IMPROVEMENTS IN LOW POWER, END-WINDOW, TRANSMISSION-TARGET X-RAY TUBES

Similar documents
Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Teltron Delection Tube D

Mechanical aspects, FEA validation and geometry optimization

3B SCIENTIFIC PHYSICS

Application note. Materials. Introduction. Authors. Travis Burt, Huang ChuanXu*, Andy Jiang* Agilent Technologies Mulgrave, Victoria, Australia

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

Principles of Electrostatic Chucks 6 Rf Chuck Edge Design

The field cage for a large TPC prototype

Development of OLED Lighting Applications Using Phosphorescent Emission System

This work was supported by FINEP (Research and Projects Financing) under contract

P-224: Damage-Free Cathode Coating Process for OLEDs

CNT FIELD EMISSION CATHODE CATALOG. XinRay Systems Inc. April 2014

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

INSTRUMENT CATHODE-RAY TUBE

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

INSTRUMENT CATHODE-RAY TUBE

CATHODE RAY OSCILLOSCOPE (CRO)

Screen investigations for low energetic electron beams at PITZ

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

Optical Engine Reference Design for DLP3010 Digital Micromirror Device

RADIOGRAPHIC PERFORMANCE OF CYGNUS 1 AND THE FEBETRON 705

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

CATHODE-RAY OSCILLOSCOPE (CRO)

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

HAPD and Electronics Updates

Citation X-Ray Spectrometry (2011), 40(6): 4. Nakaye, Y. and Kawai, J. (2011), ED

High Efficiency White OLEDs for Lighting

Development of OLED Lighting Panel with World-class Practical Performance

arxiv: v1 [physics.ins-det] 1 Nov 2015

3B SCIENTIFIC PHYSICS

Standard Operating Procedure of nanoir2-s

CHAPTER 4 OSCILLOSCOPES

HV/PHA Adjustment (PB) Part

Characterizing the Electro-Optic Properties of a Microfabricated Mass Spectrometer

An extreme high resolution Timing Counter for the MEG Upgrade

Progress Update FDC Prototype Test Stand Development Upcoming Work

Academic and Research Staff. Prof. John G. King Dr. John W. Coleman Dr. Edward H. Jacobsen. Norman D. Wittels

Application Note [AN-007] LCD Backlighting Technologies and Configurations

Brown, A., Merkert, J., & Wilson, R. (2014). Build your own particle accelerator. Science in School, (30),

Review Report of The SACLA Detector Meeting

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

Effect on Beam Current on varying the parameters of BFE and Control Anode of a TWT Electron Gun

2.2. VIDEO DISPLAY DEVICES

4.9 BEAM BLANKING AND PULSING OPTIONS

Operation of CEBAF photoguns at average beam current > 1 ma

Drift Tubes as Muon Detectors for ILC

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

( InfoSystems Translation )

The Cathode Ray Tube

Improvements in Gridless Ion Source Performance

:: Reduce needs for heat dissipation components. :: Extend battery life in mobile products. :: Save power and reduce heat generation in TVs

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

Supplementary Figure 1. OLEDs/polymer thin film before and after peeled off from silicon substrate. (a) OLEDs/polymer film fabricated on the Si

Elements of a Television System

New gas detectors for the PRISMA spectrometer focal plane

The hybrid photon detectors for the LHCb-RICH counters

About LED Lighting. White Paper: Operating Characteristics. Low Power LEDs

Lensed Fibers & Tapered Ends Description:

arxiv:hep-ex/ v1 27 Nov 2003

INCA ENERGY EDS TRAINING. System Block Diagram. INCA Energy Software. Xiang Yang EM SMU. Navigators. Point & ID Navigator.

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

THE X-RAY ADVANTAGE Pros and cons X-ray and Gamma

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

High-Current Hollow Cathode Development *

High Performance White OLEDs Technologies for Lighting

Improvements to Siemens Eclipse PET Cyclotron Penning Ion Source

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display

Understanding & Optimising Scanning Electron Microscope Performance

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

S195AVGC-2BM 1.6x0.8mm, Red & Yellow Green LED Surface Mount Bi-Color Chip LED Indicator

Monitor QA Management i model

Q1. Do LED lights burn out?

