DMX-LED-DIMMER X9 HR 9x 16 BIT PWM per 10A

Similar documents
DMX-LED-DIMMER X9 HR 9x 16 BIT PWM per 10A

DMX-Universaldemux. 8 outputs with different operation modes Treshold / Binary / PWM / Strobe / Servo. User Manual

DMX Relais/Analog Interface 4. User Manual

DMX-LED-DIMMER S. User Manual

ArtNet-LED-Dimmer 6 ArtNet-LED-Dimmer 6R

DMX-Splitter 4. User Manual

LIGHT REMOTE. for Android

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

OPERATING MANUAL. DMX LED Current Dimmer 5004A-EP Mk2

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

GMB101R BLACK BURST & PATTERN GENERATOR GMB101R-M 09/06/08

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Siteco Service Box User Manual 1/31

120cm (4x36 Watt) incl. Splitter Instruction Manual

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

Operating Instructions

TM Load-regulated locomotive decoder

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

15 Series - Dimmer

GV 460 / GV 461 Impulse Splitters for Incremental Encoders with Potential Separation between Input and Outputs

VS-201H VS-401H VS-801H

Gamma instabus. Technical product information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

TVAC20000 User manual

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

User Manual MODEL: KKW700V. Non-Touch True Display LCD Monitor. Installation Guide. 7 True Display LCD Monitor (VGA Interface)

LINE DRIVERS MANUAL PART NUMBER: DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

CP-259HN HDMI to HDMI Scaler

Absolute Encoders Multiturn

TPW300series. CAT5/6 RGBHsVs TRANSCEIVERS

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

DCP100 Digital Control Programmer Specifications

Table of Contents FCC COMPLIANCE STATEMENT... 4 WARNINGS AND PRECAUTIONS... 4 WARRANTY... 5 STANDARD WARRANTY... 5 TWO YEAR WARRANTY... 5 DISPOSAL...

LINE DRIVERS MANUAL PART NUMBER: DA2000TM 1-IN, 1-OUT TABLE MOUNT COMPUTER VIDEO + AUDIO LINE DRIVER USER S GUIDE

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

LED IP65 Slimline Par RGBWA +UV 7x12W

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

3G/HD/SD-SDI to HDMI Converter

Led Dynamic DMX Tri Curtain Manual

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Figure 1: Device components

PRINCIPLES AND APPLICATIONS

LT-300 LED Controller

Dimming actuators GDA-4K KNX GDA-8K KNX

Disclaimer of Product & Services The information offered in this instruction manual is intended as a guide only. At all times, Datavideo Technologies

DISTRIBUTION AMPLIFIER

KHT 1000C HV-Probe Calibrator. Instruction Manual

RENFE TAF / CP FOGUETE References: & 47023

LED MODULES READYLINE DL

Professional Fidelity Mastering Grade Listening

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

VarTech Systems Inc.

R&S ZN-Z154 Calibration Unit Specifications

DA1931CT/ TP to Video + Audio Receiver

QolorFLEX 4x2.5A Dimmer User s Manual Rev 0.18

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

KNX Dimmer RGBW - User Manual

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Multi-Zone Programmable RGB ColorPlus LED Touch Controller (Remote Control) and RGB ColorPlus LED Touch Controller (Receiver)

Camera 220C Document Camera User s Guide

AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T

User Manual rev: Made in Taiwan

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

1440/2880 HP RGB+WW+CW

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

High performance circuit breakers

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

Product Specifications

Transvue HDMI 4K2K Scaler

PR FESSIONAL PROFESSIONAL TERRESTICAL FM-FM PTFF Grundig SAT Systems

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

DA VGA Line Receiver User s Guide

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

System Power Supply 4. User Guide

Shutter BladeFader. Functional description Shutter BlackFader V1.0

MICROMASTER Encoder Module

Phono Amplifier brinkmann «EDISON» Manual.

Programmable Micro Remote LED Controller for RGB LED Strips - 12 or 24 VDC Part number: PMRC

Gordian. Multifunctional Power Distributor / Conditioner. v1.3

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Transcription:

DMX-LED-DIMMER X9 HR 9x 16 BIT PWM per 10A User Manual

DMX-LED-Dimmer X9 HR 2 Description The DMX-LED-Dimmer X9 HR is especially designed for controlling RGB LED- Stripes. The dimmer has 9 High-Resolution PWM-Outputs (3xRGB) independently controllable via DMX. A global master dimmer (all outputs) or a master dimmer per RGB-Group can be activated. The global master dimmer can be determined permanent as System- Master Dimmer to DMX-Address 1. + POWER PWM DMX DMX RISC CONTROLLER PWM PWM Energy Saving Design: By modern switch mode technology less heat will be generated and thus the energy consumption will be reduced. Technical Data Power supply: 7-24V DC / 100mA without load LED voltage: 7-24V DC (no AC voltage!) DMX: DMX-Fail: Output: Output current: Output power: PWM-frequency: Dimensions: 9 channels with 8Bit-controlling and LookUp-Table 18 channels with 16Bit-controlling + Optional Master-Dimmer-Channels Hold / Off / On 9 PWM-signal with 16Bit-resolution Common supply voltage max. 10A each output, In sum 90A with all connections (direct from PSU) 9x 120W (12V) / 9x 240W (24V) 244 Hz / 2kHz / 4kHz 99 x 82 mm

