SUPER LED F6 120W LED Fresnel SPOTLIGHT 100/120V or 230/240V 50/60 Hz (white light, either Tungsten or Daylight balanced Correlated Color Temperature)

Similar documents
SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

INSTRUCTION MANUAL 1. INTRODUCTION

SOFT LED 4 Vari-White INSTRUCTION MANUAL

BROTHER, BROTHER & SONS

BROTHER, BROTHER & SONS

LEDONARDO 2 USER MANUAL. BROTHER, BROTHER & SONS ApS

L5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2

LED Thunder S-150 Code 1097

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

S30-RP LED Soft Light

Yoke Safety cable loop. Up Light Bulb

S30-C LED Soft Light LIGHTING - PRODUCT SPECIFICATION V1.0

ETC Quick Guide. Source Four LED Profile

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

HD/VD : Vp-p (high impedance) AUDIO IN (L/R) Stereo mini jack (M3) x 1 (Shared with DVI-D IN) 0.5 V rms

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

aorun manual V2.0 MARCH 2018

PART 1 PRODUCT (GENERAL)...1.

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

PRODUCT SPECIFICATIONS

Altman Lighting Spectra Cyc 50 Specification

DMX LED light effect with 4 lenses

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

PRODUCT SPECIFICATIONS

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

JunoScan MK-II LED scanner. user manual

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Ref. No.: LCB-48IP LED COLORUNIT 16X3W TRI DMX

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

The features shown in the following graphics may not appear on all Desire Series fixtures. LCD Power In DMX In

Image Marketing Projector 1.6

PRODUCT SPECIFICATIONS

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

aorun manual V1.0 OCTOBER 2017

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

Nila light fixtures are intended for indoor use only (unless clearly specified for outdoor use).

LED ZOOM PAR Please R ead O ver T his M anual B efore O perating T he L ight F ixture.

SHOWLINE SL PAR 155 LED LUMINAIRE SPECIFICATIONS.

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

Mini LED Pin Spot Light Model: PLS00571

192 Channel DMX Controller

Ilumipanel 36X3 IP Optic RGB

Fusion 120 Zoom. User Manual. Order code: EQLED068

LED Spot 300W. Please read this user manual before your operation

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

Stratos Duo RGB. User Manual. Order code: EQLED371

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

USER MANUAL. B-EYE Light. Please Read Over This Manual Before Operating The Light Fixture

SHOWLINE SL epar 180 LUMINAIRE SPECIFICATIONS.

180w led gobo moving USER MANUAL

Elektralite LED Cool White Dazer

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

LED MOVING HEAD LedWash. 36 x 10w RGBW 4in1 Zooming USER MANUAL. Version 1.0 beta

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

LCB-320 LED COLORS 320X10MM DMX 16SEG

Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1

Spectra Batten (Order code: LEDJ95)

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

ORDER CODE: EQLED65 USER MANUAL

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

LED IP65 Slimline Par RGBWA +UV 7x12W

MH-X50+ LED spot moving head. user manual

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

USER GUIDE IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL

Ilumipod 36 IP Optic VW

Chroma-Q Studio One 100 D

sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

minipointe is a tiny agile air cutter specifically designed to produce sharp beam and aerial effects especially in venues constrained by size.

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

Quick Reference Guide

PXL2760MW LED LCD Monitor

PLL2210MW LED Monitor

PL2410W LCD Monitor USER'S GUIDE.

AuraBeam 150 LED. User Manual KEEP THIS MANUAL FOR FUTURE NEEDS

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

USER MANUAL Table of Contents

Transcription:

SUPER LED F6 120W LED Fresnel SPOTLIGHT 100/120V or 230/240V 50/60 Hz (white light, either Tungsten or Daylight alance Correlate Color Temperature) INSTRUCTION MANUAL Manual Operate Pole Operate MANUFACTURER REPRESENTATIVE ILT Italy S.r.l. Via Cancelliera # 10a, 00041 Alano Laziale (Rome- Italy). Tel. +39/06/902901 Fax. +39/06/90231051 U.R.L.: www.esisti.it E-mail: esisti@esisti.it 1. INTRODUCTION Congratulations on your purchase of a SUPER LED F6 lighting fixture. Our commitment to Total Customer Satisfaction an our consoliate experience an leaership in esign innovation an manufacturing of lighting proucts for the professional Entertainment Inustry means you can epen upon the quality of this prouct. The SUPER LED F6 is a compact, highly efficient Fresnel lens spotlight using a LED ARRAY comine with the DE SISTI Patente optical system to optimize the photometric performances of LED ARRAYS when utilize in comination with either Fresnels or Plano Convex lenses. The Lighting Fixture is DMX Controlle an inclues a numer of parameters that can e set locally, it is equippe with either a 100/120V or a 230/240V 50/60Hz power supply for AC fee an it is availale with either Tungsten or Daylight Balance CCT. It utilizes Stanar accessories from the DE SISTI range of equivalent Fresnel Lens size, such as Barnoor, Colour Frame, Cones, scrims. This Manual is applicale to the Revise April 2n 2015 Pag 1.

