TeSys circuit-breakers

Similar documents
GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Main. Device short name. Device application

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Bulletin 190 IEC Modular Starter System

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV2ME. Main. Device short name. Device application

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2P05. Main. Device short name. Device application

AS09..S 3-pole Contactors - Spring Terminals

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Features XT SC 012 B B A

Features XT SC 012 B B A

DMX and 4000 air circuit breakers from 800 to 4000 A

Selection guide siemens.com/sirius-modular-system

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Magnetic and Hydraulic-Magnetic Circuit Breaker

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Circuit-Breakers for Motor Protection Series 8523/8

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

High performance circuit breakers

Series CT7N Bimetallic Overload Relays

Power Circuit of a UL508A Panel. Typical UL489 Application

XT IEC Power Control Combination Motor Controllers

Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Manual Motor Starter Specifcations

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

A V 50Hz / V 60Hz

Variable speed drives Altivar Process Three-phase supply voltage: V 50/60 Hz Wall-mounting drives

02/11/2015

llen-bradley 194R-HM4-NFPA3

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Modular pulse operated latching relay 16 A

Kuhnke Technical Data. Contact Details

Type: DILM25 10(24V50HZ) Article No.:

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Type: DILM12 10(24VDC) Article No.:

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

SQM40/41 Actuators for air and gas dampers

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

Data Sheet Definite Purpose Contactors Ex9CK Series

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

8 Installation Equipment

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Bulletin 190 Compact. Combination Starters

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kv, Gas-Insulated

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

AC1036. Definite Purpose Contactors

Identification - electrical services

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

Pushbutton Units and Indicator Lights

Systems Pow-R Breakers Renewal Parts and Accessories

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

16 A and 25 A power contactors with or without handle

Transcription:

Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping 50/60 Hz in category AC- of current 400/415 V 500 V 690 V thermal Id ± 20 % P Icu Ics P Icu Ics P Icu Ics trips (2) (2) (2) () kw ka kw ka kw ka A A kg 0.1 0.16 1.5 GV2-ME01 0.260 GV2-ME 0.06 g g 0.16 0.25 2.4 GV2-ME02 0.260 0.09 g g 0.25 0.40 5 GV2-ME0 0.260 0.12 g g 0.7 g g 0.40 0.6 8 GV2-ME04 0.260 0.18 g g 0.40 0.6 8 GV2-ME04 0.260 0.25 g g 0.55 g g 0.6 1 1 GV2-ME05 0.260 0.7 g g 0.7 g g 1 1.6 22.5 GV2-ME06 0.260 0.55 g g 0.55 g g 0.75 g g 1 1.6 22.5 GV2-ME06 0.260 0.75 g g 1.1 g g 1 1.6 22.5 GV2-ME06 0.260 0.75 g g 1.1 g g 1.5 75 1.6 2.5.5 GV2-ME07 0.260 1.1 g g 1.5 g g 2.2 75 2.5 4 51 GV2-ME08 0.260 1.5 g g 2.2 g g 75 2.5 4 51 GV2-ME08 0.260 2.2 g g 50 100 4 75 4 6. 78 GV2-ME10 0.260 g g 4 10 100 5.5 75 6 10 18 GV2-ME14 0.260 4 g g 5.5 10 100 7.5 75 6 10 18 GV2-ME14 0.260 5.5 15 50 7.5 6 75 9 75 9 14 170 GV2-ME16 0.260 11 75 9 14 170 GV2-ME16 0.260 7.5 15 50 9 6 75 15 75 1 18 22 GV2-ME20 0.260 9 15 40 11 4 75 18.5 75 17 2 27 GV2-ME21 0.260 11 15 40 15 4 75 20 25 27 GV2-ME22 (4) 0.260 15 10 50 18.5 4 75 22 75 24 2 416 GV2-ME2 0.260 Thermal-magnetic circuit-breakers GV2-ME with built-in auxiliary contact block With instantaneous auxiliary contact block (composition, see page /): -GV-AE1, add suffix AE1TQ to the motor circuit-breaker reference selected above. Example: GV2-ME01AE1TQ. -GV-AE11, add suffix AE11TQ to the motor circuit-breaker reference selected above. Example: GV2-ME01AE11TQ. -GV-AN11, add suffix AN11TQ to the motor circuit-breaker reference selected above. Example: GV2-ME01AN11TQ. These circuit-breakers with built-in contact block are sold in lots of 20 units in a single pack. (1) For bulk packs of GV2-ME, see page 1/51. (2) As % of Icu. () For use of GV2-ME in an enclosure, see pages /8 and /9. (4) Maximum rating which can be mounted in enclosures GV2-MC or MP, please call our Customer information centre on 0870 608 8 608. g > 100 ka. /5 to /7 & /25 to /0 pages /4 to /48 pages /49 to /51 Schneider Electric /1

