User Manual. dcss/dscr Multiswitch 9733PL 9734PL

Similar documents
User Manual. dcss/dscr Multiswitch 9732

User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

User Manual. HDMI Modulator Ref & SW Release

DMOD1200MS. HDMI Modulator. User Manual PLEASE READ THE MANUAL COMPLETELY BEFORE USE V.17.09

User Manual. Profiler Revolution Ref PATENT PENDING. SW Version 1.3.0

UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

user manual Colosseum 8500D

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

Multi Channel Programmable Filter-Equalizer. Use Manual. Digital. Terrestrial. Ref. : 6505

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

User Manual. UNIVERSE Ref. 8600

User Guide. TMDS 5x C Digital SCR Multiswitch for SkyQ. Version B Date 02/2016 EN TMDS 54 C TMDS 58 C

Satellite B or D. Satellite Inputs (LNB Trunk)

User Manual. UNIVERSE Ref. 8600

User Manual PROHDMI STREAMER/MODULATOR. Ref /

Installation location

Single cable multiswich programmer PC102W

Operating Instructions

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

Operating Instructions

User Manual. UNIVERSE Ref SW Release

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

User guide. Stand alone Multiswitches SMC Cascadable Multiswitches SMU Amplifiers. Multiswitches

HDMI 1-in 1-out Extender via CAT-5e/ CAT-6

Operating Instructions

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

LINK EXT40-4KUHD 4:4:4 HDR HDBaseT Extender. User Manual. Version: V1.0.1

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

HDMI Converter. Operating Instructions(P/N of this Instructions is INSYH0101)

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP0108)

presents : Single Transmod Ref. 8600

Grandbeing. HDMI Splitter(Asynchronous Switching Method) Operating Instructions(P/N of this Instructions is INSGB07SW0102)

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP )

Grandbeing. HDMI Matrix. Operating Instructions(P/N of this Instructions is INSMX0404-HH1) FEATURES

Grandbeing. HDMI Converter. Operating Instructions(P/N of this Instructions is INSSH S) FEATURES

Vision EV5-D2, EV5-D4 multi-switch installation

ZVOX AccuVoice TV Speaker MODEL AV150.

User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

MAX T200 HD QUICK INSTALLATION GUIDE

HDBaseT Extender Over Single Cat5e/6 cable

Utility Amplifier GA6A Model

Grandbeing. HDMI Matrix (Router Type) Features

Grandbeing. HDMI Extender (By CAT-5E/6 cable) Operating Instructions(P/N of this Instructions is INSEX0101-U30/U31) FEATURES

Operating Instructions

SAT IF distribution system

4KEX70-L. HDBase-T Lite Extender. User Manual

PRODUCT MANUAL : 1x8 Splitter/Extender : Receiver (Sold Separately)


Grandbeing. HDMI Convertor. Operating Instructions(P/N of this Instructions is INSMS A) FEATURES

MX-DIGITAL COAXIAL CONVERTER MX-1226

Bring High-Definition to your life!

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

Register your product and get support at SDV5122/27. EN User manual

Unicable II Cascadable switch with Terrestrial input and 4x Sky dscr/satcr/legacy+terrestrial outputs

a Quick Guide Triax Multi Switches

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

ZVOX AccuVoice TV Speaker Model AV203

ZVOX AccuVoice TV Speaker Model AV203


IMPORTANT SAFETY INSTRUCTIONS

Unicable II Programmable/cascadable multiswitch with 32 User Bands, 4 Universal/Wideband Satellite inputs & 1 Terrestrial input

HDTV Supply. Mega Scaler. Operating Instructions FEATURES

User Manual CS-HDBTLPOER m HDBaseT Extender with Bi-directional PoE. Version: V1.0.0

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

Installation Manual VIP 1003

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

L-BAND over Fiber Link TX/RX. User Manual. L-1Ch-L-Band-TX/RX

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

DisplayPort Extender over 2 LC Fibers

2.0 Wall Mount TV Soundbar Instruction Manual

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

CM-S23349SV. Vari-Focal IR Bullet Camera

Outdoor IR Audio Camera

HOME THEATER. Super IR Accessories. Vanco Part Numbers. Technical Support

Bring High-Definition to your life!

HOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support

OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

DisplayPort Extender over 2 LC Fibers

CM-S38901SV TVL IR Long Range camera

Model 1606 Super. User Manual

w w w.w h y t e t e c h n o l o g i e s.c o m.

