Level Measurement Point level measurement - RF Capacitance switches

Similar documents
Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level Measurement Point level measurement RF Capacitance switches

Level Measurement Continuous level measurement - Capacitance transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

Flow Measurement SITRANS F M

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Flow Measurement SITRANS F M

Pressure transmitter For applications in hazardous areas Model IS-3

Mechanical flow switch for On/Off control

TFRN Industrial RTD temperature sensor. CombiTemp TM

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

TFRN Industrial RTD temperature sensor. CombiTemp TM

Modular Lube Lubrication Systems System Controls

2291 Guided Wave Radar Level Transmitter

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

EXPlora. Introduction

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Single Point Flow Monitor SW118 SW119

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

SITRANS F M. Transmitter MAG 5000/6000 4/33

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Capacitance Level Measurement Electronic insert FEC 12

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Bimetal Temperature Switch

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

RMA42. Technical Information

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Horn loudspeaker, Ex proof, short/long flare

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Eddy Current Probe System

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Liquid Level Sensor Type AKS 4100U

Inductive sensor BI1.5-EG08K-Y1

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DMP 331i / DMP 333i LMP 331 i

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Rosemount 1151 Smart Pressure Transmitter

APPLICATIONS. Automatic warehouse. Trasportation lines

Quality products from a single source

Inductive sensor NI10-M18-Y1X-H1141

Technical Information RIA45

Pendant Light Fitting IEC Series 6470/2

Process transmitter RMA422

Inductive sensor NI3-EG08K-Y1-H1341

Signet 2250 Hydrostatic Level Sensor

EXLUX ECOLUX C-LUX 6480 Series

Liquid Level Sensor AKS 4100U

Liquid Level Sensor Type AKS 4100/4100U

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Process Transmitter RMA 422

Inductive sensor With analog output BI15-M30-LI-EXI

I Ex-protected connectors exlink I

8 Installation Equipment

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Type AKS 4100/4100U Coaxial D14 version

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Linear flow controls VFC Linear flow controls with actuator IFC

Level Measurement silometer FMC 420, FMC 423

Dissolved Oxygen Transmitter

Explosion Proof Audible Signal db(a) Series YA60

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

EXLUX ECOLUX 6480 Series

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

ATEX-manual for units

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Liquid Level Sensor AKS 4100U

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

Datasheet EC-750 Ex DOME Camera

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Heating thermostat Series AMHs B Operating Instructions 11.06/

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

7 Lighting Technology

Sensor technologies Proximity sensors Series ST4. Brochure

Transcription:

Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces, solids, liquids, slurries, and foam; with the ability to tune out buildup on probe. Wall restriction Benefits Easy installation with verification by built-in LED Low maintenance with no moving parts Sensitivity adjustment Integrated cable or PBT enclosure versions available Intrinsically Safe, Dust Ignition Proof, and General Purpose options available 50 (2) 50 (2) min. Application s short insertion length of 100 mm ( inch) and versatility in various applications and in vessels or pipes makes it a good replacement for traditional capacitance sensors. Its advanced tip-sensing technology provides accurate, repeatable switchpoint performance. The PPS (Polyphenylene sulfide) probe [optional PVDF (Polyvinylidene Fluoride)] is chemically resistant with an effective process operating temperature range from -30 to +100 C (-22 to +212 F) (7ML5501), and -10 to +100 C (1 to 212 F) (7ML5610). The fully potted design ensures reliability in a vibrating environment such as agitated tanks up to g. When used with a SensGuard protection cover, the CLS100 is protected from shearing, impact, and abrasion in tough primary processes. The is available in three versions. The integral cable version has a stainless steel process and probe options of PPS or PVDF. The fully synthetic version has a thermoplastic polyester enclosure with a PPS process combined with a PPS probe. The standard enclosure version has a thermoplastic polyester enclosure with a stainless steel process in combination with a PPS or PVDF probe. Key Applications: liquids, slurries, powders, granules, food and pharmaceuticals, chemicals, hazardous areas installation, dimensions in mm (inch) /10 Siemens FI 01 Update 10/2017

