Datascope Spectrum OR With Gas Module 3 Monitor

Similar documents
Patient Monitoring Solutions

PRODUCT BROCHURE. LIFEPAK 20e DEFIBRILLATOR/MONITOR. Always on call

No wonder medical professionals trust the LIFEPAK 20e

LIFEPAK 20e DEFIBRILLATOR/MONITOR. with CodeManagement Module

BeneHeart R3. Electrocardiograph

Advanced Test Equipment Rentals ATEC (2832)

TSG 90 PATHFINDER NTSC Signal Generator

Agilent 5345A Universal Counter, 500 MHz

HearTwave II Specifications

medlab One Channel ECG OEM Module EG 01000

R&S RT-Zxx High-Voltage and Current Probes Specifications

DEFIBRILLATOR ANALYZER

Advanced Test Equipment Rentals ATEC (2832)

ScopeMeter 190 Series Specifications

SECULIFE DF+ DEFIBRILLATOR ANALYZER

Digital Storage Oscilloscopes 2550 Series

R&S RT-Zxx High-Bandwidth Probes Specifications

R Series Quick Reference Guide

PROGRAMMABLE PATIENT SIMULATOR REMOTE CONTROL WITH TRENDING PSR-2200-MP

Specifications. Reference Documentation. Performance Conditions

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

Fluke 279 FC True-rms Thermal Multimeter

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Microwave Counter, Power Meter and DVM in One Portable Package

R&S EDS300 DME/Pulse Analyzer Specifications

PicoScope 6407 Digitizer

Data Pattern Generator

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02


2 MHz Lock-In Amplifier

56-23 Synopsis of Vital Signs Monitors (Project 98-35) (1/99)

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

Help Manual. Monitoring Devices. For the following devices: SJM Confirm Implantable Cardiac Monitor Confirm Rx Insertable Cardiac Monitor

Technical Description

4 MHz Lock-In Amplifier

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

1.2 General Description

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

PT-LB382 S P E C F I L E. LCD Projectors. As of July Specifications and appearance are subject to change without notice. 1/9.

Full-featured CW Microwave Counters for Field, Factory or Lab

Gateway 46-inch Plasma TV Specifications

0.01 (amplitude) The amplitude at 0.01s from QRS loop (angle) The angle at 0.01s from QRS loop

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

Technical data. General specifications. Indicators/operating means

LAUREL ELECTRONICS, INC.

Modular Lube Lubrication Systems System Controls

TABLE OF CONTENTS. Instructions:

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

26 Inch CGA/EGA/VGA/DVI to WXGA/1080p LCD - ID#703

PRODUCT SHEET

PRODUCT SHEET

R3267/3273 Spectrum Analyzers

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

SCALE & WEIGHT DISPLAYS

Diogen 24/24 two-regime seismograph

Product Number : LW373 Product Name : As of October Specifications and appearance are subject to change without notice.

Gateway 50-inch Plasma TV Specifications

VA951S. 19 5:4 LED Display with SuperClear Technology. Overview. Legacy Application-friendly 5:4 Aspect Ratio

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name

BS36 Waveform TDR (Time Domain Reflectometry) Cable Fault Locator

PicoScope 6407 Digitizer

PT-LB385 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

AF-300 E11 Adjustable Frequency Drive

DS2460Q QAM Analysis Meter

19 Widescreen LED Display VA1903a 16:9 Widescreen optimised for HD Content

HK-DID-MXA-VGA-X-Y. Product Name. Describe. Application. Characteristic. Product Model. Screen Matrix Switcher

Displays AND-TFT-5PA PRELIMINARY. 320 x 234 Pixels LCD Color Monitor. Features

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

Monday 20 May 2013 Afternoon

WVR500 Waveform/Vector Monitor

Agilent Technologies 54522A

Datasheet SHF A

Operating Instructions

2016 RIGOL TECHNOLOGIES, INC.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

SM-10 SAT Level Meter User s Manual

The measurements are stored in non-volatile memory, which retains data even when the power down.

LMD-1541W. 15-inch high grade LCD monitor. Overview

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

User s Manual of Signal Level Meter TABLE OF CONTENTS

EGM Einthoven Goldberger Module Type 701

DISTRIBUTION AMPLIFIER

Simple all-in-one design style with front stereo speakers and natural ventilation system

Electrocardiograph ECG-2550

CERTIFICATE of EU TYPE-EXAMINATION

NOW all HD Panacea Routers offer 3 Gb/s (1080p) performance!

