Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Similar documents
Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Model Number Structure

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Multifunction Digital Timer

Self--powered Time Counter

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

Self-powered Totalizer

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Self-powered Totalizer New H7E

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Accessories (Order Separately)

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Solid-State Digital Timer

Model Number Structure

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Ordering Information. Self-Powered Tachometer H7ER. Subminiature Tachometers With Improved Appearance and Features. H Large display with 8.

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

USER S MANUAL. FX2N-8AD Analog input block

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

User s Manual. LG Industrial Systems G3F AT4A. LG Programmable Logic Controller

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

K3NX Process Meter OPERATION MANUAL

02/11/2015

Features. Digital Time Switch H5S. Easier and More Convenient to Use

Photoelectric Sensors E3F2

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

02/11/2015

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Digital Time Switch H5S. Features. Easier and More Convenient to Use

H8GN. Model Number Structure. Ordering Information. Preset Counter/Timer (48 24) Model Number Legend. List of Models

Cylindrical Photoelectric Sensor CY-100 SERIES

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Indoor Linear 80W Driver SI-C215280N2KR

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Datasheet - SRB-E-201ST

Q3X Laser Contrast Sensor

Electrical connection

Ordering details. Approval. Classification

Type Contact form Model

Datasheet - SRB301LC 24VAC/DC

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Cat. No. O008-E1-04 USER S MANUAL. 3F88L-160/162 Cam Positioner

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

3M Sensored Termination (15 kv) QX-T15I-vi1-E

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

TRF STEP-DOWN TRANSFORMER USER MANUAL

LONWORKS Fibre Optic Converter

Installation Manual SaVi Note Underwater LED Light

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Absolute Rotary Encoder E6CP

Time-Lag Relays. User s Handbook (General Model)

15 Series - Dimmer

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Colour Explosion Proof Video Camera USER MANUAL VID-C

Digital Indicating ORP Meter AER-101-ORP. Instruction Manual

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

GC61 Digital Pressure Gauge. Operation Manual

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Weighing Meter. Ordering Information. Highly Functional Weighing Meter with Easy-to-read LED. Base Units

EZ-LIGHT K30L Series With Independent Push Button Contact

LED Driver Linear / area fixed output

Frequency/Rate Meter

Q3X Laser Contrast Sensor

KHT 1000C HV-Probe Calibrator. Instruction Manual

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

Electronic M.O.P Card. Instruction Manual Model D

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SH2RE16A4. Output relay module. Benefits. Description

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

MICROMASTER Encoder Module

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LED Driver Compact fixed output

Installation Guide VL-MV10. Model No.

Input type NPN/Voltage pulse PNP 240 VAC

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Transcription:

Multi-maintenance Counter/Timer (DIN 72 x 72) CSM DS_E_5_4 Nine Built-in Counters/Timers to Measure Equipment Operating Cycles and Times and Forecast Maintenance Timing Provides up to nine counters or accumulative timers. (Counter and timer functions can be used at the same time.) Individual forecast outputs to indicate maintenance timing. Pre-forecast display and machine stoppage output provided. IP54 oil-proof type at setting area for resistance to oil and water. Separate digit keys to easily change settings. Compact, short-body: 72 72 79 mm (DIN). protection function prevents incorrect operation. Multiple outputs: NPN/PNP. Directly connectable to 2-wire DC sensors. Complies with UL and CSA. Ordering Information Multi-maintenance Counter/Timer Preset stage Nameplate lettering Model 3-stage setting Japanese A DC24 English B DC24 1-stage setting Japanese AD DC24 English BD DC24 Specifications For the most recent information on models that have been certified for safety standards, refer to your OMRON website. The can be used as a multi-stage preset counter. Refer to Safety Precautions on page 7. Accessories (Order Separately) Name Hard Protective Cover (See note 1.) Rubber Packing (See note 1.) Short-circuit plate (See note 2.) Item Model A/RB AD/RBD Classification 3-stage setting 1-stage setting Mounting method Flush mounting External connections Screw terminals Degree of protection IP54 oil-proof type (case front) Input mode Up Output mode F mode (Operation continues even when setting is reached.) Reset system External, manual resets Timer operation Yes Input method Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) Control output No-contact outputs: RUN, forecast, machine stoppage No-contact outputs: RUN, forecast Count, preset value, counter number, and error codes displayed on 7-segment LCD Display Mode, reset, I/O inhibit, re-monitor modes, and key protection displayed on LCD characters Output indication on LCD characters and LEDs LCD with backlight Yes Built-in counter number 9 (counters 1 to 9) (See note 1.) Preset stage 3-stage (See note 2.) 1-stage (See note 3.) Digits Forecast value: 6 digits (999999) Pre-forecast value: 5 digits (See note 4.) Machine stoppage: +5 digits (See note 5.) Forecast value: 6 digits (999999) Time ranges Memory backup Forecast value: 99999.9 h (.1 h or longer)/ 99999.9 s (.1 s or longer) Pre-forecast value: 9999.9 h/ 9999.9 s (See note 4.) Machine stoppage: +9999.9 h/+9999.9 s (See note 5.) Model Y92A-72C Y92S-25 Y92S-26 Note 1. A Hard Protective Cover and Rubber Packing are supplied with the Counter. 2. The @ is provided with short input as standard to achieve a Multi-stage Counter without having to use a short-circuit plate and external wiring. Forecast value: 99999.9 h (.1 h or longer)/99999.9 s (.1 s or longer) EEPROM (Data can be written 1, times.), Backup time for power interruption: Approx. 1 years Note 1. Each channel operates on a separate I/O. 2. The 3-stage are pre-forecast, forecast, and machine stoppage. Pre-forecast: Displayed only on LCD (no external output is provided). Forecast: Displayed on LCD and LED and output (output for each counter). Machine stoppage: Displayed on LCD and LED and output (output when the count value of one or more of counters 1 to 9 has reached its machine stoppage value). 3. This Counter operates on the forecast value only. 4. The pre-forecast value is set as a negative offset in respect to the forecast value. 5. The machine stoppage value is set as a positive offset in respect to the forecast value. 1

Specifications Ratings Rated supply voltage 24 VDC Operating voltage range 85% to 11% of rated supply voltage (See note 1.) Power consumption Approx. 1.7 W (at 26.4 VDC) 3 Hz for count inputs 1 to 7, Max. counting speed Switchable between 3 Hz and 5 Hz for count inputs 8 and 9 Min. counting input signal width One-shot time 2 ms (See note 2.) Count, reset, short, counter number selection, and I/O inhibit input Control output Surrounding air temperature Ambient storage temperature Ambient operating humidity Case color Count inputs 1 to 7: 16.7 ms (ON:OFF = 1:1) Count inputs 8 and 9: 16.7 ms/1 ms selectable (ON:OFF = 1:1) Reset input: 1 ms max. Short input: 75 ms max. Counter number selection input: 3 ms max. I/O inhibit input: 16.7 ms max. Voltage input High level: 16 to 26.4 VDC Low level: to 3 VDC (input resistance: approx. 2.2 kω) Open-collector output: 1 ma max. at 3 VDC max. 1 to +55 C (with no icing or condensation) 25 to +65 C (with no icing or condensation) 25% to 85% Dark gray (Munsell 5Y3/1) Note 1. Ripple content: 2% max. 2. This signal is output as a carry signal when the Counter is used as a total counter. Characteristics Insulation resistance Dielectric strength voltage Impulse withstand voltage Noise immunity Static immunity Shock resistance Weight Vibration resistance Destruction Malfunction Destruction Malfunction 1 MΩ min. (at 5 VDC) (between current-carrying terminals and exposed non-current-carrying metal parts) 1, VAC, 5/6 Hz for 1 min (between currentcarrying terminals and exposed non-current-carrying metal parts) 1 kv (between power terminals) 1.5 kv (between current-carrying terminals and exposed non-current-carrying metal parts) ±48 kv (between power terminals) and ±48 V (between input terminals), square-wave noise by noise simulator (pulse width: 1 ns/1 μs, 1-ns rise) Malfunction: 8 kv; destruction: 15 kv 1 to 55 Hz with.75-mm single amplitude, 2 hours each in three directions 1 to 55 Hz with.5-mm single amplitude, 1 minutes each in three directions 3 m/s 2 3 times each in 6 directions 2 m/s 2 3 times each in 6 directions Approx. 25 g (Counter only) Applicable Standards Safety standards UL58 (See note 1.)/CSA C22.2 No.14 EN61326 (EMI) EN61326-1 (See note 2.) Emission Enclosure: EN61326-1 (EN5511 Group 1 Class A) Emission AC Mains: EN61326-1 (EN5511 Group 1 Class A) (EMS) EN61326-1 (See note 2.) EMC Immunity ESD: EN61326-1 (EN61-4-2): Contact discharge: 4 kv, air discharge: 8 kv Radiated electromagnetic field immunity: EN61326-1 (EN61-4-3): 1 V/m (Amplitude modulated, 8 MHz to 1 GHz, 1,4 to 2, MHz) 1 V/m (Pulse-modulated, 9 MHz ±5 MHz) Immunity Burst: EN61326-1 (EN61-4-4): 2 kv power-line, 1 kv I/O signal-line Immunity Surge: EN61326-1 (EN61-4-5): 1 kv line to line (power line), 2 kv line to ground (power line) Immunity Conducted Disturbance: EN61326-1 (EN61-4-6): 1 V (.15 to 8 MHz) Note 1. Attach a waterproof cover of Y92A-72N. 2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) 2

