Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

Similar documents
TruePlate Structural Plate

Field Instruction. Any registered training organisation UETTDRCJ21A Lay ESI electrical cables. Before commencing work:

Selecting the correct cable type for Outside Plant Application

IndyGo Facility Upgrades Project 35671EE

Bolt-A-Plate. We Support You.

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Student Services & Classroom Addition

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Underground Installation of Optical Fiber Cable by Pulling

Aerial Cable Installation Best Practices

3 Locating and Marking Products DOCUMENT OBSOLETE

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

ELECTRICAL SAFETY INSPECTION REPORT

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

1 1/2 13.5, 625 JCASS)

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

Laying of cables and lines in electrical installations and data networks

Cable installation guidelines

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

GUIDELINES FOR CABLE LAYING (PEM ELECTRICAL)

DISCLAIMER. This document is current at the date of downloading. Hunter Water may update this document at any time.

CABLE CLEAT FAQs. Engineering Series. 1. What is a cable cleat?

MXE " 3 Cell MXC "

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

CR Telecommunications Standards January 2006 TELECOMMUNICATIONS STANDARDS

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

MINNEHAHA COUNTY ON-SITE WASTEWATER TREATMENT SITE EVALUATION WORKSHEET Form #1. Land Owner. Legal Description

ELECTRICAL SAFETY INSPECTION REPORT. MTM Garments Ltd.

Aerial Installation Guidelines for Fiber Optic Cable

STRUCTURED CABLE SYSTEM (SCS)

GS122-2L. About the speakers:

High Voltage Cables kv. Handling and Operating Instructions

Cable Installation Tips

Cable Installation Tips

Identification - electrical services

TRAFFIC SIGNAL DESIGN GUIDELINES

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Dynatel Advanced Cable Locator 2250

SECTION CONTROL, COMMUNICATION AND SIGNAL WIRING

TELECOMMUNICATIONS V S WATER UTILITIES NATURE STRIP CONGESTION. Leigh Trevaskis. Riverina Water County Council

APPLICATION OF POWER SWITCHING FOR ALTERNATIVE LAND CABLE PROTECTION BETWEEN CABLE LANDING STATION AND BEACH MAN HOLE IN SUBMARINE NETWORKS

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009

cable, conductor, WIre, hose and FIBre InstallatIon and support MAde easier, SAfer And More dependable installation ProdUcTS TrUSTed innovation

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

Above Ground Cable Installation Systems Selection Guide

Rogers Communication Center Cable Documentation and Identification Policy

Fiberglass - Technical Data

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

CABLE TRAY MANUAL Based on the 2014 National Electrical Code

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION

Public Works Division Lighting District Fiber Optic Specifications April 2009

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

Preparing a home for TransACT fibre-to-the-premise (FTTP) services

My Kohler Generator Installation, Model 20RESD MIKE LIZOTTE MARION, MA.

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone:

Installation Guide OvalSox TM Cable

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Target Interface / Construction Compliance Inspection Checklist

FREEDM Loose Tube Interlocking Armored Cables

SOLO ADSS Short-Span Cables, Fibers

ADS Basic Automation solutions for the lighting industry

2.4 METER SERIES 1250 ANTENNA SYSTEM

Underground Installation of Optic Fiber Cable Placing

SPECIAL SPECIFICATION 6559 Telecommunication Cable

FIBER OPTICS. UNDERGROUND FIBER OPTICS IX Page 1 of 18. Underground Electric Distribution Standards I. ENGINEERING

WIRE AND CABLE FIRE TESTS

SPECIAL SPECIFICATION 8540 Telecommunication Cable

DESIGN CONSULTING ENGINEERS Engineers, Geotechnical, Environmental & Material Scientists

PULL SUPPORT PROTECT CONNECT

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

TUBE AERATION NEXT GENERATION 9000 & INSTALLATION MANUAL

VITALink Taped Splice Straight Through Crimp

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

PTS RABKA TRADE AND PRODUCTION COMPANY

System Troubleshooting for

QuickNet Copper Cabling in the Data Center

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

MDU Fibre In-Building Distribution Network Design and Installation

SUMMARY REPORT. Consultation Summary Report. January 2016

Section Communications Optical Fiber Backbone Cabling

THE CABLE TRAY SYSTEM

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

Transcription:

Tab 10 - The NESC and Underground Applications Restricted Siemens Industry, Inc. 2017 All rights reserved. siemens.com/poweracademy

