Substation 3673, Orianna Court

Similar documents
Substation 3262, Exinta Skales

Subject: AC ELF EMF/EMC Magnetic and Electric Field Testing for Good Health Saunas

EFA-200, EFA-300 Field Analyzers

v1.0.0 January AlphaLab, Inc. All rights reserved. TriField EMF Meter Owner s Manual

High Frequency/High Field EMDEX II Specifications

Some considerations relating to SHE Safety Code 23 Working with time-varying electromagnetic fields (EMF)

MachineryMate 800 operating guide Handheld vibration meter

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Electrical Depth CAL IT 2. Brian Smith. Introduction

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System

MATRIX M2 Loudspeaker system

INNOVATION IN MAGNETICS DS3434/5. Mag612. Miniature Three-Axis Fluxgate Probe.


THE RESEARCH COMMITTEE FOR TOTAL ENERGY THE ENERGY CONSERVATION STANDARDS WORKING GROUP SUMMARY OF FINAL CRITERIA

GS Bloch Equations Simulator 1. GS Introduction to Medical Physics IV Exercise 1: Discrete Subjects

Amorphous Alloys for Transformer Cores

SC26 Magnetic Field Cancelling System

TRAN-COR H. grain ORIENTED ELECTRICAL STEELS. Applications Potential. a significant increase in core loss.

PowerMonic. FAQs [2/12]

Linrad On-Screen Controls K1JT

Frequency Converter Fv

Specially designed for compatibility with industry standard

1 Power Protection and Conditioning

TRAN-COR H-0 CARLITE H-0 CARLITE DR H-1 CARLITE H-1 CARLITE DR H-2 CARLITE H-2 CARLITE DR

TELETEST Ltd 4-6 Shelley Road, Bournemouth, BH1 4HY, UK Tel: Intl: Web:

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI

ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS

CARLITE grain orien TEd ELECTRICAL STEELS

PRODUCT FAMILY DATASHEET LEDVANCE SPOT LED FIREPROOF

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Toronto Hydro - Electric System

9070 Smart Vibration Meter Instruction Manual

QuickField simulation report

Vicon Valerus Performance Guide

CONSUMER UPS SINGLE PHASE UPS UP TO 3000 VA THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Emerging Subsea Networks

Product Data Sheet 4656 EZ

Measurement User Guide

Product Data Sheet 4656 ZW

Electrical Depth Work

Product Data Sheet 8506 VW-691

An Introduction to Vibration Analysis Theory and Practice

MAINS DISTRIBUTION GUIDE

Joint paper: Feasibility and technical aspects of partial undergrounding of extra high voltage power transmission lines

White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle. Introduction and Background:

Advanced Test Equipment Rentals ATEC (2832)

TeSys circuit-breakers

Hands-on session on timing analysis

How to Describe a Color Trademark in an Application (how to fill out the section "Detailed explanation of the trademark")

Improving Lightning Protection of Power Systems with Externally Gapped Line Arresters (EGLA)

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Signal Stability Analyser

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

Automatic Test System AT-S + with STAR + Technology Features

LEDVANCE DOWNLIGHT LED

Organ Tuner - ver 2.1

Getting Started Guide

1C.5.1 Voltage Fluctuation and Flicker

INSTRUCTION MANUAL COMMANDER BDH MIG

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

First Floor Community Corridor

Scanner PERENITY 5K The best complete scanning solution for Archives

Touch Panel RGB LED Controller Part No. touch-panel-rgb

System Satellites Acoustimass Module. 2.5" (64 mm) full-range driver (per satellite) 5.25" (133 mm) dual voice coil low frequency driver

GFT Channel Slave Generator

14/09/98 Martin Casemanual (Version 6.21) The effect generator PRESS : $, 7

NMR. picospin. Maintenance Guide

General Specifications

Comverge PowerPortal In-Home Display (IHD) User Guide for Members of New Hampshire Electric Cooperative

