Introducing Purion H, a Scanned Spot Beam High Current Ion Implanter

Similar documents
August 4, Axcelis Technologies, Inc.

Ion Beam Technologies for the 20nm Technology Node, 450mm Wafer Processes, and Beyond Jiong Chen, Junhua Hong, Jin Zhang, and Jeff Boeker

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Uniformity Improvement of the Ion Implantation System for Low Temperature Poly-Silicon TFTs

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Recent APS Storage Ring Instrumentation Developments. Glenn Decker Advanced Photon Source Beam Diagnostics March 1, 2010

Semiconductors Displays Semiconductor Manufacturing and Inspection Equipment Scientific Instruments

Hall-B Beamline Commissioning Plan for CLAS12

Principles of Electrostatic Chucks 6 Rf Chuck Edge Design

Mechanical aspects, FEA validation and geometry optimization

Approved by: / / R. Battaglia 12/16/2016

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

(12) United States Patent

Physics Requirements for the CXI Ion Time-of-Flight

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

EPJ Web of Conferences 95,

PHI 5000 VersaProbe TM Operator s Guide

Etching Part 2. Saroj Kumar Patra. TFE4180 Semiconductor Manufacturing Technology. Norwegian University of Science and Technology ( NTNU )

These are used for producing a narrow and sharply focus beam of electrons.

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

Operation of CEBAF photoguns at average beam current > 1 ma

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Beam Commissioning of GRIFFIN Beam Line

Cyclotron Institute upgrade project. H. L. Clark, F. Abegglen, G. Chubarian, G. Derrig, G. Kim, D. May, B. Roeder and G. Tabacaru

HIGH CURRENT IMPLANTER 200KeV - SERIES 1090 TECHNICAL DESCRIPTION

A New 4MW LHCD System for EAST

In-process inspection: Inspector technology and concept

HIGH POWER BEAM DUMP AND TARGET / ACCELERATOR INTERFACE PROCEDURES *

vacuum analysis surface science plasma diagnostics gas analysis

Universal High Current Implanter for Surface Modifications with ion beams Extensive range of ion species, including refractory metals Magnetic mass

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Standard Operating Manual

Digital BPMs and Orbit Feedback Systems

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

UV Nanoimprint Tool and Process Technology. S.V. Sreenivasan December 13 th, 2007

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

Advanced Photon Source - Upgrades and Improvements

Linac 4 Instrumentation K.Hanke CERN

(12) Patent Application Publication (10) Pub. No.: US 2006/ A1

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

III. Proton-therapytherapy. Rome SB - 3/5 1

Service. Nu Instruments Service & Upgrades. ICP-MS, GD-MS, IRMS, Noble Gas.

APPLICATIONS OF DIGITAL IMAGE ENHANCEMENT TECHNIQUES FOR IMPROVED

PBS Products from Pyramid

Elements of a Television System

The Elettra Storage Ring and Top-Up Operation

A Facility for Accelerator Physics and Test Beam Experiments

1. General principles for injection of beam into the LHC

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

STATUS OF THE SwissFEL C-BAND LINAC

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

Program to improve the ion beam formation and transmission at JYFL

The PEFP 20-MeV Proton Linear Accelerator

2.2. VIDEO DISPLAY DEVICES

SC26 Magnetic Field Cancelling System

Limitations of a Load Pull System

Lt DELTA USA, Inc

INSTALLATION STATUS OF THE ELECTRON BEAM PROFILER FOR THE FERMILAB MAIN INJECTOR*

Large-Scale Polysilicon Surface Micro-Machined Spatial Light Modulator

Introduction of Medium Current Ion Implanter EXCEED3000AH-8C -New 200mm Tool-

CONTENTS. Table of Figures

4.9 BEAM BLANKING AND PULSING OPTIONS

CATHODE-RAY OSCILLOSCOPE (CRO)

Summary of the 1 st Beam Line Review Meeting Injector ( )

Klystron Tubes. Two forms of such a device, also called linear beam klystron, are given in the following figure.