QCA9-33 Active Combiner

V TV / SATELLITE DC Power Tester

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

since 1962 CATALOGUE English version

FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

HDMI to Composite / S-Video. Audio. Scaler GTV-HDMI-2-COMPSVIDN. User Manual. Release A3

2x1 HDMI SWITCH. with Multiview and PIP Vanco Part Number: EVSW21MV

Extender w/ RS-232 and 2-way IR

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

CPH-10 SUBWOOFER OWNERS MANUAL

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

SAT IF distribution technologies. Multiswitches and single cable multiswitches for 1, 2, 3 or 4 SAT positions

TS2.8 Sub OWNER S MANUAL

TSM 1000 HD-C TSM 1000 HD-CF

QDA4-44 RF Amp/Combiner

Transcription:

User Manual dcss/dscr Multiswitch 9733PL 9734PL

CONTENTS 1. INSTALLATION OF THE HARDWARE... 3 1.1. Quattro LNB... 3 1.2. Wideband LNB s... 4 2. CONFIGURATION OF THE MODULE... 5 2.1. Input : Quattro versus Wideband... 5 2.2. Output: Legacy versus dscr... 7 EN50494/SCR standard (DiSEqC 1.0)... 7 EN50607/dCSS/dSCR standard (DiSEqC 2.0)... 7 CONCURRENT EN50494/EN50607 standards... 7 2.3. DC Power... 8 3. TECHNICAL SPECIFICATIONS... 9 4. SAFETY INSTRUCTIONS... 11 5. CONDITIONS OF WARRANTY... 12 No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language without permission. Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time. Unitron cannot be held liable for any damages resulting from the use of this product. Specifications are subject to change without notice. 2/17 Unitron - Frankrijklaan 27 - B-8970 Poperinge - Belgium T +32 57 33 33 63 F +32 57 33 45 24 email sales@unitrongroup.com www.unitrongroup.com 2

1. INSTALLATION OF THE HARDWARE 1.1. Quattro LNB 3

1.2. Wideband LNB s 4

2. CONFIGURATION OF THE MODULE The 9733PL/9734PL are extremely versatile products, both on the input side as well as on the output side. Schematically the units support the following modes and applications: Inputs Quattro Wideband Outputs Legacy Universal multiswitch Wideband 2 quad convertor dscr/scr dscr multiswitch Wideband dscr multiswitch 2.1. Input : Quattro versus Wideband The input connections of the product can be configured in Quattro mode and in Wideband mode. When using Quattro LNBs, the switch on the right side of each 9733PL/9734PL should be set in the upper position (Quattro LNB). The 9733PL/9734PL will then expect to receive on each of the 4 inputs a satellite signal from 950 to 2150MHz. See picture on page 3 for a typical setup. In this mode, a quad LNB can also be used, but then an extra product will need to set the 4 polarities of the LNB to match the VL HL VH HH inputs of the 9733PL/9734PL. This can be done by using the Johansson ref 9930. When using wideband LNBs, the switch on each 9733PL/9734PL should be set in the lower position (Wideband LNB). In this case, wideband satellite signals from 290 to 2340MHz should be used. See picture on page 4 for a typical setup. In this mode, up to 2 wideband LNBs can be connected, allowing to receive the complete signals from 2 orbital positions. The left wideband inputs V-H are the DiSEqC LNB A position, the right V-H inputs are the DiSEqC LNB B position. Note: when using the product in wideband mode, the product will automatically make the translation between the incoming frequency and the outgoing frequency. If for instance an STB tunes into the HH band, the product will convert the incoming horizontal section 1290-2340MHz into an output range of 1100-2150MHz. 5

The same is valid when using the product as a Wideband dscr multiswitch. If the STB tunes into for instance VL 1000MHz, the multiswitch will take the incoming vertical transponder at 340MHz. The diagram above shows the basic frequency relation between wideband satellite frequencies and the standard legacy satellite frequencies. Below is the relation between the STB tuned transponder and the wideband incoming transponder frequency. In both the Quattro and Wideband mode, the 9733PL/9734PL will allow powering the LNBs on both vertical trunks lines (see chapter 2.3 DC Power for more details on how to power the units and the LNB). 6

2.2. Output: Legacy versus dscr Independent of the selected input mode, the outputs can support legacy and SCR/dSCR STBs. At startup, the unit works in Legacy mode and can be used as a universal multiswitch or wideband2quad convertor, depending on the position of the switch. Upon receiving the first dscr command, the unit will automatically switch into dscr mode in which it supports the following standards: EN50494/SCR standard (DiSEqC 1.0) STB s that only support EN50494 will only be able to use the first 8 userbands. EN50607/dCSS/dSCR standard (DiSEqC 2.0) STBs that support the newer EN50607 will be able to use all userbands (UB1 UB25 for 9733PL and UB1 UB16 for 9734PL). This is typically for new multi-tuner STBs. CONCURRENT EN50494/EN50607 standards For upgrading existing SCR installations where the main STB is upgraded to Next Gen PVR, the dscr multiswitch can support both standards simultaneously. In this case a mix of STBs can be supported: The existing STBs will use UB1 through UB8 The new main STB will use UB1 through UB25 for 9733PL and UB1 through UB16 for 9734PL In this case DiSEqC 1.0 and DiSEqC 2.0 will be used over the same cable from LNB to the apartment For an overview, please see the table in chapter 3: Technical Specifications. To return back to legacy mode, that output has to be reset. This can be done by removing the DC from the STB output connector. In case of the 9734PL, the 2 outputs are independent, so resetting (= unpowering) 1 output does not affect the other output. 7

