i n t r o d u c i n g Sterilizers H A R V E Y S T E R I L I Z E R S Harvey Sterilizers the newest Barnstead Thermolyne product line!! Sterilemax Steam Sterilizers MC8 and MC10 Steam Sterilizers Chemiclave Chemical Sterilizers
PRODUCT SELECTION GUIDE HARVEY STERILIZERS Sterilizer Model Chamber Size Outer Dimension Sterilizing Agent Cycle Types Dry Cycle Printer Page STERILEMAX MC8 MC10 12 Diameter, 18 Depth 23 W x 24.5 D x 17 H Steam Liquid 15 min. @ 121 C No optional 138 (30.4 diam.x 45.7 cm) (58.4 x 62.2 x 43.1 cm) Unwrapped 3 min. @ 135 C Yes Wrapped 10 min. @ 135 C Yes Packs 30 min. @ 121 C Yes 8 Diameter, 14.5 Depth 13 W x 22 L x 16 H Steam Liquid 30 min. @ 121 C No optional Datalogger 140 (20.3 diam.x 36.8 cm) (33.0 x 40.6 x 55.9 cm) Unwrapped 3 min. @ 135 C Yes Wrapped 10 min. @ 135 C Yes Packs 30 min. @ 121 C Yes 10 Diameter, 15.5 Depth 16 W x 23 L x 18 H Steam Liquid 30 min. @ 121 C No optional Datalogger 140 (25.4 diam. x 39.3 cm) (40.6 x 58.4, 45.7cm) Unwrapped 3 min. @ 135 C Yes Wrapped 10 min. @ 135 C Yes Packs 30 min. @ 121 C Yes CHEMICLAVE 8 Diameter, 13.25 Depth 15.75 W x 23 D x 10.75 H Chemical Vapor Fixed 20 min. @ 132 C NO NO 142 (20.3 diam. x 33.6 cm) (40.0 x 58.4 x 27.3 cm) 10 Diameter, 16 Depth 19.25 W x 16.25 D x 26.25 H Chemical Vapor Fixed 20 min. @ 132 C NO NO (25.4 diam. x 40.64 cm) (48.9 x 41.28 x 66.06 cm)
H A R V E Y S T E R I L E M A X new It s everything you want in a tabletop sterilizer. Because you said so. We surveyed researchers like you to find out what features were important and then we created SterileMax, accordingly. What did you ask for? A 17% larger chamber area which can hold three 2-liter flasks. Removable racks and trays for smaller loads. Four pre-set cycle programs. Built-in water pump. Easy-to-read digital display. Safety features and much more. Four preset cycle programs Largest benchtop sterilizer chamber available! BENEFITS 17% more chamber area than traditional table top units. Holds three 2-liter flasks simultaneously. The 12 x 18 (30.4 x 45.7 cm) chamber contains removable racks and trays for easy cleaning, smaller loads, sensitive glassware, and other unique sterilization requirements. Four preset cycle programs allow one touch operation for liquids, wrapped goods, unwrapped goods, and packs. Custom programs can be set for liquids or other hard goods. Built-in water pump maintains consistent water supply and accurate steam for every cycle. To regularly test sterilization performance, an access port is built into the SterileMax for easy and safe verification of temperature and pressures. The Sterilemax is the only table top sterilizer with this feature. Easy to set up, can be easily moved from lab to lab. Easy to read LCD display lets you view sterilization and diagnostic programs and displays all aspects of cycle for quick visual verification. Three locks on chamber door ensure your safety. Door will not open until chamber is depressurized. The Sterilemax is ASME, UL, CE and CUL approved. Built and tested to rigorous industry requirements. Unique custom insulation retains maximum heat in chamber for quick heat-up and less heat loss between cycles. Independent validation testing done by Biotest Laboratories, Minneapolis, MN. for sterility, accuracy and verification of all programs. Meets all current requirements for tabletop sterilizers. LCD will display faults to indicate when sterilization has not been reached in the chamber. Compliant to year 2000 operation. 2 year warranty.
