Termination Instructions. FO Patch panel OV-A / OV-AT 19 /1U. Cabling Solutions

Similar documents
Installation and handling of. elevator flat cable system and Compensation weight CW. Cabling Solutions

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

INSTALLATION INSTRUCTIONS

HCS - HES Cabling Systems

Medium Box for Cable Termination

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

IP-LINX Fiber :: X-XXXX

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

LANmark-OF ENSPACE Patch Panel

IP-LINX. Installation Guide

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Optical Distribution Box 300 Installation Guide. Version : R0.0

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

3M Distribution Box (DDB)

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

INSTALLATION INSTRUCTIONS MO023A

INSTALLATION INSTRUCTIONS

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

Assembly Instructions

6000 Series Patch Panel Terminating Instructions

PRODUCT DESCRIPTION N3S

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

Opterna. Sliding Fiber Optic Patch Panel. Sliding Fiber Optic Patch Panel. Visit: Opterna.com. Data Center Solutions. Introduction

Best Friends General Trading FZE

PRODUCT DESCRIPTION N3S

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Gel-sealed in-line fiber optic closure

Panduit Recommended Best Case Practice Split Fibre

3 Cleaning. 4 Technical data

3M Fiber Optic Wall Mount Enclosure 8430 Series

FIBRE OPTIC CABLE SOLUTIONS

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

3M Coupling Tray FDTC-10S-COUPLINGTRAY

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

Connectix Cabling Systems

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

Data and communication Connection technology for commercial switch programs

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Section Communications Optical Fiber Backbone Cabling

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

SECTION COMMUNICATIONS HORIZONTAL CABLING

Follow The Leader In Shielded Technology

FOSC 450 C6 and D6 Closures

KVT Split cable glands

TITLE: FIBER OPTIC SHOCK FIXTURES

Structured Cabling. Product Line Brochure

Preventing Fieldbus Physical Layer Problems

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

3M Fiber Closures BPEO

Connecting cables for valves, round plug connectors Product range overview

Infinity Fibre Distribution Frame

Installation Instructions

Cold Shrink Straight Joint

24 Volt RGB/RGA Super Flat LED Rope Part Numbers: SFR-RGB-W, SFR-RGB-B, SFR-RGA-W, SFR-RGA-B

TECHNICAL DATA. Type. TMC2X Design Specification. Category B ATEX Certificate. Code of Protection. IECEx SIR X Code of Protection

Connectivity accessories by Nestor Cables

3. Electronics and MMU2 unit assembly

3M Better Buried Compound Compression Closure System

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

Crimp & Cleave Termination Instructions for SEL ST Connectors

INSTALLATION MANUAL FOR THE TIMING LIGHT

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Control cabinet interface and cable entry systems

RetractaNet XS. Extractable Solutions for OSP. October 2012

SLiC Fiber Aerial Closure System

Data Sheet IP67 Mast Enclosure

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

Original BMW Accessory. Installation Instructions.

Quickreference: Cat.6A EL / Class EA unshielded. Horizontal floor cabling subsystem with unshielded twisted pair technology

Single sensor setup with NIVEL210

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Non Magnetic Connectors

Coyote popup display set up instructions

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

SECTION 4 TABLE OF CONTENTS

Heating films. Articelnumber build:

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

Fiber ICT. Optical Fiber Catalogue

Main Products. Cable Assemblies Wire Harnesses Raw Cables. Connectors

Pendant Light Fitting IEC Series 6470/2

SECTION 7 -- CROSS-CONNECT SYSTEMS


Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

PNP300 / PNP300UN / PNP350

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

ART2000i Digital Dimming System. Installation guide. Stock number *8200-

KVT Split cable glands

Public Works Division Lighting District Fiber Optic Specifications April 2009

HDBT Installation Guide

Roof-mounted Blue e+ cooling unit Integration solution VX25

Smart Choices. for Data Center

Bionic Elephant Trunk. Assembly Instructions

FIST-GCO2 GCO2-BC8 GCO2-BD8 GCO2-BE8 GCO2-BF8. 5 Heatshrink installation. 1 Introduction. Content. 6 Fiber routing. 2 General. 7 Fiber routing on tray

Transcription:

Termination Instructions FO Patch panel OV-A / OV-AT 19 /1U, 2U FO splice box OV-A 19 /1U Cabling Solutions

FO Patch panel OV-A / OV-AT 19 /1U, 2U 1a 1b Distribution head outside the box with restricted fitting (straight entry) Distribution head outside the box with restricted fitting (sloped entry) 2a 2b Distribution head outside the box with the lock of the protection tube of the cable distributor (straight entry) Distribution head outside the box with the lock of the protection tube of the cable distributor (sloped entry) 3a 3b Distribution head inside the box with the split in the distribution head (straight entry) Distribution head inside the box with the split in the distribution head (sloped entry) 2

