HOLLOW CATHODE LAMPS PRODUCT BROCHURE

Similar documents
Interaction of Infrared Controls And Fluorescent Lamp/Ballast Systems In Educational Facilities

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Fluorescence Spectrophotometer

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Light Emitting Diodes

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

Agilent 81600B Tunable Laser Source Family

Appendix B: An Automated Spectroscope

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

013-RD

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

721N Spectrophotometer. Operating Manual

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

-Sharp Telecentric backlight illuminator by EFFILUX

FiberLink 7142 Series

USA Price List. January or 8-channel LIBSCAN system (100 mj, 1064 nm laser) Alternative LIBSCAN configurations

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Agilent 8153A Lightwave Multimeter Technical Specifications

M2 Instruction Manual

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITHOUT METALLIC SCREEN

MKH 8060 Directional studio microphone

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

CITOCUT Plasma inverter cutting range

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

CITOCUT Plasma inverter cutting range

Monitor QA Management i model

Litho. Taking care of people, our masterpieces. Surgical Laser System. Surgery

Agilent 87075C Multiport Test Set Product Overview

Industrial Diode Laser (IDL) System IDL Series

Cathode Studies at FLASH: CW and Pulsed QE measurements

Operating Instructions

Tipping the balancetotal Cost of Ownership

Light is pure emotion XBO creates stars and moves audiences Light is OSRAM

Service. Nu Instruments Service & Upgrades. ICP-MS, GD-MS, IRMS, Noble Gas.

CORONA & PLASMA FOR NARROW WEB

Colorimeters and UV/Visible Spectrophotometers. from

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Klaran HC Series UVC LEDs

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

HP 70950B OPTICAL SPECTRUM ANALYZER

We bring quality to light. SNT 10 DC Power Supply

Introduction. Tokyo Kagaku Kenkyusho Co., Ltd.

Results of recent photocathode studies at FLASH. S. Lederer, S. Schreiber DESY. L. Monaco, D. Sertore, P. Michelato INFN Milano LASA

Advanced Test Equipment Rentals ATEC (2832)

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

Up to 85% higher Service Life due to efficient sealing method.

VGA to DVI Extender over Fiber SET

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

Selected Problems of Display and Projection Color Measurement

DD624CS Hi-Def Video Circle & Cross Hair Overlay Generator. Users Manual. Colorado Video

LUT Luminescence scanners: Seeing what no-one else can

OpticalProducts. Illuminating Your Network. Testing the World s Networks

SMT Encoder for High Performance, High Volume Designs Small Size High Resolution Low Cost ChipEncoder Reflective Surface Mount Encoder Features

Manual. USP-mini. icroflown Technologies. Address: PO Box CE Arnhem The Netherlands Charting sound fields

Spectroscopy Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

Comparison of SONY ILX511B CCD and Hamamatsu S10420 BT-CCD for VIS Spectroscopy

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

MXAN-LN series 1550 nm band Analog Intensity Modulators

Light is digital XBO is setting standards on the screen and on your mobile device Light is OSRAM

Application Note [AN-007] LCD Backlighting Technologies and Configurations

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

OP750. Multichannel Source Instruction Manual

SHARP Plasma inverter cutting range

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

OPTIMIZED LIGHT-EMITTING DIODE (LED) DEVICES THAT HAVE A HIGH COLOR RENDERING INDEX (CRI) FOR LIGHTING APPLICATIONS

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

High-Current Hollow Cathode Development *

Spectra Batten (Order code: LEDJ95)

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Model KT 53 Cooling incubators with thermoelectric cooling

Ultimate quality control. No compromise. PROCESS / QUALITY CONTROL

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

MPX / MPZ series. Low frequencies to 32 GHz Phase Modulators. Modulator. Features. Applications. MPX-LN series Performance Highlights

FiberLink 3350 Series

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

Development of OLED Lighting Panel with World-class Practical Performance

First, connect the LED and the resistor, by twisting the wires together.