H A R V E Y S T E R I L E M A X Easy to read LCD Display. Triple door lock ensures safety. Electrical (50/60 Hertz) Model # Descriptions Volts Amps Price ST75935 SterileMax Sterilizer with printer 120 12.5 ST75925 SterileMax Sterilizer without printer 120 12.5 ST75930-33 SterileMax Sterilizer with printer 220 6.5 ST75920-33 SterileMax Sterilizer without printer 220 6.5-33 models, CE marked Accessories Model # Descriptions Price SH759X1 Cassette Rack, holds 12 small IMS or 4 large IMS cassettes TY759X2A Large Tray (SterileMax accommodates up to 3 large trays) TC759X1A Temperature Verification Probe Assembly, Type K PM20700 Digital Pyrometer Specifications Overall Dimensions 23 W x 24.5 D x 17 H *58.4 x 62.2 x 43.1 cm) Chamber Size 12 Diameter, 18 Depth (30.4 x 45.7 cm) Chamber Capacity 1.2 Cubic Feet (34 L) Heater Wattage 1500W Shipping Weight 134 lbs. (60.7 kg) Operational Weight 85 lbs. (38.5 kg) Fixed Cycle Parameters Liquids: 15 min @ 121 C Unwrapped: 3 min. @ 135 C Wrapped: 10 min. @ 135 C Packs: 30 min. @ 121 C Optional Cycle Parameters 1-99 min @ 100 C - 136 C Accessories Included: Rack, 1 Large Tray, 1 Small Tray
H A R V E Y M C 8 / 1 0 Harvey MC8 and MC10 sterilizers offer the convenience of four pre-set keep cycles and self-cleaning non-recirculating operation in a design to fit your benchtop and your budget. The time-saving, one-button operation cycles the unit from start to finish. And the optional non-recirculating feature makes this already reliable unit even more trouble-free by preventing the recirculation of debris and contaminants reducing costly routine maintenance and down time. Compact Design Intuitive Software Choose from two chamber sizes MC10, MC8 MC10 Simple to operate - one touch controls 4 present cycles - wrapped, unwrapped, packs, and liquids Automatic drying cycle Non-recirculating option - increases reliability of system by preventing debris and contaminants from recirculating into filters Door closed drying - protect against airborne contaminants Easily accessible reservoir - easy to clean, reduces down time ASME coded chamber, ETL, UL certified Special venting for liquids to reduce boil over. Allows cycle to run under 45 minutes for EPA Standards Optional printer for hard copy records Easy to set up - can easily be moved from lab Built and tested to rigorous industry standards Contains removable racks and trays for easy cleaning Compliant to year 2000 operation 2 year warranty Chamber holds three one liter flasks Non-recirculating option keeps internal components and filters free of debris and contamination. One button pre-set programs, cycle the unit from start to finish.
