DataSheet SDS1000CFL Series Digital Oscilloscope

Similar documents
DataSheet. SDS1000DL Series Digital Oscilloscope

50 MHz Digital Storage Oscilloscope

DataSheet SDS1000CML Series Digital Oscilloscope

SDS1000C Specifications

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

ADS1000C, CAL / CML Series

Digital Storage Oscilloscopes 2550 Series

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

2016 RIGOL TECHNOLOGIES, INC.

SDS1000CNL+ Series Digital Oscilloscope. DataSheet

SDS1000DL+/CML+ Series Digital Oscilloscope. DataSheet

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

Portable Performance for Debug and Validation

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

Expect to Make Waves.

Agilent Technologies 54522A

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories

ScopeMeter 190 Series Specifications

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

User Manual. Digital Oscilloscope V1.9

User Manual. GPS-1000B+ series. Digital Oscilloscope V 1.1

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

User Manual. SDS1000CFL Series. Digital Storage Oscilloscope SIGLENT TECHNOLOGIES CO,.LTD UM01012-E05A

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

User Manual SDS1000CML+/SDS1000DL+ Digital Oscilloscope UM0101A-E01A SIGLENT TECHNOLOGIES CO,.LTD

User Manual SDS1000DL/CNL/CML. Series Digital Oscilloscope V 1.2 SIGLENT TECHNOLOGIES CO,.LTD

2510 Series Handheld Digital Storage Oscilloscopes

ADS1000 Series Digital Storage Oscilloscope Version No.: V 1.0

PicoScope 6407 Digitizer

User Manual GPS-1000C series

~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.

WaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Agilent Series Oscilloscopes

4CH/2CH Digital Storage Oscilloscopes

25 MHz Digital Storage Oscilloscope

PicoScope 6407 Digitizer

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

Fluke /

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

INSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017

SDS1000X-E Series. Super Phosphor Oscilloscope. DataSheet

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Digital Oscilloscope. Characterisation, Measurement & Analysis

100 MHz Digital Storage Oscilloscope

WAVERUNNER 104XI AND 204XI

WAVESURFER XS SERIES. The Everyday Oscilloscope that s Easy to Use

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Oscilloscopes. the new hmo 3000 SerieS 300 Mhz 400 Mhz 500 Mhz

User s Manual. TDO1000/TDO2000 Series Oscilloscopes

Digital Storage Oscilloscope

Errata. Title & Document Type: Manual Part Number: Revision Date: HP References in this Manual

User Manual. SDS1000X-E Series Digital oscilloscope UM0101X-E02B SIGLENT TECHNOLOGIES CO., LTD.

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Digital Storage Oscilloscope Brief Introduction

GDB-03 Demo Module USER MANUAL GW INSTEK PART NO. 82DB-03000M01 ISO-9001 CERTIFIED MANUFACTURER

PORTABLE OSCILLOSCOPE

Operator s Manual. WaveJet Touch Oscilloscopes

PicoScope 3000 Series HIGH-PERFORMANCE 4-CHANNEL OSCILLOSCOPES

LeCroy Digital Oscilloscopes

PicoScope 9200A PC Sampling Oscilloscopes for Windows PCs

2 MHz Lock-In Amplifier

Fluke 190-Series II Firmware Upgrade V11.44

User Manual. ADS1000 Series Digital Storage Oscilloscope. Version No.: V 1.3. ATTEN Electronics Co., Ltd

Embest DSO2300. Feature. General Description:

20 years of ScopeMeter Test Tool Innovation Introducing the complete 190 Series II Technical Data. New 500 MHz

Datasheet SHF A

Digital Storage Oscilloscope. IDS-700 & IDS-800 Series

Digitizing Oscilloscopes

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

Agilent 6000 Series Oscilloscope Demo Guide

PicoScope 9200A PC Sampling Oscilloscopes for Windows PCs

PicoScope 6000 Series HIGH-PERFORMANCE USB OSCILLOSCOPES

Great Value in Test & Measurement. Mixed Signal Oscilloscopes HMO 3000 SerieS 300 MHz 400 MHz 500 MHz

User Manual. SDS2000 Series Digital oscilloscope UM01020-E03A 2015 SIGLENT TECHNOLOGIES CO., LTD.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Agilent DSO5014A Oscilloscope Tutorial

4CH/2 CH Digital Storage Oscilloscopes Mixed Signal Oscilloscopes

100MHz 2[4] Channel Digital Oscilloscope HMO1022 [HMO1024]

Fluke 19xB-19xC-2x5C. Service Manual. ScopeMeter. models 192B,196B,199B,192C,196C,199C,215C,225C

What is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga

3000 Series. PicoScope. USB oscilloscopes

PicoScope 3000 Series

PC Oscilloscope Spectrum Analyzer Logic Analyzer

TDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

SDS1000X-E Series. Super Phosphor Oscilloscope. DataSheet

20 GHz bandwidth 17.5 ps rise time

350MHz 2[4] Channel Digital Oscilloscope HMO3522 [HMO3524]

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

PicoScope 3000 Series

Minimize your cost for Phased Array & TOFD

Transcription:

DataSheet SDS1000CFL Series Digital Oscilloscope

CHARACTERISTIC: The volume of the oscilloscope is cabinet and it is portable 7 Color TFT LCD display 2/4 channels, Bandwidth: 70MHz-300 MHz Single real-time sampling rate is:2gsa/s, Equivalent sampling rate is 50GSa/s. Memory depth is 24Kpts. Trigger types: Edge, Pulse, Video,Slope and Alternative Unique Digital Filter function and Waveform recorder function Auto measure thirty two parameters and support all measurement function. Two/Four groups reference waveforms and twenty groups capture waveforms and twenty groups setups internal save/recall function and USB flash drive save/recall function. Cursor types: Manual mode, Track mode and Auto mode. Channel waveform and its FFT waveform display on split screen. Waveform Intensity and Grid Brightness can be adjusted. Menu display in the form of pop-up that in order to convenience users to use it. Rich Screen display styles: Classical, Modern, Tradition, Succinct. Multiple Language User Interface. Support Multilingual online help system Standard interface: Double USB Host; USB Device; LAN Port; Pass/Fail Out

Specifications All specification applies to 10X probe and All the SDS1000CFL Series Digital Storage Oscilloscopes. To verify that the oscilloscope meets specifications, the oscilloscope must first meet the following conditions: The oscilloscope must have been operating continuously for thirty minutes within the specified operating temperature. You must perform the Do Self Cal operation, accessible through the Utility menu, if the operating temperature changes by more than 5 C. The oscilloscope must be within the factory calibration interval All specifications are guaranteed unless noted typical. Inputs Input Coupling Input Impedance Maximum voltage input Ch to Ch Isolation (Both channels in same V/div setting) Probe attenuator Probe attenuator Factors Set Vertical System Vertical Sensitivity Channel voltage offset range AC, DC, GND 1MΩ±2% 18Pf±3Pf, 50Ω+/-2%(SDS1304CFL/SDS1302CFL, SDS1204CFL/SDS1202CFL contain this function) 400V (DC+AC PK-PK,1MΩ input impedance, X10),CAT I >100:1 at 150MHz (SDS1304CFL,SDS1302CFL) >100:1 at 100MHz (SDS1204CFL,SDS1202CFL) >100:1 at 50MHz (SDS1104CFL,SDS1102CFL) >100:1 at 35MHz (SDS1074CFL,SDS1072CFL) 1X,10X 1X,5X,10X,50X,100X,500X,1000X 2mV/div -5V/div(1-2-5 order) 2mV-100mV: ±800mV 102mV-5V: ±40V

Vertical Resolution 8 bit Channels 2/4 Analog Bandwidth Single-shot Bandwidth BW Flatness at BNC input Lower frequency limit (AC -3dB) Noise: Pk-Pk for 3K record SFDR including harmonics (measured with FFT) DC Gain Accuracy DC Measurement Accuracy: All Gain settings 100mv/div DC Measurement Accuracy: All Gain settings > 100mv/div Rise time Overshoot, Typical (using 500ps pulse) Ch to Ch Skew (both channels in same V/div setting) 300MHz(SDS1304CFL, SDS1302CFL) 200MHz(SDS1204CFL, SDS1202CFL) 100MHz(SDS1104CFL, SDS1102CFL) 70MHz(SDS1074CFL, SDS1072CFL) 300MHz(SDS1304CFL, SDS1302CFL) 200MHz(SDS1204CFL, SDS1202CFL) 100MHz(SDS1104CFL, SDS1102CFL) 70MHz(SDS1074CFL, SDS1072CFL) DC -10% of rated BW: +/- 1dB 10% - 50% of rated BW: +/- 2dB 50% - 100% of rated BW: + 2dB/-3dB 10Hz(at input BNC) 0.6 Div for average of 10 Pk-Pk readings, Fixed gain settings 0.7 Div for average of 10 Pk-Pk readings, Variable gain settings >=35dB <±3.0%: 5mv/div to 5V/div in Fixed Gain Ranges <±4.0%: 2mv/div Variable Gain Ranges ±[3%* ( reading + offset ) +1% *of offset +0.2div+2mv] ±[3%* ( reading + offset ) +1%* of offset +0.2div+100mv] <1.2ns ( SDS1304CFL, SDS1302CFL ) <1.8ns ( SDS1204CFL, SDS1202CFL ) <3.5ns ( SDS1104CFL, SDS1102CFL ) <5.0ns ( SDS1074CFL, SDS1072CFL ) <10% with probe or BNC input w/ 50 Ohm feed thru <1ns: SDS1304CFL,SDS1302CFL SDS1204CFL,SDS1202CFL SDS1104CFL,SDS1102CFL <2ns: SDS1074CFL,SDS1072CFL (Equivalent to 2 minor divisions in smallest t/div)