Thermal-magnetic motor circuit-breakers type GV2-P GV2-P with rotary knob and screw clamp terminals Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping 50/60 Hz in category AC- of current 400/415 V 500 V 690 V thermal Id ± 20 % P Icu Ics P Icu Ics P Icu Ics trips (1) (1) (1) (2) kw ka kw ka kw ka A A kg 0.1 0.16 1.5 GV2-P01 0.50 GV2-P 0.06 g g 0.16 0.25 2.4 GV2-P02 0.50 0.09 g g 0.25 0.40 5 GV2-P0 0.50 0.12 g g 0.7 g g 0.40 0.6 8 GV2-P04 0.50 0.18 g g 0.40 0.6 8 GV2-P04 0.50 0.25 g g 0.55 g g 0.6 1 1 GV2-P05 0.50 0.7 g g 0.7 g g 1 1.6 22.5 GV2-P06 0.50 0.55 g g 0.55 g g 0.75 g g 1 1.6 22.5 GV2-P06 0.50 0.75 g g 1.1 g g 1 1.6 22.5 GV2-P06 0.50 0.75 g g 1.1 g g 1.5 8 100 1.6 2.5.5 GV2-P07 0.50 1.1 g g 1.5 g g 2.2 8 100 2.5 4 51 GV2-P08 0.50 1.5 g g 2.2 g g 8 100 2.5 4 51 GV2-P08 0.50 2.2 g g g g 4 6 100 4 6. 78 GV2-P10 0.50 g g 4 50 100 5.5 6 100 6 10 18 GV2-P14 0.50 4 g g 5.5 50 100 7.5 6 100 6 10 18 GV2-P14 0.50 5.5 g g 7.5 42 75 9 6 100 9 14 170 GV2-P16 0.50 11 6 100 9 14 170 GV2-P16 0.50 7.5 50 50 9 10 75 15 4 100 1 18 22 GV2-P20 0.50 9 50 50 11 10 75 18.5 4 100 17 2 27 GV2-P21 0.50 11 50 50 15 10 75 20 25 27 GV2-P22 0.50 15 50 50 18.5 10 75 22 4 100 24 2 416 GV2-P2 0.50 (1) As % of Icu. (2) For use of GV2-P in an enclosure, see pages /8 and /9. g > 100 ka. /5 to /7 & /25 to /0 pages /4 to /48 pages /49 to /51 /2 Schneider Electric