COLOUR CHANGING USB LAMP KIT

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

MXAN-LN series 1550 nm band Analog Intensity Modulators

CARLITE grain orien TEd ELECTRICAL STEELS

Smart Lighting Demos

Good Laboratory Practices (GLP) Notepad. Automatic Datalogging. Automatic Stability Function. P.I.N. Code Security Access.

New product of near infrared (to 900 nm) detection

CORONA & PLASMA FOR NARROW WEB

It s important to stand out from the crowd.

An RF Excited Plasma Cathode Electron Beam Gun Design

Analog to Digital conversion of HD video. The HD-Now provides a simple method of upgrading ROVs for live HD. Keep existing infrastructure intact.

Thank you for purchasing a qualiton PHONO preamplifier!

Transcription:

HOLLOW CATHODE LAMPS PRODUCT BROCHURE

specialises in research, development and manufacture of high quality light sources for use in analytical spectography. The principals of Photron each have more than 50 years experience in both the design of spectographic instruments and light sources. The design for all lamps produced by Photron are based on actual use and experience with atomic absorbtion, UV-visible spectrophotometers and other spectroscopic instruments. Constant development of alloys, intermetallic species and cathode surface technology ensures the analyst of the best possible line source for atomic absorbtion spectography (AAS). Stringent process conditions, modern and efficient high vacuum equipment coupled with an intelligent selection of internal components provide Photron s Hollow Cathode Lamps (HCL s) with fast warm-up times and an extended shelf life guaranteed for 5 years from the date of manufacture. The successful development of the boosted discharge Hollow Cathode Lamp called the Super Lamp [see page 12] provides a simple and efficient equivalent to Electrodeless Discharge Lamps with a wider range of elements and a considerable reduction in cost. Photron can customise and manufacture lamps for OEM customers required scecifications using the purest elements available Eg: Optogalvanic effect & Astronomical background correction. Photron also manufacture a large range of Deuterium Lamps, Please refer to our D2 Brochure. We also supply OEM Quality Graphite tubes for most of the big instrument manufacturers and stock a supply of UV-Vis lamps. We pride ourselves on highly competitive pricing, stock on hand ready for dispatch, efficient manufacturing time and one of the fastest delivery services worldwide for our customers.

37mm or 1.5 Diameter Coded and Uncoded HOLLOW CATHODE LAMPS For Direct use in AAS systems manufactured by: Agilent, Varian, Analytic Jena, Thermo Fisher, GBC, Unicam and all other makes. Use in Perkin Elmer instruments can be facilitated with the use of an adaptor kit (P), however our 51mm (See page 6-7) HCL s are recommended. Hollow cathode lamps produced by Photron are designed and manufactured to achieve all of the following fundamental requirements for a spectral line source. Intense emission of resonance (ground state derived) lines. Narrow line width, for maximum sensitivity and linearity. Minimal spectral interference from continuum emission, present in the cathode. Rapid warm up to produce stable long term light emission. Noise free operation. Long running life and a 5 year shelf life. Cathode materials and geometry achieve a combination of spectral purity and a suitable sputtering rate. (A high sputtering rate will give high intensity at the expense of lamp life, sensitivity and linearity). SMITH-HIEFTJE BACKGROUND CORRECTION. Photron lamps have been tested and found to work as well as lamps sold specifically for this technique, however due to the high energy pulse used, some elements will be consumed at a higher rate reducing lamp life. CODED LAMPS P800C Series - For GBC and Varian AAS with coded recognition - pin. P800UC Series - For Thermo Unicam AAS with coded recognition - 7 pin.

ELEMENT SELECTION TABLE All lamp windows upgraded to Quartz for maximum transmission of the spectral line. CODED SERIES LAMPS Photron offer a large range of coded lamps for use in the following insrtruments: P800C Coded Series Lamps Pin Base Agilent / Varian Instuments GBC Instruments P800UC Unicam Coded Lamps 7 Pin Base Thermo Fisher / Unicam Instuments COMMON MULTI ELEMENT LAMPS The P873 was for exclusive use in foundries who only needed to measure concentration % in their melt if their emission spectrometer failed. It is of little use in detection limit applications. Note: For better detection limits, a single element lamp is recommended. Other combinations of elements can be ordred, please see page 8-9 or enquire. Add suffix A=Argon fill gas, H=Helium fill gas, X=Xenon fill gas, K=Krypton fill gas. 5 Annual Report - 11 5