PEP II Design Outline

New Filling Pattern for SLS-FEMTO

RF Power Generation II

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

COMMISSIONING AND FIRST RESULTS OF THE ELECTRON BEAM PROFILER IN THE MAIN INJECTOR AT FERMILAB*

AREAL- Phase 1. B. Grigoryan on behalf of AREAL team

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Linac-Beam Characterizations at 600 MeV Using Optical Transition Radiation Diagnostics *

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

HIGH RESOLUTION LED-MODULES PERFECT VISUAL SOLUTIONS

DIRECT DRIVE ROTARY TABLES SRT SERIES

LHC Beam Instrumentation Further Discussion

An Overview of the Performance Envelope of Digital Micromirror Device (DMD) Based Projection Display Systems

Standard Operating Procedure of nanoir2-s

A HIGHLY INTERACTIVE SYSTEM FOR PROCESSING LARGE VOLUMES OF ULTRASONIC TESTING DATA. H. L. Grothues, R. H. Peterson, D. R. Hamlin, K. s.

Implementing a Proton Beam Scanning System within an Operating Clinical Facility

Failure Analysis Technology for Advanced Devices

Detailed Design Report

SRV02-Series. Rotary Pendulum. User Manual

1ms Column Parallel Vision System and It's Application of High Speed Target Tracking

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

CHECKLIST FOR VERIOS OPERATION 1. GENERAL The SEM lab is used assuming "operating room" cleanliness, i.e., the SEM lab is a high visibility lab and

Abstract. Keywords INTRODUCTION. Electron beam has been increasingly used for defect inspection in IC chip

Auto classification and simulation of mask defects using SEM and CAD images

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

LEP400 Etch Depth Monitor Real-time, in-situ plasma etch depth monitoring and end point control plus co-linear wafer vision system

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

arxiv: v1 [physics.ins-det] 1 Nov 2015

Beam Loss Detection for MPS at FRIB

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

Transcription:

Introducing Purion H, a Scanned Spot Beam High Current Ion Implanter Bo Vanderberg, Patrick Heres, Edward Eisner, Bruce Libby, Joseph Valinski and Weston Huff Axcelis Technologies, Inc. 108 Cherry Hill Drive Beverly, MA 01915, USA Bo.Vanderberg@axcelis.com Abstract As a member of the Purion ion implanter family, Purion H is Axcelis next generation high current implanter. Purion H provides customers with an unprecedented level of process flexibility and yield-enabling technology, and features the platform s four common differentiators: Purion Contamination Shield, Purion Vector Dose and Angle Control System, Purion 500 wafer/hour endstation and the Eterna ELS source. Like Purion M and Xe, Purion H uses a hybrid scan architecture. Its scanned spot beam technology delivers precise dosage, angle and dose rate on all points of the wafer, by permitting simultaneous and independent implant uniformity and angle control. Purion H high also comprises a five-filter beamline to deliver beam purity for low variability and defects: a series of dipole magnets and a deflecting energy filter separate unwanted contaminants from the ion beam. Magnetic beam scanning permits space-charge neutralization of high beam currents, resulting in high productivity via high beam currents in combination with short tune times and a fast 500 wafer/hour end station. Other new features include a maintenance friendly, integrated source extraction system; a novel uniformity correction algorithm; a new, higher output microwave PEF powered by a solid-state amplifier for metals-free charge neutralization of high current beams; and advanced beam diagnostics to quantify average angles and spread of the scanned spot beam. Finally, the dosimetry system, which is common to the Purion M medium current implanter, extends the application space of Purion H beyond the traditional coverage of high current implanters down to doses < 2e11 /cm2, enabling new applications while maintaining productivity. II. THE PURION PLATFORM All Purion implanters are serial implanters using scanned spot beams with hybrid wafer scan. The use of a common platform entails multiple advantages to the user: common modules between implanters provide greater reliability and lower cost of service, as well as easier equipment training. The Purion platform includes a common end station and wafer handling and a common control system. A. Common End Station The Purion end station comprises four load ports, a dual in-air wafer aligner, two atmospheric robots, quad vacuum load locks, two vacuum robots inside a high volume process chamber. With this configuration, the maximum mechanical throughput is 500 wph in single scan mode, and 340 wph in quad mode. During implant the wafer is scanned vertically across a scanned spot beam. The scan mechanism is a SCARA robot [2] designed to provide optimum scan velocity control, reliability, and process cleanliness: all direct drive motors power a high dexterity, precision mechanism in a small package with long stroke, and all mechanisms reside inside the arm outside the process environment to prevent potential contamination problems and to extend the mechanism s maintenance time. Keywords ion implantation systems, high current implant I. INTRODUCTION Purion H was designed to extend the performance envelope of existing high current implanters on two fronts: productivity and yield enhancement. High productivity is ensured by pairing the industry s fastest end station with a high current, scanned spot beam line, and high device yield by building in full control of beam characteristics and wafer processing, including full implant control, process cleanliness and flexibility. Purion H is the third member of the Purion line, after the Purion XE high energy and the Purion M medium current implanter [1]. Figure 1: Purion SCARA scan mechanism, showing two in-vacuum link and the universal electrostatic chuck mounted on an arm housing a tilt motor Axcelis implanters use constant focal length scan, where the wafer implant plane stays constant for all tilt angles. This is deemed particularly important for low energy ion beams, where beam characteristics can change along the beam path.