Thermal-magnetic motor circuit-breakers type GV2-ME Thermal-magnetic circuit-breakers GV2-ME with spring terminal connections (1) Pushbutton control Standard power ratings Setting Magnetic Reference Weight of -phase motors range of tripping 50/60 Hz in category AC- thermal current 400/415 V 500 V trips Id ± 20 % P Icu Ics (2) P Icu Ics (2) kw ka kw ka A A kg 0.1 0.16 1.5 GV2-ME01 0.280 GV2-MEpp 0.06 g g 0.16 0.25 2.4 GV2-ME02 0.280 0.09 g g 0.25 0.40 5 GV2-ME0 0.280 0.12 g g 0.40 0.6 8 GV2-ME04 0.280 0.18 g g 0.25 g g 0.7 g g 0.6 1 1 GV2-ME05 0.280 0.7 g g 0.7 g g 0.7 g g 1 1.6 22.5 GV2-ME06 0.280 0.55 g g 0.55 g g 0.75 g g 0.75 g g 1.1 g g 1.6 2.5.5 GV2-ME07 0.280 1.1 g g 1.5 g g 2.5 4 51 GV2-ME08 0.280 1.5 g g 2.2 g g 2.2 g g 50 100 4 6. 78 GV2-ME10 0.280 g g 4 10 100 6 10 18 GV2-ME14 0.280 4 g g 5.5 10 100 5.5 15 50 7.5 6 75 9 14 170 GV2-ME16 0.280 7.5 15 50 9 6 75 1 18 22 GV2-ME20 0.280 9 15 40 11 4 75 17 2 27 GV2-ME21 0.260 11 15 40 11 15 40 15 4 75 20 25 27 GV2-ME22 0.260 Contact blocks Description Mounting Max. Type of contacts Sold in Unit Weight number lots of reference kg Instantaneous Front 1 N/O + N/C 10 GV-AE11 0.00 auxiliary N/O + N/O 10 GV-AE20 0.00 contacts LH 2 N/O + N/C 1 GV-AN11 0.060 side N/O + N/O 1 GV-AN20 0.060 Accessory Description Application Sold in Unit Weight lots of reference kg LA9-D99 Cable end For connection of 20 LA9-D99 reducer () conductors from 1 to 1.5 mm 2 (1) For connection of conductors from 1 to 1.5 mm 2 the use of a cable end reducer LA9-D99 is recommended. (2) As % of Icu. g > 100 ka () 2 supplied with each circuit-breaker as standard. /5 to /7 & /25 to /0 pages /4 to /48 pages /49 to /51 Schneider Electric /

GV2-AK00 GV1-L GV-AX GV2-ME GV-AD GV-AM11 GV-AU GV2-P GV-AM11 GV-AS GV2-L GV-AE11, AE20 GV-AN GV-AN GV-AE1 GV2-LE GV-AE1 /4 Schneider Electric

Thermal-magnetic and magnetic motor circuit-breakers type GV2 with screw clamp terminals Accessories Contact blocks with screw clamp terminals Description Mounting Maximum Type of contacts Sold in Unit Weight number lots of reference kg Instantaneous Front (1) 1 N/O or N/C (2) 10 GV-AE1 0.015 auxiliary N/O + N/C 10 GV-AE11 0.020 contacts N/O + N/O 10 GV-AE20 0.020 Side 2 N/O + N/C 1 GV-AN11 0.050 (LH) N/O + N/O 1 GV-AN20 0.050 Fault signalling Side () 1 N/O + N/O 1 GV-AD1010 0.055 contact + (LH) (fault) + N/C 1 GV-AD1001 0.055 instantaneous N/C + N/O 1 GV-AD0110 0.055 auxiliary contact (fault) + N/C 1 GV-AD0101 0.055 Short-circuit signalling Side 1 C/O 1 GV-AM11 0.045 contact (LH) common point Electric trips with screw clamp terminals Mounting Voltage Reference Weight kg Undervoltage or shunt trips (4) Side 24 V 50 Hz GV-Ap025 0.105 (1 block on RH side 60 Hz GV-Ap026 0.105 of circuit-breaker) 48 V 50 Hz GV-Ap055 0.105 60 Hz GV-Ap056 0.105 100 V 50 Hz GV-Ap107 0.105 100 110 V 60 Hz GV-Ap107 0.105 110 115 V 50 Hz GV-Ap115 0.105 60 Hz GV-Ap116 0.105 120 127 V 50 Hz GV-Ap125 0.105 127 V 60 Hz GV-Ap115 0.105 200 V 50 Hz GV-Ap207 0.105 200 V 220 V 60 Hz GV-Ap207 0.105 220 V 240 V 50 Hz GV-Ap225 0.105 60 Hz GV-Ap226 0.105 80 V 400 V 50 Hz GV-Ap85 0.105 60 Hz GV-Ap86 0.105 415 V 440 V 50 Hz GV-Ap415 0.105 415 V 60 Hz GV-Ap416 0.105 440 V 60 Hz GV-Ap85 0.105 480 V 60 Hz GV-Ap415 0.105 500 V 50 Hz GV-Ap505 0.105 600 V 60 Hz GV-Ap505 0.105 Undervoltage trip, INRS (can only be mounted on GV2-ME) Safety device for dangerous machines, conforming to INRS and VDE 011 Side 110 115 V 50 Hz GV-AX115 0.110 (1 block on RH side 60 Hz GV-AX116 0.110 of circuit-breaker 127 V 60 Hz GV-AX115 0.110 GV2-ME) 220 240 V 50 Hz GV-AX225 0.110 60 Hz GV-AX226 0.110 80 400 V 50 Hz GV-AX85 0.110 60 Hz GV-AX86 0.110 415 440 V 50 Hz GV-AX415 0.110 440 V 60 Hz GV-AX85 0.110 Add-on contact blocks with screw clamp terminals Description Mounting Maximum Reference Weight number kg Visible isolation Front (1) 1 GV2-AK00 0.150 block (5) Limiters At top 1 GV1-L 0.10 (GV2-ME and GV2-P) LA9-LB920 /5 to /7 & /25 to /0 Schneider Electric Independent 1 LA9-LB920 0.20 (1) Mounting of a GV-AE contact block or a GV2-AK00 visible isolation block on GV2-P and GV2-L. (2) Choice of N/C or N/O contact operation, depending on which way round the reversible block is mounted. () The GV-AD is always mounted next to the circuit-breaker. (4) To order an undervoltage trip: replace the dot (p) in the reference with a U, example: GV-AU025. To order a shunt trip: replace the dot (p) in the reference with an S, example: GV-AS025. (5) Visible isolation of the poles upstream of circuit-breaker GV2-P and GV2-L. pages /4 to /48 pages /49 to /51 /5

