Keysight FieldFox Microwave Analyzers

Similar documents
Agilent FieldFox RF Analyzer N9912A

Agilent CSA Spectrum Analyzer N1996A

JD725A Cable and Antenna Analyzer - Dual Port

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Advanced Test Equipment Rentals ATEC (2832)

Spectrum Master. Compact Handheld Spectrum Analyzer. Technical Data Sheet

SMS3000X Series Spectrum Analyzer

Model Three Signal Level Meter. Operation Manual

AE-366B SPECTRUM ANALYSER

RF Explorer RackPRO. User Manual. Introduction. Greetings fellow traveler on the RF spectrum.

Spike Spectrum Analyzer Software User Manual

ST-4000 SIGNAL LEVEL METER

Model Two and Model Two Lite Signal Level Meters OPERATION MANUAL

Agilent ESA Series Spectrum Analyzers

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal. Application Note

Keysight Technologies Method of Implementation (MOI) for BroadR-Reach Link Segment Tests Using E5071C ENA Option TDR

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

System Requirements SA0314 Spectrum analyzer:

CARLO GAVAZZI Automation Components

LPT-2250 Spectrum Analyzer Operation Manual

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

ST-4000D SIGNAL LEVEL METER

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

SpecMini Spectrum Analyzer. T8142 Operation Manual

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer. Application Note

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

R3267/3273 Spectrum Analyzers

AIM & THURLBY THANDAR INSTRUMENTS

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

LPT-3000 Remote User s Guide (LPT-3000R) LP Technologies

Noise Detector ND-1 Operating Manual

GC723A/GC724B. User s Manual. Cable and Antenna Analyzer.

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B. User Manual and Programming Guide

Introduction to the new software V230 for the minivna

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Keysight PXA Signal Analyzer

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

FRQM-2 Frequency Counter & RF Multimeter

Agilent 8720E Family Microwave Vector Network Analyzers

D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER. User s Guide (Please read carefully before using for the first time!)

VNA Master Model MS203xA

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

INSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017

Improving the accuracy of EMI emissions testing. James Young Rohde & Schwarz

Site PROFILER E7000L Series

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

843-R 843-R LASER POWER METER USER MANUAL. NEWPORT CORPORATION

SSA3000X Series Spectrum Analyzer

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Spectrum Analyzers. 2399A 9 khz to 3 GHz Spectrum Analyzer.

Effective Test Procedures for Installing and Maintaining RF Transmitter Sites

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

Calibrating the CMD Output Level for BER

Product Introduction. Duplexer Box MN2555A. Signal Analyzer MS2830A. Ver.1.0

ENGINEERING COMMITTEE

How To Demonstrate Improved ACLR Dynamic Range With FSU and Noise Correction

SDS1000C Specifications

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

ST800K-U Optical Power Meter. User Manual V1.0

Hand-held Design Brings Peak Performance to the Field. Optical Multimeter AQ2150A

SSA3000X Series Spectrum Analyzer

SA 1454 Signal Analyzer

Transmitter Interface Program

SNG-2150C User s Guide

RF Record & Playback MATTHIAS CHARRIOT APPLICATION ENGINEER

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

Full-featured CW Microwave Counters for Field, Factory or Lab

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

Sunrise Telecom, Hukk Division

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

ME1000 RF Circuit Design. Lab 10. Mixer Characterization using Spectrum Analyzer (SA)

Measurements on GSM Base Stations According to Rec

DS2460Q QAM Analysis Meter

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

MILLIMETER WAVE VNA MODULE BROCHURE

8821Q-R Spectrum Analyzer

RF Level Test System +20 dbm to 130 dbm

Digital Storage Oscilloscopes 2550 Series

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

DATENBLATT. SSA3000X-Serie. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Pin setup: 1 (EXC+) 2 (EXC-) 3 (SIG+) 4 (SIG-) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC)

Troubleshooting CS800/LC900 Bikes

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

LA-1440 and LA-4440 Sound Level Meter

Application Note DT-AN DTU-315 Verification of Specifications

FOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents

Vector Network Analyzers

Transcription:

Quick Reference Guide Contents Keysight FieldFox Microwave Analyzers Do you have everything?... 1 The Power Button and LED... 1 Battery Usage... 2 Measure Return Loss (CAT Mode)... 3 Measure 1-Port Cable Loss... 4 Measure Distance to Fault (CAT)... 5 Measure S-Parameters (NA Mode)... 6 Multi-Trace Configurations (NA Mode)8 Calibration (CAT, NA, VVM)... 9 Spectrum Analyzer (SA Mode)... 10 Channel Measurements (SA)... 11 Record Playback (Opt 236)... 12 Power Meter Mode... 13 Save and Recall Files... 14

