Parsic Italia Timer Relay Module (FRM01) User Manual

Similar documents
REGO Start&Go USER MANUAL

Operating instructions Electronic preset counter Type series 717

BLOCK OCCUPANCY DETECTOR

Digital output modules

RF Wireless Receiver (Model S4PU-DC-ANT3)

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

DIGITAL TIMER - MODES- rev. 5.5

K-BUS Dimmer Module User manual-ver. 1

PIXEL TOUCH PCB KEEP THIS MANUAL FOR FUTURE NEEDS

Automatic Transfer Switch Control PLC Operator s Manual

Preset counters, electronic

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Digital Ratio Controller

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

STX Stairs lighting controller.

16 Stage Bi-Directional LED Sequencer

SU17 Series Fiber Optic Sensors

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

"shell" digital storage oscilloscope (Beta)

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Art M Digital codelock module

KNX Dimmer RGBW - User Manual

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

Multi-functional safety relay modules PROTECT SRB-E

Standard RS232 RS ma

LED Backlight for Technics amplifiers

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

TRISHALA ELECTROLYTICS PVT LTD BANGALORE

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

Multifunction Digital Timer

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

Electronic Pulse Counter Combination device

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

The UK sequence is shown below. The duration of each phase can be easily adjusted during the programming to suit.

Single Axis Position Controller

Dimming actuators GDA-4K KNX GDA-8K KNX


2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

02/11/2015

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

ARC HEIGHT CONTROL (ARC VOLTAGE CONTROL) MODEL : HAC-01-A-1M

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

K3NX Process Meter OPERATION MANUAL

Gamma instabus. Technical product information

013-RD

Turnout Decoder TD Maxi. User Manual - version 0.1.6

Simply clever! The digital DIN-rail time switches by Grässlin

QUICK START GUIDE FLEXSLICE MODULES

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Absolute Encoders Multiturn

XTAL Bank DDS Version 0.02 Sept Preliminary, highly likely to contain numerous errors

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Model IQ4-PC User Manual Revision Date:

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

WELDING CONTROL UNIT: TE 450 USER MANUAL

Nixie Clock Type Quattro'

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Chapter 5 Flip-Flops and Related Devices

Interface Relays and Optocouplers Product group picture

2-output DALI controller

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

USER S MANUAL. FX2N-8AD Analog input block

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

PRE J. Figure 25.1a J-K flip-flop with Asynchronous Preset and Clear inputs

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Defrost Control Installation and Programming of Version 3.1 Cards

XTM72E & F Real-Time Clock Modules

KNX 1-10V dimmer 4 channels

SceneStyle2 User Guide

ECB DIGITAL ELECTRONICS PROJECT BASED LEARNING PROJECT REPORT ON 7 SEGMENT DIGITAL STOP WATCH USING DECODER

Technical data. General specifications. Indicators/operating means

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Magnecraft Power Relays

Sprite TL Quick Start Guide

MICROMASTER Encoder Module

Pulse Counters, electromechanical

Aspect 2 Circuit Digital Scene Control

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Manual for WMR-252 built-in receiver with universal dimmer

Solid-State Digital Timer

multi-function meters

REMOTE DISPLAY WIRELESS DECODER MK II

Linear flow control with actuator IFC

The outputs are formed by a combinational logic function of the inputs to the circuit or the values stored in the flip-flops (or both).

TUSKIN Equipment Corporation

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

263 Series LED Bargraph Indicator and Controllers

Electrical connection

Sequential and Combination Timer TK-415 with RS-232 communication

Electrical connection

Transcription:

Timer Relay Module (FRM01) User Manual Timer Relay Module (FRM01) User Manual The multifunctional relay control module (FRM01), designed for the customers of different needs, micro-controller as the main control unit, preset 18 kinds of functions, and can be based on user needs, customize and add other specific functions. The module using of high-quality power relay module, high-power and high-voltage transistor, red & blue signal lights, double-sided PCB board, stable performance, can be widely used in a variety of power control occasions. Module Function The user can select one of the following 18 kinds of function according to keys and display, can set and save the parameters of the 18 kinds of function, also can view the current function parameters, time parameter sets the minimum 0.1 second adjustable, more expertise. Gentle remind: Function 1-8 start automatically after power on; function 9-18 start required a high level Pulse signal trigger, and the high level duration 20ms; function 9 is self-locking mode; function 10 is a level control mode. Function 1: Timing Pull-in:after power on, when arrived the setting time T1, the relay pull-in, and the T1 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration 20ms),repeat the above function. Function 2: Timing Disconnect:after power on the relay pull-in, when arrived the setting time T1, the relay disconnect, and the T1 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration 20ms),repeat the above function. 1

Function 3: Timing Pull-in Then Disconnect: after power on, the relay don t pull-in, when arrived the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect,and the T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration 20ms),repeat the above function. Function 4: Timing Disconnect Then Pull-in : after power on, the relay immediately pull-in, when arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay pull-in, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration 20ms),repeat the above function. Function 5: Unlimited Cycle Timing Mode A: after power on, the relay don t pull-in, when arrived the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect,then repeat the above status, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration 20ms),repeat the above function. Function 6: Unlimited Cycle Timing Mode B: after power on, the relay immediately pull-in, when arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay pull-in,then repeat the above status, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration 20ms),repeat the above function. Function 7: Limited Cycle Timing Mode A: after power on, the relay don t pull-in, when arrived the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect,then repeat the above status "NX" times, the T1 and T2 can be adjustable between 0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999, give CH1 interface a high pulse signal(high level duration 20ms),repeat the above function. Function 8: Limited Cycle Timing Mode B: after power on, the relay immediately pull-in, when arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay pull-in,then repeat the above status "NX" times, the T1 and T2 can be adjustable between 0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999, give CH1 interface a high pulse signal(high level duration 20ms),repeat the above function. Function 9: Self-locking Mode:give CH1 interface a high pulse signal, the relay pull-in, again give a high pulse signal, the relay disconnect. Function 10: Trigger Mode:contain delay off function, the relay does not operate after power on,give CH1 interface a high pulse signal, the relay pull-in immediately, when the high pulse signal disappeared, the relay still pull-in, when arrived the setting time T1 relay disconnect, the T1 can be adjustable between 0 second-270 hours. Remark: in this function, if T1 is 0 second, give CH1 connector a high pulse signal, the relay pull-in, when the high pulse signal disappeared, the relay immediately disconnect. Function 11: Trigger timing mode A :the relay does not operate after power on,give CH1 connector a high pulse signal, when arrived the timing time T1, the relay pull-in,t1 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal again, repeat the above function one time. Function 12: Trigger timing mode B:the relay does not operate after power on,give CH1 interface a high pulse signal, the relay pull-in, when arrived the timing time T1, the relay disconnect, T1 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal again, repeat the above function one time. Function 13: Trigger timing mode C :the relay does not operate after power on,give CH1 interface a high pulse signal, when arrived the timing time T1, the relay pull-in,when arrived the timing time T2, the relay disconnect, timing time T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal again, repeat the above function one time. 2

Function 14: Trigger timing mode D:the relay does not operate after power on,give CH1 interface a high pulse signal, the relay pull-in immediately, when arrived the timing time T1, the relay disconnect, when arrived the timing time T2, the relay pull-in, timing time T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal again, repeat the above function one time. Function 15: Unlimited Cycle Timing Mode A:the relay does not operate after power on,give CH1 connector a high pulse signal, when arrived the timing time T1, the relay pull-in, when arrived the timing time T2, the relay disconnect, then repeat the above status, T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal again,repeat the above function. Function 16: Unlimited Cycle Timing Mode B:the relay does not operate after power on,give CH1 interface a high pulse signal, the relay pull-in immediately, when arrived the timing time T1, the relay disconnect, when arrived the timing time T2, the relay pullin, then repeat the above status, T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal again,repeat the above function. Function 17: Limited Cycle Timing Mode A:the relay does not operate after power on,give CH1 interface a high pulse signal, when arrived the timing time T1, the relay pull-in, when arrived the timing time T2, the relay disconnect, then repeat the above status "NX" times, the T1 and T2 can be adjustable between 0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999, give CH1 interface a high pulse signal again,repeat the above function. Function 18: Limited Cycle Timing Mode B:the relay does not operate after power on, give CH1 interface a high pulse signal, the relay pull-in immediately, when arrived the timing time T1, the relay disconnect, when arrived the timing time T2, the relay pullin, then repeat the above status "NX" times, the T1 and T2 can be adjustable between 0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999, give CH1 interface a high pulse signal again,repeat the above function. 3