GV2-G454 GV2-G254 LAD-1 GV1-G09 GV2-G454 LAD-1 GV2-G254 GV1-G10 GV2-G05 LA9-E07 GV2-AF GV2-AF01 GV2-AF4 GK2-AF01 GV2-GA01 GV2-AF02 GV1-G02 GV2-AP0 2 TRIP. RESET GV2-V0 O /6 Schneider Electric

Thermal-magnetic and magnetic motor circuit-breakers type GV2 with screw clamp terminals Accessories Accessories Description Application Sold in Unit Weight lots of reference kg Adapter plate For mounting a GV2-ME 10 GV2-AF02 0.021 or GV2-LE by screw fixing For mounting a GV2-ME or 10 LAD-1 0.040 GV2-P and contactor LC1-D09 to D8 with front faces aligned Height compensation plate 7.5 mm 10 GV1-F0 0.00 Combination block Between GV2 and contactor 10 GV2-AF01 0.020 LC1-K or LP1-K Between GV2 and contactor 10 GV2-AF 0.016 LC1-D09 D8 Between GV2 mounted 10 GV2-AF4 0.016 on LAD-1 and contactor LC1-D09 D8 Motor starter With -pole connection 1 GK2-AF01 0.120 adapter plate for mounting a GV2 and an LC1-D09 to D25 contactor Description Application Pitch Reference Weight mm kg Sets of -pole 2 tap-offs 45 GV2-G245 0.06 6 A busbars 54 GV2-G254 0.08 72 GV2-G272 0.042 tap-offs 45 GV2-G45 0.058 54 GV2-G54 0.060 4 tap-offs 45 GV2-G445 0.077 54 GV2-G454 0.085 72 GV2-G472 0.094 5 tap-offs 54 GV2-G554 0.100 Description Application Sold in Unit Weight lots of reference kg Protective end cover (1) For unused busbar outlets 5 GV1-G10 0.005 Terminal blocks for Connection from the top 1 GV1-G09 0.040 supply to one or more Can be fitted with current limiter 1 GV2-G05 0.115 GV2-G busbar sets GV1-L (GV2-ME and GV2-P) Cover for terminal block For mounting in 10 LA9-E07 0.005 modular panels Flexible -pole connection Centre distance between 10 GV1-G02 0.01 for connecting a GV2 mounting rails: 100 120 mm to an LC1-D09 D25 contactor Set of connections For connecting GV2-ME 10 GV2-GA01 0.045 upstream/downstream to a printed circuit board Clip-in marker holders For GV2-P, GV2-L, GV2-LE 100 LA9-D92 (1) 0.001 (supplied with each and GV2-RT (8 x 22 mm) circuit-breaker) Padlockable external operator Description Reference Weight kg pages /4 to /48 Schneider Electric For GV2-P and GV2-L Padlocking in On and Off position GV2-AP01 0.200 (150 to 290 mm) Black handle, blue legend plate, IP 54 Padlocking in Off position GV2-AP02 0.200 Red handle, yellow legend plate, IP 54 For GV2-LE Padlocking in On and Off position GV2-AP0 0.280 Black handle, blue legend plate, IP 54 Padlocking device For all GV2 devices For use with up to 6 padlocks (not supplied), GV2-V0 0.10 Ø 6 mm shank max. (1) Check with requirements of local Isolation standards before use. /7