Technical specifications Mode of operation Measuring principle Input Measured variable Stainless steel process (integral cable or enclosure version) (7ML5501) Inverse frequency shift capacitive level detection Change in picofarad (pf) Fully synthetic process (enclosure version only) (7ML5610) Inverse frequency shift capacitive level detection Change in picofarad (pf) Output Output signal Alarm output... 20/20... ma 2-wire loop... 20/20... ma 2-wire loop Switch output 1) Solid-state: 30 V DC/30 V AC, max. 82 ma Max. switching voltage: 60 V DC/30 V AC Max. switching current: 1 A Fail-safe mode Min. or max. Min. or max. Accuracy Repeatability 2 mm (0.08 inch) 2 mm (0.08 inch) Rated operating conditions Installation conditions Location Indoor/outdoor Indoor/outdoor Ambient conditions Ambient temperature -30... +85 C (-22... +185 F) -10... +85 C (1... 185 F) Installation category I I Pollution degree Medium conditions Relative dielectric constant r Min. 1.5 Min. 1.5 Process temperature -30... +100 C (-22... +212 F) -10... +100 C (1... 212 F) Pressure (vessel) -1... +10 bar g (-1.6... +16 psi g), nominal 2) -1... +10 bar g (-1.6... +16 psi g), nominal Degree of protection - Enclosure version IP68/Type /NEMA IP68/Type /NEMA - Integral cable version IP65/Type /NEMA Not applicable Cable inlet ½" NPT (M20 x 1.5 optional) ½" NPT (M20 x 1.5 optional) Design Enclosure/Integral cable Fully synthetic version version Material Body Thermoplastic polyester Thermoplastic polyester (Enclosure version) Lid (Enclosure version) Transparent thermoplastic polycarbonate (PC) Transparent thermoplastic polycarbonate (PC) Integrated cable body (Integral cable version) 316L stainless steel Not applicable Sensor length (nominal) 100 mm ( inch) 100 mm ( inch) Process material of probe/wetted parts 3) Connection (Enclosure version) Connection (Integral cable version) Process Power supply Connection: 316L stainless steel; Process seal: FKM (optional FFKM); Sensor: PPS (optional PVDF) ) Internal 5-point terminal block, ½" NPT wiring entrance, M20 x 1.5 optional conductors, 1 m (3.3 ft), 0.5 mm² (22 AWG), shielded, polyester jacket ¾" NPT [(Taper), ANSI/ASME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] PPS process and PPS sensor (Uni-Construction) Removable internal 5-point terminal block, ½" NPT wiring entrance, M20 x 1.5 optional Not applicable ¾" NPT [(Taper), ANSI/ASME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] Standard 12... 33 V DC 12... 33 V DC Intrinsically Safe 10... 30 V DC (Intrinsically Safe barrier required) Not applicable Certificates and approvals Stainless steel process (integral cable or enclosure version) (7ML5501) Fully synthetic process (enclosure version only) (7ML5610) General: CE, CSA, FM, General: CSA, FM RCM Marine: Lloyds Register of Shipping, categories ENV1, ENV2, and ENV5 Dust Ignition Proof (barrier required): CSA/FM Class II and III, Div. 1, Groups E, F, G T Intrinsically Safe (barrier required): CSA/FM Class I, II, and III, Div. 1, Groups A, B, C, D, E, F, G T ATEX II 1 GD 1/2GD EEx ia IIC T to T6 T107 C Overfill protection: WHG (Germany) 1) When synthetic process version (7ML5610) is used in wet locations, switching voltage of the relay is limited to 35 V DC/16 V AC. 2) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /1. 3) For caustic materials, consult a local sales person for alternative O-rings. For more information, please visit http://www.automation.siemens.com/aspa_app. ) When FFKM O-ring (Option A22) is selected, process temperature is restricted to -20 C (- F). Siemens FI 01 Update 10/2017 /11