Operating Instructions The user can select the operating mode according to keys and display, also can set the timing parameters, all parameters can be automatically saved after setting. Below is some noun descriptions about parameter setting: Keys: there are 4 keys, namely: SET SWI, NUM + and NUM-, the keys have short and long press, short press means press the button less than 1 seconds, long press means press the button more than 1 seconds. Operating mode: there are 3 kinds, namely: Operating Mode, Parameter view mode and Parameter setting mode. Digital tube: there are 4 digital display, is used to set or view the user timing parameters. LED : 4 blue parameter indicators, 1 red power indicator. User parameter: there are 4 kinds of parameters can be set (4 blue LED light to indicate the following parameters) MD: MD Light, digital tube displays the current program function, total 18 kinds display mode to choose from (01-18). T1: T1 light, digital tube displays timing time T1, can be 0-9999 seconds. T2: T2 light, digital tube displays timing time T2, can be 0-9999 seconds. NX: NX light, digital tube display the different meanings in different functions. 1. In function 1-6 and 11-16, NX light, the digital tube indicates the time base of T1 and T2, the first two digital tube indicate the timing T1, and behind the two digital tube indicate the timing T2, for example: NXindicates "01 01" means the timing time unit is 1 second; another example: NX indicates "10 02" means the timing time unit of T1 is 10 seconds, T2 is 2 seconds, so the Max timing time is 9999*99 seconds, which is about 270 hours. 2. In function 7 8 17 18, NX light, four digital tube indicates the number of cycles, at this moment, the timing time unit of T1 and T2 is 1 second, so the Max timing time is 9999 seconds in limited cycle timing mode. 4

Keys include long press and short press, and in different modes with different functions, the following is to introduce under three mode key s different functions. Operating mode 1. When turned on, the digital display current timing countdown, when time to zero, that displays the current function number, such as: - - 0 1 means the function 1 2. Short press SET enter into the power saver, the display goes out, but the program to work normally, press again to restore the display; 3. Long press SET enter into Parameter setting mode; 4. Long press SWI enter into Parameter view mode; 5. Long press NUM+ into 10 seconds automatic power saving mode, the digital tube will blink twice, which means that the setting is successful. After entering the power saving mode, if no operation of any button within 10 seconds, the digital display will turn off, but the program running, you can short press SET to restore the display temporarily, you can also long press NUM+ again to exit the automatic power saving mode, the digital tube will blink three times to indicate the setting is successful. 6. Long press NUM- timing reset and stop, again short press NUM- to restore timing, after into reset state, LED lights are no longer flashing. Parameter view mode When turned on, long press SWI enter into parameter view mode, under parameter view mode,can view the parameter of the current function,the blue parameter LED indicator will flash to display. 1. Short press the key SET,cutover the parameters, can choose one from MOD T1 T2 or NX, the LED indicator of the selected parameter will flash, the digital tube display the parameters that have been set. Such as: when T1 light, the digital tube display the content of T1. 2. Long press the key SWI,enter into Operating mode; Parameter setting mode When turned on, long press SET enter into parameter setting mode, under this mode, you can set various parameters, for example, you can select working mode, also can set the delay time etc. 1. Short press the key SET,cutover the parameters, can choose one from MOD T1 T2 or NX, the LED indicator of the selected parameter will long light, the digital tube display the parameters that have been set. Such as: if users need to adjust the working mode, should press the SET to make LED indicators point to MOD. 2. Short press the key SWI,cutover the selected digital tube, the relevant digital tube will flash display. 3. Short press the key NUM+,the selected digital tube numerical +1, add 9 stop; 4. Short press the key NUM-,the selected digital tube numerical -1, reduced to 0 to stop; 5. Long press the key SET,save the parameters, and enter into Operating mode. 5