Non-Destructive Examination Benches and Analysis Laboratories in support to the Experimental Irradiation Process in the Future Jules Horowitz MTR

If you are using a CRT tester/restorer other than the CR7000 you are likely incorrectly testing today s CRTs and risk damaging every one you restore.

In-process inspection: Inspector technology and concept

Uniformity of Plasma Density and Film Thickness of Coatings Deposited Inside a Cylindrical Tube by Radio Frequency Sputtering

Instruments for Surface Science

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display

LEDs, New Light Sources for Display Backlighting Application Note

Transmissive XBPM developments at PSF/BESSY. Martin R. Fuchs

Low-Energy Electron Linacs and Their Applications in Cargo Inspection

OPTIMIZED LIGHT-EMITTING DIODE (LED) DEVICES THAT HAVE A HIGH COLOR RENDERING INDEX (CRI) FOR LIGHTING APPLICATIONS

EMI/EMC diagnostic and debugging

Universal High Current Implanter for Surface Modifications with ion beams Extensive range of ion species, including refractory metals Magnetic mass

Optimization of a triode-type cusp electron gun for a W-band gyro-twa

An RF Excited Plasma Cathode Electron Beam Gun Design

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Nanostructured super-period gratings and photonic crystals for enhancing light extraction efficiency in OLEDs

Basically we are fooling our brains into seeing still images at a fast enough rate so that we think its a moving image.

Hall-B Beamline Commissioning Plan for CLAS12

Light Emitting Diodes

Display Systems. Viewing Images Rochester Institute of Technology

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Industrial Diode Laser (IDL) System IDL Series

Teaching Plasma Nanotechnologies Based on Remote Access

Challenges in the design of a RGB LED display for indoor applications

Transcription:

Copyright JCPDS - International Centre for Diffraction Data 24, Advances in X-ray Analysis, Volume 47. 64 ABSTRACT IMPROVEMENTS IN LOW POWER, END-WINDOW, TRANSMISSION-TARGET X-RAY TUBES Charles Jensen, Stephen M. Elliott *, Steven D. Liddiard, A. Reyes-Mena, Melany Moras, and D. Clark Turner MOXTEK, Inc., Orem, UT USA 8457 * Thin Film Consulting, Longmont, CO USA 851 End-window transmission-target X-ray tubes are designed for very close anode-to-sample coupling for compact portable XRF instruments. Several recent improvements have been achieved to make these tubes considerably brighter, with better output stability and even smaller size and lower power consumption for handheld instrumentation. Areas of the tube that have been improved include the anode, the cathode, and the high-voltage power supply. 1) The anode can be a sputtered film on the inside of the X-ray window. Densified films of a more uniform thickness provide higher X-ray output and more consistent performance from tube to tube. 2) Changes in the anode geometry have resulted in reduced spectral contamination from metal parts in the anode. 3) The electron beam position on the anode is primarily influenced by the filament placement relative to the cathode optic. Using finite-element analysis (FEA) charged-particle beam modeling software it was possible to design an improved cathode optic with significantly better electron beam performance. This results in higher electron density on the target and a more stable beam position. 4) Finally, innovations in the high-voltage power supply have resulted in significant reductions in size and weight in this component. New power supply designs also require significantly less input power than the earlier designs. The combination of these improvements results in miniature X-ray tubes with higher flux, lower spectral contamination, more stable X-ray beams, smaller and lighter packages, and lower overall power consumption. INTRODUCTION With the miniaturization of XRF instrumentation, there has been a need for a compact, portable, battery-powered X-ray tube. In 21 MOXTEK introduced a miniature X-ray tube designed to address the needs of handheld XRF analyzers [1,2]. This tube was designed to be a transmission-target end-window configuration in order to provide very close anode-to-sample coupling. Refer to Figure 1 for details of the interior construction of the tube. To provide for battery operation of the tube the cathode includes a thermionic filament that was designed for very low power consumption, requiring typically only.2 watts input power to produce 1µA of emission current. There is a circular focusing aperture to restrict the electron beam to a central cone. The anode is a sputtered film on the back of the beryllium exit window. Figure 1. Cross section of a transmission target X-ray tube This tube was designed to be a replacement for 19 Cd radioisotope sources commonly used in handheld XRF instruments. The 19 Cd emits primarily the Ag Kα line, so silver was chosen for the anode material. The tube has an additional advantage over the isotope sources, as it produces continuum radiation (see Figure 4 below), which is more efficient at excitation across a span of atomic numbers.