Acoustimeter User Manual

R 95 SAFE AREAS FOR 16:9 TELEVISION PRODUCTION VERSION 1.1 SOURCE: VIDEO SYSTEMS

Leer Ice Vending Machines

Erasing 9840 and 9940 tapes

LED Driver Linear / area fixed output

9.5 Add or Remove Samples in Single Access Mode

IP Roombox. Hotel Room Management

RGB LED Controller and Dimmer Pro Plus RF Remote 3-Channels, 12 or 24 VDC Part No. RGB-3-Dimmer-Pro

New DSP Family Traffic Control Plus Feature

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Composite Distortion Measurements (CSO & CTB)

TECHNICAL RIDER African Roads, American Streets

Zwick. Materials testing. Product Information Specimen blanking machines for specimen preparation of metals

Hazard Surveillance for Industrial Magnetic Fields: II. Field Characteristics from Waveform Measurements

Clean Multi Scale. Automatic Combination Weigher

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Certificate of Calibration

LED Driver Compact fixed output

HERO OPTION #1. Guidelines and Specs for Standard Sponsorship

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

456 SOLID STATE ANALOGUE TAPE + A80 RECORDER MODELS

IMPORTANT SAFETY INSTRUCTIONS

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 PURPOSE 2.0 SCOPE 3.0 CODES, STANDARDS AND REFERENCES

TOWARDS IMPROVING ONSET DETECTION ACCURACY IN NON- PERCUSSIVE SOUNDS USING MULTIMODAL FUSION

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

King Fahd University of Petroleum and Minerals Electrical Engineering Department 1. Homework 5 - SOLUTION KEY

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

DRAWING GRAPHS OF OCCULTATIONS BY ASTEROID EVRERY 20mS

Transcription:

On the 9th of November 2006 at 9:30 am magnetic field measurements were performed for Substation 3673 Orianna Court. The substation of interest is located on the ground floor of the Orianna Court Building, Eleftheroupoleos Street in Nicosia. {mosmap width='500' height='400' lat='35.157000' lon='33.367167' zoom='18' zoomtype='large' zoomnew='0' maptype='satellite' showmaptype='1' overview='0' text='substation 3673, Orianna Court' tooltip='dwo' marker='1' align='center' key='abqiaaaa03cwbwhnzyjizsn-wwdqmhqctkyp5l8hb2mjngvvfkvpdgzbixqkqitrafigip chx6gplphdidvzga'} Σελίδα 1 / 23

The substation is rated at a nominal power of 630 KVA. Measurements were performed when the building containing the substation was powered and off. At the time when the measurements were performed and when the building was fully operational, the substation load was recorded as: Red Phase Yellow Phase Σελίδα 2 / 23

Blue Phase 180A 140A 140A Table 1: Measured Load Current when building was fully operating The Resultant load of all three phases as shown is only 17% of the nominal load (630KVA Transformer). Accordingly the load was also recorded when Orianna Courtn was powered off and is represented in the following table: Red Phase Yellow Phase Blue Phase 180A 140A 140A Table 2: Measured Load Current when Orianna Court was powered off By calculating the Resultant load of all three phases as shown above we note that the load is only 19% of the nominal load (630KVA Transformer). It must therefore be noted that during the summer or in periods of peak load the electric and magnetic fields are expected to be higher. Limiting exposure values have been provided by the ICNIRP recommendations and are guidelines to many countries and organizations. The exposure limits at 50 Hz are tabulated in the following table according to the limits given by ICNIRP. Σελίδα 3 / 23

Reference levels for Occupational exposure ICNIRP Frequency Electric Field Strength, E (V/m) Magnetic Field Strength, H (A/m) Magnetic Flux Density, B (µt) 50 Hz 10000 400 500 Reference levels for General Public exposure ICNIRP Frequency Electric Field Strength, E (V/m) Magnetic Field Strength, H (A/m) Magnetic Flux Density, B (µt) 50 Hz 5000 80 100 Table 3: ICNIRP exposure limits for Occupational and General Public exposure The obtained results for the RMS fields inside and outside the substation are shown in tables 4 and 5 respectively in the case when Orianna Court is on. A comparison is also made with the ICNIRP recommendations. Σελίδα 4 / 23

