PACS TOMO COMPATIBILITY

Similar documents
DICOM Conformance Statement

Tuesday, Dec 3rd 10:15 to 11:00 IHE Classroom at InfoRAD at RSNA 2002.

Breast Imaging Essentials

DICOM Correction Proposal

DICOM Conformance Statement. Inturis Cardio View Station R 1.1. Document Number October 1999

DICOM Conformance Statement. CD-Medical Recorder for DCI systems CDM Release Document Number July 1998

DICOM. image protocol

DICOM Correction Item

Overview. ACR Accreditation Update in Mammography. ACR Topics. Requirements Today. What s Coming For Tomorrow

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

CARESTREAM DIRECTVIEW Elite CR System

CARESTREAM DIRECTVIEW Elite CR System

Clarity and confidence. Raising the bar in diagnostic imaging with Barco radiology and mammography displays

Request for Proposals

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

IP Broadcasting System. User manual

Coronis Uniti (MDMC-12133) 12MP diagnostic display system for PACS and breast imaging

Logic Controls LV3000 VGA Connected Virtual Pole Display

Quick reference guide

Table of content. Table of content Introduction Concepts Hardware setup...4

Design and FPGA Implementation of 100Gbit/s Scrambler Architectures for OTN Protocol Chethan Kumar M 1, Praveen Kumar Y G 2, Dr. M. Z. Kurian 3.

Coronis 5MP Mammo. Online User Guide

Mammo Tomosynthesis 5MP

World First Slim Cassette Type Digital Mammo. Upgrade Solution

VIDEO GRABBER. DisplayPort. User Manual

Quick Guide Book of Sending and receiving card

Tutorial 11 ChipscopePro, ISE 10.1 and Xilinx Simulator on the Digilent Spartan-3E board

Nio. Industry-standard diagnostic display systems

CLIPSTER. 3D LUT File Generation with the Kodak Display Manager. Supplement

Configuration Vestas VMP3500

The Versatile and Powerful ACLxy. ACLxy

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

What to consider when choosing a mammography display

Safety Information. Do Not

StreamServe Persuasion SP5 StreamServe Connect for SAP - Delivery Manager

administration access control A security feature that determines who can edit the configuration settings for a given Transmitter.

AV Foundry VideoForge HDMI Digital Video Generator Quick Start Guide

Barco Healthcare. Product catalog

MultiSpec Tutorial: Visualizing Growing Degree Day (GDD) Images. In this tutorial, the MultiSpec image processing software will be used to:

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

Usage of any items from the University of Cumbria s institutional repository Insight must conform to the following fair usage guidelines.

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

CoronisUniti. User Guide MDMC ENABLING BRIGHT OUTCOMES

Coronis Fusion 6MP. User Guide MDCC-6230

Nio. Industry-standard diagnostic display systems

Multi-Channel Image. Colour of channel

Chapter 23 Dimmer monitoring

Scope: All CT staff technologist

HITS QT/QT+ Setup Instructions for QSD/QHD Services using: Drake SCT2x4 Headend Transcoder 2 Satellites/4 Multiplexes

DIAGNOSTIC IMAGING: BREAST, 2ND ED: PUBLISHED DOWNLOAD EBOOK : DIAGNOSTIC IMAGING: BREAST, 2ND ED: PUBLISHED PDF

Sky HD+ / Sky Q Module

Members QUICK REFERENCE GUIDE

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

ARRI Look Creator. Quick Guide / Release Notes for Open Beta Test v1.0

Weschler AMT Software for the Enhanced Version Transformer Advantage

USER GUIDE TO CREATE MY ÉTUDES EN FRANCE ACCOUNT AND SUBMIT MY ONLINE APPLICATION. Études en France Application Campus France process

RedRat Control User Guide

MT300 Pico Broadcaster

Remote Application Update for the RCM33xx

Radiological Imaging. Software Version 3.6

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

Vortex / VSX TM 8000 Integration

Auro 11.1 update for ICMP. Installation manual

LUT Optimization for Distributed Arithmetic-Based Block Least Mean Square Adaptive Filter

Coronis 5MP Mammo. The standard of care for digital mammography

MLA Format a Class Assignment Word points

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work?