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright JCPDS - International Centre for Diffraction Data 24, Advances in X-ray Analysis, Volume 47. 65 During the last year there have been significant improvements in the design of the tube and matching high-voltage power supply, resulting in increased brightness and flux, lower spectral contamination, and smaller and lighter packages with reduced overall power consumption. In addition, a new cathode optic design promises to improve the repeatability of the beam spot position on the anode, with a considerable reduction in spot size. The combination of these incremental improvements provides a significantly better X-ray source for portable, and particularly handheld, XRF instruments. ANODE IMPROVEMENTS a. Flux One of the important parameters of an X-ray tube is the output flux. The output spectrum of each tube is carefully measured with a Si PIN diode X-ray detector. Details of the experimental setup and measurement approach have been presented elsewhere [3]. In the case of a thin film transmission anode, the output spectrum and resulting tube brightness are a function of the density and thickness of the sputtered film. Table 1. Parameter differences between original and improved silver coating. Thickness is 2.µm. Parameter During investigations of the variability of tube brightness it became apparent that the orientation of the anodes in the sputtering chamber during silver deposition could affect the resulting tube output flux. As expected, tubes positioned at the edges of the chamber fixture had lower output flux than those at the center. Investigation showed that this was due to the window mount shadowing a portion of the anode from the sputtering target. The sample holders were redesigned so that all of the anodes have a direct line-of-sight to the sputtering target. In addition, the sputtering target was further than desired from the substrates, which caused a higher level of Ar gas inclusion in the film. A change in the geometry of the sputter coating equipment provided a closer substrate-totarget distance and improved film density uniformity across the coating batch. These process changes are summarized in Table 1, and the resulting tube brightness improvement can be seen in the silver peak intensity in the output spectrum as recorded in the run chart of Figure 2. b. Spectral Contamination Another important parameter for analytical tubes used for X-ray spectrometry is the degree of Original coating Improved coating Target to substrate sputter distance (cm) 25 3 Sputter gas pressure (mtorr) 2 2 % Theoretical film density (%) 8-9% 98% Uniformity across batch (%RSD) 1% <5% Average silver Kα peak intensity (cps/µa) 111 243 Improvement in brightness 12% Silver Peak Intensity (cps/ua) 4 35 3 25 2 15 1 5 Start of improved silver sputtering 5 52 54 56 58 6 62 64 66 68 7 72 74 Tube # Figure 2. Run chart showing the shift in silver peak intensity with improved silver coating starting at tube #633. See Table 1 for process parameters. spectral contamination characteristic lines in the spectrum from materials other than the anode element. Scatter of these characteristic lines from the sample will result in higher background signal at that particular element, raising the limit of detection for that element and