Connections Internal Connections Count input 1 Count input 2 Count input 3 Count input 4 Count input 5 Count input 6 Count input 7 Count input 8 Count input 9 Counter No. selection Reset input I/O inhibit input Short input 24 25 26 27 28 17 18 19 2 23 22 16 15 1 11 12 13 14 3 4 5 6 9 8 7 Forecast output 1 Forecast output 2 Forecast output 3 Forecast output 4 Forecast output 5 Forecast output 6 Forecast output 7 Forecast output 8 Forecast output 9 Machine stoppage output RUN output Output COM OR Output method Switching capacity Residual voltage Leakage current RUN, machine stoppage, forecast 1 to 9 Open collector 3 VDC max., 1 ma max. 2 VDC max. 1 μa max. Note 1. When the load is short-circuited, the internal circuits may be damaged. 2. Connect a diode to suppress Counter surge when an inductive load is connected. OR 16 to 26.4 VDC Input COM 21 2 1 +24 V V (24 VDC +1% 15% ) Note 1. AD/-RBD outputs the forecast and machine stoppage values simultaneously. 2. The I/O terminals are used for both PNP and NPN. There is no polarity. I/O Functions Inputs Count 9 inputs Reset 1 input Short Counter No. selection I/O inhibit Input count values. Used as time count input signal when timer is used. Max. counting speed receivable: Count inputs 1 to 7: 3 Hz (Min. signal input width: 16.7 ms), Count inputs 8 and 9: 3 Hz/5 Hz (Min. signal input width: 16.7 ms/1 ms) Resets count/time value of a displayed Counter No. Counter under reset does not operate as its output is turned OFF. Reset signal input received while re-monitor function is ON restores reset count/time value of the specified counter. While reset signal is ON, RESET indicator lights. When the short input is ON, an input is also received for one of the count inputs 2 to 9 when an input is received for count input 1. The H8BM can thus be used as a multi-stage preset counter without performing external short-circuit wiring. Specifies counter whose count/time value is to be displayed. Inhibits count inputs of all counters. Turns OFF all forecast outputs, RUN outputs, and machine stoppage outputs. While I/O inhibit signal is ON, INHB indicator lights. Outputs Forecast 9 outputs RUN 1 output Machine stoppage 1 output (Common) Each of these outputs turns ON when its forecast value has been reached. When a total counter is used, output one-shot signals as carry signals. Retain outputs until count values are reset. Turns ON when Counter is operating normally. Turns ON when count value of one counter has reached set machine stoppage value. Retains output until count value is reset. Note: The input and output signals are enabled when power is applied to the Counter. During a power failure, the input signals are disabled, and the output signals are turned OFF. 3

