USER'S GUIDE TO THE FHP2P01

Similar documents
OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

OpticalProducts. Illuminating Your Network. Testing the World s Networks

ST800K-U Optical Power Meter. User Manual V1.0

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

OTS-300 Express Series Power Meters/Sources and Testers

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Fiber tester. Optical power meter XL-FM141. Optical power meter User s Manual

Fiber Meter. Specification & User Manual

Compact live fiber identifier with integrated optical power meter

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

Light Source. Specification & User Manual

ED5229GT-E Series. Page 1 of 8

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

LTS-1500 Fiber Optic Test Set Operating Instructions

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

ED5229GT-E/GTRE Series

Options: - Master Patchcord - Launch cable - Set of optical adapters

OPTICAL POWER METER WITH SMART DETECTOR HEAD

SM-10 SAT Level Meter User s Manual

XCOM1002JE (8602JE) Optical Receiver Manual

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE

PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions. Quality Fiber Optic Test Equipment

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

User's Guide to the PROLITE-30B

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Four-way Return Optical Receiver Manual. Transmitter OP-OR124RJ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 1)

Agilent FieldFox RF Analyzer N9912A

LAN Network Tester. Operating Manual. Part No TRIAX - your ultimate connection

Datasheet: SimpliFiber Pro

POL-200 Semiautomatic Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Yellow Frog. Manual Version 1.1

CVM-WM300. UHF Wireless Microphone USER MANUAL

Weighing Scale. 10key&12key User manual

Keysight FieldFox Microwave Analyzers

2 GENERAL DESCRIPTION

LAN Network Tester LAN Network Tester

HOME GUARD USER MANUAL

OFI Optical Fiber Identifier User s Guide

H5000 Outdoor Mini Virtual HUB

Fiber Optic. Foreword. Special Tips:

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

Hand-held Design Brings Peak Performance to the Field. Optical Multimeter AQ2150A

Color Star Advanced Talking Color Identifier Light Detector and Light Analyzer

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

HDCVI Video Converter. User s Manual V1.0.0

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

Technical description and user manual. Survey Meter SM 8 D. Sensortechnik und Elektronik Pockau GmbH. Siedlungsstraße 5-7 D Pockau-Lengefeld

USER MANUEL. SNIPE 2 Ref R13

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

USER MANUAL. EMF Meter. Model EMF510. Additional User Manual Translations available at

DS2460Q QAM Analysis Meter

U SER S G UIDE. TS2002A Fiber Optic Test Kit

Operating Instructions

HD-CM HORIZON DIGITAL CABLE METER

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

2.4GHz Digital Wireless Video Door Phone User Manual

Innovations in PON Cost Reduction

Owner s Manual. Sat-Meter MSK 15. Order No.:

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

PROMAX NEWSLETTER Nº 25. Ready to unveil it?

Operating Instructions

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

MODEL:NF-300. Your excellent helper in cable test! VER: V2. Your excellent helper in cable test! ORIGINAL AUTHENTIC

2nd Edition. Quick Start Guide. getawair.com

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Optical Channel Analyzer

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

KVE vector Vector Impedance Antenna analyzer User's Manual ( V for Kve60C and Kve520A )

Platinum Tools Inc. All rights reserved. 5/12 Voice, Data, Video + Length GENERAL SPECIFICATIONS WARNINGS

Reflecta Super 8 Scanner. User Manual

3.5 TFT LCD CCTV Service Viewer with Wristband

Wire Fault Locator MODEL:NF-300 SHENZHEN NOYAFA ELECTRONIC CO.,LTD REV1.0. Your excellent helper in cable test! Your excellent helper in cable test!

Fiber Optic Meter Fiber Optic Source

OLP-34/-35/-38 Optical Power Meter. Operating Manual BN 2302/ English

User s Manual of Signal Level Meter TABLE OF CONTENTS

MTS/T-BERD 8000 Platform

PRINCIPLES AND APPLICATIONS

Sidelighter TM Optical distance to fault measurement module

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

June/July 2016 Med Tips

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

INSTRUCTION MANUAL LANTESTLCD76-SONDA REV1.0

Ethernet Media Converters

C-band Wavelength Plan for 10G EPON Downstream

Owner's Manual. TOUCH SCREEN CONTROLLER for Air Conditioning Control System. Model BMS-CT5120UL. English

CFM/CMM Thermo Anemometer

Philips CoralCare FAQ

Product Operation Manual

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Chapter 2: Scanner Operations NOTE: Install the software cartridge Power the Scanner Select the software title Identify the vehicle

It can eliminate the internet connect failure caused by user s Modem faults.