Connection with one power supply DMX-LED-Dimmer X9 HR 3 DMX IN DMX OUT POWER 12V CFG ADDRESS V+ V+ DMX-LED-Dimmer X9HR OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 DMX+ DMX- RGB-LED-Stripe (12V) RGB-LED-Stripe (12V) RGB-LED-Stripe (12V) Must be connected direct from the power supply. Depends on the current for the LED-Stripes.

DMX-LED-Dimmer X9 HR 4 Connection with several power supplies DMX IN DMX OUT POWER 12V CFG ADDRESS V+ V+ DMX-LED-Dimmer X9HR OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 DMX+ DMX- POWER 12V RGB-LED-Stripe (12V) POWER 24V RGB-LED-Stripe (24V) POWER 12V RGB-LED-Stripe (12V) Must be connected direct from the power supply. Depends on the current for the LED-Stripes.

DMX-LED-Dimmer X9 HR 5 Connection with single color and multi color stripes DMX IN DMX OUT POWER 12V CFG ADDRESS V+ V+ DMX-LED-Dimmer X9HR OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 DMX+ DMX- RGB-LED-Stripe (12V) LED-Stripe WEIß (12V) LED-Stripe WEIß (12V) Must be connected direct from the power supply. Depends on the current for the LED-Stripes.

DMX-LED-Dimmer X9 HR 6 DMX-Addressing The starting address is adjustable with the switches 1 to up 9. Switch 1 has the valecy 2 0 (=1), switch 2 the valency 2 1 (=2) etc. until switch 9 has the valency 2 8 (=256). In total the switches showing ON correlate with the starting address. 1 2 4 8 16 32 64 128 256 OFF LED-Display-Codes The integrated LED is a multifunctional-display. During the normal DMX-Operation the LED flashes permanent. In this case the device is working. Furthermore the LED shows the event. In this case the LED lights in short pitches and then turns into the off mode for a longer period. The number of flashing impulses corresponds with the error status: Error Error Description Status 1 No DMX There is no DMX-Signal reaching the dimmer 2 Address error Check if a valid DMX starting address is adjusted at the DIP-switch 3 DMX-signal error An invalid DMX input signal is detected, invert the signal line by changing switch 2 and 3 or use a twisted pair wire.

DMX-LED-Dimmer X9 HR 7 DMX-Fail Option from 06/2013 (Version 2) The DMX-LED-Dimmer X9 can hold the last value, switch on or switch off the LED outputs on DMX fail. This DMX-Fail option is selectable with the Jumper. Setting the operation mode The DMX-LED-Dimmer X9 HR has 2 operation modes adjustable via the configuration switch 4: Switch 4 OFF: Controlling the outputs via one DMX-channel In this operation mode each output has a LookUp-Table. This displays the outputs 16Bit-resolution for the available 256 values of the DMX-channels. The LookUp-Tables are linear programmable ex ante and freely programmable. Switch 4 ON: Controlling the outputs via two DMX-channels Each output has a 16Bit resolution. For a direct calling via DMX, 2 DMXchannels are used per output. The 2 DMX-Channels are for the subtle settings.

Configurating the LookUp-Table DMX-LED-Dimmer X9 HR 8 The DMX-LED-Dimmer X9 HR has one LookUp-Table per output. The received DMX-Channel has values from 0 up to 255. However the DMX-LED-Dimmer X9 HR output driver provides 65536 steps (16 Bit) which will be assigned to the DMX-values. So it s possible to effect with small steps little brightness changings in the lower brightness range. However in the upper brightness range it s possible to program bigger steps. To transfer the Look-Up Table to the DMX-LED-Dimmer X9 HR a PC- Connection cable and a USB-Connection at the PC is necessary. As of Version 2.2 (Delivery as of 2017) You need a Standard USB-Mini-B Connection cable. Plug the cable to the DMX-LED-Dimmer X9HRs USB-Connection as shown in the picture rightward. By Version 2.1 You need the optional available DMX-LED-Dimmer USB- Configuration cable. Plug the cable to the DMX-LED- Dimmer X9HRs PC-CTRL-Connection as shown in the picture rightward.