Substation 3673 Orianna Court: Fields Inside Substation when Orianna Court was on Distance from Side (m) Maximum Magnetic Field (µt) at Z Height (m) Percentage of ICNIRP Occupational Standard (%) 0.3m 1m 1.75 m Inside Substation Field Measurements (Distance from Left Inside Wall) 0m from Left Side 207.22 41.44% 111.53 22.31% 59.94 11.99% 0.5m from Left Side 98.84 19.77% 61.36 12.27% 42.01 Σελίδα 5 / 23

8.40% 1m from Left Side 22.23 4.45% 18.25 3.65% 11.25 2.25% 1.5m from Left Side 57.95 11.59% 50.20 10.04% 12.95 2.59% 2m from Left Side 278.44 55.69% 282.08 56.42% 258.51 51.70% 2.5m from Left Side 12.04 Σελίδα 6 / 23

2.41% 43.00 8.60% 11.06 2.21% 3m from Left Side 13.89 2.78% 17.39 3.48% 2.94 0.59% 3.5m from Left Side 14.36 2.87% 10.65 2.13% 2.57 0.51% Table 4: Maximum Field Measurements inside Substation 3673 (Orianna Court on) Substation 3673 Orianna Court: Fields Outside Substation when Orianna Court was on Distance from Side (m) Maximum Magnetic Field (µt) at Z Height (m) Σελίδα 7 / 23

Percentage of ICNIRP General Public Standard (%) 0.3m 1m 1.75 m Substation's left side field measurements 0m from Left Side 10.90 10.90% 23.33 23.33% 12.69 12.69% 1m from Left Side 3.67 3.67% 3.87 3.87% 2.06 2.06% 2m from Left Side Σελίδα 8 / 23

0.99 0.99% 0.88 0.88% 0.70 0.70% 3m from Left Side 0.62 0.62% 0.40 0.40% 0.34 0.34% Table 5: Maximum Field Measurements outside Substation 3673 (Orianna Court on) Accordingly the obtained results for the RMS fields inside and outside the substation in the case when Orianna Court was powered off, are shown in tables 6 and 7 respectively. A comparison is again made with the ICNIRP recommendations. Substation 3673 Orianna Court: Fields Inside Substation when Orianna Court was off Distance from Side (m) Maximum Magnetic Field (µt) at Z Height (m) Percentage of ICNIRP Occupational Standard (%) 0.3m Σελίδα 9 / 23

1m 1.75 m Inside Substation Field Measurements (Distance from Left Inside Wall) 0m from Left Side 25.77 5.15% 89.86 17.97% 30.65 6.13% 0.5m from Left Side 76.21 15.24% 40.00 8.00% 39.23 7.85% 1m from Left Side 34.33 6.87% 28.83 5.77% Σελίδα 10 / 23

15.63 3.13% 1.5m from Left Side 75.87 15.17% 69.52 13.90% 27.15 5.43% 2m from Left Side 334.42 66.88% 574.33 114.87% 32.96 6.59% 2.5m from Left Side 22.94 4.59% 47.00 9.40% 18.95 3.79% 3m from Left Side Σελίδα 11 / 23

19.85 3.97% 18.88 3.78% 2.05 0.41% 3.5m from Left Side 18.37 3.67% 6.71 1.34% 2.14 0.43% Table 6: Maximum Field Measurements inside Substation 3673 (Orianna Court was off) Substation 3673 Orianna Court: Fields Outside Substation when Orianna Court was off Distance from Side (m) Maximum Magnetic Field (µt) at Z Height (m) Percentage of ICNIRP General Public Standard (%) 0.3m 1m 1.75 m Σελίδα 12 / 23

Substation's left side field measurements 0m from Left Side 18.48 18.48% 23.18 23.18% 4.66 4.66% 1m from Left Side 1.95 1.95% 2.05 2.05% 1.05 1.05% 2m from Left Side 0.90 0.90% 0.73 0.73% 0.54 0.54% Σελίδα 13 / 23