UNDER TABLE 4X1 HDMI SWITCHER

RQflex 10. Manual English

Transcription:

USER'S GUIDE TO THE FHP2P01 PON Power Meter FHP2P01 English Version

USER'S GUIDE TO THE FHP2P01 PON Power Meter

DELETE >2s CW/Burst FHP2P01 General Description: P th P/F dbm/db >2s SAVE >2s SET LOAD REF FHP2P01 PON POWER METER FHP2P01 PON power meter is a small size, low loss and good quality handed-held optical power meter. It is designed for the testing, installation and maintenance of FTTX PON network, which can be used for APON, BPON, EPON and GPON network. FHP2P01 has two output ports for ONU and OLT/Video, which supports CW/burst upstream detection at 1310nm and downstream signal at 1490/ 1550nm. It can directly show the status of pass, warning or failure by threshold testing. FHP2P01 is the ideal tool for PON setting and maintenance. 1

Main features: Handed-held, Easy-to-carry and use P/F testing and normal testing mode Two testing ports with " ONU " & " OLT/Video " Support 1310nm upstream CW/brust signal and 1490nm /1550nm downstream signal Design for networks of APON, BPON,EPON and GPON Threshold programmable Huge data storage capability USB integrated Built-in Battery charger 2pcs of AAA battery as power supply provided Software for communicating with upper-computer 2

Technical Parameters: Wavelength Linearity Isolation Rate Measuring Range (dbm) Insertion Loss(dB) Spectral Width Accuracy Threshold Data storage Accessories adaptors 11310nm (Burst) 1310nm (CW) 1490 nm 1550 nm ± 0.2@1550-40dBm >40@1490nm >40@1310nm >40@1550nm >30@1550nm >30@1490nm -30~+16-40~+16-50~+16 1.5 1260~1360 1480~1500 1539~1565 0.5db ± 1nW @ 1550 nm 10groups(configure via PC-software) 900 SC/PC(standard) ST/PC,FC/PC (Optional) 3

>2s SAVE >2s SET DELETE >2s CW/Burst FHP2P01 Structure P th P/F dbm/db LOAD REF FHP2P01 PON POWER METER Num. 1 2 3 4 5 6 Description Fiber port display Control panel Battery cover Charger jack USB port 4

Buttons of this meter have secondary function, normal push to use the function which indicated on the button, hold(>2s)to use the function on the panel, all the functions have been listed as follow: 1 Power button. Hold(>2s)to turn off the function of auto-shut down. 2 P/F Measuring mode select button. Able to switch between normal measurement and P/F measurement under main mode.during checking threshold setting and saved data it's used to turn page up. 3 >2s SAVE LOAD Data Storage button. In main mode, Hold(>2s)to storage value of current optical power.use this button to quit during checking threshold. DELETE P th P/F >2s SAVE >2s SET LOAD REF dbm/db >2s CW/Burst 4 >2s SET REF In man mode. Short press to view the current value of REF: hold (>2s)to storage current power value as reference value. FHP2P01 PON POWER METER 5 DELETE Unit change button. Used to switch between dbm and db. Hold(>2s)to erase dbm/db all the storage data..use this button to quit during checking threshold. 6 >2s CW/Burst Backlight button. to open/close backlight. In main mode Hold(>2s)to swith between 1310CW and 1301Burst. 7 P th View and select value of threshold, use "P/F" button or "REF" button to page up or page down. 5

Procedure Simple Procedure 1) Connect to the measuring circuit before use; 2) Push power button to enter measuring interface; 3) Push backlight button to turn on or turn off backlight; 4) Hold backlight button to switch between 1310nm CW/burst signal; 5) Push "Pth" button to enter interface of threshold setting and resetting, set threshold by software through USB, push "dbm/db" button to quit threshold setting interface; 6) Hold "LOAD"button to save current optical power; 7) Measurement finished, Push power button to shut down; Detailed Procedure 1. Turn on and turn off Connect power source properly, turn on the meter, after one "beep" meter will turn on and enter measuring interface automatically, showed as the right picture: 6

Hold this button(>25)will turn off the function of auto-shut down, showed as right picture, otherwise lower right corner will show "Auto-off"icon to mention you in the state of auto-shut down.auto-shut down means if user did nothing in one period of time,meter will turn off automatically, this value can set by manufacturer, default setting is 10 minutes. Please turn off the meter by power button after use so as to save power.ve power. 2. Select measuring mode Default mode is normal measuring mode,push mode select button "P/F" to switch between normal measuring mode and P/F measuring mode. Normal measuring mode Right picture is normal measuring mode. normal measuring mode can measure the optical power directly with no threshold setting. There is two way to show the value of power: with unit of dbm or db.two unit could check and switch by "dbm/db" button. During measurement of 1310nm (ONT), hold(>2s) to switch between 1310nm (CW/burst) measuring mode. -21.29 dbm 7

