard V.35 crossover cable connection diagram...8 5.3 Sittings of switch and jumper...8 5.3.1 Clock setting...8 5.3.2 Phase selection...9 5.3.3 Settings of loopback test and pseudo-random code test... 9 5.3.4 Framing/non-framing and time slot settings... 10 6. Common Problems... 11 Page 2 of 11

1. Introduction MODEL7304 is a high-performance V.35 optic fiber modem developed by using a dedicated integrated circuit. It is to modulate a N 64K V.35 data signal directly over single- or multi-mode optic fiber for a transmission via optic cable line. At another end of the optic cable, optical signal is demodulated into a V.35 data signal. V.35 interface may be directly connected with the V.35 interfaces of image and data terminals or the WAN ports of MUX, exchanger and router for a dedicated network setup or a LAN connection. 2. Product Features Rate N 64Kbit/s (N=1~32) Support the loopback of local analog/digital interface Support remote loopback function Support pseudo-random code test function 120km trunking -free transmission distance for single-mode optic fiber Capable to be communicated with FE1 Fiber Modem Available with complete line detection and alarm indications Available with independent structure and 19-inch Rack-mountable structure Rack-mountable structure can be inserted with 16 modules AC 220V and DC 48V inputs may be selected for fiber optic modems of both structure For Rack-mountable fiber optic modems, dual power supply heat backup is provided to ensure a high operating reliability 3. Specifications Optic interface: Line mode type: CMI Line mode rate: 2.048Mbps Operating wavelength:850nm,1310nm or 1550nm Optic fiber connector: SC/PC Applicable optic fiber: multi-mode, single-mode Transmission distance: Single-mode: up to 120km Multi-mode: up to 2km V.35 interface: Data rate: N 64Kbps (N=1~32) Available with CTS/RTS (Hardware) flow control function Type of connector: M34 connector Operating mode: DCE Indicator lamps: To indicate the operating status of power supply, data receiving/sending, loopback and random code test, code missing alarm, out-of-frame alarm etc. Structure: Independent: 140mm(depth) x 210mm(width) x 42mm(height) Page 3 of 11

Rack-mountable: 19in 4.5U standard casing Power supply: Independent:85V~264V AC input, 5V/2A output -36V~-72V DC input, 5V/2A output Rack-mountable:150V~260V AC input,5v/16a,12v/1a output -38V~-58V DC input,5v/16a,12v/1a output Power consumption: 3W Operating temperature: 0 C~50 C Storage temperature: -20 C~80 C Humidity: 5%~90% (free of condensate) 4. Description on Installation and Panels MODEL7304 User Manual 4.1 Unpacking: After the equipment is unpacked, a check shall be done for the completeness. If any part is found missing, please immediately contact our representative offices or agents. Complete packing shall include the following items (for an independent product): One set of V.35 Fiber Modem MODEL7304 One V.35 Fiber Modem Operation Manual One power line(v.35 Fiber Modem/AC) Please also contact our representative offices or agents for any transportation damage found with this product. 4.2 Front/Rear panels of the stand alone device: Front panel: Front Panel of MODEL7304 POWER:Power supply indicator lamp. Constantly lightening after the machine is turned on. RXD: Data receiving indictor lamp at V.35 interface. Flash indicates that there is data output from V3.5 interface. The quicker it flashes, the higher rate of data output from V3.5interface. TXD:Data sending indictor lamp at V.35 interface. Flash indicates that there is data input to V3.5 interface. The quicker it flashes, the higher rate of data input to V3.5interface LOF : E1 Alarm indicator lamp of input signal out-of-frame in optic line. Constantly lightening indicates the alarm with local device; flash indicates the alarm with opposite device. Alarm status of opposite device can be detected only at framing mode. LOS:E1 Alarm indicator lamp for code missing in optic line. Constantly lightening indicates the alarm with local device. Flash indicates the alarm with opposite device. LOOP:Indicator lamp of loopback test status. When local device is at a loopback status, the Page 4 of 11

lamp flashes. When local device is not at a framing mode, it is unable to detect whether opposite device is at a loopback test status. PTOK:Indicator lamp of pseudo-random code test. When the device is at a loopback status, pseudo-random code test can be made. If this lamp is constantly lightening, it indicates that pseudo-random code passes the test. Rear panel: Rear Panel of MODEL7304/AC 220V AC: AC power jack. OFF ON: Power switch. When the ON button is pressed down, the power supply is turned on. V.35: V.35 interface, with a M34 cored jack. TX RX : Receiving/sending jack of optical fiber, with TX as the sending terminal and RX as the receiving terminal. There is a coded switch S5 on the panel, which is used as the system configuration switch to set such functions as clock, time slot, phase, loopback and pseudo-random code test etc. Wherein, S5.1 and S5.2 are clock settings. S5.1=OFF, S5.2=OFF:network clock at V.35 interface(received Recovered). S5.1 = OFF,S5.2=ON:network clock at the optic fiber interface (Received Recovered). Remote time slot setting can be tracked only at this status. S5.1=ON, S5.2=OFF: invalid S5.1 = ON,S5.2=ON:using local crystal OSC generating clock S5.3: time slot setting S5.3=OFF,using remote time slot setting (valid only when S5.1 = OFF,S5.2=ON) S5.3=ON,using local time slot setting S5.4: for V.35 receiving clock phase selection S5.4=OFF, using positive phase S5.4=ON, using negative phase S5.5: Local loopback setting (optic interface in direct loopback), ON valid. S5.6: Local digital loopback (V.35 interface loopback), ON valid. S5.7: Remote digital loopback (V.35 interface loopback), ON valid. Valid at framing mode (0 time slot unused). S5.8: Pseudo-random code test, ON valid, and valid at loopback status. MODEL7304 bottom coded switch: Bottom Coded Switch After time slot 0 is valid, other coded switches in whatever positions are all valid. Page 5 of 11

