INSTRUCTION MANUAL 1. INTRODUCTION

Similar documents
SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

SOFT LED 4 Vari-White INSTRUCTION MANUAL

SUPER LED F6 120W LED Fresnel SPOTLIGHT 100/120V or 230/240V 50/60 Hz (white light, either Tungsten or Daylight balanced Correlated Color Temperature)

BROTHER, BROTHER & SONS

BROTHER, BROTHER & SONS

LEDONARDO 2 USER MANUAL. BROTHER, BROTHER & SONS ApS

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

L5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2

LED Thunder S-150 Code 1097

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

PRODUCT SPECIFICATIONS

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

DMX LED light effect with 4 lenses

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

aorun manual V2.0 MARCH 2018

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

S30-RP LED Soft Light

Ref. No.: LCB-48IP LED COLORUNIT 16X3W TRI DMX

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

S30-C LED Soft Light LIGHTING - PRODUCT SPECIFICATION V1.0

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

JunoScan MK-II LED scanner. user manual

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

PRODUCT SPECIFICATIONS

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Mini LED Pin Spot Light Model: PLS00571

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

PART 1 PRODUCT (GENERAL)...1.

PRODUCT SPECIFICATIONS

Yoke Safety cable loop. Up Light Bulb

Stratos Duo RGB. User Manual. Order code: EQLED371

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

aorun manual V1.0 OCTOBER 2017

ETC Quick Guide. Source Four LED Profile

LCB-320 LED COLORS 320X10MM DMX 16SEG

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Spectra Batten (Order code: LEDJ95)

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

Fusion 120 Zoom. User Manual. Order code: EQLED068

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

LED MOVING HEAD LedWash. 36 x 10w RGBW 4in1 Zooming USER MANUAL. Version 1.0 beta

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

SHOWLINE SL PAR 155 LED LUMINAIRE SPECIFICATIONS.

180w led gobo moving USER MANUAL

Image Marketing Projector 1.6

Elektralite LED Cool White Dazer

MH-X50+ LED spot moving head. user manual

Chroma-Q Studio One 100 D

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

Altman Lighting Spectra Cyc 50 Specification

Nila light fixtures are intended for indoor use only (unless clearly specified for outdoor use).

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

LED ZOOM PAR Please R ead O ver T his M anual B efore O perating T he L ight F ixture.

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

Ilumipanel 36X3 IP Optic RGB

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

USER GUIDE IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL

ORDER CODE: EQLED65 USER MANUAL

LED Spot 300W. Please read this user manual before your operation

SquareLED - Aura Bar & Matrix Beam Light 100

LED Pot 12 1W RGBW LED PAR. user manual

Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1

The features shown in the following graphics may not appear on all Desire Series fixtures. LCD Power In DMX In

192 Channel DMX Controller

sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

LEDWash RGBW USER MANUAL

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

Quick Reference Guide

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

USER MANUAL. B-EYE Light. Please Read Over This Manual Before Operating The Light Fixture

AuraBeam 150 LED. User Manual KEEP THIS MANUAL FOR FUTURE NEEDS

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

Litile34 OPERATION MANUAL

LED-PAR200B USER MANUAL. COLORsplash 200B

INSTALLATION & USER GUIDE

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

Ilumipod 36 IP Optic VW

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

X 5 / XC 5 LED STROBE

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

Hex-color RGBAW+UV LED strip light

50 mw green DMX laser

Transcription:

LED LEONARDO 6 110W LED Fresnel SPOTLIGHT 100/120V or 230/240V 50/60 Hz (white light, either Tungsten or Daylight balanced Correlated Color Temperature) INSTRUCTION MANUAL Pole Operated Manual Operated MANUFACTURER REPRESENTATIVE ILT Italy S.r.l. Via Cancelliera # 10a, 00041 Albano Laziale (Rome- Italy). Tel. +39/06/902901 Fax. +39/06/90231051 U.R.L.: www.desisti.it E-mail: desisti@desisti.it 1. INTRODUCTION Congratulations on your purchase of a LED FRESNEL 6 lighting fixture. Our commitment to Total Customer Satisfaction and our consolidated experience and leadership in design innovation and manufacturing of lighting products for the professional Entertainment Industry means you can depend upon the quality of this product. The LED FRESNEL 6 is a compact, highly efficient Fresnel lens spotlight using a LED ARRAY combined with the DE SISTI Patented optical system to optimize the photometric performances of LED ARRAYS when utilized in combination with either Fresnels or Plano Convex lenses. The Lighting Fixture is DMX Controlled and includes a number of parameters that can be set locally, it is equipped with either a 100/120V or a 230/240V 50/60Hz power supply for AC feed and it is available with either Tungsten or Daylight Balanced CCT. It utilizes Standard accessories from the DE SISTI range of equivalent Fresnel Lens size, such as Barndoor, Colour Frame, Cones, scrims. Pag 1.