1. The complete box is fixed to the selected position in the 19 frame. 2. Enter the trunk cable with the distribution head from the rear of the box. Attention: The length of the cable behind the fixing in the box shall be a minimum 1.5m.This allows demounting of the box for later re-working. 3. The protection tube is demounted from the distribution head. The single fibre cable with the terminated connectors will not be damaged if the protection tube is carefully pulled back. 4. The distribution head is fixed with the chosen fixture plate (straight or sloped). The cable is taken through the cable guide plate and the cable gland is screwed tight. Attention: It is possible to demount the cable entry from the box before mounting the cable. 5. The head including the terminated connectors is pulled from the back side in the chosen position of the box. After them the complete unit (cable distributor and fixture plate) is inserted and fixed (with screws) to the selected position (they are the positions left and right on the back of the box). 6. The box is pulled out and the fibres brought to the right position. The fibres/connectors are labelled. 7. Attention: Please follow the cleaning and security regulations. The box entry with mounted distribution head is sloped insert the slot in the back of the box. Then the head is pulled back. The pin of the cable entry plate must snapped into the sidewall of the box. 3

FO Splice box OV-A 19 /1U 1 1. The complete box is fixed to the selected position in the 19 frame. 2. Cable stocks into account, so that the box for future assembly work can be expanded. Attention! Bundle artery supplies to the desired length apart. (About 1.50 m) 3. Use the right cable gland (PG or metric) and mount on cable. 4. The cable is taken through the cable guide plate and the cable gland is screwed tight. Attention: It is possible to demounted the cable entry from the box before mounting the cable. 5. The complete entry including the fixed cable is inserted and fixed to the selected position (they are the position left and right on the back of the box). 6. The box is pulled out and taken out for splice works. 7. The lowest splice cassette is for twelve coloured fibres (IEC60304). 8. Attention: If you have more than 12 fibres the colour code is repeated. 9. The loose tube and the pigtails are fixed on the splice cassettes with a tie wrap or another fixing method. This must be done without twisting the fibres. To avoid macro bending no pressure must be applied to the fibres. 10. Prepare the loose tube to the right length. Clean the fibres with ultrapure alcohol and take the fibres contrary the fibres of the pigtails in the cassette. 11. Splice the fibres in compliance with the instructions and protect the splice with a crimp or heat shrink splice protector and put the protector in the holder. 12. Attention: Please follow the cleaning and security regulations. Size ( Cable gland) M20 / PG11 M25 / PG13.5 Klemm area 6-12 mm 9-16 mm 4

cable entries for FO patch panels OV-A / OV-AT 1U Size Article No. Description M25 417550 Angled cable entry M20 417559 Angled cable entry M20 + M25 416994 Straight cable entry 1x 21 mm + 2x 15 mm 418650 Straight cable entry 15 mm 418652 Angled cable entry 21 mm 418654 Angled cable entry 2x M20 415208 Angled cable entry 2U Size Article No. Description M25 417560 Angled cable entry M20 417562 Angled cable entry M20 + M25 417561 Straight cable entry 1x 21 mm + 2x 15 mm 418651 Straight cable entry 15 mm 418653 Angled cable entry 21 mm 418655 Angled cable entry 2x M20 415209 Angled cable entry 5

Adressen Dätwyler Gesellschaften / Datwyler Companies Switzerland Dätwyler Cabling Solutions AG Gotthardstrasse 31 6460 Altdorf T + 41 41 875-1268 F + 41 41 875-1986 info.cabling.ch@datwyler.com Germany Dätwyler Cables GmbH Auf der Roos 4-12 65795 Hattersheim T + 49 6190 8880-0 F + 49 6190 8880-80 info.cabling.de@datwyler.com Dätwyler Cables GmbH Lilienthalstraße 17 85399 Hallbergmoos T + 49 811 998633-0 F + 49 811 998633-30 info.cabling.de@datwyler.com Austria Dätwyler Cables GmbH Office Austria Tenschertstraße 8 1230 Wien T + 43 1 8101641-0 F + 43 1 8101641-35 info.cabling.at@datwyler.com United Arab Emirates Datwyler Middle East FZE P. O. Box 263480 Office No. 601, 6th Floor, Jafza 19 View Jebel Ali Free Zone Dubai T + 971 4 8810239 F + 971 4 8810238 info.cabling.ae@datwyler.com Datwyler Cabling Solutions LLC Unit 1004 & 1005, 10th Floor, IB Tower Business Bay Dubai T + 971 4 4228129 F + 971 4 4228096 info.cabling.ae@datwyler.com China Datwyler Cables+Systems (Shanghai) Co. Ltd Building 16, No. 111, Kang Qiao Dong Road Kang Qiao Industrial Zone, Pudong Shanghai, 201319 T + 86 21 6813-0066 F + 86 21 6813-0298 info.cabling.cn@datwyler.com Datwyler (Suzhou) Cabling Systems Co. Ltd Block 31, 15# Dong Fu Road Suzhou Singapore Industrial Park Suzhou, 215123 T + 86 512 6265-3600 F + 86 512 6265-3650 harnessing.cabling.cn@datwyler.com Singapore Datwyler (Thelma) Cables+Systems Pte Ltd 29 Tech Park Crescent 638103 Singapore T + 65 68631166 F + 65 68978885 info.cabling.sg@datwyler.com Datwyler - MA - OV-A / -AT - e - 01/14 Subject to technical modification. Datwyler - MA - OV-A / -AT - e - 08/13