H A R V E Y M C 8 / 1 0 Model # Description Volts/Amps Price 265560 Harvey MC10 120V, 50/60 hz, 12 amps 265565 Harvey MC10 230V, 50/60 hz, 6 amps 265588 MC10 with Non-recirculating Feature* 120V, 50/60 hz, 12 amps 265589 MC10 with Non-recirculating Feature* 230V, 50/60 hz, 6 amps 265591 MC10D with Built-in Data Logger 120V, 50/60 hz, 12 amps 265840 MC10D with Built-in Data Logger 230V, 50/60 hz, 6 amps 265575 MC10D with Non-recirculating Feature and built-in Data Logger 120V, 50/60 hz, 12 amps 265580 MC10D with Non-recirculating Feature and built-in Data Logger 230V, 50/60 hz, 6 amps 265595 Harvey MC8 120V, 50/60 hz, 12 amps 265600 Harvey MC8 230V, 50/60 hz, 6 amps 265610 MC8 with Non-recirculating Feature 120V, 50/60 hz, 12 amps 265615 MC8 with Non-recirculating Feature 230V, 50/60 hz, 6 amps 265585 MC8 with built-in Data Logger 120V, 50/60 hz, 12 amps 265617 MC8 with built-in Data Logger 230V, 50/60 hz, 6 amps 265608 MC8 with Non-recirculating feature and Built-in Data Logger 120V, 50/60 hz, 12 amps 265612 MC8 with Non-recirculating feature and Built-in Data Logger 230V, 50/60 hz, 6 amps 265593 Separate, Plug-in Data Logger for MC8 *Non-recirculating Feature Patent # 5,480,623. Sterilizer Accessories Model # Description Price 265656 Non-Recirculating Feature for MC8 or MC10, Retrofittable and easily installed. 260284 Datalogger Paper for MC units (Box of 6 rolls) 264116 Printer Ribbon for MC units 2-513025 Standard Tray Rack for MC10 265002 Standard Tray Rack for MC8 2-67811 Tray large (9 x 15 ), for MC10 265001 Tray, small (6.25 x 14.25 ), for MC8 232010202 Metal Polish-Pint bottle with spray top, case of 6 232010102 Chamber Cleaner-Pint bottle with dispenser top, case of 6 2-69904 Door Gasket for Harvey MC8 (Replace once per year to assure best seal) 2-513005 Door Gasket for Harvey MC10 (Replace once per year to assure best seal) Harvey MC8 and MC10 Steam Sterilizer Specifications (Code Approvals:ASME & ETL.) MC8 MC10 Overall Dimensions 13W x 16H x 22L inches 16W x 18H x 23L inches (33.0 cm x 40.6 cm x 55.9 cm) (40.6 cm x 45.7 cm x 58.4 cm) Chamber Dimensions 8 diameter x 14.5 usable depth 10 diameter x 15.5 usable depth (20.3 cm diameter x 36.8 cm usable depth) (25.4 cm diameter x 39.3 cm usable depth) Tray Size 12 x 0.625 x 0.875 One 15.25 x 9 x 1.25 (30.4 cm x 14.2 cm x 2.2 cm) (38.7 cm x 22.8 cm x 3.2 cm One 14 x 6.25 x 0.875 (35.6 cm x 15.5 cm x 2.2 cm) Operational Weight 55 lbs (25 kg) 70.5 lbs (32 kg) Shipping Weight 73 lbs (33 kg) 92 lbs (42 kg) Heater Wattage 1350 Watts 1425 Watts Maximum Rated 45 psi (310 kpa) 45 psi (310 kpa) Operating Pressure Reservoir Capacity 3.0 L (approximately 3 qts.) 4.0 L (approximately 4 qts.) Barnstead Thermolyne produces a full range of distillation systems which produce distilled water for steam sterilizers. Call Barnstead Thermolyne Customer Service at 800-446-6060 for more information on these products.
H A R V E Y C H E M I C L A V E The Harvey Chemiclave is a fully automated and proven device for sterilizing medical and dental instruments without dulling, rusting, corroding or otherwise impairing their properties. The chemical vapor process protects your investment in instruments. Extends the life of your instruments CHEMICLAVES - EC5500, EC6000 No better way to extend life of your instruments Automatic cycles starts sterilization cycle when unit reaches proper sterilization conditions Electronic display times the 20 minute exposure phase and the purge phase. Automatic purge for removal of vapor from chamber before door is opened Easy to fill system for sterilant - prevents spillage Built in chemipurge and chemifilter to slash emissions Dry packs and instruments at end of cycle No drying phase required Preheated chamber reduces overall cycle time Meets industry standards for ASME and CSA Operates at 132 and 20-40 psi Sterilization cycle of 20 minutes Easy to remove rack for quick cleanings Proprietary solutions ensures consistent quality results Intuitive control panels informs you of cycle status. Built-in Chemi-filter virtually eliminates odor. Chemiclave utilizes a chemical vapor process with Vapo-Steril to extend the life of your instruments.