Constant focal length scan ensures that all points on the wafer see the same spot beam. The common process chamber houses beam diagnostics to control both horizontal and vertical beam angles [3]. B. Control system Each Purion platform features fully automated implant control, comprising a set of computers connected by high-speed Ethernet: a data computer provides a graphical user interface, recipe management and data logging; a VxWorks based real time control computer provides implant and beam (Autotune) control; a PMAC system provides motion control and interfaces to dose control. The dose system uses a dedicated dose controller, capable of fast, simultaneous data acquisition of multiple channels. neutralizing background electrons, thereby achieving very high purveyance transport. A quad doublet shapes and focuses the spot beam after mass-resolution to the scan vertex of a magnetic scanner. The scanned beam is parallelized via an s- bend corrector, a pair of dipoles with opposing magnetic field direction achieving point-to-parallel optics and permitting simultaneous parallelism (via common magnet current) and average scanned beam angle correction (via differential magnet current tuning). The use of an s-bend corrector has more advantages: the path length through the correctors is independent of scan angle, ensuring spot beam uniformity across the scanned beam. Finally, the spot beam focusing to the scan vertex accomplishes parallelization of the spot beam angles, so that the spot beam angle spread can be tuned with the quad doublet while maintaining scanned beam parallelism. The use of five optical elements introduces many bends with dispersion in the beam line, such that only the desired ion beam can reach the wafer. Off-mass species, higher charge-state ions and dimers, and particulate contamination therefore get filtered out in the beam line. Purion H therefore can deliver beam purity for low variability and defects. Figure 2: Block diagram of the dosimetry system, including control computers, Faraday interfaces and Faraday cups. Purion H uses magnetic scanning with a single scan amplifier; electric scanning beamlines like Purion M and Xe use two amplifiers. All Purion implanters use scan waveform correction to reduce scanned flux non-uniformity. This correction can be applied independently of any angle correction, shortening beam tune times and increasing productivity. PURION H BEAMLINE No single beam line is capable of covering the vast range of doses and energies of the ion implantation application space. For high dose, low energy implantation, the Purion H beam line uses a high acceptance beam line with final deceleration to mitigate the effects of space-charge on transport [4]. The beam line can thus be divided into two parts, a higher energy transport beam line that injects beam into a decel lens, and a final energy transport part that consists of an energy filter and a final drift region. D. Final energy transport Deceleration from injected to final energy occurs in a single deceleration gap (see Fig. 3). Immediately following the deceleration, Purion H uses an angular energy filter (AEF) [6], custom designed for high current transport. The AEF deflects ions down such that only ions with the desired energy enter the process chamber. High energy neutrals generated upstream of the filter by charge-exchange processes, in particular, do not get deflected and get trapped in the AEF housing. The final drift to the wafer occurs inside the process chamber, where the wafer handling components and the wafer are protected from the sputtered material and neutrals energized by collisions with the ion beam by enclosing the final drift path with a beam tunnel (Fig. 4). Inside the tunnel, a plasma electron flood (PEF) provides additional space-charge neutralization to aid low energy beam transport. The PEF is a 3.8 GHz solid-state amplifier driven electron-cyclotron resonance driven microwave discharge PEF, operating at higher frequency than the conventional 2.45 GHz [7] to enable higher PEF densities. These are necessary to promote beam transport at energies as low as 200 ev and to neutralize wafer charging at currents higher than 30 ma. C. Injector design The high current injector uses an ELS ion source [5] to generate a high current ion beam subsequently mass-resolved by a 110 degree dipole for high mass-resolution (>50:1). Purion H uses a magnetic scanner to fan the mass-resolved spot beam into a divergent scanned beam; in contrast to electric scanning, magnetic scanning does not strip the spot beam of