GV2-MC GV2-V01 GV2-K04 GV2-MP GV2-K011 GV2-E01 GV2-CP GV2-SN /8 Schneider Electric

Enclosed thermal-magnetic motor circuit-breakers type GV2-ME and accessories, assembled by user Enclosed thermal-magnetic motor circuit-breakers GV2-ME Thermal-magnetic motor circuit-breakers and accessories: see pages /1 and /. The motor starter comprising an enclosed motor circuit-breaker GV2-ME conforms to IEC/EN 60947-4-1. GV2- ME01 ME02 ME0 ME04 ME05 ME06 ME07 ME08 ME10 ME14 ME16 ME20 ME21 ME22 Ithe (A) 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6. 9 1 17 21 2 Enclosures for thermal-magnetic motor circuit-breakers GV2-ME Type Degree of protection Possible attachments Reference Weight on side of GV2-ME Left Right kg Surface IP 41 1 1 GV2-MC01 0.290 mounting Double, insulated with IP 55 1 1 GV2-MC02 0.00 protective or GV2-MCK04 (1) 0.420 conductor. Sealable IP 55 for 1 1 GV2-MC0 0.00 cover temperature < + 5 C Flush, IP 41 (front face) 1 1 GV2-MP01 0.115 mounting IP 41 (reduced flush mounting) 1 GV2-MP0 0.115 with protective IP 55 (front face) 1 1 GV2-MP02 0.10 conductor IP 55 (reduced flush mounting) 1 GV2-MP04 0.10 Front plate For direct control, through a panel IP 55 GV2-CP21 0.800 of a chassis-mounted GV2-ME Accessories common to all enclosures (to be ordered separately) Description Sold in Unit Weight lots of reference kg Padlocking device (2) 1 to padlocks 1 GV2-V01 0.075 for GV2-ME operator (padlocking is only Ø 4 to 8 mm possible in O position) Mushroom Spring return (2) 1 GV2-K011 0.052 head Stop Latching (2) Key release 1 GV2-K021 0.160 pushbutton IP 55 key n 455 Ø 40 mm, red Turn to 1 GV2-K01 0.115 release 1 GV2-K04 () 0.120 Sealing kit For enclosures IP 55 10 GV2-E01 0.012 and front plate IP 55 for θ < + 5 C 10 GV2-E02 0.012 Neutral terminal 100 AB1-VV65UBL 0.015 Partition 50 AB1-AC6BL 0.00 Description Voltage Colour Sold in Unit Weight V lots of reference kg Neon 110 Green 10 GV2-SN1 0.019 indicator Red 10 GV2-SN14 0.019 light Orange 10 GV2-SN15 0.019 Clear 10 GV2-SN17 0.019 220/240 Green 10 GV2-SN2 0.019 Red 10 GV2-SN24 0,019 Orange 10 GV2-SN25 0,019 Clear 10 GV2-SN27 0,019 80/440 Green 10 GV2-SN 0.019 Red 10 GV2-SN4 0.019 Orange 10 GV2-SN5 0.019 Clear 10 GV2-SN7 0.019 (1) The GV2-MCK04 enclosure has a GV2-K04 mushroom head Stop pushbutton fitted as standard. (2) Supplied with IP 55 sealing kit. For use with GV2-Mp01. () Padlockable in Off position using Ø 4 to 8 mm shank padlocks. Schneider Electric /9