H A R V E Y C H E M I C L A V E Model # Description Price 266270 EC5500 Harvey Chemiclave Chemical Sterilizer 120V, 60 hz, 8 amp, 8 chamber 266200 EC5500 Harvey Chemiclave Chemical Sterilizer 230V, 50/60 hz, 4 amp, 8 chamber 266440 EC6000 Harvey Chemiclave Chemical Sterilizer 120V, 60 hz, 12 amps, 10 chamber Barnstead Thermolyne produces a full range of distillation systems which produce distilled water for steam sterilizers. Call Barnstead/Thermolyne Customer Service at 800-446-6060 for more information on these products. (All units include a chemifilter chamber tray, tray handle, drain tube, chamber cleaner, indicator bags, tray liners and Chemitest indicators.) Vapo-Steril Solution sold separately. See Accessories below. Harvey Chemiclave Sterilizer Specification (code Appprovals:ASME, ETL.) Chemiclave EC5500 Chemiclave EC6000 Overall Dimensions 16.75 W x 13 H x 23 D 19.25 W x 16.25 H x 26.25 D (42.5 cm x 33 cm x 58.42 cm) (48.90 cm x 41.28 cm x 66.68 cm) Chamber Dimensions 8 dia. x 13.25 deep 10 dia x 16 deep (20.32 cm x 33.66 cm) (25.40 cm x 40.64 cm) Reservoir Capacity 28 fluid oz. (0.84 litre) 39 fluid oz. (1.17 litres) Heater Wattage 800 Watts 1200Watts Fixed Cycle Parameters 20 min. @132 C 20 min @132 C Operating Pressure 20-40 psi 20-40 psi (1.41-2.82 kg/cm 2 ) (1.41-2.82 kg/cm 2 ) Operating Temperature 270 F±2 270 F±2 (132 C±2 ) (132 C±2 ) Operational Weight 59 lbs. (26.8 kg) 120 lbs. (54.55 kg) Shipping Weight 73 lbs. (32.2 kg) 134 lbs. (60.91 kg) Harvey Chemiclave Accessories Model # Description Price 264253 VAPO-STERIL Solution - Case: 4 each 4 - packs 261823 Diameter-Indexed Filter Top Only (Use as replacement or extra). 260812 Canadian Vapo-Steril w/french Label Case: 4 each, 4-packs 231600201 Standard Tray for Chemiclave EC6000 231550201 Tray for Chemicalve EC5500 264255 Chemi-filter. Pkg. of 4 for Chemiclave EC550 and EC6000 261569 Chemifilter. Pkg. of 1 260006701 Door Gaskets for Chemiclave EC6000, EM6000 280000301 Door Gaskets for Chemiclave EC5500, EM5500. (Replace once per year to assure best seal) Tray Liners 231600401 Chamber Tray f or Chemiclave EC6000. 16 (40.6 cm) x 14 (35.6 cm) 231550401 Chamber Tray for Chemiclave EC5500. 12.75 (32.4 cm) x 11.5 (29.2 cm) -Box of 500 231601301 Set-Up Tray: 14.5 (36.8 cm) x 7.5 (19 cm)-box of 250 231603001 See-Thru Tray: 8 (20.3 cm) x 11.125 (28.3 cm)-box of 250 230300001 Self-Sealing Chemitest Indicator Bags (Tray Size)-150 per box 230301001 Self-Sealing Chemitest Indicator Bags (Instrument Size). 250 per Box, 2.5 W (6.3 cm) x 1.5 H (3.8 cm) x 10.5 L (26.7 cm) 230302001 Chemitest See-Thru Indicator Pouches (Tray Size). 150 per box, 5 W (12.7 cm) x 15 L (38.1 cm) 230303001 Chemitest See-Thru Indicator Pouches (Instrument Size). 250 per box, 3 W (7.6 cm) x 12 L (30.5 cm) See-Thru pouches are a combination of mylar and paper. May be sealed with Chemitest indicator tape.