Copyright JCPDS - International Centre for Diffraction Data 24, Advances in X-ray Analysis, Volume 47. 66 A Figure 3. Cross-sectional view of anode assembly. Circled locations show the radius on the window mount that is in the field of view of the X-ray detector and susceptible to bombardment by backscattered electrons. (A) Original design with.32 radius. (B) New design with.4 radius. collimator this halo is removed, and the resulting X-ray spectrum is free of the contamination lines. Complete details of this characterization work are given in Reference 3. From these measurements, we 2 suspected that most of the 15 contamination peaks were 1 originating from backscattered 5 electrons fluorescing the materials of the monel window mount. This was particularly exacerbated by a large radius area on the window mount designed to reduce stress in the Be window. This radius presented a large amount of monel material in the field of view of the X-ray detector to the backscattered electrons from the primary beam. See Figure 3 for more detail. Spectrum Quality (Contam. Peak/Bkgd) 4 3 2 1 B Total Counts 5 45 4 35 3 25 Fe Kα Ni Kα Processing Date Figure 5. Process control results on spectrum quality metric. Open circles (o) are with a 1.5mm external collimator. Solid squares ( ) are without external collimation. B resulting in generally worse analytical statistics. The CCD measurements of the beam spot on the anode, coupled with spectrum measurements with the PIN diode detectors were taken. The data was collected with no external collimator and with a 1.5mm diameter external collimator. The CCD measurements without a collimator showed a halo of X- rays surrounding the central beam spot. With the 1.5mm Cu Kα 5 1 15 2 Channel Number Tube 1576 - new anode style Tube 126 - old anode style Ag Kα Figure 4. Example spectra before and after the radius change for the window mount. Note the reduced peak heights in tube 1576 with the revised anode design. Change in w indow mount radius Upon examination we determined that this radius was much larger than required for the.1 thick beryllium window. A redesign reduced the radius from.32 to.4. This resulted in a significant reduction in the spectral contamination for uncollimated tubes. Example spectra both before and after the radius change are shown in Figure 4. For process control the spectral contamination is characterized using a Ag Kβ

Copyright JCPDS - International Centre for Diffraction Data 24, Advances in X-ray Analysis, Volume 47. 67 spectrum quality metric, which is the peak height of the contamination peak divided by the height of the continuum background under the peak [3]. Figure 5 shows the process control results for the time period before and after the change on the radius of the window mount. The reduction in spectral contamination is obvious. TARGETED CATHODE IMPROVEMENT The beam spot size, location, and stability on the anode are largely a function of the filament location and the focusing optics at the cathode end of the tube. In an effort to improve spot stability and reduce the spot size for imaging applications we have undertaken an aggressive redesign of the cathode optics. The design was accomplished using Opera electron beam modeling software [4]. The goal was to implement an optimized version of an industry-standard T-slot cathode optic, which required a full 3-dimensional model because of the cylindrical filament. The following approach was used in the design engineering, with some results shown in Figure 6: First, a 2D electrostatic model was generated. Axi-symmetric and XY-symmetric models were generated. Geometrical numerical analysis was necessary in order to optimize the cathode geometry. The geometry permits control of the focusing of electrons emitted from the front and back surfaces of the filament. Next, a 2D space charge model was generated. This built upon the 2D electrostatic model to include the effects of space charge. This includes electron beam trajectories computed with the influence of space charge on beam emission and transport. Indications are that a small beam spot is achievable, with the recommendation to proceed with 3D modeling. Then, a 3D preliminary statics model was generated. This included electric equipotentials and fields for the 3D model with a flat filament. B A 4µm FWHM C Figure 6. Electron beam model of improved cathode. (A) Finished cathode optic model showing electron trajectories. (Trajectories do not indicate current density.) (B) Beam spot profile on the anode in the direction of width of the filament. (C) Beam spot profile in the filament length direction. For reference, graph dimension units are in inches. 6µm FWHM