pre-amorphized Silicon wafers using two different energy Ge implants. As can be seen, excellent agreement between the profiles is obtained, with possible energy contamination on Purion H close to the detection levels on present SIMS capability. Figure 3: Angular Energy Filter (AEF). From left to right, the optical train comprises: terminal electrode terminal suppression decel gap deflection electrodes ground suppression. Also shown is a gate valve to isolate the beam line vacuum from the process chamber. Figure 5: Comparison of SIMS profiles of a reference drift and 10:1 decel implant on Purion H. No energy contamination can be seen on a highdecel Purion H implant at present detection levels of low energy SIMS. Figure 4: Rendered view of the beam tunnel inside the process chamber. The scanned spot beam is shown in blue, and the microwave PEF is under the beam in close proximity to the wafer plane. III. PROCESS RESULTS Like any qualified implanter, Purion H has to deliver simultaneous compliance to specifications of productivity, process control, and reliability. We will here highlight two performances related to process control that we deem exceptional for high current implanters. A. Energy contamination The use of an AEF enables energy contamination free ion implantation at relatively high deceleration ratios, defined as the ratio of injected to final energy. To illustrate this performance, Fig. 5 shows SIMS profiles of two high current implants: a reference drift implant (no deceleration) on Axcelis Optima HDx, and a 10:1 decel ratio implant on Purion H. Both implants are performed at high spot beam currents (14 ma), with adequate PEF settings to ensure wafer charge neutralization. The implants were performed into dual B. Low energy-low dose Purion H s advanced dosimetry system permits complete setup and closed-loop controlled implant. Since the dosimetry system is shared between all Purion implanters, Purion H has the dynamic range of beam current measurement of Purion M s and Xe s, and can measure and control beam currents in the microampere range. This enables low dose implantation capability at low energies, previously not possible on high current implanters. As examples, we show two wafer maps of relatively low dose implants on Purion H: a 11 B 6 kev 5e13/cm 2 sheet resistance R s map, and a 11 B 5 kev 2e11/cm 2 Thermawave TW maps. The reason for two maps lies in the limitations of implant mapping capability, where sub-e13 R s maps are every insensitive to dopant distribution, whereas TW maps at high doses, low energy are insensitive [8]. The two snapshots of low dose implant together demonstrate the new capability of Purion, extending the implant application space, as illustrated in Fig. 7.

SUMMARY Purion H is Axcelis next generation ion implanter, combining high productivity and yield enabling technology. Commonality of control system, wafer handling and dosimetry enables an extension of the application space beyond the traditional coverage of high current implanters down to doses < 2e11 /cm 2. While maintaining productivity, this could prove enabling technology for new applications. ACKNOWLEDGMENT Our thanks go out to the entire Purion H team for their hard work developing a new high current implanter. Figure 6: B 6 kev 5e13/cm2, 1255 Ohm/sq, 0.35% 1σ REFERENCES [1] S. Satoh et al., Optima XE Single Wafer High Energy Implanter, AIP Conf. Proc. 1066, 2008, pp. 273-276; E. Eisner et al., Optima MDxt: A high throughput 335 kev mid-dose implanter AIP Conf. Proc. 1496, 2012, pp. 340-343 [2] http://en.wikipedia.org/wiki/scara [3] J. David and D. Kamenitsa, Angle Performance on Optima MDxt AIP Conf. Proc. 1496, Ion Implantation Technology 2012, 2012, pp. 344-347 [4] M. Graf et al., Low energy ion beam transport, Proc. of the 14 th Int. Conf. on Ion Implantation, IEEE, 2002, p.359-364 [5] T. Horsky, J. Chen, W. Reynolds, M. Jones, Current status of the extended life source, Proc. IIT 1998, p. 416 [6] US Pat. No. US 6,777,696 B1 [7] B. Vanderberg, T. Nakatsugawa and W. DiVergilio, Microwave ECR Plasma Electron Flood for Low Pressure Wafer Charge Neutralization AIP Conf. Proc. 1496, 2012, pp. 356-359 [8] D. Kamenitsa et al., Therma-wave dose sensitivity considerations, including energy dependence, Conference on Ion Implantation Technology, IEEE, 2000, p.674-677 Figure 7: B 5 kev 30 ua unscanned, 2e11/cm2, 0.31% 1σ, 200 TW units Figure 8: Application space of the Purion platform. Purion H extends the space to low dose, low energy.