H A R V E Y B I O L O G I C A L I N D I C A T O R S Now there s a way to monitor the effectiveness of your steam sterilizer that s easier, faster and less expensive than sending biological indicators to an outside lab. It s the new Harvey B/T Sure and Sterilamp II Biological Indicators. Verify your sterilization process in your lab Sterilamp II B/T Sure Biological Indicator HARVEY STERILITY ASSURANCE INDICATORS Verify the sterility of your instruments, vials, media, liquid cycles and other products in less time than it takes to send samples to an outside lab. Save up to 60% of the cost of outside laboratory sterility tests. Obvious color change from purple to yellow indicates an ineffective sterilization process. Two biological indicators to choose from: 1) for media and liquids 2) for instruments, glassware and other applications. For Media and Liquids Sterilamp II Biological Indicators with spore populations* of 10 6. Available in boxes of 25 or 100. For Instruments, Glassware and Other B/T Sure Biological Indicators with spore populations* of 10 5. Other spore populations are available upon special request. Harvey Sterilization Process Validation Indicators Model # Description Price Biological Indicators for instrument glassware and other product verification AY759X1 B/T Sure Biological Indicator (Box of 5 Indicator vials) Spore population 10 5 AY759X3 B/T Sure Biological Indicator (Box of 100 Indicator vials) Spore population 10 5 AY759X8 B/T Sure Biological Indicator (Box of 100 Indicator vials) Spore population 10 6 Biological Indicators for media and liquid cycle verification. AY759X4 Sterilamp II Biological Indicators (Box of 100) Spore population 10 6 AY759X7 Sterilamp II Biological Indicators (Box of 25) Spore population 10 6 Incubator for processing Harvey Biological Indicators DB104115 Harvey Incubator, 120V DB104110-33 Harvey Incubator, 240V, CE marked *Sterilamp II is a registered trademark of SGM Biotech. B/T Sure Biological Indicator Incubator
H A R V E Y B I O L O G I C A L I N D I C A T O R S Are you confident that your sterilizer reaches adequate sterilization temperatures each time you run a cycle? Include a Harvey Temperature Indicator in every sterilization cycle for an instant reading of whether proper temperature has occurred for sterilization. Verify your sterilizers temperature with every cycle DAILY TEMPERATURE VERIFICATION ACCESSORIES Available in pouches, strips or tape Color change indicates that your sterilizer has reached proper temperature. Indicators assure that items being processed have been run through a cycle, preventing the accidental use of items which have not been processed. Alternate the use of Harvey Temperature Indicators with the Harvey sterilization process validation procedure for guaranteed assurance of your sterilizers performance. Temperature Verification Accessories (Include in every sterilizer load for daily confidence.) Model # Price AY759X2 Chemical Indicator Strips (Box of 250) Steam Sterilizers only. 260577 Chemitest Indicator Tape-Closure system for packs, bags or other containers. Roll is 1.5 (3.8 cm) x 360 L (91.4 mm) 230305001 Chemitest Indicator Strips, (Box of 250) Chemiclave Sterilizers only. 230306001 Chemitest Indicator Tabs, Roll of 250, Self-adhering tabs. 1.5 (3.8 cm) sq. Instrument Packaging for Clean Process and Temperature Verification Model # Price 230300001 Self-Sealing Chemitest Indicator Bags, Tray Size (Box of 150) 5 W (12.7 cm) x 2 H (5.1 cm) x 15 L (38.1 cm) 230301001 Self-Sealing Chemitest Indicator Bags, Instrument Size (Box of 250) 2.5 W (63 cm) x 1.5 L (3.8 cm) x 10.5 L (26.7 cm) 230302001 Chemitest See-thru* Indicator Pouches, Tray Size (Box of 150) 5 W (12.7 cm) x 15 L (38.1 cm) 230303001 Chemitest See-thru* Indicator Pouches, Instrument Size (Box of 250) 3 W (7.6 cm) x 12 L (30.5 cm) *See-thru pouches are a combination of mylar and paper. May be sealed with Chemitest indicator tape.