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

Transcription:

Datascope Spectrum OR With Gas Module 3 Monitor Typical Manufacturer s Picture Features: Built-in, vivid 12.1-inch display with autoadjustablelarge numerics and waveforms for optimal visibility. Includes the standard functions you need for perianesthesia monitoring including 3 or 5-lead ECG, non-invasive blood pressure, Masimo SET motion tolerant SpO2, temperature, and drug calculations. Offers various options to best meet your department s needs including microstream, CO2, BISx Module, Nellcor OxiMax SpO2, cardiac output, continuous cardiac output/svo2*, invasive blood pressures, ST and arrhythmia analysis and more. Optional Gas Module 3 Specifications The Gas Module 3 incorporates improved Artema technology that enables respiratory gas analysis, displayed on the Spectrum OR line of monitors The Gas Module 3 delivers state-ofthe-art gas analysis capabilities: identification and measurement of inspired and expired O2, CO2, N2O, and any one of the following five anesthetic agents - Isoflurane, Sevoflurane, Desflurane, Halothane, and Enflurane. Providing impressive capabilities and highly reliable performance, this leading-edge breath-by-breath multi-gas analyzer was designed to meet the comprehensive anesthesia monitoring requirements of virtually every hospital - whatever its size, specialty, or patient base DISPLAY Size: 12.1-inch (30.7cm) Color Active Matrix TFT LCD Resolution: 800 x 600 pixels Waveforms: 3 to 8 ECG (3-LEAD AND 5-LEAD) Leads: I, II, III, avr, avl, avf, V Cable Detection: Autodetecting Datascope 3 or 5 wire Display Sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0, cm/mv ± 10% Frequency Response To Screen Extended Mode: 0.05 100 Hz, -3db Monitor Mode: 0.5 40 Hz, -3db ST Mode: 0.05 40 Hz, -3db ECG Sync Pulse for Cardioversion:

Delay: 35 ms max between QRS Peak and rising edge of Sync Pulse Amplitude: 2Vp minimum into a 5k ohm load Width: 2-7 ms Analog Output: (ECG) Delay: 25 ms max Sensitivity: 1 V/mV of input, ± 10% Defibrillator Overload Protection: Withstand 360 Joule discharge as per IEC 60601-2-27, 51.101.1 Recovery Time: Time for recovery to within 1mV in < 8 seconds automatically. 3 seconds from 1Vpp at 60 Hz HEART RATE METER Range: 30 300 BPM Adult/Pediatric, 30 350 BPM Neonate Accuracy: ± 3 BPM or ± 3% at 30 250 BPM whichever is greater, ± 5% at 251 350 BPM Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mv to ± 700 mv and duration 0.1 to 2 ms with no tail. AAMI EC-13-1992 4.1.4 (3-Lead and 5-Lead) Rejects all pulses of amplitude ± 2.0 mv to 700 mv and duration 0.1 to 2 ms with 100 ms time constant tail of less than 2.0 mv, or 4 ms time constant tail of < 2.0 mv per AAMI EC-13-1992 3.1.4.2 Tall T-Wave Rejection: Rejects all T-Waves of amplitude less than 120% of 1 mv, 100 ms QRS, T wave duration of 180 ms and Q-T interval of 350 ms per AAMI EC-13-1992 4.1.2.1 (c) ST ANALYSIS 3-lead or 5-lead Range: -9.9 mm to +9.9 mm Resolution: 0.1 mm Default ST Measuring Point: 80 ms after j point for HR <120 BPM, 60 ms after j point for HR >120 BPM ARRHYTHMIA ANALYSIS 3-lead or 5-lead cables: Adult / Pediatric Only: Asystole, Irregular Heart Rate, Couplets, Bigeminy, Trigeminy, Ventricular Tachycardia, Ventricular Fibrillation, PVC s per minute, Runs, Ventricular Rhythm RESPIRATION (ECG) Range: 4 to 199 BPM Accuracy: ± 2% or 2 breaths per minute whichever is greater from 4 to 150 BPM, ± 4% from 151 to 199 BPM Lead: I or II NON-INVASIVE BLOOD PRESSURE Technique: Oscillometric Systolic Range: Adult: 55-235 mmhg, Pediatric: 55-160 mmhg, Neonate: 45-120 mmhg Diastolic Range: Adult: 30-200 mmhg, Pediatric: 30-150 mmhg, Neonate: 20-100 mmhg Systolic Accuracy: Mean Error less than ± 5 mmhg, standard deviation less than ± 8 mmhg Diastolic Accuracy: Mean Error less than ± 5 mmhg, standard deviation less than ± 8 mmhg Pulse Rate Range: Adult/Pediatric: 35 to 245 BPM Neonate: 70 to 245 BPM

