DMX Relais/Analog Interface 4. User Manual

Similar documents
DMX-Universaldemux. 8 outputs with different operation modes Treshold / Binary / PWM / Strobe / Servo. User Manual

DMX-LED-DIMMER X9 HR 9x 16 BIT PWM per 10A

DMX-LED-DIMMER X9 HR 9x 16 BIT PWM per 10A

DMX-LED-DIMMER S. User Manual

DMX-Splitter 4. User Manual

ArtNet-LED-Dimmer 6 ArtNet-LED-Dimmer 6R

LIGHT REMOTE. for Android

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

Operating Instructions

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

OPERATING MANUAL. DMX LED Current Dimmer 5004A-EP Mk2

Q516 HIGH RES AUDIO DELAY ORDERING OPTIONS SUPPORT OPTIONS MANAGEMENT AND CONTROL HIGH PRECISION AUDIO DELAY FOR MICRO SECOND ACCURACY

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

-Technical Specifications-

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

ILDA Switch Automatic switching board for ILDA signals

DA8-T DA8-T MANUAL

VS-201H VS-401H VS-801H

LF101XF Six Function DCC Function Only Decoder Art. No February 2007

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

TM Load-regulated locomotive decoder

Installation and Operation Manual. for the. SM-6 Programmable Stereo Mixer

KACO-display. Wireless Solar Monitoring System. Operating Instructions KACO-display. full of energy...

HP6E Operating Manual. August 2012

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

User Manual. Model 979T and 979R Digital Audio Converters

DCP100 Digital Control Programmer Specifications

QDA4-44 RF Amp/Combiner

D10C SERIAL DIGITAL TO ANALOG CONVERTER USER MANUAL

LED-Panel C Product Sheet

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

HD Digital MPEG2 Encoder / QAM Modulator

Luminaire SIGNATURE SERIES

The Art of Engineering

HDMI 1X4 Distribution Amplifier (Splitter)

LIGHT AIR SWITCH. User Manual and Troubleshooting Guide WIRELESS LIGHTING MODULE ACKNOWLEDGEMENTS SAFETY WARNINGS EQUIPMENT DESCRIPTION

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Installation and Operation Manual. for the. IPC-2, Twin stereo level matching interface


Instructions to Authors

SUPPLEMENTARY INFORMATION

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

Meteor Product Catalogue

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

Capacitance Limit Detection nivotester FTC 420/421/422

FRQM-2 Frequency Counter & RF Multimeter

FD400Multi Function Decoder. User Manual. 04/2013

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

STEREO OR MONO CONTINUITY TM POWER AMP

Modular DAA with 2/4 Wire Convertor. XE0002D Block Diagram

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

Light Curtain Type LA

HP Presentation Scanner. Quick Reference Guide

Operating Instructions

Maintenance/ Discontinued

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

istep STEPPER MOTOR PUMP

Registers type ILR7XX and ILR7XXT

RENFE TAF / CP FOGUETE References: & 47023

STC-33 Product Specification VGA Progressive Scan Machine Vision Board Camera

LED-Strip C12 MK2.6. Product Sheet

Turnout Decoder TD Maxi. User Manual - version 0.1.6

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Werkstattinformation Informations d atelier Informazioni di officina Workshop-information Información de taller

Level 2 Digital Electronics 2 ( )

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

MICROMASTER Encoder Module

LED-Strip C25 MK2.6. Product Sheet

Shutter BladeFader. Functional description Shutter BlackFader V1.0

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

R&S ZN-Z154 Calibration Unit Specifications

SM-10 SAT Level Meter User s Manual

KHT 1000C HV-Probe Calibrator. Instruction Manual

Dot XL-3 CW/WW is an extra bright dot with 3 high performance LEDs

User Guide. Centrex Recording Interface

Operating instructions Electronic preset counter Type series 717

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

C200H-AD002/DA002 Analog I/O Units Operation Guide

2X2 Panel. 1X2 Panel

MARCO CORNER, 19/ THIENE (VI) ITALIA

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

ACTIVE IF SPLITTER/COMBINER UHP-IFS

Instructions to Authors

TVAC20000 User manual

istep STEPPER MOTOR PUMP

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

1 Channel VGA Over Fiber Transmitter and Receiver Extender. User Manual L-1VGA-FE

SCALE & WEIGHT DISPLAYS

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Dot XL-3 RGB. 3 High intensity Nichia SMT LEDs per dot Million additive RGB colors bit (Gamma correction)

STC-TC152USB-AT/AS/BTC/BSC STC-TB152USB-AT/AS/BTC/BSC Product Specification. Software Trigger USB 2.0 Color / Monochrome SXGA CCD Camera

Maintenance/ Discontinued

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

3G/HD/SD-SDI to HDMI Converter

Transcription:

DMX Relais/Analog Interface 4 User Manual

DMX Relais/Analog Interface 4 2 Description The DMX-Relais/Analog Interface 4 is designed for several controlling tasks. In total, 4 switching contacts and 4 analog output signals are available. The switching contacts are suitable for switching DC voltage as well as AC voltage. A DMX-HOLD function, which can be activated optionally, assumes the switch states and analog values unchanged in the case of fall out the DMX-signal. Technical data Power supply: DMX-Channels: DMX-HOLD: 12-24V DC / 500mA depending on operating mode 4 or 8 channels activable Output: 4 switch max. 8A / 250V~ 165A@20ms inrush current 4 analog signals 0-10V or 1-10V / max. 10mA Dimensions: 99mm x 82mm