Math operation FFT Bandwidth limited Horizontal System Real Time Sampling Rate Equivalent Sampling Rate Measure Display Modes Timebase Accuracy Horizontal Scan Range Trigger System Trigger Types Trigger Source Trigger Modes Trigger Coupling Trigger Level Range Trigger Displacement Trigger Level Accuracy (typical) applicable for the signal of rising and falling time 20ns Trigger Sensitivity Pulse Width Trigger +, -, *, /, FFT Window mode: Hanning, Hamming, Blackman, Rectangular Sampling points: 1024 20MHz ±40% (Note: BW limited below 20MHz when using probe in x1) Single Channel: 2GSa/s, Double Channels: 1GSa/s (When timebase faster than 25ns/div) The highest equivalent sampling rate of other Models is 50GSa/s MAIN, WINDOW, WINDOW ZOOM, ROLL, X-Y ±100ppm measured over 1ms interval 1.0nS/DIV - 50S/DIV Scan: 100mS/DIV ~50S/DIV (1-2.5-5 sequence) Edge, Pulse Width, Video,Slope, Alternative CH1,CH2,CH3,CH4,EXT,EXT/5,AC Line Auto, Normal, Single AC, DC, LF rej, HF rej CH1,CH2,CH3,CH4: ±6divisions from center of screen EXT: ±1.2V EXT/5: ±6V Pre-trigger:(Memory depth/(2*sampling)), Delay Trigger: 260DIV Internal: ±(0.2 div V/div)( within±4 divisions from center of screen) EXT: ±(6% of setting + 40 mv) EXT/5: ±(6% of setting + 200 mv) For fixed gain ranges 1 Divisions: DC-10MHz 1.5 Divisions: 10MHz - Max BW EXT: 200mVpp DC-10MHz, 300mVpp 10MHz - Max BW EXT/5: 1Vpp DC-10MHz, 1.5Vpp 10MHz - Max BW Trigger Modes: (>,<, =)positive Pulse Width, (>, <, =)Negative Pulse Width Pulse Width Range: 20ns 10s

Video Trigger Slope Trigger Alternative Trigger X-Y Mode X-pole Input / Y-Pole Input Sample Frequency Support signal Formats: PAL/SECAM, NTSC Trigger condition : odd field, even field, all lines, line Num (>,<, =) Positive slope, (>,<, =) Negative slope Time: 20ns-10s CH1 trigger type: Edge, Pulse, Video, Slope CH2 trigger type: Edge, Pulse, Video, Slope CH3 trigger type: Edge, Pulse, Video, Slope CH4 trigger type: Edge, Pulse, Video, Slope (CH1) / (CH2) or (CH3)/(CH4) XY mode has a breakthrough that trad oscilloscopes restrict sampling rate at 1MSa/s. Support 25Ksa/s~ 250Msa/s adjusted. Hard Ware Frequency Counter Reading resolution 1 Hz Accuracy ±0.01% Range DC Couple, 10Hz to MAX Bandwidth Signal Types Satisfying all Trigger signals(except Pulse width trigger and Video Trigger) Control Panel Function Auto Set Auto adjusting the Vertical, Horizontal system and Trigger Position Save/Recall Support 2/4 Group referenced Waveforms, 20 Group setups,20 Group captured Waveforms internal Storage/Recall function and USB flash driver storage function. Measure System Auto Measure (32 Types) Cursor Measure Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean,Crms, Vrms, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Rise time, Fall time, Freq, Period,+ Wid,-Wid, +Dut, -Dut, BWid, Phase, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF Manual mode, Track mode and Auto mode

Generic Specification Display System Display Mode Color TFT 7.0in.(177.8mm)diagonal Liquid Crystal Display Resolution 480 horizontal by 234 vertical pixels Display Color 64K color Display Contrast (Typical state) 150:1 Backlight Intensity(Typical state) 300nit Wave display range 8 x 18 div Wave Display Mode Dots, Vector Persist Off, 1 sec, 2 sec, 5 sec, Infinite Menu Display 2 sec, 5 sec, 10 sec, 20 sec, Infinite Screen-Saver Off,1min,2min,5min,10min,15min,30 min,1hour,2hour,5hour Skin Classical, Modern, Tradition, Succinct waveform interpolation Sin(x)/x,Linear Color model Normal, Invert Simplified Chinese, Traditional Language Chinese, English, Arabic, French, German, Russian, Portuguese Spanish, Japanese, Korean,Italian Environments Temperature Cooling Humidity Height Power Supply Input Voltage Frequency Scope Power Mechanical Dimension weight Operating:10 to +40 Not operating: -20 to +60 The fan forces it cold. Operating: 85%RH, 40, 24 hours Not operating: 85%RH, 65, 24 hours Operating: 3000m Not operating: 15,266m 100-240 VAC, CAT II, Auto selection 45Hz to 440Hz 50VA Max length 358mm Width 156mm Height 118mm SDS1004CFL:4.5kg; SDS1002CFL:4.3kg

Type Selections: NAME: SDS1000CFL series Digital Oscilloscope TYPE: SDS1072CFL SDS1074CFL 70MHz SDS1102CFL SDS1104CFL 100MHz SDS1202CFL SDS1204CFL 200MHz SDS1302CFL SDS1304CFL 300MHz Standard Accessories: 1:1/10:1 probe (2/4 PCS based on channels) Power Cable that fits the standard of destination country Qualified Certification. Guaranty Card CD (including EasyScope computer software system) User Manual USB Cable