51mm or 2.0 Diameter HOLLOW CATHODE LAMPS for use with Perkin-Elmer Instruments These hollow cathode lamps are produced to provide direct use without adapters in all Perkin-Elmer, AAnalyst & AAS instruments. All windows on these lamps are fully fused and contain no gassy adhesives which drastically reduce shelf life. Totally hermetic glass seals ensures a clean fill gas and cathode for the life of the lamp and most importantly a shelf life longer than 5 years. The application of the same glass cathode shielding technique used in all Photron hollow cathode lamps gives maximum stability and reliability throughout lamp life. Due to the elegantly simple design of the electrode geometry of Photron lamps, less mass is present within the lamp, reducing outgassing and making the lamp more resistant to breakage from lateral shock. 9 pin plug New Data Coded P900 LL for AAnalyst AAS 12 pin plug Still available from Photron. Perkin Elmer style P900, 9 pin and P900C, 12 pin plug 2 Lamps

ELEMENT SELECTION TABLE All lamp windows upgraded to Quartz for maximum transmission of the spectral line. COMMON MULTI ELEMENT LAMPS The P973 was for exclusive use in foundries who only needed to measure concentration % in their melt if their emission spectrometer failed. It is of little use in detection limit applications. Note: For better detection limits, a single element lamp is recommended. Other lamp combinations available. See page 8-9 or enquire. Cabled 9 pin and 12 pin lamps Available. The following Elements are available in Lumina bases but without Data Coding: Ce, Cs, Lu, Th, U. 7 Annual Report - 11 7

MULTI ELEMENT LAMPS 37mm or 1.5 Diameter Multiple Element HOLLOW CATHODE LAMPS Photron s Multi-Element Lamps are customized to suit customers needs. Benefits of Multi-Element Lamps include: Shorter warm up times. Multiple Element testing, reducing analysis times by eliminating the need to change lamps. MULTI-ELEMENTS CODED Agilent / Varian Coded Thermo Fisher Coded Photrons s range of multi-element lamps are all designed to balance the spectral line of each element equally.

51mm or 2.0 Diameter Multiple Element HOLLOW CATHODE LAMPS Limited amount of Coded available. MULTI-ELEMENTS Note: For better detection limits, a single element lamp is recommended 9 Annual Report - 11 9

Ph (61-3) 970 99 Fx (61-3) 970 6289 service@photron.com.au sales@photron.com.au 5 8 6 25 12 0 35 12 8 0 0 6 25 5 5 5 25 5 7 16 8 0 0 7 8 6 3 5 8 8 6 25 0 0 12 7 3 6 5 6 12 12 1 35 8 35 35 8 1 25 8 25 Colour denotes elements that can be made into Hollow Cathode Lamps 11

SUPER LAMP PAT. High Intensity Sharp Line Source for AAS and AFS Spectroscopy The Super Lamp is particularly recommended for the following determinations in Atomic Absorption Spectroscopy. Elements with resonance spectra in the far UV where instrumental efficiency is reduced e.g. Arsenic and Selenium. Elements with complex spectra, where the enhanced resonance line reduces the interference of background radiation, allowing the use of wider slit widths further reducing signal to noise. e.g. Nickel and Iron. For determinations at or near the detection limit, in some cases a fold improvement in detection limit can be achieved. This lamp produces intense spectra with narrow line widths. Volt Super Lamps are also used in Atomic Flourescence Spectography.

