PKT 512A-RO. High impedance passive cable divider. Features: BNC to BNC connection. 500 MHz system bandwidth. Double HF adjustment

Similar documents
PKT 512A-RO. High impedance passive cable divider. Features: BNC to BNC Connection. 500 MHz System Bandwidth. Double HF Adjustment

KHT 1000C HV-Probe Calibrator. Instruction Manual

R&S RT-Zxx High-Voltage and Current Probes Specifications

Instructions. P MHz 1X/10X Passive Probe

R&S RT-Zxx Standard Probes Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

Supplement. TDS1000 and TDS2000 Series User Manual Specifications Update

NI PXI/PXIe-2543 Specifications

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

PAM-1840 Preamplifier Operation Manual

Tablet Oscilloscope Quick Guide

USB Contents. Definitions SPECIFICATIONS. RF Power Sensor Device

Fluke 279 FC True-rms Thermal Multimeter

Connect 350 UHD. Connect 350 UHD USER MANUAL 3 GEBRAUCHSANLEITUNG GUIDE UTILISATEUR MODO DE EMPLEO MANUALE D ISTRUZIONI GEBRUIKSAANWIJZING

PicoScope 2000 Series PC Oscilloscopes

ScopeMeter 190 Series Specifications

E15X-SUB Manual (1.2 EN)

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

NECT 540 U CONNECT 540 UHD USER MANUAL 3 GEBRAUCHSANLEITUNG GUIDE UTILISATEUR MODO DE EMPLEO MANUALE D ISTRUZIONI GEBRUIKSAANWIJZING

PicoScope 6407 Digitizer

MILLITARY SPECIFICATION SHEET

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

WVR500 Waveform/Vector Monitor

PSC UHF Log Periodic Antenna

3M Sensored Termination (15 kv) QX-T15I-vi1-E

MAP110 AC-DC Series Data Sheet

USER MANUAL. VM-10xl Video Audio Distribution Amplifier MODEL: P/N: Rev 4

USER GUIDE MULTI-CHANNEL STEREO MIXER S MIX 4M2S UD

Specifications. Reference Documentation. Performance Conditions

NS-3 RF Noise Source Operation Manual

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

PicoScope 5000D Series

R&S FPC-Z10 Teaching Kit Getting Started

SK2002DA SIDEKICKER 1-IN, 2-OUT VGA-UXGA DISTRIBUTION AMPLIFIER CABLE USER S GUIDE DISTRIBUTION AMPLIFIERS

DAC-AES. DAC-AES Audio Converter. User manual. Rev. 7

Data Pattern Generator

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Topology 1-wire 16 Bank 8 1, 1-wire Octal 16 1, 1-wire Quad 32 1, 1-wire Dual 64 1, 1-wire 128 1

Thermocouple and RTD Modules for Compact FieldPoint

This document lists specifications for the PXI-5691 RF amplifier.

Surface Mount Multilayer Ceramic Chip Capacitors for High Frequency

PicoScope 3000 Series Automotive User guide

User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

02/11/2015

PicoScope 6407 Digitizer

Tube Roller Shakers. User Guide. Version 1.2

PicoScope 4000 Automotive PC Oscilloscopes

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

DA-12R. User Manual. 1 to 2 RGBHV Distribution Amplifier. rev (English) COMM-TEC GmbH Siemensstr. 14 D Uhingen

USER MANUAL. 101L Video Line Amplifier MODEL: P/N: Rev 2

Tube Rotator. User Guide. Version 1.2

KRF EMC Filters Installation, Operation and Maintenance Manual

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

TA2000B-x GHz Fast Pulse / Timing Preamplifier User Manual

28 II Ex Digital Multimeter

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

2016 RIGOL TECHNOLOGIES, INC.

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

SAFETY TERMS AND SYMBOLS

PicoScope 4000 Series PC Oscilloscopes

Multi-Channel Passive Transceiver Hubs Installation Sheet

3B SCIENTIFIC PHYSICS

PicoScope 4000 Series PC Oscilloscopes

Users Manual. Stroboscope. September 2014

Jul03 Rev C EC

AMERICAN NATIONAL STANDARD

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.