Magnetic motor circuit-breakers types GV2-L and GV2-LE Magnetic circuit-breakers GV2-L with screw clamp terminals GV2-L Rotary handle Standard power ratings Magnetic Trip- Use in Reference Weigh t of -phase motors protection ping association 50/60 Hz in category AC- rating current with 400/415 V 500 V 690 V Id ± 20 % thermal P Icu Ics P Icu Ics P Icu Ics overload (1) (1) (1) relay kw ka kw ka kw ka A A kg 0.09 g g 0.4 5 LRD-0 GV2-L0 0.0 0.12 g g 0.7 g g 0.6 8 LRD-04 GV2-L04 0.0 0.18 g g 0.6 8 LRD-04 GV2-L04 0.0 0.55 g g 1 1 LRD-05 GV2-L05 0.0 0.25 g g 1 1 LRD-05 GV2-L05 0.0 0.75 g g 1 1 LRD-06 GV2-L05 0.0 0.7 g g 0.7 g g 1 1 LRD-05 GV2-L05 0.0 0.55 g g 0.55 LRD-06 GV2-L06 0.0 0.75 g g 1.6 22.5 LRD-06 GV2-L06 0.0 0.75 g g 1.1 g g 1.5 4 100 2.5.5 LRD-07 GV2-L07 0.0 1.1 g g 2.5.5 LRD-08 GV2-L08 0.0 1.5 g g 1.5 g g 4 100 51 LRD-08 GV2-L08 0.0 2.2 g g 4 51 LRD-08 GV2-L08 0.0 2.2 g g g g 4 4 100 6. 78 LRD-10 GV2-L10 0.0 g g 4 10 100 5.5 4 100 10 18 LRD-12 GV2-L14 0.0 4 g g 5.5 10 100 10 18 LRD-14 GV2-L14 0.0 7.5 4 100 10 18 LRD-14 GV2-L14 0.0 9 4 100 14 170 LRD-16 GV2-L16 0.0 5.5 50 50 7.5 10 75 11 4 100 14 170 LRD-16 GV2-L16 0.0 7.5 50 50 9 10 75 15 4 100 18 22 LRD-21 GV2-L20 0.0 9 50 50 11 10 75 18.5 4 100 25 27 LRD-22 GV2-L22 0.0 11 50 50 15 10 75 25 27 LRD-22 GV2-L22 0.0 15 50 50 18.5 10 75 22 4 100 2 416 LRD-2 GV2-L2 0.0 (1) As % of Icu. g > 100 ka. /5 to /7 & /25 to /0 pages /4 to /48 pages /49 to /51 /40 Schneider Electric

Magnetic motor circuit-breakers types GV2-L and GV2-LE Magnetic circuit-breakers GV2-LE with screw clamp terminals GV2-LE Rocker lever Standard power ratings Magnetic Trip- Use in Reference Weigh t of -phase motors protection ping association 50/60 Hz in category AC- rating current with 400/415 V 500 V 690 V Id ± 20 % thermal P Icu Ics P Icu Ics P Icu Ics overload (1) (1) (1) relay kw ka kw ka kw ka A A kg 0.06 g g 0.4 5 LR2-K002 GV2-LE0 0.0 0.09 g g 0.4 5 LR2-K004 GV2-LE0 0.0 0.12 g g 0.7 g g 0.6 8 LR2-K004 GV2-LE04 0.0 0.18 g g 0.6 8 LR2-K005 GV2-LE04 0.0 0.55 g g 1 1 LR2-K005 GV2-LE05 0.0 0.25 g g 1 1 LR2-K006 GV2-LE05 0.0 0.75 g g 1 1 LR2-K006 GV2-LE05 0.0 0.7 g g 0.7 g g 1 1 LR2-K006 GV2-LE05 0.0 0.55 g g 0.55 g g 1.1 g g 1.6 22.5 LR2-K007 GV2-LE06 0.0 0.75 g g 1.6 22.5 LR2-K007 GV2-LE06 0.0 0.75 g g 1.1 g g 1.5 75 2.5.5 LR2-K008 GV2-LE07 0.0 1.1 g g 2.5.5 LR2-K008 GV2-LE08 0.0 1.5 g g 1.5 g g 75 4 51 LR2-K010 GV2-LE08 0.0 2.2 g g 4 51 LR2-K012 GV2-LE08 0.0 2.2 g g 50 100 4 75 6. 78 LR2-K012 GV2-LE10 0.0 g g 4 10 100 5.5 75 10 18 LR2-K014 GV2-LE14 0.0 4 g g 5.5 10 100 10 18 LR2-K016 GV2-LE14 0.0 7.5 75 10 18 LRD-14 GV2-LE14 0.0 9 75 14 170 LRD-16 GV2-LE16 0.0 5.5 15 50 7.5 6 75 11 75 14 170 LR2-K021 GV2-LE16 0.0 7.5 15 50 9 6 75 15 75 18 22 LRD-21 GV2-LE20 0.0 9 15 40 11 4 75 18.5 75 25 27 LRD-22 GV2-LE22 0.0 11 15 40 15 4 75 25 27 LRD-22 GV2-LE22 0.0 15 10 50 18.5 4 75 22 75 2 416 LRD-2 GV2-LE2 0.0 (1) As % of Icu. TeSys protection components g > 100 ka. /5 to /7 & /25 to /0 pages /4 to /48 pages /49 to /51 Schneider Electric /41

