IPM500D. Belluno / Italy September 2015

Similar documents
HS-509 VIBRATION TRIP MODULE

WIRING INSTRUCTIONS CROP-LINK Drip Installation

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

High Performance Outdoor Test Translators

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

LARGE DIGITAL LED REAL TIME CLOCKS

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

ex 800 Series ematrix System

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

MICROPROCESSOR CALCULATION MODULE - S2000

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

PART 1: HARDWARE. Author: Vandermeerschen M. Version

DS-6400HDI-T Series Decoder

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

All the energy of your home, in an App!

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Tekna evo. innovation technology future 03

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

DX-10 tm Digital Interface User s Guide

Quick Operation Guide of LTN7700/7600 Series NVR

Installer Manual Video door entry unit with 3.5" monitor for Due Fili (Two-Wire) call system Elvox Vimar Group.

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

I N S T R U C T I O N D A T A

PulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator)

OLED THE PERFECT HIGH-RESOLUTION DISPLAY

A new generation of access control.

Blackbird 1x4 HDMI Splitter for TV Walls

Cable guide. for. High Performance Controllers and TeleControllers. Cable types and wiring guidelines

Migatronic Tig - Plasma Welding machine /Fanuc robot Interface. Adapted for RJ3 Controller: Adapted for RJ2 Controller:

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Model KT 115 Cooling incubators with thermoelectric cooling

21 Channel Light Show PWM LED Controller with Remote Control

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

User Guide Stand-Alone Metering for OptiPlant

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

Digital output modules

AB-114 / AB-202 AB-404 / AB-301 AB-T2454 Multi-room audio distribution system AB-202

Model KT 53 Cooling incubators with thermoelectric cooling

Ambiflex MF620 USER GUIDE

A MISSILE INSTRUMENTATION ENCODER

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

CULT. Connection diagram. PC Installer application. 1. General principle. 2. Overview. CULT: PC Installer application EN1.5

Filtration manager for automatic calculation of corrected differential pressure measurement in refuelling applications

DINOX&Digital&Video&Recorder&

The Art of Engineering

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

SIMATRIX NEO V2 Modular Video Matrix

Document Part Number: Copyright 2010, Corelis Inc.

Electronic Timer Control Day Astronomic Electronic Control

Signal conditioning instruments

DS-6900UDI Series Decoder

4 Wiring Brochure Wiring and installation of specific control

Transponder Reader TR22A01KNX TR22A11KNX. Product Handbook

Multi-functional safety relay modules PROTECT SRB-E

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

XNET Network Dome Camera (IDC4050IR/IDC4050F/IDC4050VR/IDC4050VF) Installation Manual

Photoelectrics Through-beam Type PA18C.T..., DC

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

2-output DALI controller

SAC6840N 2X1 Switcher USER MANUAL

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

VNS2200 Amplifier & Controller Installation Guide

Intelligent Security and Fire Ltd

DS-7204/7208/7216HVI-ST Series DVR Technical Manual

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

UNIGAS Hand-held combustion gas analyzer with 3 sensors

SCALE & WEIGHT DISPLAYS

Tebis application software

SY-HDBT-100 Extender Set

MXS Strada USER GUIDE

Design and Use of a DTV Monitoring System consisting of DVQ(M), DVMD/DVRM and DVRG

Stratos Duo RGB. User Manual. Order code: EQLED371

DS-6400HDI-T Series Decoder Features and Functions

T +31 (0) F

Stinger J4. STINGER J4 Connectivity Camera inputs 4 Monitor output 2 Alarm inputs 4 Relay outputs 1 Max frame rate Images per Second - Quad Screen

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

HVWIP-Series (HVWIP-T + HVWIP-R)

Transcription:

IPM500D Belluno / Italy September 2015

IPM500D Available from March 2016 Master/Slave Module for HVAC Applications

IPM500D Overview The IPM500D was designed to allow the creation and control of more complex circuits The idea is to have one master unit which is able to control different kinds of machines and to add more features to the regulation One master is able to control up to 10 HVAC units made with the ichill controllers It also has the possibility to connect one expansion in order to enable extended features

IPM500D Overview Main Controller Display Options IPM500D Visograph Visograph 2.0 (next step) Optional Expansions IPX106D IPX206D IPX306D Visotouch (next step)

Applications Heat pump applications: air / air air / water unit water / water unit Resources controlled per unit: single circuit: up to 4 ON\OFF compressors double circuit: 2 ON\OFF compressors per circuit IC208CX

Main Features Up to 10 slave units working together Regulation made on the average of the active units probes Proportional or neutral zone regulation Automatic defrost synchronization Possibility to have a back up unit Whole system information in one screen

Example of Application RS485 line ADR 1 ADR 3 ADR 2 ADR 3 UTILITIES The units work as a single machine The regulation is made on the average of the single units probes

Additional Functions with Expansion Modules Regulation made with the expansion probes Up to 3 On\Off water pumps management Up to 2 flow swicthes and 1 pressure switch configurable Power limiter function Power overboost function Changeover function through digital input

Example of Application RS485 line ADR 1 CAN bus ADR 3 ADR 2 ADR 3 UTILITIES P1 P2 P3 The expansion can manage water pumps, flow switches and pressure switch The regulation can be done with the average of the single units probes or with the expansion probes

Back-Up Unit Functionality One of the units can be set as a back-up unit. This unit will start working when: Another unit is in alarm (to compensate the active power steps number) To perform the units rotations (to extend the units life) To erogate extra power when needed (overboost function) Units Back up UTILITIES Unit in Alarm UTILITIES 4 units + 1 Back Up unit 4 units active + 1 in alarm