Terminal Arrangement 22 23 24 25 26 27 28 15 16 17 18 19 2 21 8 9 1 11 12 13 14 1 2 3 4 5 6 7 22 23 24 25 26 27 28 Reset input Counter No. selection Count input 1 Count input 2 Count input 3 Count input 4 Count input 5 15 16 17 18 19 2 21 Short input I/O inhibit input Count input 6 Count input 7 Count input 8 Count input 9 Input COM 8 9 1 11 12 13 14 RUN output Machine stoppage Forecast output 1 Forecast output 2 Forecast output 3 Forecast output 4 Forecast output 5 output 1 2 3 4 5 6 7 Power supply: V Power supply: 24 V Forecast output 6 Forecast output 7 Forecast output 8 Forecast output 9 Output COM I/O Connections Input Circuits Output Circuits 5 V Output INCOM 1.4 kω 43 Ω Photocoupler 39 V 39 V OUTCOM Input 1.4 kω Note: Although the input terminals are electrically insulated from the internal circuit, do not conduct an insulation resistance test on these terminals. Note: Although the output terminals are electrically insulated from the internal circuit, do not conduct an insulation resistance test on these terminals. Example of Input Connections (Solid-state Switches) Two-wire Sensors The count input, counter number selection, reset input, I/O inhibit input, and short input signals are input when the two-wire Sensor turns ON. Two-wire Sensors 24 VDC Two-wire Sensors 24 VDC Note: Use the following two-wire Proximity Sensors: (1) High-level: transistor ON Switching capacity: 5 ma min. Residual voltage: 4 VDC max. (2) Low-level: transistor OFF Leakage current: 1.5 ma max. (3) Operating voltage range: 2.4 to 26.4 VDC We recommend using OMRON E2E-X@D@-N Sensors. Three-wire Sensors NPN Type PNP Type Example of Input Connections (Contact Switches) Sensor main circuit Sensor main circuit Sensor main circuit Sensor main circuit *H: Contact ON. *Use a contact which can adequately switch 13 ma at 3 V. 4

Operating Methods Timing Charts 1. Counter (3-stage Preset Operation) 2. Timer (3-stage Preset Operation) Reset input Reset input Count value Count input 999999 Machine stoppage value Forecast value Pre-forecast value Time value Count input 99999.9 h Machine stoppage value Forecast value Pre-forecast value. h Pre-forecast indicator (no output) Forecast output and indicator Machine stoppage output and indicator Pre-forecast indicator (no output) Forecast output and indicator Machine stoppage output and indicator 3. Total Counter Operation 4. Total Timer Operation Reset input Reset input Count input Count input 999999 99999.9 h Count value Time value. h Forecast output (indicator) Note: The count will return to when 999999 is exceeded. When the power supply is turned OFF, the display and outputs will turn OFF, but the current count/time value will be stored in internal memory. Nomenclature One-shot time: 2 ms Forecast output (indicator) Initial Setting Mode Indicator Indicates that the system is in the initial setting mode. I/O Inhibit Indicator Indicates that the I/O inhibit input signal is ON. Re-monitor Indicator Indicates that the system is in the re-monitor function operation. RESET Indicator Indicates that the system is resetting. Protection Indicator Indicates that operation of the keys on the front panel is disabled. Counter No. Indicator Indicates the number of the counter whose data is currently displayed. RESET Resets the count value and output signals. COUNTER No. Selects the counter in sequence each time this Selector is pressed: 1 2 3 4 5 6 7 8 9 (Any counter whose forecast value is set to is skipped in RUN mode.) The following indicators light to show that the count value has reached the preset value and that the output has turned ON. Control Output Indicator (Red LED): Pre-forecast value: LCD lights Forecast value: RED LED lights Machine stoppage value: Control Output Indicator (LCD) Indicator flashes between red and green and LCD output indicator flashes. Set Mode Indicator RUN mode OFF Forecast value Pre-forecast value Machine stoppage value Current Value (1-mm Height) Indicates the current count (current time in timer mode). Time Range Indicator s: seconds, h: hours Multiplication Counter Indicator Indicates that the system is in multiplication counter function operation. Preset Value (7-mm Height) Indicates the forecast value during RUN operation. Indicates the set value in each setting mode. Up s 1 to 6 Each of these keys increments the preset value of the corresponding digit, each time it is pressed. Selects the mode in sequence each time this key is pressed: RUN Forecast Value Pre-forecast value Machine stoppage value 1 2 3 4 5 6 7 8 9 SET Inputs the set or changed data. Note: Models with only 1-stage setting (AD/RBD) are not provided with pre-forecast and machine stoppage output function; only the forecast output function is provided. 5