3m from Left Side 0.61 0.61% 0.42 0.42% 0.30 0.30% Table 7: Maximum Field Measurements outside Substation 3673 (Orianna Court off) Apartment No.1, above Substation 3673 Apartment No 1 of Orianna Court is situated on the first floor of the building, directly above the substation. Field measurements for this apartment were performed on the 9th of November 2006 at 11:00am. Magnetic field measurements were performed in the apartment for both the case when power supplied to the building was on and off. The obtained results for the RMS magnetic fields inside the apartment above the substation, when Orianna Court was on, are shown in table 8 and a comparison is made with the ICNIRP recommendations. Apartment No 1: Inside Maximum Field Measurements Building on Distance from Side (m) Maximum Magnetic Field (µt) at Z Height (m) Percentage of ICNIRP General Public Standard (%) 0.3m 1m Σελίδα 14 / 23

1.75 m Apartment Inside Field Measurements from Left Side Wall of Bedroom 1 0m from Left Wall 0.79 0.79% 0.37 0.37% 0.24 0.24% 1m from Left Wall 1.27 1.27% 0.47 0.47% 0.23 0.23% 2m from Left Wall 0.72 0.72% 0.71 0.71% 0.50 Σελίδα 15 / 23

0.50% 3m from Left Wall 0.49 0.49% 0.31 0.31% 0.25 0.25% Apartment Inside Field Measurements from Right Side Wall of Kitchen 0m from Right Wall 0.30 0.30% 0.50 0.50% 0.63 0.63% 1m from Right Wall 0.43 0.43% 0.25 0.25% 0.17 0.17% Σελίδα 16 / 23

2m from Right Wall 0.81 0.81% 0.34 0.34% 0.43 0.43% 3m from Right Wall 0.30 0.35% 0.19 0.19% 0.28 0.28% Apartment Inside Field Measurements Centre of Corridor Center of Room 0.16 0.16% ----Apartment Inside Field Measurements Centre of Bathroom Σελίδα 17 / 23

Center of Room 0.20 0.20% ----Apartment Inside Field Measurements Centre of Living Room Center of Room 0.17 0.17% ----Apartment Field Measurements Centre of Veranda Center of Veranda 0.29 0.29% Σελίδα 18 / 23

Table 8: Maximum Field Measurements inside Apartment No 1 above SS 3673 (Building on) Finally the obtained results for the RMS magnetic fields inside the apartment above the substation, when the building was off, are shown in the table below and a comparison is again made with the ICNIRP recommendations. Apartment No 1: Inside Maximum Field Measurements Building powered off Distance from Side (m) Maximum Magnetic Field (µt) at Z Height (m) Percentage of ICNIRP General Public Standard (%) 0.3m 1m 1.75 m Apartment Inside Field Measurements from Left Side Wall of Bedroom 1 0m from Left Wall 0.49 0.49% 0.23 0.23% 0.16 0.16% 1m from Left Wall Σελίδα 19 / 23

0.66 0.66% 0.31 0.31% 0.24 0.24% 2m from Left Wall 0.56 0.56% 0.30 0.30% 0.19 0.19% 3m from Left Wall 0.33 0.33% 0.22 0.22% 0.18 0.18% Apartment Inside Field Measurements from Right Side Wall of Kitchen 0m from Right Wall 0.38 0.38% Σελίδα 20 / 23

0.28 0.28% 0.23 0.23% 1m from Right Wall 0.35 0.35% 0.47 0.47% 0.24 0.24% 2m from Right Wall 0.23 0.23% 0.20 0.20% 0.12 0.12% 3m from Right Wall 0.12 0.12% 0.19 0.19% 0.13 Σελίδα 21 / 23

0.13% Apartment Inside Field Measurements Centre of Corridor Center of Room 0.14 0.14% ----Apartment Inside Field Measurements Centre of Bathroom Center of Room 0.20 0.20% ----Apartment Inside Field Measurements Centre of Living Room Center of Room 0.17 0.17% --Σελίδα 22 / 23

--Apartment Field Measurements Centre of Veranda Center of Veranda 0.31 0.31% Table 9: Maximum Field Measurements inside Apartment No 1 above SS 3673 (Building powered off) Σελίδα 23 / 23