Do you have everything? - - - - - - - FieldFox To check for installed options, press System then System Configuration then Options then Show Options Phase stable jumper cable or adapters Used to connect the FieldFox to devices with various connector types and gender. Attenuators Reduces power and prevents damage to the FieldFox at the RF IN port. Cal Kit OSL Tee or other calibration devices. SD card or USB flash drive Save files to these devices for quick download to a PC. USB Power Sensor For making Power Meter measurements. (Opt 302) Battery charger or extra battery The Power Button and LED - To turn power ON, briefly press the power button. The LED is green. The boot-up takes about 60 seconds. - To switch to Standby power (low battery drain) briefly press the power button. A 10 second counter is displayed that allows you to choose Standby / Shutdown / Restart or to let the countdown counter expire after 10 seconds then perform the action. The LED is green and blinks slowly. To turn power ON, briefly press the power button. Power and settings are restored instantly. - To turn Power OFF (very low battery drain) press the Shutdown softkey (For details, refer to previous Standby bullet). The LED is OFF, or solid amber, if AC power is connected. 1

Battery Usage A fully charged battery should last about four hours. Battery charge status is viewable: - In the upper-right corner of the screen. - On the battery. To view the LCD gauge on the Inspired Energy battery, open the FieldFox battery compartment door. To conserve battery power: - Use Hold (Run/Hold) mode to trigger a measurement only when needed. Hold is shown on the display. - Press System then Display then Brightness then dim the FieldFox display as much as possible. - Press the power button and press the Standby softkey when not being used. Press again to restore power. All current settings are preserved. The FieldFox will shutdown automatically when battery power is very low to prevent it from being completely discharged. Use ONLY a FieldFox charger to recharge a battery. The battery can be fully charged while in the FieldFox in about 4 hours with the FieldFox either ON or OFF. A fully discharged battery takes about 1.5 hours to recharge to 80%. The battery can be fully charged in about 4 hours using the external battery charger (Opt 872). 2

Measure Return Loss (CAT Mode) Return loss can be thought of as the absolute value of the reflected power as compared to the incident power. When measuring an OPEN or SHORT, all incident power is reflected and 0 db return loss is displayed. When measuring a LOAD, very little power is reflected and values of 40 db to 60 db are displayed. 1. Connect the Device Under Test (DUT). 2. Select Preset then Preset (Factory) Returns the FieldFox to known settings. 3. Select Mode then CAT (Cable and Antenna Test) 4. Then Meas Setup 4 then Return Loss (Default measurement). 5. Press Freq/Dist and enter Start and Stop frequency values of the measurement. 6. Press Meas Setup 4 then Settings to make appropriate settings before calibrating. 7. Disconnect the DUT and press Cal 5 then follow the calibration prompts. 8. Reconnect the DUT (cable to be tested). Optional - Add Markers All Modes except VVM and Power Meter - Add Limits All Modes except VVM and Power Meter - Save Settings and Data All Modes 3

Measure 1-Port Cable Loss (CAT Mode) Required Equipment: - LOAD with correct connector type and gender to terminate the end of the DUT. - Optional phase stable jumper cable or adapter to connect the beginning of the DUT to the FieldFox. 1. Press Preset then Preset 2. Then More then Cable Loss (1-Port) 3. Connect the DUT. 4. Press Freq/Dist and enter Start and Stop frequency values of the measurement. 5. Press Sweep 3 then Min Swp Time Increase the sweep time until a stable trace is visible on the screen. 6. Press Cal 5 then follow the calibration prompts. 7. Connect the DUT (cable to be tested) to the FieldFox and connect a LOAD at the end of the DUT. Depending on the DUT, the following three steps may improve the amount of ripple visible on the screen. 8. Press Trace 6 then Math and Memory, then Data- >Mem. 9. Remove the LOAD and leave the end of the DUT open. 10. Press Data Math then Data Mem. Use Averaging for high-loss measurements. Press BW 2 then Averaging 11. Read Avg Cable Loss on the FieldFox screen. 4