Dimensions (Unit: mm) Counter Counter 9 85.7 79 75 64.5 55 6 36 11 75 72 72 59 67.5 67.5 Hard Protective Cover (transparent) Installation Installation Diagram To mount the Counter, attach the two supplied brackets to the left and right sides of the Counter, and securely tighten the knurled screws on the brackets by hand, keeping the Counter balanced on the right and left. The performance may not be satisfactory if the screws are loose or excessively tightened. If the knurled screws are excessively tightened with pliers or other tool, damage may result. Panel Cutouts The panel cutout is as shown below (according to DIN 437). The mounting panel thickness must be 1 to 5 mm. Mount the Counter so that the ambient temperature will not exceed 55 C. 68 +.7 68 +.7 78 min. Attach the brackets in line with the rail guides (ridges) on the case. 13.7 α 75 + α 57.5 Supplied mounting brackets (2) Be sure that there is no gap between the brackets and the knurled screws once the knurled screws have been tightened. 78 min. Spacing with Other Devices Provide enough space around the Counter when mounting it to ensure a proper working space. Hard Protective Cover (transparent) Rubber packing Mounting panel Knurled screw 1 M 3 5 screws are used. Select solderless terminals referring to the figure below. 8 ISO4757 Phillips screwdriver #2 3.2 5.8 Other components 6

Safety Precautions Refer to Safety Precautions for All Counters. CAUTION Fire may occasionally occur. Tighten terminal screws securely to a tightening torque of.5 to.6 N m. Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. Precautions for Safe Use In order to ensure safe operation, be sure to observe the following points. (1) Store the Counter within the specified temperature range. If the Counter has been stored at a temperature under 1 C, allow the Counter to stand at room temperature for at least 3 hours before using it. (2) Use the Counter within the ratings specified for ambient operating temperature and ambient operating humidity. (3) Do not operate the Counter in any of the following locations. Locations subject to sudden or extreme changes in temperature. Locations where high humidity may result in condensation. (4) Use the Counter within the specified ratings for vibration and shock. (5) Do not use the Counter in locations subject to excessive dust, corrosive gases, or direct sunlight. (6) When using the Counter in environments subject to large amounts of static electricity (e.g., pipes carrying molding materials, powders, or fluid materials), separate the Counter as far as possible from the sources of static electricity. (7) Use the Counter within the specified ratings for vibration, shock, water immersion, and exposure to oil. (8) Always use a thermo-switch on the load circuit when a heater is used. (9) Do not use organic solvents (such as paint thinner or benzene), strong alkalis, or strong acids because they will damage the external finish of the Counter. (1) Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. (11) Be sure that all terminals are wired correctly. (12) Do not connect more than two crimp terminals to the same terminal. (13) Use the specified wires for wiring. Applicable Wires AWG22 to AWG14 (cross-sectional area of.326 to 2.81 mm 2 ) Solid or twisted wires of copper (14) Always maintain the load current within specifications. (15) Use a switch, relay, or other contact device to turn OFF the power supply instantaneously. Outputs may malfunction and memory errors may occur if the power supply voltage is decreased gradually. (16) Up to two wires of the same size and type can be inserted into a single terminal. (17) Separate the input devices, input wiring, and Counter as far as possible from sources of noise and power lines carrying noise. (18) The life of internal parts may be reduced if Counters are mounted in close proximity to each other. (19) Maintain voltage fluctuations in the power supply within the specified range. (2) Use a switch, relay, or other contacts so that the rated power supply voltage will be reached within.1 s. If the power supply voltage is not reached quickly enough, the power source may fail to reset or the outputs may fall to operate correctly. (21) Do not leave the Counter for long periods at a high temperature with output current in the ON state. Doing so may result in the premature deterioration of internal components (e.g., electrolytic capacitors). (22) Periodically inspect and replace the rubber packing. It may deteriorate, expand, shrink, or harden in some operation environments. (23) Check that the backlight, output indicators, and LCD are operating normally. Some operating environments may accelerate deterioration of the indicators, LCD, and resin components and cause display malfunctions. Periodically inspect and replace parts. (24) Be sure that the voltage applied is within the specified range; otherwise, the internal elements of the Counter may be damaged. Precautions for Correct Use (1) Be sure that the capacity of the power supply is sufficient. The Counter may not start due to the capacity of the power supply or the inrush current that may flow for an instant (approx. 1.6 A for 12 ms) when the Counter is turned ON. (2) The Power Supply, input, and output circuits are electrically isolated inside the Counter. When turning the power ON and OFF, input signal reception is sometimes possible, sometimes not possible, and sometimes unstable, as shown in the diagram below. Power supply ON OFF Input signal reception 2 ms to 1 ms 1 ms to 9 ms Impossible Unstable Possible Unstable Impossible Turn on or off the operating power source all at once by using switch or relay contact. (3) EEPROM is used to back up the memory if the power fails. Data can be written to EEPROM 1, times. Data is written to the EEPROM when the settings are changed or deleted or the power is turned OFF. (4) The Counter uses a constant read-in system, so outputs will turn ON if the set values are changed during operation such that the set value is equal to or less than the count value. (5) Dispose of the Counter in accordance with all local industrial waste disposal procedures. (6) The water and oil resistance will be lost if the front sheet is peeled off or torn. Do not use the Counter if the front sheet is peeled or torn. 7