Thermal magnetic circuit-breakers type GV2-RT (1) For motors with high current peak on starting GV2-RT Control by rocker lever Standard power ratings Setting Magnetic Reference Weight of -phase motors range of tripping 50/60 Hz in category AC- thermal current 220 400 trips Id ± 20 % 20 V 415 V 440 V 500 V 690 V kw kw kw kw kw A A kg 0.06 0.09 0.09 0.25 0.40 8 GV2-RT0 0.50 0.12 0.12 0.18 0.18 0.7 0.40 0.6 1 GV2-RT04 0.50 0.09 0.25 0.25 0.12 0.7 0.7 0.7 0.55 0.6 1 22 GV2-RT05 0.50 0.18 0.7 0.7 0.7 0.75 0.25 0.55 0.55 0.55 1.1 1 1.6 GV2-RT06 0.50 0.75 0.75 0.7 0.75 1.1 1.1 1.5 1.6 2.5 51 GV2-RT07 0.50 0.55 1.1 1.5 2.2 0.75 1.5 1.5 2.2 2.5 4 78 GV2-RT08 0.50 2.2 1.1 2.2 4 4 6. 18 GV2-RT10 0.50 1.5 4 5.5 2.2 4 4 5.5 7.5 6 10 200 GV2-RT14 0.50 2.2 5.5 9 5.5 7.5 7.5 11 9 14 280 GV2-RT16 0.50 7.5 4 7.5 9 9 15 1 18 400 GV2-RT20 0.50 9 5.5 11 11 11 18.5 17 2 400 GV2-RT21 0.50 For primaries of -phase transformers Control by rocker lever Standard power ratings Setting range Magnetic Reference Weight 20 400 of thermal tripping current 240 V 415 V 440 V 500 V 690 V trips Id ± 20 % kva kva kva kva kva A A kg 0.25 0.40 8 GV2-RT0 0.50 0.40 0.6 1 GV2-RT04 0.50 0.6 0.6 1 0.6 1 22 GV2-RT05 0.50 0.4 0.6 1 1 1 1.6 GV2-RT06 0.50 1.6 0.6 1 1.6 2 1.6 2.5 51 GV2-RT07 0.50 1.6 1.6 2 1 2 2 2.5 2.5 2.5 4 78 GV2-RT08 0.50 1.6 2.5 4 2 2.5 4 4 5 4 6. 18 GV2-RT10 0.50 6. 4 5 2.5 5 5 6. 6 10 200 GV2-RT14 0.50 10 4 6. 6. 12.5 9 14 280 GV2-RT16 0.50 5 10 6. 10 10 12.5 10 1 18 400 GV2-RT20 0.50 Accessory (2) Description Reference Weight kg Padlockable external operator (IP 54), GV2-AP0 0.280 black handle, blue legend plate (1) Characteristics of GV2-RT identical to those of GV2-ME except for tripping current (id). (2) Other accessories such as mounting, cabling and marking accessories are identical to those used for GV2-ME motor circuit-breakers, see page /9. /5 to /7 & /25 to /0 pages /4 to /48 pages /49 to /51 /42 Schneider Electric