ProcessMeter. Product Overview

USER MANUAL. PT-102VN 1:2 Video DA MODEL: P/N: Rev 2

Display Information Type Backlit blue on white STN Type

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

Quality products from a single source

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

R&S RT-ZF5 Ethernet Probing Fixture Manual

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

S MiX 2M2S UF. S MiX 2M2S F

PT-C-HDADE. User Manual. HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model PT-C-HDADE. Designed in Germany

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

Operation Manual for. SCU1 Signal Conditioning Unit

HulaMixer Sample Mixer

E3/DS3 Fibre Extender

1587 FC/1587/1577. Calibration Manual. Insulation Multimeters

Achat 115 Sub A active subwoofer. user manual

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

MKE 2 Gold. Instruction manual

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DISTRIBUTION AMPLIFIER

VPS1 Installation Manual

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

DSP 18 Sub active subwoofer. user manual

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

INNOVATION IN MAGNETICS DS3434/5. Mag612. Miniature Three-Axis Fluxgate Probe.

Model P2016. Dual Channel Handheld Digital Storage. Oscilloscope & Multimeter. Quick Scope Guide

Transcription:

High impedance passive cable divider Features: BNC to BNC connection 500 MHz system bandwidth Double HF adjustment For permanent installation in applications on vibrating equipment like machines and engines The PKT 512A-RO is a 10:1 cable divider designed for instruments having 1 MΩ input resistance. The cable divider is rated 300 V rms CAT II and complies with the latest safety standards of the Low Voltage Directive (LVD) and is category 9 within the WEEE/RoHS directives of the EC. See page 4 for further explanation. A typical use for the PKT512A-RO is an installation in applications on vibrating equipment like machines and engines, where a connection is made from BNC to BNC. System bandwidth is 500 MHz with a typical risetime of 700 ps. The PKT 512A-RO is HF adjustable and offers a compensation range from 7 pf to 25 pf. With an operating temperature range from 0 C to +50 C and the availability of different cable length and sufficient protection to it like the optional silicon cable insulation and reinforced steel strain relief, it meets the requirements of a variety of measuring applications. Thank you for your interest in our product! 1

This datasheet supersedes all previously published material. Specifications that are defined typical are not guaranteed and are published as general information to the user. The instrument should have warmed up for at least 20 minutes and the environmental conditions must not exceed the specified limits of the probe. Note that specifications are subject to change without notice. Electrical specifications Attenuation ratio (1) 10:1 ± 2 % at DC Voltage coefficient 0.0025 % / V (typical) System bandwidth 500 MHz (-3 db) System risetime 700 ps (10% 90 %) (typical) Maximum rated input voltage Measurement category I: 400 V rms 1250 V transient overvoltage Measurement category II: 300 V rms CAT II Pollution degree 2 Voltage derating Typical voltage derating PKT512A-RO Measurement Category I Amplitude AC rms [V]Sinus 400 300 200 100 Note that the max. input voltage rating of the cable divider decreases as the frequency of the applied signal increases. 0 10K 100K 10M 100M 1G Frequency [Hz] (1) Connect to oscilloscope with an input impedance of 1 MΩ ± 1 %. 2

Electrical characteristics Input resistance (system) 10 MΩ ± 1 % Input capacitance (system) 10 pf (typical) Compensation range 7 pf 25 pf (typical) Input coupling of the measuring instrument 1 MΩ AC / DC Input impedance 100M 10M Typical input impedance PKT512A-RO Z [Ohm] 1M 100K 10K 1K 100 10 10 100 1K 10K 100K 1M 10M 100M 1G Frequency [Hz] Note that the input impedance of the cable divider decreases as the frequency of the applied signal increases. Mechanical characteristics Weight (cable divider only) Cable Length Connection to Signal 58 g 1.2 m BNC 3

Environmental specifications Altitude operating up to 2000 m non-operating up to 15000 m Temperature range operating 0 C to +50 C non-operating -40 C to +71 C Maximum relative humidity operating 80% relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C Declaration of conformity The manufacturer declares the conformity of his products with the actual required safety standards in accordance with the Low Voltage Directive (LVD) 2006/95/EC: CEI/IEC 61010-031:2002 Safety requirements for electrical equipment for measurement, control and laboratory use. Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test. WEEE/ RoHS directives PMK electronic products are classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempt from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return any electronic product at the end of its life either to the manufacturer or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste! * EC Directives: WEEE Directive 2002/96/EC Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 4

Scope of delivery PKT 512A-RO Order No. 858-512-A01 Adjustment Tool T Coding rings (set) 3 x 4 colors Instruction manual PKT Cable Divider options: (not included in standard scope of delivery) silicon cable insulation reinforced steel strain relief Safety information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the safety informations stated in the manual before using this product. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this cable divider. Manufacturer PMK GmbH Mess- und Kommunikationstechnik Industriestr. 17 63150 Heusenstamm, Germany Phone: +49 (0) 6104 6453 Fax: +49 (0) 6104 6457 Internet: www.pmk.de E-Mail: sales@pmk.de service@pmk.de Revision A August 2009 5