Measure Distance to Fault (CAT Mode) Required Equipment: - LOAD with correct connector type and gender to terminate the end of the DUT. - Known length and cable type or Cable Loss (db/meter) and velocity factor of the DUT. - Optional phase stable jumper cable or adapter to connect the beginning of the DUT to the FieldFox. 1. Connect any necessary jumper cable or adapter to the FieldFox RF OUT port. 2. Press Preset then Preset 3. Then Mode then CAT 4. Then Meas Setup 4 then Distance to Fault 5. Press Freq/Dist then Stop Distance and enter the length of the DUT. 6. If a diplexer or other filter is in the measurement path, press Meas Setup 4 then select Freq Mode then Bandpass. Then press Freq/Dist and manually type the Min Start Freq and Max Stop Freq frequencies. 7. Press Cal 5 and follow the Cal prompts. 8. Disconnect any components or antenna that should NOT be measured and connect a LOAD at the end of the DUT. 9. Press Meas Setup 4 then DTF Cable Specifications. 10. Either press Edit/Save/Recall Cables or enter the Velocity Factor and Cable Loss manually--using Cable Corr [Manual]--of the DUT. 11. Connect the start end of the DUT to the FieldFox. The DTF measurement is displayed. 5

Measure S-Parameters (NA Mode) S-parameter syntax is described by the following: S (out in) out = FieldFox receiver port in = FieldFox source port 1. Press Preset then Preset 2. Press then Mode then NA then choose from the following: - S11 1-port reflection measurement. - S21 2-port transmission measurement. - S12 Reverse 2-port transmission measurement. Requires the full 2-port S-parameter option. - S22 Reverse 1-port reflection measurement. Requires the full 2-port S-parameter option. OR Press Trace 6 then Num of Traces then select a Multi-trace configuration. Learn more on page 8. 3. Press Freq/Dist then either Start and Stop or Center and Freq Span to enter a frequency range for the measurement. 4. Press BW 2 then IF BW to select the IF Bandwidth for the measurement. Narrower bandwidths require more time to sweep. 5. Press Sweep 3 then Resolution to select the number of data points for the measurement. More data points requires more time to sweep. 6. Press Cal 5 to calibrate the measurement. See page 9 to learn more. Continued on following page 6

Measure S-Parameters (NA Mode) continued The following NA Mode settings can be made before or after calibrating without affecting measurement accuracy. - Press Scale/Amptd to change scale. - Autoscale Adjusts the Y-axis to comfortably fit the Min and Max amplitude of the active trace. - Autoscale All Autoscales all of the traces on the screen. Useful for multi-trace configurations. - Scale Manually enter a scale per division to view specific areas of the trace. - Ref Level Manually set the value of the reference line. - Ref Pos Manually set the position of the reference line. Values must be between 0 (TOP line) and 10 (BOTTOM line) - Press Measure 1 then Format to change the format for the measurement. - Press BW 2 then Average then enter a value for the number of trace sweeps to average. - Press Marker then enter a value to move the marker to the X-axis position of interest. - Press Limit 8 then Edit Limits or Recall Limits to test measurement results against limit lines. 7

Multi-Trace Configurations (NA Mode) You can display multiple traces on the FieldFox screen. The above image shows a 3-trace configuration. Tr1 is the ACTIVE trace as indicated by the highlighted Tr1 annotation in the upper left corner. The Frequency Range, IF BW, Resolution, Averaging, and Output power is common to all traces. All trace settings, such as format, markers, and limit lines, are applied to the ACTIVE trace in the same manner as when a single trace is present. To select a multi-trace configuration: - Press Trace 6 then Num of Traces - Then choose a multi-trace configuration. To activate a trace in order to change a setting: - Use the arrows to scroll through the traces - OR - Press Trace 6 then select Trace 1, Trace 2, Trace 3, or Trace 4, Only traces that are shown can be activated. By default with Multi-trace configurations, Markers that are applied to one trace are applied to ALL traces. 8

Calibration (CAT, NA, VVM) Calibration is performed in CAT, NA, and VVM Modes. A calibration is performed automatically when the FieldFox is powered ON, CalReady sets the reference plane at the test port connectors. For highest accuracy, perform a QuickCal or O,S,L when any of the following occur: - The temperature changes significantly. - The Frequency Range, Resolution, Min Swp Time, or Power Level is changed. - When using a phase stable jumper cable or adapter to connect the DUT to the FieldFox. These should be high-quality components. Press Cal 5 then follow the prompts. During a QuickCal 1, press Skip Load when NOT using a jumper cable or adapter. Cal Rdy is shown on the screen when a CalReady is correcting the measurement. Cal ON Q is shown on the screen when a QuickCal is correcting the measurement. CAL ON U is shown on the screen when an O,S,L Cal is correcting the measurement. When a calibration is being interpolated, an asterisk is added to the screen annotation as follows: Cal ON* 1 QuickCal does not apply to N995xA/6xA models. 9