DMX-LED-Dimmer X9 HR 9 To define the LookUp-Table please use the program DMX-LED-Dimmer PC- Control from V2.1. each output has an own table with the DMX-values from 0-255 and the corresponding output values. A graphically presentation of the table represents the output characteristics: - Connect the DMX-LED-Dimmer X9HR to the PC as described before - Start the Software DMX-LED-Dimmer PC-Control (V2.1 or higher is needed) - Configure the output characteristic - Select Write to transfer the table for the displayed output.

DMX-Master-Dimmer DMX-LED-Dimmer X9 HR 10 The DMX-LED-Dimmer X9 HR has several Master Dimmer. These will be activated as follows: No Master Dimmer Master Dimmer for all channels Master Dimmer per RGB-group System Master Dimmer for all channels Master Dimmer for all channels The DMX-Channel which is adjusted as starting address will be used as master dimmer for all 9 outputs. The DMX-addresses assignment is as follows: Starting address Starting address Master OUT 1 (R1) OUT 2 (G1) OUT 3 (B1) OUT 4 (R2) OUT 9 (B4) Master OUT 1 (R1) OUT 1 (fine) OUT 2 (G1) OUT 2 (fine) OUT 3 (B1) OUT 3 (fine) OUT 4 (R2) OUT 4 (fine) OUT 9 (B4) OUT 9 (fine) Master Dimmer per RGB-group Per RGB-Group one master dimmer is used. The DMX-Addresses assignment is as follows: Starting Address Starting Address Master 1 OUT 1 (R1) OUT 2 (G1) OUT 3 (B1) Master 2 OUT 4 (R2) OUT 9 (B4) Master 1 OUT 1 (R1) OUT 1 (fine) OUT 2 (G1) OUT 2 (fine) OUT 3 (B1) OUT 3 (fine) Master 2 OUT 4 (R2) OUT 4 (fine) OUT 9 (B4) OUT 9 (fine) System-Master Dimmer for all channels The value for the master dimmer corresponds with the DMX-Channel 1 used as Master Dimmer for all 9 outputs. The DMX-Starting Address represents the DMX- Channel on which the DMX-Values for the outputs begin. The DMX-Addresses assignment is as follows: Channel 1 Starting Address Channel 1 Starting Address Master OUT 1 (R1) OUT 2 (G1) OUT 3 (B1) OUT 4 (R2) OUT 9 (B4) Master OUT 1 (R1) OUT 1 (fine) OUT 2 (G1) OUT 2 (fine) OUT 3 (B1) OUT 3 (fine) OUT 4 (R2) OUT 4 (fine) OUT 9 (B4) OUT 9 (fine)

High Frequency Mode (from FW V1.1) DMX-LED-Dimmer X9 HR 11 The DMX-LED-Dimmer X9 HR has a High Frequency Mode. This mode is optimized for using in correlation with video recording e.g. in the TV-studio. This will be activated as follows: High Frequency Mode 2kHz High Frequency Mode 4kHz In this mode a DMX-Channel (256 steps) will be used for the brightness settings. The master dimmer options are combinable. In this mode is a fixed LookUp-Table used which can t be changed. Software-Reset A RESET of the DMX-LED-Dimmer X9 HR LookUp-Tables into the delivery status is possible by switching switch 1 to 10 on ON and subsequently turn on the power supply. During the reset the error number 4 is shown. This can take some time and should not be interrupted.

DMX-LED-Dimmer X9 HR 12 Equipment DIN-Rail housing 1050 USB-Kabel A Mini B 5pol.

DMX-LED-Dimmer X9 HR 13 CE-conformity This assembly (board) is controlled by a microprocessor and uses high frequency (8MHz). To get the characteristics of the assembly in relation to the CE-conformity, an installation in a compact metal casing is necessary. Risk-Notes You purchased a technical product. Conformable to the best available technology the following risks should not excluded: Failure risk: The device can drop out partially or completely at any time without warning. To reduce the probability of a failure a redundant system structure is necessary. Initiation risk: For the installation of the board, the board must be connected and adjusted to foreign components according to the device paperwork. This work can only be done by qualified personnel, which read the full device paperwork and understand it. Operating risk: The Change or the operation under special conditions of the installed systems/components could as well as hidden defects cause to breakdown within the running time. Misusage risk: Any nonstandard use could cause incalculable risks and is not allowed. Warning: It is not allowed to use the device in an operation, where the safety of persons depend on this device.

DMX4ALL GmbH Reiterweg 2A D-44869 Bochum Germany Last changes : 25.09.2017 Copyright DMX4ALL GmbH All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another procedure) without written permission or processed, multiplied or spread using electronic systems. All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless errors are to be excluded not completely. For this reason I see myself compelled to point out that I can take over neither a warranty nor the legal responsibility or any adhesion for consequences, which decrease/go back to incorrect data. This document does not contain assured characteristics. The guidance and the characteristics can be changed at any time and without previous announcement.