2. YOKE AND ACCESSORIES ASSEMBLY SUPER LED F6 (MANUAL OPERATED) SUPER LED F6 (POLE OPERATED) 3. POWER AND DMX DAISY CHAIN The SUPER LED F6 permits both POWER and DMX DAISY CHAIN. In fact each Fixture is respectively equipped with: For DMX: 1 XLR5 pin Panel Mount Male (DMX IN) 1 XLR5 pin Panel Mount Female (DMX OUT) For Mains Supply 1 20A Powercon NAC3MPA BLUE (POWER IN) 1 20A Powercon NAC3MPB WHITE (POWER OUT) It is recommended to Daisy Chain a Max of 10 fixtures, even if the limitations imposed by DMX Standards are for an higher q.ty of units and even if the Powercon Connections are rated for 20A max. Pag 2.

4. SAFETY INSTRUCTIONS Professional use: This luminaire has been designed for professional use and must be operated by qualified personnel only. Not for residential use. Grounding: WARNING: THIS LUMINAIRE MUST BE GROUNDED WARNING: Disconnect Power CORDS before any maintenance work or opening the FUSE HOLDER. Risk of serious injury. Electrical connections: IMPORTANT The cores in this mains lead are colored in accordance with the following code: Europe America Ground Green & yellow Green or green & yellow Neutral Blue White Live Brown Black In case the colors of the cores do not correspond to the colors of the connection points on your plug, please proceed as follows: the green or green and yellow core must be connected to the connection point marked with the letter E or with the symbol or colored in green or in green - yellow; the blue (or white) core must be connected to the connection point marked with the letter N or colored in black; the brown (or black) core must be connected to the connection point marked with the letter L or colored in red. Working conditions Working Position Lighting fixture: Max. Tilting ±90 from horizontal Ambient Temperature, ta at the place of installation and Storage Humidity at the place of installation and Storage Minimum distances from inflammable surfaces Minimum 10 C, maximum +40 C 25-80% (not condensing) Top Back Sides Front 0,2 m. 0,1 m. 0,1 m. 0,75 m. The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above table are the minimum distances recommended. Other requirements for safe use are: A. Do not cover the apertures of the luminaire housing. They are essential for correct ventilation. B. Use only original accessories and spares from De Sisti Lighting. C. Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the luminaire weight. D. In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. E. A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the suspension point and the eyelet at the front of the body. WARNING: DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE. 5. INSTALLATION INSTRUCTIONS The following procedure should be adopted: Before connecting the luminaire to the electrical mains ensure that: A. Earth line is present on the power socket. B. The mains voltage is within the rated range of the luminaire (see technical data on the rating label) C. The front safety shield is present and in good condition. It consists of a Fresnel lens made by borosilicate un-toughened glass, with a Diameter = 150 mm, thickness = 5 mm type ( 3 min ). WARNINGS : Do not operate the product if the ambient temperature exceeds 40 C Provide a minimum clearance of 0,1m (4 in.) around fans and air vents. Pag 3.

SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE BECOME VISIBLY DAMAGED TO SUCH AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES. THE LUMINAIRE SHALL ONLY BE USED COMPLETE WITH ITS PROTECTIVE SHIELD D. Applying power: Never connect to dimmer power. Install a power plug on the power cable using the following pin assigment: 1 : Neutral 2 : Live Green/Yellow : Ground - This fixture must be connected to ground. Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the power on. E. Stand Alone operation: Using the navigation buttons and display readout ( refer to the Local Menu chapter ) navigate to Manual and set the desired intensity (for additional operations see Local Menu chapter) F. DMX operation: Connect a DMX cable Navigate to Address mode (Addr) and set the desired address, (refer to the Local Menu chapter). Connect to DMX controller (refer to the Channel Setting in the Local Menu chapter) and Use it. 6. LOCAL MENU PGM PORT Ù FUNCTION 1 ENTER Ú FUNCTION 2 DISPLAY DMX Presence For Firmware Upgrade Scrolling UP / Increases value function key Select / Confirm Scrolling DOWN / Decreases value function key When the push button are not used for more than 15 seconds the display will go OFF. It will go ON again anytime a push button is activated. Shows the presence of DMX (LED lit = DMX present) DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE: The following are the BASIC FUNCTIONS and COMMANDS that are provided on the LOCAL MENU of the LED FRESNEL. The unit is provided with a USER MENU accessible instantly on the product. The unit has also a SERVICE MENU that is only accessible through a PASSWORD and is reserved for QUALIFIED and TRAINED PERSONNEL: 1st MENU (scrolling with the Ù and the Ú Explanation of Each MENU FUNCTION 2nd MENU buttons) (after pressing the X that stands for E N T E R ) DMX ADDRESS This Function is to SET the DMX address from 1 to 512 (Product is delivered with default settingof the DMX address at 1) Once the C001 is displayed, act on the Ù button to increase the address to the desired value. Temporary push will increment the value by 1, if the button is kept pushed the increment on numbers is getting fast. Once the desired Address number is accomplished press X ( ENTER ) to make it active LOCAL DIMMING CONTROL LOCAL OR REMOTE CONTROL SETTINGS This Function is to LOCALLY DIM the LED INTENSITY from 0 to 100% (Product is delivered with default setting of the DIMMER at 0). The intensity goes in increments of 1/100% so the display will show 000% with the dimmer at 0% and FULL with the dimmer at 100%. Temporary push will increment the value by 1/100, if the button is kept pushed the increment on numbers is getting fast. Once the desired Lighting Level is accomplished and it is wanted to leave that level and go to other functions of the MENU, press ENTER. The LED Fresnel has the facility to block the LOCAL DIMMING SETTING and maintain it when the POWER is turned first OFF and than ON again. This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming level can be blocked, so that for instance a system lighting a SET can be operated by a remote switch or simple brakers by TURNING POWER ON. The relevant menu to access this function is CTRL, to enter in this menu press X ( ENTER ), it is than possible to select either DMX or AUTO by acting on the Ù or Ú button and than press X ( ENTER ) again. The machine is set to DMX as default. Pag 4. In DMX mode: the Fixture accepts DMX control.if in this mode the local DIMMING CONTROL is SET to a level the Light behaviour will follow the HTP (Highest Takes Precedence) modality, in other words it will keep the local DIMMING setting until the DMX level of the specific channel will be higher, from that level onwards the DMX level will take precedence. In this condition if the DMX connection is removed, the light will keep the last level.until power is ON. It will reset and Start at 0after Power OFF and ON again. In AUTO mode: the light will ignore any DMX control. In this mode any local dimming setting will be maintained and will be automatically recalled after power off, when turning the power on again.