Copyright JCPDS - International Centre for Diffraction Data 24, Advances in X-ray Analysis, Volume 47. 68 Finally, a 3D space charge model was completed, including electron beam trajectories computed with the influence of space charge on beam emission and transport. The flat filament design was replaced with a cylindrical filament model. Preliminary tube behavior was shown with plots of the electric equipotentials, electric fields, beam trajectories, and the focal spot on the anode surface. Predicted beam focal spot size is shown in Figure 6 along with the model rendering of the filament positioned in the T-slot and some representative electron trajectories. POWER SUPPLY ENHANCEMENTS a. Reduction in Size For handheld instrumentation, it s critical that the X-ray tube and high-voltage power supply combination be as compact as possible. The power supply is typically the bulkiest component. We introduced the miniature tube with a very compact, battery-operated high-voltage power supply. Through aggressive redesign engineering we will soon be able to offer the tube with an even smaller supply. Figure 7 shows the relative size difference in our standard supply and the new prototype. The prototype supply requires only 4% of the volume of the old supply and boasts a 5% reduction in weight. Figure 7. Size comparison of the existing high -voltage power supply on the left with a prototype supply on the right. Volume and weight of the prototype are, respectively, about 4% and 5% of the standard supply. b. Reduced Power Consumption In switching power supplies, smaller size usually results in more losses in the transformers. To minimize these losses, the prototype power supply uses higher operating frequencies. This allows the use of smaller multiplier components and, thus, more high-voltage multiplier stages. The higher number of stages allows operation of the high-voltage transformer at a lower voltage, which helps to reduce the losses in this transformer. Additionally, a proprietary improvement in the filament transformer design provides for better coupling and more efficient energy transfer across the filament transformer isolation barrier. The combination of these changes provides a 3% to 5% reduction in input power consumption, significantly extending battery life in portable instrumentation. c. Improved EMI shielding Power Consumption (W) 1 The original high voltage power supply is encased in a plastic shell. To reduce electrical and magnetic emission from the power supply, the prototype is encased in a.3 aluminum box. 8 6 4 2 Current HVPS Prototype HVPS 2 4 6 8 1 Emission Current (ua) Figure 8. Input power consumption of 2 types of highvoltage power supplies. Data is recorded at 4kV operating potential. The prototype supply uses 5% less power at 2µA emission current and 3% less at 1µA.

Copyright JCPDS - International Centre for Diffraction Data 24, Advances in X-ray Analysis, Volume 47. 69 Table 2. Oscilloscope probe measurements for EMI emissions. Units are in mv induced in probe. Measurement Location To test the EMI emissions, an oscilloscope probe was brought near to the power supply in various locations in both a parallel and perpendicular orientation to the high voltage wires. This was done during operation at 35kV and 2µA emission current. The results of the probe test, reported in Table 2, show conclusively that the aluminum case provides significant EMI shielding. SUMMARY 1 from high voltage wires 16-32 48-64 We have demonstrated significant improvements in grounded-anode, endwindow, transmission-target X-ray tubes. Changes in the design and construction of the thin film transmission anode have provided more than 1% increase in tube brightness and a 6% reduction in spectral contamination. Electron beam modeling using electromagnetic simulation software suggested that significant changes to the cathode optic assembly would provide smaller and more stable beam spots on the anode. Enhancements to the accompanying high voltage power supply have yielded a 6% reduction in the volume of the supply, at the same time achieving a 5% reduction in weight. This was accomplished while also providing enhanced shielding from electromagnetic interference through the use of a metal enclosure. Future improvements to the tube will include the implementation of a redesigned cathode optic for better beam spot control. It is also anticipated that we will implement shielded high-voltage wires for reduced EMI emissions at the wires. Several alternate anode types are in development, including other metal films in transmission-target geometries, and copper, chromium or tungsten tubes in side-window geometries [5]. REFERENCES Original Supply Prototype Supply End near ribbon cable 28-4 none 1 from case near ribbon cable 6-132 none End near high voltage wires 52-12 none 1 from case near HV wires 44-8 none Touching high voltage wires 14-24 56-112 [1] Bullet X-ray Tube, product data sheet, MOXTEK, Inc., Orem, Utah, USA, November (21). [2] Turner, C., Reyes, A., Pew, H., Lund, M., Lines, M., Moody, P., Voronov, S., Mobile Miniature X-ray Tube, US Patent #6,661,876, December 9, (23). [3] A. Reyes-Mena, M. Moras, C. Jensen, S. Liddiard, C. Turner, Characterization Techniques for Miniature Low-Power X-ray Tubes, manuscript F(49), Adv. X-ray Analysis, 47, in press. [4] Opera-3D, electromagnetic simulation software, Vector Fields Ltd, Oxford, UK. [5] S. Cornaby, A. Reyes-Mena, P. W. Moody, T. Hughes, A. Stradling, T. Grow, and L. V. Knight, Simultaneous XRD/XRF with Low-Power X-ray Tubes, Adv. in X-ray Analysis, 45 (22) 34.