Spectrum Analyzer (SA Mode) SA measurements require NO calibration. Check for a Compressed Measurement 1. Using a marker at the signal peak, make note of the signal power level. 2. Increase the RF Attenuation level by 5 db. - If the signal level does NOT change, then NO compression exists. This indicates that the signal is in the linear region of the receiver. - If the signal level DOES increase with more attenuation, then compression DID exist. Set the RF Attenuation value at the setting when further increases no longer result in an increase in the displayed power level. Set RF Attenuation 1. Press Preset then Preset 2. Press Mode then SA 3. Press Scale/Amptd then RF Atten - Auto RF Attenuation is set by adjusting the Ref Level. - Man Change the RF Attenuation level manually. Display up to four types of traces SA settings are applied to all traces. 1. Press Trace 6 then Trace 1,2,3,4 repeatedly to select a trace number to display. 2. Then State to select a trace type. 10

Channel Measurements (SA Mode) Optionally apply a Radio Standard which changes frequency settings, Res BW, and other relevant settings to that of the selected standard. Then change the frequency range by selecting channel numbers. 1. Press Freq/Dist then More then Radio Standard. Scroll to select the standard. 2. Then press Back. 3. Then press Unit Freq Chan. 4. If active, press Chan Direction to toggle between Uplink and Downlink frequencies. 5. Optionally, change the Channel Step size which allows you to use the arrows to increment the channel number by the specified value. 6. Then Back and Center, Start, or Stop channel. 7. Press Measure 1 then Channel Measurements and choose from the following: - Channel Power (CHP) - Measures total power over the specified Integrated BW. - Occupied Bandwidth (OBW) - Measures the power of the current frequency span and displays vertical posts between which the specified percentage of power is contained. - Adjacent Channel Power (ACPR) - Measures the power of a carrier channel and one, two, or three adjacent (offset) channels. - Tune and Listen (AM/FM) Plays potentially interfering AM or FM signals through the FieldFox speaker or headphones. 11

Record Playback (Opt 236) Allows you to record SA traces and play them back at a later time. You are allowed to change most SA settings during a recording. Setting changes are recorded along with the traces. To record a new session: Press Trace 6 then Record Playback Then New Session, Recorder Player, then Record Optionally set the following Recording Configuration: - Record Time limits record time. - Record Source choose where in the FieldFox data flow that data is recorded. RawMeas is easiest. - Record Interval sets the amount of time to wait between individual trace recordings. - Segment Count sets the number of traces to record. - FreqMaskTrigger sets the power level which will trigger a recording. To play a session: Press Recall Session select a session, press Open. Then Recorder Player then Play. Run/Hold can be used to Pause and Resume during Record or Playback. The maximum recording time is determined largely by the amount of available memory. To maximize recording time, select Storage Device then Internal or USB (flash drive) or SD Card. 12

Power Meter Mode Power Meter measurements are made using a Keysight USB Power Sensor. For a complete list of supported Keysight USB Power Sensors, visit: www.keysight.com/find/usbsensorsforfieldfox Damage levels are: - +25 dbm (320 mw) average - +33 dbm peak (2 W) <10μs - +5V Use an Attenuator between the DUT and the power sensor when measuring power levels that are higher than +20 dbm. The attenuator value can be subtracted from the measurement using Offset as follows: Select Offset - Press Scale / Amptd then Offset On Off - Then Offset Val Enter a value by which the power meter display is offset. A positive value compensates for a component with loss, such as an attenuator. Zeroing The Keysight USB Power Sensors perform internal zeroing automatically. Internal zeroing does NOT require that the power source be turned OFF. Perform external zeroing when measuring power levels below -30 dbm. During external zeroing, the power source MUST either be turned OFF or the power sensor be disconnected from the DUT. - Press Cal 5 - Then External Zero 13

Save and Recall Files Save current settings and calibration, trace data (CSV) and.s1p), or a picture of the FieldFox screen. Press Save/Recall 9 1. Then Device to set the LOCATION where the file is to be saved. Choose from the following: - Internal Saves/Recalls files to or from the FieldFox internal memory. - SD Card Saves/Recalls files to or from the mini SD card. - USB Saves/Recalls files to or from a USB Flash drive. 2. Then File Type - State Saves ALL FieldFox instrument settings and calibration for ALL Modes to an *.sta file. - Trace + State Saves the current trace (all traces in SA mode) and instrument settings to an *.sta file. - Picture (PNG) Saves the FieldFox screen to a *.png file. - Data (S1P) Saves CAT and NA Mode trace data to an *.S1P file. - Data (CSV) Saves trace data from the current mode to a *.csv file. 3. Then press Save to save the specified file type to the specified device location. 4. Press Recall to read an *.sta file into the FieldFox. 14

This information is subject to change without notice. Keysight Technologies 2012-2016 Edition 4 Print Date: January 2016 Supersedes: September 2, 2015 www.keysight.com