For Examples Example 1. Control a lamp, automatically to run an hour, then turn off. This application can select the function 2 or function 12, set the parameters: MOD="- - 12", T1="3 6 0 0",T1="xxxx",NX="0 1 x x "(x can be any value, no need),at the same time, the input interface CH1 as the user switch, below is the set-up process: 1>long press SET enter into Parameter setting mode; 2> short press SET, then MOD indicator light, press NUM+ or NUM-, adjust the digital tube display "- - 12"; 3>short press SET, T1 light, set T1="3 6 0 0", T2 no need, X10="0 1 0 1 "; 4>long press SET, save settings, and exit Parameter setting mode, the function starts running immediately. Example 2. When power on, the machine is running 1 hour, stop for 10 minutes, 5 cycles, the machine turns off. This application can select the function 8, set the parameters:mod="- - 0 8",T1="3 6 0 0",T2="0 6 0 0",NX="0 0 0 5". IWiring Reference Gentle remind: If user load and FRM01 module use a seam DC power supply, it is possible because of the power supply capacity is insufficient or wiring connections unfit, the module appears unstable phenomenon occasionally, please use the following (even if no found the problem, it should follow the recommendations): 1. Separate wiring: the positive DC power supply should draw two lines, one link FRM01 of DC + interface for modules, one link NO interface for load use, so the negative power supply should also be dealt with like this. 2. Replace the output current power: If it is the motors and other inductive or capacitive load, the capacity of DC power should choose bigger, such as the use of motor 1A, 3-5A power to choose more reasonable, because the motor starting current is 3-7 times of the rated current, if the power supply capacity is too small, it will result in the voltage dropped instantly and caused FRM01 module reset. 3. Shunt capacitor: If the above two measures fail to achieve the desired effect, please shunt an electrolytic capacitors of 470uf/35V or above capacity between the DC-/DC +. Electrical parameters 1. Operating Voltage:5V/12V/24V(+/-10%) 2. Working Current: 5V / less than 90mA (when the relay is not operating less than 15mA, turn off the display less than 3mA) 12V / less than 50mA (when the relay is not operating less than 15mA, turn off the display less than 3mA) 24V / less than 35mA (when the relay is not operating less than 15mA, turn off the display less than 3mA) 3. Working Temperature:-20 60 (Lim itran ge-30 70 ) 4. Load Capacity: the module normally open interface maximum load capacity: DC 0-30V/10A,AC 0-250V/10A the module normally closed interface maximum load capacity: DC 0-28V/10A,AC 0-125V/10A Restrictions: 1. relay life is loaded with action 100,000 times, and therefore more suitable for use in low frequency and high current pull control of the situation, is not suitable for repeated use in the fast-action situations;. 2. Note consider relay port load margin, purely resistive load more than doubled to left margin, ordinary inductive or capacitive loads must be at least three times more margin. 6

Module Interface Module Voltage/Signal Input:There have three interfaces, all interfaces have terminal, user easy to use. 1.DC+:DC power positive; 2.DC-:DC power negative; 3.CH1:Input signal interface. (3V-30V high voltage to be valid; 0-1.5V low voltage to be invalid; 1.5V-3V voltage is unpredictable, you should avoid this voltage range) Module Output:There have three interfaces, all interfaces have terminal. 1.NO :Normally open interface,the relay becomes vacant before, after pull-in short with the COM; 2.COM:Common interface; 3.NC :Normally closed interface, short with COM before, become vacant after pull-in. V. Module Size 1. Dimensions: 66mm * 40mm * 20mm (L * W * H); 2. Screw Size: 4*ф3.0mm. Screw holes center distance: 59mm * 33mm 7