2. YOKE AND ACCESSORIES ASSEMBLY SUPER LED F6 (MANUAL OPERATED) SUPER LED F6 (POLE OPERATED) 3. POWER AND DMX DAISY CHAIN The SUPER LED F6 permits oth POWER an DMX DAISY CHAIN. In fact each Fixture is respectively equippe with: For DMX: 1 XLR5 pin Panel Mount Male (DMX IN) 1 XLR5 pin Panel Mount Female (DMX OUT) For Mains Supply 1 20A Powercon NAC3MPA BLUE (POWER IN) 1 20A Powercon NAC3MPB WHITE (POWER OUT) It is recommene to Daisy Chain a Max of 10 fixtures, even if the limitations impose y DMX Stanars are for an higher q.ty of units an even if the Powercon Connections are rate for 20A max. This Manual is applicale to the Revise April 2n 2015 Pag 2.

4. SAFETY INSTRUCTIONS Professional use: This luminaire has een esigne for professional use an must e operate y qualifie personnel only. Not for resiential use. Grouning: WARNING: THIS LUMINAIRE MUST BE GROUNDED WARNING: Disconnect Power CORDS efore any maintenance work or opening the FUSE HOLDER. Risk of serious injury. Electrical connections: IMPORTANT The cores in this mains lea are colore in accorance with the following coe: Europe America Groun Green & yellow Green or green & yellow Neutral Blue White Live Brown Black In case the colors of the cores o not correspon to the colors of the connection points on your plug, please procee as follows: the green or green an yellow core must e connecte to the connection point marke with the letter E or with the symol or colore in green or in green - yellow; the lue (or white) core must e connecte to the connection point marke with the letter N or colore in lack; the rown (or lack) core must e connecte to the connection point marke with the letter L or colore in re. Working conitions Working Position Lighting fixture: Max. Tilting 90 from horizontal Amient Temperature, t a at the place of installation an Storage Humiity at the place of installation an Storage Minimum istances from inflammale surfaces Minimum 10 C, maximum +40 C 25-80% (not conensing) Top Back Sies Front 0,2 m. 0,1 m. 0,1 m. 0,75 m. The luminaire shoul never e OPERATED close to inflammale materials. The ones inicate in the aove tale are the minimum istances recommene. Other requirements for safe use are: A. Do not cover the apertures of the luminaire housing. They are essential for correct ventilation. B. Use only original accessories an spares from De Sisti Lighting. C. Before hanging the luminaire ensure that the suspension point (or the stan) is properly rate to accept the luminaire weight. D. In case of pole operate use, fit only a P.O. stirrup from De Sisti Lighting. E. A suitale seconary safety suspension evice (safety cale, chain or equivalent) must e fitte etween the suspension point an the eyelet at the front of the oy. WARNING : DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE. 5. INSTALLATION INSTRUCTIONS The following proceure shoul e aopte: Before connecting the luminaire to the electrical mains ensure that: A. Earth line is present on the power socket. B. The mains voltage is within the rate range of the luminaire (see technical ata on the rating lael) C. The front safety shiel is present an in goo conition. It consists of a Fresnel lens mae y orosilicate un-toughene glass, with a Diameter = 150 mm, thickness = 5 mm type ( 3 min ). WARNINGS : Do not operate the prouct if the amient temperature excees 40 C Provie a minimum clearance of 0,1m (4 in.) aroun fans an air vents. This Manual is applicale to the Revise April 2n 2015 Pag 3.

SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE BECOME VISIBLY DAMAGED TO SUCH AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES. THE LUMINAIRE SHALL ONLY BE USED COMPLETE WITH ITS PROTECTIVE SHIELD D. Applying power: Never connect to immer power. Install a power plug on the power cale using the following pin assigment: 1 : Neutral 2 : Live Green/Yellow : Groun - This fixture must e connecte to groun. Make sure the local power voltage is within the range specifie. If so; connect the power cale an turn the power on. E. Stan Alone operation: Using the navigation uttons an isplay reaout ( refer to the Local Menu chapter ) navigate to Manual an set the esire intensity (for aitional operations see Local Menu chapter) F. DMX operation: Connect a DMX cale Navigate to Aress moe (Ar) an set the esire aress, (refer to the Local Menu chapter). Connect to DMX controller (refer to the Channel Setting in the Local Menu chapter) an Use it. 6. LOCAL MENU PGM PORT For Firmware Upgrae FUNCTION 1 Scrolling UP / Increases value function key ENTER Select / Confirm FUNCTION 2 Scrolling DOWN / Decreases value function key Display When the push utton are not use for more than 15 secons the isplay will go OFF. It will go ON again anytime a push utton is activate. DMX Presence Shows the presence of DMX (LED lit = DMX present) DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE: The following are the BASIC FUNCTIONS an COMMANDS that are provie on the LOCAL MENU of the LED FRESNEL. The unit is provie with a USER MENU accessile instantly on the prouct. The unit has also a SERVICE MENU that is only accessile through a PASSWORD an is reserve for QUALIFIED an TRAINED PERSONNEL: 1st MENU Displaye (scrolling with the an the uttons) 2n MENU Displaye (after pressing the X that stans for ENTER) Explanation of Each MENU FUNCTION DMX ADDRESS This Function is to SET the DMX aress from 1 to 512 (Prouct is elivere with efault settingof the DMX aress at 1) Once the C001 is isplaye, act on the utton to increase the aress to the esire value. Temporary push will increment the value y 1, if the utton is kept pushe the increment on numers is getting fast. Once the esire Aress numer is accomplishe press X ( ENTER ) to make it active LOCAL DIMMING CONTROL This Function is to LOCALLY DIM the LED INTENSITY from 0 to 100% (Prouct is elivere with efault setting of the DIMMER at 0). The intensity goes in increments of 1/100% so the isplay will show 000% with the immer at 0% an FULL with the immer at 100%. Temporary push will increment the value y 1/100, if the utton is kept pushe the increment on numers is getting fast. Once the esire Lighting Level is accomplishe an it is wante to leave that level an go to other functions of the MENU, press ENTER. LOCAL OR REMOTE CONTROL SETTINGS The LED Fresnel has the facility to lock the LOCAL DIMMING SETTING an maintain it when the POWER is turne first OFF an than ON again. This allows for the LIGHT to e TUNED an FOCUSED locally an its imming level can e locke, so that for instance a system lighting a SET can e operate y a remote switch or simple rakers y TURNING POWER ON. The relevant menu to access this function is CTRL, to enter in this menu press X ( ENTER ), it is than possile to select either DMX or AUTO y acting on the or utton an than press X ( ENTER ) again. The machine is set to DMX as efault. In DMX moe: the Fixture accepts DMX control.if in this moe the local DIMMING CONTROL is SET to a level the Light ehaviour will follow the HTP (Highest Takes Preceence) moality, in other wors it will keep the local DIMMING setting until the DMX level of the specific channel will e higher, from that level onwars the DMX level will take preceence. In this conition if the DMX connection is remove, the light will keep the last level.until power is ON. It will reset an Start at 0after Power OFF an ON again. In AUTO moe: the light will ignore any DMX control. In this moe any local imming setting will e maintaine an will e automatically recalle after power off, when turning the power on again. This Manual is applicale to the Revise April 2n 2015 Pag 4.