DMX Relais/Analog Interface 4 3 Connection DMX IN DMX OUT POWER 12V ADDRESS DMX Relais/Analog Interface 1 2 3 4 POWER POWER ANALOG OUT max. 10mA

LED-Display-Codes DMX Relais/Analog Interface 4 4 The integrated LED is a Multi-functional-display. In the normal DMX-mode the LED flashes non-stop. In this case the device is working. Is the LED permanently dark, there is no DMX512-signal at the entry. Also the LED signalled the operation status. In this case the LED lights up in short pitches and then turns into off modus. The Number of flashing signals is equal to the number of the error status. Error Error Description Status 1 No DMX There is no DMX-signal at the entry 2 Address error Please check the adjusted starting address Addressing The DMX-starting address is adjustable via switch 1to 9. Thereby switch 1 has the valency 2 0 (=1), switch 2 the valency 2 1 (=2) and so on until switch 9 has the valency 2 8 (=256). The sum of the counters showing ON corresponds to the starting address. Address Switch Address Switch 1...... 2 508 3 509 4 510 5 511

DMX Relais/Analog Interface 4 5 Switch Relay by an analog value greater than 0V This mode doesn t use separate DMX-channels for the relays. The relay switches immediately as soon as the analog value is greater than 0V or the DMX-value for the analog output is greater than 0. To activate this mode please set the MODE-Jumper 1: Relay and Analog separate adjustable Relay switches by an analog value greater than 0V In this case the DMX-channel assignment as follows: DMX-channel configuration with 8 Bit: DMX-channel configuration with10 Bit: Start address Start address Analog+Relais 1 Analog+Relais 2 Analog+Relais 3 Analog+Relais 4 Analog+Relais 1 H Analog+Relais 1 L Analog+Relais 2 H Analog+Relais 2 L Analog+Relais 3 H Analog+Relais 3 L Analog+Relais 4 H Analog+Relais 4 L

DMX Relais/Analog Interface 4 6 Resolve the adjusted analog outputs The analog output resolution will be adjusted via the MODE-Jumper 2. The analog outputs are practicable with a resolution of 8 Bit (256 steps) or 10 Bit (1024 steps). 8 Bit (256 steps) 10 Bit (1024 steps) Depending on the resolutions setting the analog output there is needed per output one or two DMX-channels, as shown in the following picture. DMX-channel configuration with 8 Bit: Start address DMX-channel configuration with 10 Bit: Start address Relais 1 Relais 2 Relais 3 Relais 4 Analog 1 Analog 2 Analog 3 Analog 4 Relais 1 Relais 2 Relais 3 Relais 4 Analog 1 HIGH Analog 1 LOW Analog 2 HIGH Analog 2 LOW Analog 3 HIGH Analog 3 LOW Analog 4 HIGH Analog 4 LOW

DMX Relais/Analog Interface 4 7 Setting the output voltage 0-10V / 1-10V The analog outputs output voltage is adjustable via the MODE-Jumper 3: 0-10V 1-10V DMX-HOLD Function The DMX-Relais/Analog Interface has a DMX-HOLD Function which stores the last value in the case of a loss DMX-signal and the relay and the analog outputs assumes in its state unchanged. If the DMX-HOLD Function isn t active, all relays will be shut down in the case of a loss DMX-signal and 0V outputted to the analog outputs. In the case of an power cut the stored values will be rejected! To activate the DMX-HOLD Function use switch 10. Switch 10 ON Switch 10 OFF DMX-HOLD active DMX-HOLD not active

DMX Relais/Analog Interface 4 8 Dimensions (all details in mm)

DMX Relais/Analog Interface 4 9 Equipment Top-hat rail housing 1050 Power supply 12V / 20W

DMX Relais/Analog Interface 4 10 CE-conformity This assembly (board) is controlled by a microprocessor and uses high frequency (8MHz). To get the characteristics of the assembly in relation to the CE-conformity, an installation in a compact metal casing is necessary. Risk-Notes You purchased a technical product. Conformable to the best available technology the following risks should not excluded: Failure risk: The device can drop out partially or completely at any time without warning. To reduce the probability of a failure a redundant system structure is necessary. Initiation risk: For the installation of the board, the board must be connected and adjusted to foreign components according to the device paperwork. This work can only be done by qualified personnel, which read the full device paperwork and understand it. Operating risk: The Change or the operation under special conditions of the installed systems/components could as well as hidden defects cause to breakdown within the running time. Misusage risk: Any nonstandard use could cause incalculable risks and is not allowed. Warning: It is not allowed to use the device in an operation, where the safety of persons depend on this device.

DMX4ALL GmbH Reiterweg 2A D-44869 Bochum Germany Last changes: 09.12.2016 Copyright DMX4ALL GmbH All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another procedure) without written permission or processed, multiplied or spread using electronic systems. All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless errors are to be excluded not completely. For this reason I see myself compelled to point out that I can take over neither a warranty nor the legal responsibility or any adhesion for consequences, which decrease/go back to incorrect data. This document does not contain assured characteristics. The guidance and the characteristics can be changed at any time and without previous announcement.