Operation 1. DIP Switch Settings protection and whether each counter operates as a counter or a timer are specified on a DIP switch provided on the side panel of the Counter. Open the cover of the switch compartment on the side of the Counter to access the DIP switch. DIP switch compartment Timer Counter 1 2 3 4 5 6 7 8 9 1 Enabled Disabled Protection (Can always be switched.) Note 1. Set the DIP switch (except for Protection) before turning ON the power. Changes to DIP switch settings while the Counter is operating will be ignored. Power must be turned OFF then back ON after changing the settings. Changes to DIP switch settings are also enabled when changing to initial setting mode because the same operation is performed as when cycling the power. 2. protection can be set for each key. protection will be performed based on the details set in the initial setting mode. Refer to Initial Setting Mode on page 11. 2. Changing Mode The system will always enter the RUN mode after the power supply is turned ON. Re-monitor mode SET Press for 4 s min. Normal Mode Press for 4 s min. Initial Setting Mode Refer to page 12 for information on the re-monitor mode. RUN mode This mode is for the operational state. The present value, set value, counter number, and output status will be displayed. Refer to page 11 for information on the initial setting mode. 3 2 Forecast value mode This mode is for setting forecast values. Values can be independently set for each counter number. 3 2 Pre-forecast value mode* This mode is for setting pre-forecast values. The pre-forecast will be displayed (LCD) as a value before the forecast value. Set that value as the pre-forecast value. Values can be independently set for each counter number. Set the pre-forecast value by deviation. 3 -- 5 Machine stoppage mode* This mode is for setting machine stoppage values. Machine stoppage (output/lcd) will occur at a value in excess of the forecast value. Set that value as the machine stoppage value. Values can be independently set for each counter number, but machine stoppage output will be performed if any counter from No. 1 to 9 reaches the machine stoppage value. Set the machine stoppage value by deviation. 3 1 Note: I/O operations are always performed regardless of the mode. If no key is pressed for 1 minute in each mode, the RUN mode is automatically restored. 3 will flash. The modes marked * are not provided on the 1- stage type Counter. 8