P/F measuring mode In P/F measuring mode meter will compare the optical power with threshold to judge whether measured power value is meet the requirement of user. Display will show the relevant judge of result :"Pass", "Warning" or "Fail". 3. Threshold setting User could set threshold, maximum 10 groups Operate as follow: In the main interface, check the value of threshold by threshold checking button, left side display 1310nm,1490nm and 1550nm. Middle is the setted threshold, right sider is unit and status. After entering threshold checking mode, continue to push the button to switch and check set point between "Fail", "Warning"and"Pass" separately. Push page up or page down button to check each threshold. The "Threshold"below the display indicate the sequence of threshold value, Threshold 0 is the first group, right picture showed the setting of third threshold value Note: Threshold setting needs specific software, detailed procedure please check the manual for software, push data storage button or unit switch button to quit this mode after use. -21.30 dbm Fail Fail Fail -10.00 dbm Fail dbm Fail -23. 01-10.00 dbm Threshold 2 Fail 8

4. Unit conversion In normal measuring mode, result could displayed with unit of dbm and db, switch between dbm and db by "dbm/db button, then display will indicate relevant unit(dbm or db),showed as right picture. "dbm" is the real optical power of the measurement, "db"is te value of optical power which compared with the REF value, about detail please check "Setting of REF value". So "dbm" and "db" are quite different, please pay more attention when reading values. In the P/F measuring mode,the same way as normal measuring mode,they also have "dbm" and "db" they have the same meaning as that in normal measuring mode. 5. Set 1310nm CW/Brust measuring mode There are 1310nm(ONT) upstream signal and 1490nm downstream(olt), 1550nm(Video)signal in the PON network, but 1310nm signal has two kinds of outputting(cw/burst). -21.29 dbm -21.61 dbm 9

User should hold(>2s) backlight button to switch between 1310nm(CW) and 1310nm(Burst), unit will indicated by "CW" and "Burst" on the display, showed as right pictures 1310nm(CW) is continuous wavelength of 1310nm, 1310nm(Brust) is the Brust wavelength of 1310nm, this kind of signal is invalid during measuring the status of 1490nm and 1550nm wavelength. -21.70 dbm 6. Setting of REF value Push REF button to check setted reference value.showed as follow: -16.55 dbm -16.55 dbm Ref -0.00 dbm Ref -0.00 dbm Ref If you want to change current optical power as reference value,please hold(>2s)ref button in the measuring mode, meter will finish this job after one "beep", value on the display is result from the comparison with the reference value(unit is db). 10

7. Setting of backlight and guide for battery using This meter has backlight function,you could push backlight button to turn on backlight in the environment with insufficient light. This meter is low power consumption instrument, just need 2*AAA battery for normal use,but backlight will consume huge power, short the life of battery,so for the saving of power please turn off backlight in the environment with bright lights. Meter was integrated with charger, it will save your money for battery replacement, green and friendly to the environment, for the safety of operation please use our operational battery and charger. When charging the battery, the indicator light on the bottom will turn red and flash, it will turn to green after charging has finished. During operating of meter, if the icon at top right corner is rolling, means meter is charging. 8. Data storage function This meter can storage huge amount of data,up to 900 groups, in measuring mode hold(>2s) "load" button, then data will be saved after one "beep",right picture is the data of 1310nm (CW). - 5. 1 5 dbm Mem 001 11

Item "Mem 001" at Left bottom means the first group of data, it stand for the sequence of saved data, the value above is the power value for relevant wavelength. Push "LOAD"button to check saved data, use push page up, page down button could switch to last or next data. The provided software can read internal data and easy to elaborate by uppercomputer, please check software manual for detail. when storage space is full, hold(>2s) "dbm/db "button to erase some data in saving check mode. Right picture is the temporary interface during data erasing. After erasing, meter will go back to main interface automatically. Mem - - - - - - - - - - - - - - - 9. Port connection This meter is one kind of portable, multi-port instrument, with two optical measuring port at the top,usb and standard charge jack are at the bottom. It could measure upstream 1310nm(ONT) by port which marked with "ONT" measure 1490nm(OLT) downstreamˎ 1550nm downstream(video) signal by port which marked with "OLT/Video". 12

Notice Please follow the manual for proper operation. This meter is designed for PON network, operator should have the basic knowledge of PON network for better operation of this meter. This meter is high precision instrument, please don't use it in terrible environment (high temperature, high humidity,etc). Standard use with AAA battery, When the long period of time when not in use, please take batteries out for not spilling of toxic chemicals. Integrated with internal intelligent charger, please use optional rechargeable battery and adapter, manufacturer will take no responsibility for the damage caused by unproper charger or adapter. Because of the different condition,precision of meter will be difference,when external interference is huge, measuring will be disturbed, it's normal phenomenon, restart can slove the most of problems. 13

Maintenance Please shut off and cap protecting cover for fiber port after use then keep it in ventilated and dry place. Meter needs matched accessory and adapter for External power to prevent permanent damage. Clean fiber connector regularly. Please don't disassembly the meter,this may result in permanent damage and loss of guarantee qualification. Calibrate once a year to keep the high accuracy of measurement. 14