IHE. Display Consistency Test Plan for Image Displays HIMMS and RSNA. Integrating the Healthcare Enterprise

Preparing for remote data collection at NE-CAT

Hospital Wide. Healthcare Display Solutions DICOM Displays, Large Screen Displays and Projectors

2G Video Wall Guide Just Add Power HD over IP Page1 2G VIDEO WALL GUIDE. Revised

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

USER GUIDE TO CREATE MY ÉTUDES EN FRANCE ACCOUNT AND SUBMIT MY ONLINE APPLICATION. Études en France Application Campus France process

STB-TOOL GEBRUIKER SEED ARCHITECTS AUT.SEED AUTOMATION AB.ER.MAN USER GUIDE STB-TOOL JULY 1, 2017

Satellite Radio. Expand Your Factory Radio ISSR bit & 29-bit LAN. Owner s Manual Gateway. add. Harness Connection USB. Port 1 Port.

Medical Monitor Solutions

Cyan Sample. Forward T Software. Infotainment Channel Design Sample. Revision as of January 22, 2009 г. Instruction on Installation and Use

Barco surgical displays. High-accuracy visualization solutions for surgery and endoscopy

Booya16 SDR Datasheet

5620 SERVICE AWARE MANAGER. NTP Driver Version Guide

Procedures to Characterize Maury s Automatic Tuner Using ATS Software Version 5.1 or above

AMERICA S CASTLES. 5. Be sure all four margins are set to 1 (Step 1 in the MLA Document).

TechTip. Image processing with lookup tables (LUT): Make the (almost) invisible visible. Background

Harmony Smart Control. User Guide

using the Scott A Speakman, Ph.D Center for Materials Science and Engineering at MIT

Medical Monitor Solutions

Configuring and Troubleshooting Set-Top Boxes

BoxIO User Manual Updated Applies to BoxIO Firmware Version 1.51 IP Remote Utility Version 1.0

X-Sign 2.0 User Manual

HV/PHA Adjustment (PB) Part

User Manual for ICP DAS WISE Monitoring IoT Kit -Microsoft Azure IoT Starter Kit-

APP USE USER MANUAL 2017 VERSION BASED ON WAVE TRACKING TECHNIQUE

Encoder Modulator. IPTV Setup

OM2000N INSTALLATION MANUAL

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment.

MXS Strada USER GUIDE

Recurring Events Guide

COMP2611: Computer Organization Building Sequential Logics with Logisim

User's Manual of LED LIGHTING CONTROL SYSTEM (VC-500A/B) VISS LIGHTING (SHENZHEN) CO.,LTD.

Transcription:

PACS TOMO COMPATIBILITY Documentation Control: Author Date Signature Issue F. Gigante 18-Jul-16 Approval A. Rossi 18-Jul-16

i. Document versions Version Date Author Changes 1.00 18-Jul-16 F. Gigante First Version 1.1 09-Nov-16 F. Gigante Images set link updated (Added CT and fixed patient and image orientation DICOM fields) Document Versions Page 2 of 10

ii. Table of contents I. DOCUMENT VERSIONS...2 II. TABLE OF CONTENTS...3 1 INTRODUCTION...4 2 DIGITAL BREAST TOMOSYNTHESIS IMAGE STORAGE...5 2.1 TOMOSYNTHESIS DICOM IMAGE LATERALITY CHECK...5 2.2 TOMOSYNTHESIS DICOM IMAGE POSITION CHECK...5 2.3 TOMOSYNTHESIS DICOM WINDOW LEVELS CHECK...6 2.3.1 PER FRAME WINDOW LEVELS (DEFAULT)...6 2.3.2 SHARED WINDOW LEVELS...6 3 COMPUTED TOMOGRAPHY IMAGE STORAGE...8 4 TEST IMAGES...9 Table of contents Page 3 of 10

1 Introduction IMS Giotto Tomo and Giotto Class system create the following DICOM images: SOP Class UID SOP Class Name 1.2.840.10008.5.1.4.1.1.1.2 Digital Mammography Image Storage For Presentation 1.2.840.10008.5.1.4.1.1.1.2.1 Digital Mammography Image Storage For Processing 1.2.840.10008.5.1.4.1.1.13.1.3 Breast Tomosynthesis Image Storage 1.2.840.10008.5.1.4.1.1.1 Computed Tomography Image Storage The first two sop classes are used for the standard 2D mammo images. The last two sop classes are used for the tomo multislice images and for the synthetic image (G-View). Introduction Page 4 of 10