ATOMS AT GROUND STATE (NOT EXCITED) THESE ABSORB EMITTED RADIATION FROM EXCITED ATOMS RADIATION ANODE NORMAL HOLLOW CATHODE DISCHARGE CYLINDRICAL CATHODE MOST OR ALL ATOMS EXCITED HALF WIDTHS OF THE 193.7nm ARSENIC LINE STANDARD HOLLOW CATHODE LAMP 8 ma 193.696 nm SELF ABSORPTION ma 193.696 nm BOOSTED DISCHARGE HOLLOW CATHODE LAMP /50 ma 193.696 nm LINE WIDTH 0.00089 nm /50 ma 193.696 nm CATHODE EXCITED ATOMS ANODE ELECTRON EMITTER AUXILIARY BOOST DISCHARGE LINE WIDTH 0.00089 nm LINE WIDTH 0.006 nm NO SELF ABSORPTION ONLY SLIGHT BROADENING OF LINE LINE WIDTH 0.00071 nm ABS 0.600 0.500 0.00 ABS 0.600 0.500 0.00 IMPROVEMENT TO DETECTION LIMIT DUE TO THE INCREASED SENSITIVITY AND REDUCTION OF BASELINE NOISE STANDARD HIG H INTENSIT Y LAMP BOOST PHOTRO N SUPER LAMP BOOST 0.0 0.0 0.0 0.0 CLEAN PEAK 0.0 0.600 0.0 0.600 LESS NOISE NORMAL HOLLOW CATHODE ATOMS NOT EXCITED CATHODE ALL ATOMS EXCITED Time 1235 6 Time 1235 6 seconds seconds Standard Hollow Cathode Lamp Super Lamp 0 Pbb Arsenic 0 Pbb Arsenic END OF CATHODE CLOSED -% EFFICIENT OPEN ENDED CATHODE 0% EFFICIENT 13 Annual Report - 11 13

P800 37mm, Super Lamps P800 37mm, Volt Super Lamps P900 51mm, Super Lamps Intensity gain over Std lamp Denotes SuperLamp intensity gain over standard Hollow cathode lamp. Other elements available upon request.

APPLICATION SOURCE LAMP This new product has 6 individual cathodes in a single envelope. This provides either 6 single elements with the same spectral purity and intensity as a single element lamp or 2 or more elements per cathode allowing many analytical laboratories to have all their element range provided for in one longer life lamp. Choose from the following 11 standard Application Sources or contact us to design your own element combination. Currently this lamp is only directly usable in a GBC 932plus and a Sensor AA atomic absorbtion Spectrophotometer.

ASTRONOMICAL CALIBRATION LAMPS Thorium / Argon (Th/Ar) Hollow Cathode Lamps ASTRONOMICAL CALIBRATION LAMPS Astronomical spectrographs are used for a variety of high-precision measurements, ranging from the discovery of low-mass exoplanets to the possible variation of fundamental constants, such as the fine structure constant or the proton-electron mass ratio. These works require excellent wavelength calibration sources and a detailed understanding of the associated uncertainties and systematics. In the era of extremely large telescopes, it is often the accuracy of the calibration source, not the intrinsic photon noise, that limits the achievable precision. Furthermore, the science goals of future extremely large telescopes will require very high precision calibration sources. Below 900 nm, the well-established thorium-argon (Th/Ar) hollow cathode lamps have been a workhorse. Continual improvements in the line list have now enabled Th lamps to be used to calibrate almost the entire optical bandpass with high precision. Hollow cathode lamps, being significantly less expensive and easier to use, are the preferred wavelength calibration solution for most astrophysical spectrographs. Thorium (232Th), an element often used as the cathode for such lamps, exhibits many of the desired characteristics of an atomic emission calibration source: it has many energy levels (leading to many lines), a heavy nucleus, a very long half-life, and occurs in nature as a single isotope. Other elements such as Uranium can be used as a calibration source. * Power supply required to run the lamp is P9. Also optional P217, m Extension lead cable

OPTOGALVANIC LAMPS See-Through Hollow Cathode Lamps SEE THROUGH HOLLOW CATHODE LAMPS (LASER CALIBRATION) Photron manufactures Optogalvanic (see-through) hollow cathode lamps, they are designed to act as a frequency stable reference for high intensity tuneable monochromatic light sources, particularly lasers. Most of the cathode materials used in standard hollow cathode lamps may be used in the see-through design. We can also offer a range of fill gases, such as: Neon, Argon, Xenon and Krypton. Photron POWER SUPPLY and ACCESSORIES The Photron hollow cathode power supply (P9) provides a precision current source to correctly drive Photron hollow cathode lamps at a specific current. This allows use of a stand-alone hollow cathode lamp for purposes such as laser frequency tuning, Astronomy with P858A Thorium Lamps and Optogalvanic Lamps as well. Current is adjusted by a ten turn current control on the front panel. The current is constantly displayed on the front panel meter for ease of adjustment. Current range is 0 to 25mA and a 600V automatic starting voltage is provided to enable even ageing lamps to start correctly. 17