1st MENU Displaye (scrolling with the an the uttons) 2n MENU Displaye (after pressing the X that stans for ENTER) Explanation of Each MENU FUNCTION TEMPERATURE This function Displays in real time the LED ARRAY Case temperature in C. When pressing Enter again you exit from the temperature isplay. The steay state TEMPERATURE of the ARRAY reaches approx. 55 C after many hours of continuous operation with an amient temperature of 25-30 C. The Thermal Hanling of the LED is Automatically hanle y the local electronics an the LED will operate until the ARRAY temperature reaches 80 C, that anyway is still way within the prescrie maximum nominal prescrie y the ARRAY manufacturer that is 105 C. In case the ARRAY temperature reaches 80 C the unit will automatically turn off. Even in extreme Amient temperature conitions the LED ARRAY shall never reach the 80 C limit. The aove protection threshol is there to protect the LED ARRAY from stresse working conitions in case some other failures or specially critical working conitions are causing an over-temperature. CHANNEL SETTING (RESOLUTION & FUNCTION) This Function is to set the DIMMING RESOLUTION either at 8 its or at 16 its. Once CHAN is isplaye, act on the or uttons to scroll through the following choises: 8D: 8 its resolution (the isplay will show 8D an this is the efault setting). The Fixture utilises 1 DMX Circuit for the Light Dimming, which is the BASE CIRCUIT set in the ADDRESS. 8DS: NOT ACTIVE (for future use): The foreseen function for this setting is: 8 its resolution an STROBE (the isplay will show 8DS). The Fixture will utilise 2 DMX Circuits, the BASE CIRCUIT set in the ADDRESS will e the LIGHT DIMMING an the secon circuit (BASE +1) will e the STROBE 16D: 16 its resolution (the isplay will show 16D). The Fixture utilises 2 DMX Circuits, the BASE CIRCUIT set in the ADDRESS is the Coarse Dimming, the secon Circuit (BASE +1) is the Fine Dimming. 16DS: NOT ACTIVE (for future use): The foreseen function for this setting is: 16 its resolution an STROBE (the isplay will show 16DS). The Fixture will utilise 3 DMX Circuits, the BASE CIRCUIT set in the ADDRESS will e the Coarse Dimming, the secon Circuit (BASE + 1) will e the Fine Dimming. the thir CIRCUIT (BASE + 2) will e the STROBE Of course the 16 its function is useful if the corresponing circuits on the DMX LIGHTING BOARD are also set at 16 its. WARNING: if the LED FRESNEL is set at 16 its, ut more units are having a consecutive unitary aress (for instance first fixture set at Aress 1, secon fixture set at Aress 2 an so forth, the DMX Channel controlling the Coarse Dimming of the secon unit, will also control the fine imming of the first unit. In this case it is recommene that all fixtures are set to 8 its resolution). DMX LEVEL It Shows the DMX Input level on percentage (0-99% an FULL) receive effectively from the Fixture. Press ENTER to exit this MENU. 7. CHARACTERISTICS AND PERFORMANCE DATA DESCRIPTION VALUE DESCRIPTION VALUE LED Power 120 W Protection Type IP 22 Power 141W @ 230 V (50-60 Hz) Max Housing temperature 70 C Cosumption 150W @ 120 V (50-60 Hz) DMX Data link USITT DMX512-A DMX Channels: Protection Class This prouct uses a 5-pin XLR for DMX input an output. Use a shiele ata cales. Do not overloa the aisy chain. Up to a maximum of 32 evices can e use on a single DMX chain. Specifications suject to change without notice. 1 at 8it: Dimmer 2 at 16it: Dimmer Class 1 groun connection require Weight of Fixture Weight of arnoor M.O. P.O. 7,8 kg. 9,1 kg. 4 leaf 8 leaf 0,63 kg. 0,85 kg. Weight of color frame 0,3 kg. Size of scrims & color frame Size of Barnoor ring Seat Diameter Acc.ies Diameter 187 mm. 185 mm ( 7 1/4 ) Seat Diameter Ring Diameter 192 mm. 190 mm ( 7 1/2 ) Lens iameter 150 mm. This Manual is applicale to the Revise April 2n 2015 Pag 5.

8. DIMENSIONS Dimensions: Black=mm. Re=inches Dimensions: Black=mm. Re=inches 9. PERIODIC INSPECTION & MAINTENANCE This prouct requires very little routine maintenance, if any, ut has special cleaning instructions: Disconnect fixture from power an allow it to cool for 10 min. 1. Vacuum or gently low away any ust from fan laes an grills 2. Very gently clean the LED with Isopropyl alcohol. 3. Clean the lenses with a soft amp cloth. 4. Check the conition of the safety shiel (see chapter: Installation Instructions) efore every use. 5. Check Power supply cale an DMX control cale proper conitions 10. SAFETY STANDARDS Europe: The prouct conforms the Applicale European Directives & Stanars Low Voltage Directive: 73/23/EEC (as amene y 93/68/EEC) EMC Directive: 89/336/EEC (as amene y 92/31/EEC & y 93/68/EEC) Europen Stanars:: EN 60598-2-17, EN 60598-1, EN 55015, EN 61547 Disposing of this prouct: Help preserve the environment! Ensure that this prouct is recycle at the en of its life. This prouct is in compliance with the RoHS an WEEE irectives. This Manual is applicale to the Revise April 2n 2015 Pag 6.

13 a c 11 e g f SEE SHHET 2 A h This Manual is applicale to the Revise April 2n 2015 Pag 7.

A a c A e g f B SEE SHEET 3 h This Manual is applicale to the Revise April 2n 2015 Pag 8.

n i B P.O. Focus n l m C A SEE SHEET 3 z o p z C D SEE SHEET 3 p o m l t c u v A q r s p This Manual is applicale to the Revise April 2n 2015 Pag 9.