2 Digital Breast Tomosynthesis Image Storage The tomosynthesis Breast Tomosynthesis Image Storage images have some new fields to store the DICOM information. The most often issue are present when a not compatible PACS try to read some of the following information: Image Laterality Image Position Image Window Levels Several PACS could not have a complete compatibility with tomo images: they could not correctly read the previous information. If the PACS cannot read the Image Laterality and or the Image Position, it cannot display correctly the laterality and position labels over the image and it cannot position correctly the images by mean of visualization hanging protocols. If the PACS cannot read correctly the Image Windows Levels the images will be displayed very gray, without any contrast. 2.1 Tomosynthesis DICOM Image Laterality Check The Image Laterality is store in the following DICOM field (Frame Laterality): Shared Functional Groups Sequence(5200,9229) Sequence that contains the Functional Group Macros that are shared for all frames in this SOP Instance and Concatenation > Frame Anatomy Sequence (0020,9071) Identifies anatomic characteristics of this frame >> Frame Laterality (0020,9072) Laterality of body parts. Enumerated Values: R=right, L=left 2.2 Tomosynthesis DICOM Image Position Check (0054,0220) ViewCodeSequence >Code Value (0008, 0100) According to parameters set on the Giotto console and DICOM standard Digital Breast Tomosynthesis Image Storage Page 5 of 10

>Code Scheme Designator (0008, 0102) Always SRT >Code Meaning (0008, 0104) According to DICOM standard >View Modifier Code Sequence (0054, 0222) 2 Sequence that provides modifiers for the view of the patient anatomy. 2.3 Tomosynthesis DICOM Window Levels Check The Window levels may be stored in two different way: one value per frame or one value for all the frames. The default option to store the images is one value per each frame. 2.3.1 Per frame Window Levels (default) Per-frame Functional Groups Sequence (5200,9230) Contains the Functional Group Macros corresponding to each frame of the Multi frame Image > Frame VOI LUT Sequence (0028,9132) >> Window Center (0028,1050) >> Window Width (0028,1051) >> VOI LUT Function (0028,1056) 2.3.2 Shared Window Levels It's possible to store a single couple of Window Levels value for all the frames. The shared Window Levels may improve some PACS Open Raffaello and click on the folllowing option: Tools Global Admin Settings Configuration Station Configuration Tomo Reco Settings and check the option Shared WL (see fig.1). Digital Breast Tomosynthesis Image Storage Page 6 of 10

Fig. 1: Shared WL The shared Window Levels will be stored inside the following shared sequence: Shared Functional Groups Sequence (5200,9229) > Frame VOI LUT Sequence (0028,9132) >> Window Center (0028,1050) >> Window Width (0028,1051) >> VOI LUT Function (0028,1056) Digital Breast Tomosynthesis Image Storage Page 7 of 10

3 Computed Tomography Image Storage Raffaello 4.4 can create Computed Tomography (CT) images instead of standard Digital Breast Tomosynthesis image. This approach has advantages and disadvantages: Advantages The tomo and synthetic images in CT format can be stored and displayed probably on every PACS. Disadvantages The PACS could not correctly display all the mammo information and could not use a mammo display hanging protocol. Keep in mind this issue is not present if you use Raffaello RWS 4.4 to display the tomo and synthetic images in CT format. Computed Tomography Image Storage Page 8 of 10

4 Test Images You can download the following zip file: https://drive.google.com/open?id=0b0cqzoumccfec3btc2hfvglvdws This demo set contains images in DBT format and CT format. The following positioning example are syntetic images stored as Digital Breast Tomosynthesis images (DBT): LCC, LML, LMLO, RCC, RML, RMLO The following positioning example are tomo images stored as Digital Breast Tomosynthesis images (DBT) and Computed Tomography images (CT): LCC Use all the images to verify they are correcly displayed: orientation, hanging protocol Window Level and labels. The set contains 4 tomo LCC: DBT-LCC_CANOVA.dcm is a tomo in Digital Breast tomosynthesis format (DBT) and different Window Level values per frame. DBT_L_CC_CANOVA_SharedWL.dcm is a tomo in Digital Breast tomosynthesis format (DBT) and the same Window Level value for all the frames. CT-LCC_CANOVA is folder with a LCC tomo image in Computed Tomography format (CT) and different Window Level values per frame. CT_SharedWL-LCC_CANOVA is folder with a LCC tomo image in Computed Tomography format (CT) and the same Window Level value for all the frames. Different Window Level per frame id the Raffaello default setting. Shared Window Level for all the frames is an optional setting. All the frames of the LCC with Shared WL must be displayed with the following values: Window = 6803 Level = 1674 Test Images Page 9 of 10

The first frame of the LCC with Different WL per frame must be displayed with the following values: Window = 6737 Level = 1489 The last frame of the LCC with Different WL per frame must be displayed with the following values: Window = 6869 Level = 1859 Test Images Page 10 of 10