Overboost Function The overboost functionality allows the system to reach the Set Point faster There is the possibility to enable the function manually or with a time delay Without overboost T T Set Point Set Point Bk Unit Unit 4 Unit 3 Unit 2 Unit 1 t Bk Unit Unit 4 Unit 3 Unit 2 Unit 1 Δt t The power supplied is not enough to reach the set point in time The back up unit supplies extra power to reach the set point

Limiter Function The limiter functionality allows the system to limit the power usage There is the possibility to enable the function manually or through time bands { 21:00 } Time band 1 03:00 50% { 03:00 } Time band 2 06:00 75% { 12:00 } Time band 3 15:00 25% Outside Time bands 100% Max Power Supplied 100% 75% 50% 25% 0% Power consumption limit = Saving energy and money 00:00 03:00 06:00 09:00 12:00 15:00 18:00 21:00 00:00 Time Bands

Extra Features Wizmate supports the programming of the master and the slaves Possibility to develop custom web pages for a master web interface

IPM500D Connections Terminal Reference Description 1 Supply Reference - /GND power (24Vac or 24Vdc) 2 Supply Reference + power supply (24Vac or 24Vdc) 3 Disp. VNR Connection for VISOGRAPH remote terminal (Vnr) 4 Disp. + Connection for VISOGRAPH remote terminal (+) 5 Disp. Connection for VISOGRAPH remote terminal (-) 6 485 RS485 Slave connection (-) 7 485 + RS485 Slave connection (+) 8 S.Port RS485 MASTER Connection (-) Connectors Reference Description 9 S.Port + RS485 MASTER Connection (+) Ethernet USB Ethernet connector USB stick connector 10 Can CANBUS connection (-) 11 Can + CANBUS connection (+)

IPX106D Connections Term. Ref. Description Term. Ref. Description 1 Supply Reference - /GND power (24Vac or 24Vdc) 2 Pb1 Configurable analogue input 1 25 GND 3 Pn2 4 Pb3 5 Pb4 6 Pb5 7 +12V Configurable analogue input 2 Configurable analogue input 3 Configurable analogue input 4 Configurable analogue input 5 +12Vdc reference for analogue inputs supply 24 Pb6 Configurable analogue input 6 26 +12V 27 +5V GND reference for analogue outputs +12Vdc reference for analogue inputs supply +5Vdc reference for analogue inputs supply 28 PbC Common analogue inputs 29 Pb7 Configurable analogue input 7 30 CAN + CAN Bus connection (+), 8 +12V Additional power +12Vdc 32 CAN CAN Bus connection (-), 9 Supply Reference + power supply (24Vac or 24Vdc) 33 CAN gnd CAN Bus connection (gnd) 10 DI1 Digital input 1 35 LAN + LAN connection (+) 11 DI2 Digital input 2 36 LAN LAN connection (-) 12 DI3 Digital input 3 40 RL4 Relay 4 no contact 13 DIC Common digital inputs 41 RL5 Relay 5 no contact 14 PbC Common analogue inputs 42 RL6 Relay 6 no contact 15 GND 16 +5V 20 GND GND reference for analogue inputs supply +5Vdc reference for analogue inputs supply GND reference for analogue outputs 43 C 44 C Common for relays 5, 6 and 3 (MAX 6A) Common for relays 1, 2 and 4 (MAX 6A) 45 RL1 Relay 1 no contact 21 Out1 Analogue output 1 0-10V 46 RL2 Relay 2 no contact 22 Out2 Analogue output 2 0-10V 47 RL3 Relay 3 no contact 23 Out3 Analogue output 3 0-10V

IPX206D-IPX306D Connections Term. Ref. Description Term. Ref. Description 1 Supply Reference - /GND power (24Vac or 24Vdc) 25 GND 2 Pb1 Configurable analogue input 1 26 +12V 3 Pn2 4 Pb3 5 Pb4 6 Pb5 7 +12V Configurable analogue input 2 Configurable analogue input 3 Configurable analogue input 4 Configurable analogue input 5 +12Vdc reference for analogue inputs supply 27 +5V GND reference for analogue outputs +12Vdc reference for analogue inputs supply +5Vdc reference for analogue inputs supply 28 PbC Common analogue inputs 29 Pb7 Configurable analogue input 7 30 CAN + CAN Bus connection (+), 32 CAN CAN Bus connection (-), 8 ID Common digital inputs line contact 33 CAN gnd CAN Bus connection (gnd) 9 Supply Reference + power supply (24Vac or 24Vdc) 35 LAN + LAN connection (+) 10 DI1 Digital input 1 36 LAN LAN connection (-) 11 DI2 Digital input 2 60 RL1 Relay 1 no contact 12 DI3 Digital input 3 61 C Common for relays 1 and 2 13 DIC Common digital inputs free voltage 62 RL2 Relay 2 no contact 14 PbC Common analogue inputs 63 RL3 Relay 3 no contact 15 GND 16 +5V 20 GND GND reference for analogue inputs supply +5Vdc reference for analogue inputs supply GND reference for analogue outputs 64 C Common for relays 3 and 4 65 RL4 Relay 4 no contact 66 C Common for relay 5 21 Out1 Analogue output 1 0-10V 67 RL5 Relay 5 no contact 22 Out2 Analogue output 2 0-10V 69 RL6 Relay 6 nc contact 23 Out3 Analogue output 3 0-10V 70 RL6 Relay 6 no contact 24 Pb6 Configurable analogue input 6 71 C Common for relay 6

Generic Connection Scheme Monitoring network RS485 network

Thank you! Dixell reserves the right to alter its products without notice. All rights reserved. Because environmental conditions are outside of Dixell s control, we cannot assume liability for results obtained or any damages which may occur due to improper application.