, stainless steel process Compact 2-wire inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces, solids, liquids, slurries and foam, with the ability to tune out buildup on probe. 7ML5501-0 7 7 7 7 Click on the for the online configuration in the PIA Life Cycle Portal. Process ¾" NPT [(Taper), ANSI/ASME B1.20.1] A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] J Approvals General Purpose: CE, CSA, FM, RCM A CSA/FM Class I, II, and III, Div. 1, Groups A, B, C, C D, E, F, G T; ATEX II 1 GD 1/2GD EEx ia IIC T... T6 T107 C 1) CSA/FM Class II and III, Div. 1, Groups E, F, G 1) G Device version Integral cable version (PPS probe) 1 Enclosure version (PPS probe), ½" NPT cable inlet 3 Integral cable version with PVDF probe body 5 Enclosure version with PVDF probe body 6 (½" NPT cable inlet) Enclosure version (PPS probe), 7 M20 x 1.5 cable inlet Enclosure version with PVDF probe body, 8 M20 x 1.5 cable inlet Overfill protection Not required 0 Required (WHG) 1 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 10/11 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag Y17 [70 x 13 mm (2.75 x 0.5 inch)]: Measuring-point number/identification (max. 20 characters) specify in plain text FFKM seal O-ring 1) A22 Material inspection Certificate Type 3.1 per EN C12 1020 Operating Instructions Note: due to ATEX regulations one Quick start manual is included with every product. All literature is available to download for free, in a range of languages, at http://www.siemens.com/processinstrumentation/ documentation 1) See Temperature restriction on page /1 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 10/11 in the appendix. Accessories SensGuard, ¾" NPT (PPS) SensGuard, R 1" (BSPT) (PPS) Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), one text line, suitable for enclosures Siemens Intrinsically Safe Barrier (DC powered), ATEX II 1 G EEx ia ½" NPT cable gland, nickel plated brass, fits cable diameter 6... 12 mm (0.2... 0.7 inch) -0... +100 C (-0... +212 F), IP68 (General Purpose) M20 x 1.5 cable gland, PA polyamide, ATEX II 2G EEx e II, fits cable diameter 7... 12 mm (0.28... 0.7 inch), -20... +70 C (-... +158 F), IP68 (General Purpose), PPS process Compact 2-wire inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces, solids, liquids, slurries and foam, with the ability to tune out buildup on foam. Click on the for the online configuration in the PIA Life Cycle Portal. Process (PPS) ¾" NPT [(Taper), ANSI/ASME B1.20.1] (PPS probe body) R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] (PPS probe body) 7ML1830-1DL 7ML1830-1DM 7ML1930-1AC 7NG12-0AA00 7ML1830-1JA 7ML1830-1JC 7ML5610-0 7 7 7 7 Approvals General Purpose: CSA, FM D Versions/Options Enclosure version, PPS process, ½" NPT cable inlet Enclosure version, PPS process, M20 x 1.5 A B 1 2 Overfill protection Not required 0 Required 1 Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag Y17 [70 x 13 mm (2.75 x 0.5 inch)]: Measuring-point number/identification (max. 20 characters) specify in plain text FFKM seal O-ring 1) A22 Material inspection Certificate Type 3.1 per EN C12 1020 Operating Instructions Note: due to ATEX regulations one Quick start manual is included with every product. All literature is available to download for free, in a range of languages, at http://www.siemens.com/processinstrumentation/ documentation Accessories SensGuard, ¾" NPT (PPS) SensGuard, R 1" (BSPT) (PPS) Tag, stainless steel, 12 x 5 mm, (0.7 x 1.77 inch) one text line, suitable for enclosures Order code 7ML1830-1DL 7ML1830-1DM 7ML1930-1AC 1) See Temperature restriction on page /1 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 10/11 in the appendix. /12 Siemens FI 01 Update 10/2017

Options Optional SensGuard Internal thread ¾" NPT 32 (1.26) Process ¾" NPT Process R 1" (BSPT) 91 (3.6) 70 (2.75) 91 (3.6) 32 (1.26) 70 (2.75) Optional SensGuard, dimensions in mm (inch) Siemens FI 01 Update 10/2017 /13

Characteristic curves Pressure/temperature curve CLS100 Threaded process s (7ML5501) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -22 ºF 1 ºF (-30 ºC) (-10 ºC) -50 ºC (-58 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) -29 ºC (-20 ºF) Permitted operating temperature T Example: Permitted operating pressure = 10 bar (15 psi) at 75 C process pressure/temperature derating curves Dimensional drawings Integral cable version Enclosure version 80 (3.2) Ground post Power LED (green) Sensitivity trimpot Cable Ø 5 (0.2) Trimpot cap 36 (1.) nominal* Cable relief Output status LED (red) Sensor status LED (yellow) Power LED (green) Sensitivity trimpot Sensor status LED (yellow) Output status LED (red) 1 2 3 5 65 (2.6) Cable inlet ½" NPT (optional M20 x 1.5) Terminal block Ground lug 120 (.7) 50 (2.0) 98 (3.9) nominal Process Process 98 (3.9) nominal 72.5 (2.9) 120 (.7) 20 (8.0) *Some G thread configurations deviate from this size., dimensions in mm (inch) /1 Siemens FI 01 Update 10/2017

Schematics Integral Cable Version - Non Intrinsically Safe only LOW/HIGH Alarm Black Red Polarity as required for desired operation 12... 33 V DC /20 ma Loop Alarm Black Rmax = Vsupply - 10 V 20 ma Solid State Switch Version Red Black V supply 12... 33 V DC Solid state switch, 30 V DC/AC (peak) 82 ma (max) Red V supply 12... 33 V DC Enclosure and Fully Synthetic Version 1 2 3 5 Terminal operations Cable equivalent ma current loop (+V or -V) Red wire ma current loop (+V or -V) Black wire ground Cable shield Solid state switch/relay* wire Solid state switch/relay* wire Note: * Switch/relay normally open in unpowered state * Relay not available on IS version (7ML5501) When driving an inductive load (for example, an external relay), a protection diode must be connected in the correct polarity to prevent possible switch damage due to inductive spikes generated by switching the inductor (please refer to instruction manual). Intrinsically Safe Models - please follow local regulations and area classifications; refer to instruction manual for more details. s Siemens FI 01 Update 10/2017 /15