3. Setting/Changing Data Setting/Changing Forecast Value 1. In the RUN mode, press the to enter the forecast value setting mode. The same counter number as in the RUN mode is displayed after changing to forecast value mode. 2. Press the CNT No. (or turn ON the counter number selection input) to select the counter whose data is to be set or changed. The counters are selected in sequence each time the CNT No. is pressed, from 1 through 9, then back to 1. 1 2 3 4 5 6 7 8 9 A counter can also be selected by inputting the counter number selection input. 3. Use the UP s ( 1 to 6 ) to change the values of the digits. When an UP is pressed, the corresponding digit starts flashing. The preset value is zero-suppressed. Each time the UP is pressed, the value changes in sequence, from 1 2 3 4 5 6 7 8 9. 1 2 3 4 5 6 7 8 9 In the following example, the forecast value of counter 2 is set to 35. 4. Press the SET to enter the set value. If no key is pressed within 5 seconds after the SET has been pressed, RUN mode is automatically restored. (The display is changed automatically after the set forecast value has flashed.) 1 1 2 2 1 2 35 2 35 2 35 Setting and Changing Pre-forecast Values (3-stage Type) 1. Press the to enter the pre-forecast value setting mode. The same counter number as in the forecast value setting mode is displayed after changing to pre-forecast value mode. - is automatically displayed. 2. Press the CNT No. (or turn ON the counter number selection input) to select the counter whose data is to be set or changed. Next, press the UP ( 1 to 5 ) to set or change the preforecast value. The CNT No. does not need to be pressed if the counter does not need to be changed. 3. Press the SET to enter the set value. If no key is pressed within 5 seconds after the SET has been pressed, the RUN mode is automatically restored. Setting and Changing the Machine Stoppage Value (3- stage Type) 1. Press the to enter the Machine Stoppage Value setting mode. The same counter number as in the preforecast value setting mode is displayed after changing to machine stoppage value setting mode. + is automatically displayed. 2. Press the CNT No. (or turn ON the counter number selection input) to select the counter whose data is to be set or changed. Next, press the UP ( 1 to 5 ) to set or change the machine stoppage value. 2-- 2-- 1 1-- 1 2 2 25 The CNT No. does not need to be pressed if the counter does not need to be changed. 3. Press the SET to enter the set value. If no key is pressed within 5 seconds after the SET has been pressed, the RUN mode is automatically restored. 2 25 9

4. Special Set Values Setting Counters That Will Not Use the Machine Stoppage Output (3-stage Type) The machine stoppage output will not be used for counters for which the machine stoppage value has been set to +99999 (+9999.9 h/+9999.9 s). Setting Counters That Will Not Be Used Input and output operations will not occur for counters for which the forecast value has been set to (. h/. s). If the forecast value is set to (. h/. s), the pre-forecast and machine stoppage values will automatically be set to (. h/. s). Setting Counters to Be Used as Total Counters/Timers Counters can be used as total counters/ timers if the forecast value for that counter is set to 999999 (99999.9 h/ 99999.9 s). The machine stoppage output will no longer be output for that counter. When using a counter as a total counter, the forecast output for that counter when the count value changes from 999999 to will be a oneshot output of 2 ms to indicate a carry. 5. Checking Count Values (RUN Mode) Press the CNT No. (or turn ON the counter No. selection input) in RUN mode to check the count value for each 9 counter. 1 1 The counter number changes in sequence each time the CNT No. is pressed (or the input turns ON), from 1 through 9, then back to 1. 1 2 3 4 5 6 7 8 9 Note: However, any counter whose forecast value is set to (. h/. s) will be skipped. 6. Other Indicators Timer Operation Display The period on the count value display will flash while the count input is ON and the Timer is in h mode. The timer operation measures time by totaling the ON time of the count input. 7 99999 7 99999 9 8 999999 1 1 7. Deleting Count Value 1. Resetting Individual Counters (1)Press the CNT No. (or turn ON the counter number selection input) to select the counter to be reset. The counter value can be reset in all modes except initial setting mode and re-monitor mode. (2)Press the RESET (or turn ON the reset input) to reset the count value to for that counter only. 2. Resetting of All Counters at the Same Time Press and hold both the CNT No. and RESET s for 3 seconds to reset the count value for all counters to. The same operation is achieved by simultaneously turning ON the counter number selection and reset inputs for 3 seconds. 8. All Clear Press and hold the RESET and SET s for 3 seconds to reset the count values, pre-forecast values, forecast values, and machine stoppage values to for all counters. The counter number after All Clear has been executed will automatically change to 1. 9. Control Output Display The pre-forecast value, forecast, and machine stoppage status display will be as follows: Pre-forecast Values (3-stage Type) The output display for counters for which the count value has reached the pre-forecast set value will be lit. Pre-forecast values are only displayed as a message and are not output. Forecast Outputs A red indicator will light at the top of the output display section for the lit counter number and the output will turn ON. Machine Stoppage Output (3- stage Type) The entire background will alternate between red and green and the output display for the counter with a machine stoppage will flash. Note: If the pre-forecast, forecast, or machine stoppage output turns ON, the counter number display will automatically change to that number and the count value will be displayed (in RUN mode only). 1 8 1 8 1 a 1 3 2 1 9 1 1 1 1 1 11 1 1 1