The National Electric Safety Code (NESC) The NESC provides guidelines for the design of underground systems Section 9 Grounding Methods Part 3 Safety Rules for the Installation and Maintenance of Underground Electric Supply and Communications Lines and Equipment Part 4 Rules for Operation of Electric Supply and Communications Lines and Equipment Underground Cable Systems Page 10-2

NESC 320 Location The underground system should only occupy one lane of travel when installed in a highway or street Special construction required of bridges and railroad tracks Adverse soil conditions can cause movement or corrosion Underground Cable Systems Page 10-3

NESC 320B Separation Distances Separation between Supply and Communication Conduit systems 3 of Concrete or 4 of masonry or 12 of well tamped earth However, lesser distance can be agreed upon Section 320B-4 Water pipes can burst and undermine the supply conduit which in turn can collapse Underground Cable Systems Page 10-4

NESC 321 Excavation and Backfill The backfill should have nothing larger than 4 within 6 of the duct system with the remaining trench having nothing larger than 8 Other construction standards may establish a more stringent requirement The soil conditions may require a protective layer of fill The fill may be required to encompass the duct bank The bottom of the trench should be undisturbed earth or well tamped to avoid settling Underground Cable Systems Page 10-5

NESC 322 Ducts Most utilities have standard stock that is used The duct material must be corrosion resistant The duct system must be designed in a manner that prevents a cable fault in one duct from damaging the cables in an adjacent duct Inside the duct must be free from sharp edges Underground Cable Systems Page 10-6

NESC 323 Manholes The location of the manholes is determined by the location of the opening to the manhole Rule 323A - The duct bank must be able to withstand external loads The manhole must be designed and installed in a manner that will allow it to withstand the external pressures applied Vehicular load is 300 lbs per ft² Requires a 30% increase for live impact Pulling eyes aid the installation of the cable Must be able to withstand 2 times the expected pulling tension Underground Cable Systems Page 10-7

NESC 323 Manholes (continued) Working Space Horizontal spacing is 3 feet minimum Vertical spacing is 6 feet minimum Most new manholes typically have 7 feet of head room Access Round openings have to be 26 or more in diameter to allow for ladder and person (A 32 to 36 diameter is typical for transmission cable because of the large components that must be lowered into the manhole. Two openings are standard) This can be reduced to 24 with fixed ladder Rectangular openings are to be no less than 26 x 22 Underground Cable Systems Page 10-8

NESC 323 Manholes (continued) Covers No real specification is provided by the NESC other than the covers must be secure and not easily removed without tools (Note that a couple of utilities have tethers on their transmission cable manhole covers.) Drainage Be aware of any sewers or storm drains that may allow sewer gas to enter the manhole Ventilation Also covered in Section 4. Mechanical protection of cables Underground Cable Systems Page 10-9

NESC 340 Cable Installation The bending radius is not established in the Code. The Code only states that the radius must be large enough so as not to damage the cable Refer to manufacturer s recommendations Sidewall pressure limit The cable will have a force applied while installing The effects of gravity must be taken into account Supports The cable must be supported in the manhole Called racking the cable The cables must be 3 above the floor or protected The cables will move and the supports and restraint system must be designed to allow this Underground Cable Systems Page 10-10

NESC Section 35 Direct Buried Cable Direct buried cable is any cable not placed in a duct or raceway These rules outline the requirements for any supply or communication cable that is direct buried There is a specific identifier that the cable must display Underground Cable Systems Page 10-11

NESC Section 35 Direct Buried Cable (continued) Installation depth is established in Section 353D This is the minimum depth without mechanical protection; please be aware of the exceptions The trench must be suitable including the backfill No machine tamping within 6 of the cable Care must be taken to not damage the cable during installation Seems like a no brainer but many cables fail due to improper installation Underground Cable Systems Page 10-12

NESC 423 Operating Procedures The requirements of this section include Guarding Testing for Gas Flames Excavation Identification Rules concerning confined space Refer to the OSHA Standards and your Company procedures Underground Cable Systems Page 10-13

NESC Section 44 Understand the rules for working around live or energized equipment will aid in the decision-making process for construction The design and construction of the manhole/duct system is only part of the picture The rest of the picture will be the operation and maintenance of the system for the next 50+ years Underground Cable Systems Page 10-14

Summary The NESC provides the general design and operation guidelines for Underground Electric Supply Lines and Equipment Most Electric Utilities have more stringent requirements NESC are minimums and your Company can establish additional rules Underground Cable Systems Page 10-15