Select the number of time slots according to the expected rate. Normally for an independent type, a time slot setting of automatic tracking Central Site module is selected. Coded switches of plate-clip time slot correspond to S1, S2, S3 and S4. Rear Panel of MODEL7304/DC 48V DC: DC -48V power supply connector The others are the same as AC Rear Panel 4.3 Front/Rear panels of Rack-mountable casing: RACK front panel: Front Panel of RACK +5V: 5V main power supply indicator lamp +12V: 12V fan power supply indicator lamp Under the panel is a group of indicator lamps matrix: PWR : power supply lamp RXD : lightening upon data receiving at V.35 TXD : lightening upon data sending from V.35 LOS : lightening when the optic line gets lost LOF : lightening after a synchronization of data out-of-frame TEST : lightening during loopback test (equivalent to LOOP) PTOK: lightening after a successful pseudo-random code test RACK/AC AC redundancy power supply panel: RACK/AC AC Redundancy Power Supply Panel 160~270 VAC:AC 220V input jack ON OFF:power switch +5V:5V main power supply indicator lamp; +12V:12V fan power supply indicator lamp Page 6 of 11

RACK/DC DC redundancy power supply panel: RACK/DC DC Redundancy Power Supply Panel 40~60 VDC:DC-48V input connector (FG grounded, with - + terminals connected with 48V input) ON OFF: power switch +5V: 5V main power supply indicator lamp +12V: 12V fan power supply indicator lamp 5. MODEL7304 Application 5.1 Definition of signal lines at V.35 interface 5.1.1 Distribution diagram of guiding feet on M34 cored jack Distribution diagram of guiding feet on M34 cored jack 5.1.2 Definition of signal lines at V.35 interface As shown:(operating mode:dce) Definition of Signal Lines at V.35 Interface V.35 Feet Signal Function Direction A CGND Frame ground B GND signal ground C RTS request to send input D CTS consent to send output E DSR data set ready output F DCD data carrier detection output H DTR data terminal ready input P TXD A transmitting data line A input S TXD B transmitting data line B input R RXD A receiving data line A output Page 7 of 11

T RXD B receiving data line B output U EXTCLK A exterior clock line A input W EXTCLK B exterior clock line B input V RXCL A receiving clock line A output X RXCL B receiving clock line B output Y TXCL A transmitting clock line A output AA TXCL B transmitting clock line B output MODEL7304 User Manual 5.2 Standard V.35 crossover cable connection diagram V.35 feet V.35 feet CGND A A CGND GND B B GND RTS C D CTS CTS D C RTS DSR E H DTR DTR H E DSR TXDA P R RXDA TXDB S T RXDB RXDA R P TXDA RXDB T S TXDB EXCA U V RXCA EXCB W X RXCB RXCA V U EXCA RXCB X W EXCB 5.3 Sittings of switch and jumper Independent device has totally 5 setting switches, with S5 located on the rear panel and S1~S4 under the bottom cover. The user can easily make settings without the need to open the cover. 5.3.1 Clock setting V.35 interface timing (S5.1= OFF, S5.2=OFF): the sending timing is V.35 port timing, and the received data, after buffering, is synchronized with V.35 port timing. Optic interface receiving timing (optic interface originated from the clock, S5.1=OFF, S5.2=ON): the sending timing is optic interface receiving timing, and the received data, after buffering, is synchronized with optic interface receiving timing. Under this timing mode, local time slot setting can automatically track the opposite time slot setting. Page 8 of 11