1. Initial Setting Mode This mode is for setting a number of convenient functions. Normal Mode 3 2 Refer to page 8 for the normal modes. If the mode is switched to the initial setting mode during operation, operation will continue. The characters displayed in reverse video are the default settings. Press for 4 s min. count 3h 1. Max. Counting Speed Switching The max. counting speed switching for counters 8 and 9 can be changed. Press the UP to switch between 3 Hz and 5 Hz. Press the SET to enter the set value. ti rng 1 1 2. Time Rages The Timer time rages can be changed. Press the CNT No. to change the time rages. Select the counter number. Press the UP to switch between.1 h and.1 s. Press the SET to enter the set value. Note: The time unit is displayed when the counter is set to a timer on the DIP switch. short 9 3. Short Function Counter 1 inputs can be input to other counters. ex. if 5 is selected, Counter 1 inputs can be input to counters 2 to 5. Press the UP and select the number of counters for which the short function is to be enabled. 9 OFF 2 3 4 5 6 7 8 Initial Setting Mode eset on 4. RESET Protection Mode Press the SET to enter the setting. Note: The short input is read only when the power is turned ON. They are ignored if input during operation. The RESET can be protected. Press the UP and select the counter for which RESET protection is to be set. ON (ch1 to 9) ON (ch8/9) ON (ch9) OFF Press the SET to enter the setting. Note 1. The Reset of All Counters and All Clear using the RESET are disabled if the RESET Protection function is turned ON. 2. Protection function is activated by setting the Dip Switch to 1. ode off 5. Protection Mode The can be protected. Press the UP to switch between off and on. Press the SET to enter the setting. Note: Protection function is activated by setting the Dip Switch to 1. set off 6. SET Protection Mode The SET can be protected. Press the UP to switch between off and on. Press the SET to enter the setting. Note: Protection function is activated by setting the Dip Switch to 1. ultmulti off 7. Multiplication Counter Press the UP to switch between off and on. Press the SET to enter the setting. Note: A Multiplication Counter is a batch counter that increments the count of counter 9 each time the forecast value of counter 1 is reached. 11

11. Re-monitor Mode Use this mode to return to the count value before resetting if the count value is mistakenly reset. 1. In the RUN mode, hold the SET for 4 seconds min. to change to re-monitor mode. The previous values that have been reset will be displayed. Only the display changes. Internal counting operations are not affected. The counter number remains unchanged on RUN display when the mode is changed to re-monitor display. 2. Press the CNT No. (or turn ON the counter number selection input) to select the counter to be re-monitored. 1 1 1 3 2 12. Self-diagnosis Function The following displays are made when errors occur. Display Error content All I/O Countermeasure Turn OFF the power or press the e1 CPU Errors Prohibited RESET to clear the error and restore the settings and count values to the values before the error. Turn OFF the power or press the e2 Memory Errors Prohibited RESET to clear the error and return the count values for all counters to. e3 Errors Prohibited Turn OFF the power supply or press the RESET to clear key errors. 3. When the RESET is pressed (or the reset input turns ON), the re-monitor value will flash 3 times and the only the count value for that counter will be returned to the value prior to being reset. 3 2 12

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 215.7 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 215 All Right Reserved.