2.3. DC Power Powering the units can be done in 2 ways: 1. From STBs : each STB has to power its connected unit. In this case, the LNB itself will not be powered from the 9733PL/9734PL and has to be done from another power source. 2. From the trunk lines : all of the cascaded dscr multiswitches can take DC power from the trunklines. Adding DC on trunks can be done by using a power insertor (Ref 9669) and a powersupply (Ref 2460) on 1 of the vertical trunk lines. See chapter 1 on hardware installation for a typical example. This setup will also power the LNB and the trunk amplifiers. A powersupply (Ref 2460) is designed to power up to 6 of these dscr multiswitches in cascade. When connecting more than 6 dscr multiswitches, it is adviced to add more powersupplies. Block diagram of the DC paths inside the 9734PL (the 9733PL is similar with only 1 STB output): 8

3. TECHNICAL SPECIFICATIONS 9733PL 9734PL Trunk inputs - 4+1 Trunk outputs - 4+1 Trunk Frequency (MHz) - 5 862 / 290 2340 STB Output Frequency (MHz) - 5 862 / 950 2150 Trunk loss - 2.5 / 2 db dcss/dscr outputs - 1 2 dcss/dscr output connector - 75 Ohm F type (Female) dcss/dscr UBs - 25 16+16 dcss/dscr output level - 85 dbµv Return loss - >=8 db (Typ 12 db) Tap loss - Not applicable, AGC (automatic Gain control) Terrestrial/Cable loss - -7 db -11 db Band and polarity selection - Universal LNB voltage & Tone DiSEqC 1.0 (unidirectional) DiSEqC 2.0 (bidirectional) Standard EN 50494 (SCD) Standard EN 50607 (SCD 2) Max DC current consumption - < 320mA @ 13 Volt < 350mA @ 13 Volt Power supply - From STB, power inserter or trunk (VL&VH) Power (2460+9669 available separately) - 3A max, 20V Dimensions - 92x90x40 mm 9

9733PL 9734PL EN50607 EN50494 EN50607 EN50494 UB FREQ UB FREQ UB FREQ UB FREQ 1 1210 1 1210 1 1210 1 1210 2 1420 2 1420 2 1420 2 1420 3 1680 3 1680 3 1680 3 1680 4 2040 4 2040 4 2040 4 2040 5 978 5 978 5 978 5 978 6 1028 6 1028 6 1028 6 1028 7 1072 7 1072 7 1072 7 1072 8 1116 8 1116 8 1116 8 1116 9 1160 9 1160 10 1271 10 1271 11 1315 11 1315 12 1359 12 1359 13 1484 13 1484 14 1528 14 1528 15 1572 15 1572 16 1616 16 1616 17 2084 18 2128 19 1816 20 1860 21 1904 22 1948 23 1992 24 1728 25 1772 10

4. SAFETY INSTRUCTIONS Read these instructions carefully before connecting the unit To prevent fire, short circuit or shock hazard: Do not expose the unit to rain or moisture. Install the unit in a dry location without infiltration or condensation of water. Do not expose it to dripping or splashing. Do not place objects filled with liquids, such as vases, on the apparatus. If any liquid should accidentally fall into the cabinet, disconnect the power plug. To avoid any risk of overheating: Install the unit in a well aery location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation Do not place any items such as newspapers, table-cloths, curtains, on the unit that might cover the ventilation holes. Do not place any naked flame sources, such as lighted candles, on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climates (not in tropical climates) Respect the minimum and maximum temperature specifications To avoid any risk of electrical shocks: Connect apparatus only to socket with protective earth connection. The mains plug shall remain readily operable Pull out power plug to make the different connections of cables To avoid electrical shock, do not open the housing of adapter. Maintenance Only use a dry soft cloth to clean the cabinet. Do not use solvent For repairing and servicing refer to qualified personnel. Dispose according your local authority s recycling processes 11

5. CONDITIONS OF WARRANTY Unitron N.V. warrants the product as being free from defects in material and workmanship for a period of 24 months starting from the date of production indicated on it. See note below. If during this period of warranty the product proves defective, under normal use, due to defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace the product. Return the product to your local dealer for reparation THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM: Misuse or use of the product out of its specifications. Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non-suitable accessories (power supply, adapters...). Installation in a defect system. External cause beyond the control of Unitron N.V. such as drop, accidents, lightning, water, fire, improper ventilation THE WARRANTY IS NOT APPLIED IF Production date or serial number on the product is illegible, altered, deleted or removed. The product has been opened or repaired by a non-authorized person. NOTE Date of production can be found in the product s serial number code. The format will either be YEAR W WEEK (e.g., 2016W01 = year 2016 week 1) or YYWW (e.g., 1447 = year 2014 week 47). UNITRON NV Frankrijklaan 27 B-8970 Poperinge Belgium T +32 57 33 33 63 F +32 57 33 45 24 sales@unitrongroup.com www.unitrongroup.com 12