Local main timing (S5.1=ON, S5.2=ON): the sending timing is of local crystal OSC, and the received data, after buffering, is synchronized with local timing. 5.3.2 Phase selection S5.4 is used for the receiving phase selection of V.35 interface. 5.3.3 Settings of loopback test and pseudo-random code test S5.5~S5.8 of coded switch S5 are used for setting the loopback test and pseudo-random code test. S5.5 is local loopback control (LLOOP) and optic interface is directly looped back to V.35 interface. OFF indicates normal operation; ON indicates local loopback test. The default is OFF. It is used for testing whether local device is in normal operation. V.35 Fiber Modem V35 Optical Interface Local Loopback Schematic S5.6: local digital loopback control (DLOOP). OFF indicates normal operation; ON indicates local digital loopback. The default is OFF. With a loopback from local V.35 interface to E1 optic interface, it is used for testing whether the remote device and E1 optic line are in normal operation. V.35 Fiber Modem V35 Optical Interface Local Digital Loopback S5.7: OFF indicates normal operation ; ON indicates command remote loopback. The default is OFF. As this command must be sent through E1 optic line to remote end for validness, it will become invalid at the following two cases: 1 the remote end is not V.35 Fiber Modem device; 2 V.35 Fiber Modem is working at a non-framing status, at this moment all time slots of E1 are used for transmitting the data from V.35 interface at a rate of 2048Kbps. Through a transmission of loopback command from local device to remote device, the command remote loopback is achieved. V.35 Fiber Modem V35 Fiber Link Fiber Modem V35 V.35 Local Remote Remote Loopback S5.8: Pseudo-random code test control (PATT). OFF indicates normal operation; ON indicates pseudo-random sequence test. The default is OFF. It generates a pseudo-random sequence code to be transmitted to V.35 optic line output terminal and tests whether V.35 optic line input signal is in compliance with this sequence standard, so as to judge whether the device and line transmission have an error code. Page 9 of 11

V.35 Fiber Modem V35 Fiber Link Fiber Modem V35 V.35 Local Remote pseudo-random Code Test Remark: Pseudo-random sequence code test can be made only under a loopback status. At this moment, constantly lightening of LOOP and PTOK/CRC lamps shows local status, flash shows remote status; TXD and RXD lamps are used for showing the status of local TXD or RXD. 5.3.4 Framing/non-framing and time slot settings Totally 32 coded switches S1, S2, S3 and S4 are used for E1 time slot setting. E1 Time Slot Setting 1 st switch (S1.1) is used for controlling E1 framing/non-framing. ON refers to non-framing mode. 31 switches, from 2 nd 32 nd (S1.2~S1.8, S2, S3, S4), are respectively used for controlling the selection of 1 st 31 st time slots. Set at ON, the corresponding time slot is selected; set at OFF, the corresponding time slot is not selected. The rate of V.35 interface is completely dependent on the number of the selected time slots. For example: the setting of 3 rd switch to ON and all other switches to OFF indicates that 2 nd time slot is selected, at this moment the rate is 64K; the setting of 7 th and 8 th switches to ON and all other switches to OFF indicates that 6 th and 7 th time slots are selected, with a rate of 2 64K=128K. TS0 setting is used for specifying E1 frame to be transparent or framing: 0 --framing, 1 --non-framing. But the bit has to be specified in combination with other time slots. TS16 setting is used for controlling E1 frame structure to be PCM30(CAS) or PCM31(CCS): 0 PCM30, at this moment 16 th time slot must not be used for transmission service; 1 PCM31, 16 th time slot can be used for transmission service. Besides, TS1 TS31 are respectively used for controlling the selection of 1 st 31 st time slots: 1 the corresponding time slot is selected; 0 the corresponding time slot is not selected. Typical application: Non-framing mode: 1 st switch is set to ON, and all other switches to OFF (other switches are located in such a way that the setting of non-framing is unaffected) Framing mode: 1st switch is set to OFF, and all other switches are set according to the time slot positions to be used by E1 channel and the rate of V.35 port. (If it is set to tracking remote time slot, the time slot switch will become invalid) Attention: Ex-works S1, S2, S3 and S4 are all set to OFF Attention: The setting of tracking remote time slot; S5.2 to ON ; S5.1 and S5.3 to OFF Page 10 of 11

6. Common Problems Common Failures and Solutions No. Failure Cause Solution 1 PWR power supply 1.Power supply not properly 1.Check power switch and jack indicator lamp not connected 2.Replace protector tube 3.Correct -48V lightening 2.Protector tube damaged power supply line connection 3. -48V DC input tie-line in 4.Returned to the manufacturer for reverse connection 4.Internal power supply circuit with failure repair. 2 LOF out-of-frame 1.Optic interface not clean 1. Clean the connector of optic interface alarm lamp lightening 2.Optic fiber not well inserted 3.Wrong clock setting 4.Time slots of the devices at two ends not conformance 5.Internal circuit damaged 2. Insert the SC connector in place 3. Refer to the description on rear panel 4. Returned to the manufacturer for repair. 3 LOS data loss alarm 1. Optic fiber in wrong 1. Correct the connection lamp lightening interconnection 2.Optic fiber not well inserted 3.Optic fiber broken 4.Internal circuit damaged 2. Insert the SC connector in place 3. Check optic cable 4. Returned to the manufacturer for repair. 4 TXD lamp not V.35 interface not well 1. Check the connecting line and lightening connected or the router etc. not turned on. terminal device Page 11 of 11