Photron POWER SUPPLY and ACCESSORIES The Photron Super lamp power supply adds a boost discharge for use with Super lamps, the lamp uses existing spectrophotometer lamp current, the power supply adds a boost discharge to increase excitation of atoms sputtered by the instrument lamp supply. This boost current is linked by circuitry inside the power supply and the boost discharge is transmitted at the same rate as the instrument. The boost discharge when increased from zero will reach a peak light intensity and then cause the level to drop off. This effect means that instruments with different electronic systems will require different boost currents to achieve the peak signal output. With the simple operation of setting the boost, makes the Superlamp a fast more sensitive and cost efficient than other systems. Photron s Superlamp power supply can be fitted to many Atomic Absorbtion instruments including; Varian, Perkin Elmer, GBC Scientific, Unicam, Hitachi, Shimadzu, Analytic Jena and many others. Photron also offers adaptors which may be required to fit the power supply to some instruments. The Superlamp power supply has obtained the mark certification. POWER SUPPLY SPECIFICATIONS INPUT VOLTAGE: DIMENSIONS: CONTROLS: 0,1,2,20, 50/60Hz 0VA 360 x 3 x 135 mm, weight: 6kg. Mains switch, boost current control, 0-0mA meter.

PHOTRON S QUALITY POLICY is engaged in the design and production of highly specialised items of equipment for incorporation in atomic absorption spectrometers for use in chemical analysis. In particular, Photron Pty Ltd is highly skilled in the art of manufacturing atomic spectral lamps, which can emit ultra-violet and visible radiation characteristics of any selected element. Photron is one of the worlds leaders in the manufacture of such lamps which are sold world wide. The motivation that drives Photron Pty Ltd is simple; we want to make a better product than our competitors. Photron Pty Ltd quality commitment is demonstrated by: Routine in-house and field testing and quality conformance checking. Attention to detail and committed to customer needs. Maintaining contact with our customers to ensure their satisfaction with the quality of our goods and services. Maintaining a quality management system which meets the requirements of Australian Standard AS/NZS ISO 9001:00. Improvement in the quality of our performance can only result from a total team effort. Our aim will only be achieved by properly motivated, trained and appreciated staff who are conscious of doing it right the first time. Every member of the Photron organisation has a responsibility for quality. Jim Green CEO Photron Pty. Ltd. 19 Annual Report - 11 19

PHOTRON WARRANTY Hollow Cathode Lamps All Photron hollow cathode lamps and the Super Lamp PAT. are warranted to be free of material and manufacturing defects when operated at the correct current for each instrument detailed on the lamp operating data sheet supplied for each element. The operational lifetime of all of the above is rated at 5000mA Hrs based on the currents specified in the data sheet, e.g. lamp run at ma last 500Hrs. The use of currents higher than specified particularly on instruments where high peak currents are used, will shorten the life for some elements. Those affected either have a high vapour pressure (Hg As Se) or high sputtering rate (Au Cd Zn). Warranty claims regarding lamp failure will be considered up to 2 years from date of purchase. Warranty claims must accompany a completed warranty card. If a free replacement lamp is supplied the validity of guarantee shall date from shipment of the first lamp. The shelf life of unused lamps are warranted for 5 years from the original purchase, any hollow cathode lamp found faulty before any use will be replaced. Unit 1 / Deblin Drive, Narre Warren Victoria 3805, Australia Ph (61-3) 970 99 Fx (61-3) 970 6289 www.photronlamp.com service@photron.com.au sales@photron.com.au Copyright 1 Photron Pty. Ltd. All rights reserved Purchase online: www.photronlamp.com