1st MENU (scrolling with the Ù and the Ú Explanation of Each MENU FUNCTION 2nd MENU buttons) (after pressing the X that stands for E N T E R ) TEMPERATURE This function Displays in real time the LED ARRAY Case temperature in C. When pressing Enter again you exit from the temperature display. The steady state TEMPERATURE of the ARRAY reaches approx. 55 C after many hours of continuous operation with an ambient temperature of 25-30 C. The Thermal Handling of the LED is Automatically handled by the local electronics and the LED will operate until the ARRAY temperature reaches 80 C, that anyway is still way within the prescribed maximum nominal prescribed by the ARRAY manufacturer that is 105 C. In case the ARRAY temperature reaches 80 C the unit will automatically turn off. Even in extreme Ambient temperature conditions the LED ARRAY shall never reach the 80 C limit. The above protection threshold is there to protect the LED ARRAY from stressed working conditions in case some other failures or specially critical working conditions are causing an over-temperature. CHANNEL SETTING (RESOLUTION & FUNCTION) This Function is to set the DIMMING RESOLUTION either at 8 bits or at 16 bits. Once CHAN is displayed, act on the Ù or Ú buttons to scroll through the following choises: 8D: 8 bits resolution (the display will show 8D and this is the default setting). The Fixture utilises 1 DMX Circuit for the Light Dimming, which is the BASE CIRCUIT set in the ADDRESS. 8DS: NOT ACTIVE (for future use): 16D: 16 bits resolution (the display will show 16D). The Fixture utilises 2 DMX Circuits, the BASE CIRCUIT set in the ADDRESS is the Coarse Dimming, the second Circuit (BASE +1) is the Fine Dimming. 16DS: NOT ACTIVE (for future use): The foreseen function for this setting is: 8 bits resolution and STROBE (the display will show 8DS). The Fixture will utilise 2 DMX Circuits, the BASE CIRCUIT set in the ADDRESS will be the LIGHT DIMMING and the second circuit (BASE +1) will be the STROBE The foreseen function for this setting is: 16 bits resolution and STROBE (the display will show 16DS). The Fixture will utilise 3 DMX Circuits, the BASE CIRCUIT set in the ADDRESS will be the Coarse Dimming, the second Circuit (BASE + 1) will be the Fine Dimming. the third CIRCUIT (BASE + 2) will be the STROBE Of course the 16 bits function is useful if the corresponding circuits on the DMX LIGHTING BOARD are also set at 16 bits. W A R N IN G : if th e L E D F R E S N E L is s e t a t 1 6 b its, b u t m o re u n its a re h a v in g a c o n s e c u tiv e u n ita ry a d d re s s (fo r in s ta n c e firs t fix tu re s e t a t A d d re s s 1, s e c o n d fix tu re s e t a t A d d re s s 2 a n d s o fo rth, th e D M X C h a n n e l c o n tro llin g th e C o a rs e D im m in g o f th e s e c o n d u n it, w ill a ls o c o n tr o l th e fin e d im m in g o f th e fir s t u n it. In th is c a s e it is r e c o m m e n d e d th a t a ll fix tu r e s a r e s e t to 8 b its re s o lu tio n ). DMX LEVEL It Shows the DMX Input level on percentage (0-99% and FULL) received effectively from the Fixture. Press ENTER to exit this MENU. 7. CHARACTERISTICS AND PERFORMANCE DATA DESCRIPTION LED Power Power Cosumption VALUE DESCRIPTION 110 W 130W @ 230 V (50-60 Hz) 138W @ 120 V (50-60 Hz) Protection Type IP 22 Max Housing temperature 70 C Weight of Fixture Weight of barndoor Weight of color frame Size of scrims & color frame Size of Barndoor ring Lens diameter This product uses a 5-pin XLR for DMX Data link USITT DMX512-A DMX Channels: Protection Class DMX input and output. Use a shielded data cables. Do not overload the daisy chain. Up to a maximum of 32 devices can be used on a single DMX chain. 1 at 8bit: Dimmer 2 at 16bit: Dimmer Class 1 ground connection required VALUE M.O. P.O. 7,8 kg. 9,1 kg. 4 leaf 8 leaf 0,63 kg. 0,85 kg. 0,3 kg. Seat Diameter Acc.ies Diameter 187 mm. 185 mm ( 7 1/4 ) Seat Diameter Ring Diameter 192 mm. 190 mm ( 7 1/2 ) 150 mm. Specifications subject to change w ithout notice. Pag 5.

8. DIMENSIONS Dimensions: Black=mm. Red=inches Dimensions: Black=mm. Red=inches 9. PERIODIC INSPECTION & MAINTENANCE This product requires very little routine maintenance, if any, but has special cleaning instructions: Disconnect fixture from power and allow it to cool for 10 min. 1. Vacuum or gently blow away any dust from fan blades and grills 2. Very gently clean the LED with Isopropyl alcohol. 3. Clean the lenses with a soft damp cloth. 4. Check the condition of the safety shield (see chapter: Installation Instructions) before every use. 5. Check Power supply cable and DMX control cable proper conditions 10. SAFETY STANDARDS Europe: The product conforms the Applicable European Directives & Standards Low Voltage Directive: 73/23/EEC (as amended by 93/68/EEC) EMC Directive: 89/336/EEC (as amended by 92/31/EEC & by 93/68/EEC) Europen Standards:: EN 60598-2-17, EN 60598-1, EN 55015, EN 61547 Disposing of this product: Help preserve the environment! Ensure that this product is recycled at the end of its life. This product is in compliance with the RoHS and WEEE directive. Pag 6.