Pulse Rate Accuracy: ±3 BPM or 3% whichever is greater Connector Type: Rectus Cuff Inflation: Volume of 500 cc to 300 mmhg in 35 sec TEMPERATURE Scale: Selectable C or F Range: 15 to 45 C / 59 to 113 F (T1 and T2) 0 C to 5.5 C / 0 F to 9.9 F (Delta T) Accuracy: ± 0.1 C (15 C to 45 C) exclusive of probe errors. ± 0.2 F (59 F to 113 F) exclusive of probe errors. PULSE OXIMETRY Masimo SET SpO2 Accuracy Saturation with no motion conditions Adult/Pediatric: 70% to 100% ± 2 digits SpO2, 0 to 69% unspecified Neonate: 70% to 100% ± 3 digits SpO2, 0 to 69% unspecified Ear Sensor (Adult/Pediatric): 70% to 100% ± 4 digits SpO2, 0 to 69% unspecified Masimo SET SpO2 Accuracy Saturation during motion conditions Adult/Pediatric/Neonate: 70% to 100% ± 3 digits SpO2 Response Time: 18 seconds to 95% of final step of % SpO2 value from 60-95% at 75 BPM. Averaging set at 8 seconds. Pulse Rate Range Masimo with no motion conditions Adult/Pediatric/Neonate: 30-235 ±3 BPM, Ear Sensor (Adult/Pediatric) 30-235 ± 3 BPM Pulse Rate Range Masimo during motion conditions Adult/Pediatric/Neonate: 30-235 ±5 BPM Low Perfusion Performance Masimo: > 0.02% Pulse Amplitude and % Transmission > 5% / Saturation (%SpO2) ± 2 digits; Pulse ± 3 digits Nellcor OxiMax SpO2 Saturation Accuracy Adult/Pediatric/Neonate: 70% to 100% ± 3 digits Pulse Rate Range Nellcor: 20-249 ±3 BPM IBP Range: Sys/Dia/Mean -30 to +300 mmhg Accuracy: ± 2 mmhg or 2% whichever is greater Scale: -10 to 10, 0-20, 0-40, 0-160, 0-225, 0-320, 60-140 mmhg Zero Range: ± 120 mmhg Excitation: 5V DC ± 2% Frequency Response: DC to 16 Hz ± 1Hz, -3db RECORDER Speed: 3.125, 6.25, 12.5, 25 mm, and 50 mm/sec Note: 3.125 speed is for CO2/Resp only. CO2 (MICROSTREAM ) Range: 0 99 mmhg

Accuracy: 0 38 mmhg ± 4 mmhg 39 99 mmhg ± 12% (0 20 min) 0 38 mmhg ± 2 mmhg 39 99 mmhg ± 5% +.08% for every 1mmHg above 40 mmhg (> 20 min) Respiration Rate: 0-150 breaths per minute Respiration Accuracy: ± 1 breath per minute from 0 40 BPM ± 2 BPM from 41 70 BPM ± 3% from 71 100 BPM ± 5% from 101 150 BPM CO2 Waveform Recognition: 5 mmhg ± 2 mmhg bandwidth Start-up Time: 30 seconds typical Sampling Rate: 50 ml/min ± 7.5 ml/min Auto Zero: <15 seconds at 5, 10, 15 and 60 minutes, then every 60 minutes thereafter. ELECTRICAL RATINGS AC Voltage: 100 240 VAC ± 10%, 50/60 Hz ± 3 Hz Battery Type: Sealed Lead Acid Number of Batteries: 2 Battery Voltage: 12 V Battery Capacity: 2.3 Ah Battery Run Time: 1 hour, 20 min from two fully charged, new batteries at 25 C with ECG, SpO2 and NIBP running at 15 minute intervals Recharge Time: 16 hrs max PHYSICAL DIMENSIONS Monitor Size: 26.7cm H x 30.2cm W x 18.8cm D 10.5" H x 11.9" W x 7.4" D without module 27.2cm H x 30.2cm W x 18.8cm D 10.7" H x 11.9" W x 7.5" D with module Weight: 5.43 kg (11.95 lbs) without optional accessories 7.04 kg (15.52 lbs) with 2 batteries, without optional accessories 0.8 kg (1.75 lbs) module, without optional accessories CARDIAC OUTPUT Range: 0.2 to 20.0 liters/min C.O. Repeatability: ± 2% or 0.02 l/min from the mean value Blood Temp Range: 17.5 C to 43 C (63.5 F to 109.4 F) Blood Temp Accuracy: ± 0.2 C (± 0.4 F) exclusive of probe errors Injectate Temp Range: -1.0 C to 30.0 C (30.2 F to 86 F ) Injectate Temp Accuracy: ± 0.2 C (± 0.4 F) exclusive of probe errors BIS (BISPECTRAL INDEX) Bispectral Index (BIS) Range: 0-99 Signal Quality Index (SQI) Range: 0-100% EMG Range: 30-80dB Suppression Ratio (SR): 0-100% Burst Count: 0-30 Input Impedance: >50 Mohm Noise (RTI): <0.3uV RMS 0.25-50 Hz Input Range: +/- 1mV

EEG Bandwidth: 0.25-100Hz (-3dB) FILTERS (ON) High Pass: 2.0 Hz (-3dB) Low Pass: 70 Hz (-3dB) Notch: 50 Hz and 60 Hz FILTERS (OFF) High Pass: 0.25 Hz (-3dB) Low Pass: None Notch: None MAC (MINIMUM ALVEOLAR CONCENTRATION) The Spectrum OR shall compute the uncorrected MAC value for all agents supported by the Gas Module SE using the following formula: Where AA is the anesthetic agent in use, ET AA is the end-tidal agent concentration, x(aa) is a clinically derived coefficient based on anesthetic agent (known as 1MAC values), ET N2O is the end-tidal N2O concentration and x(n2o) is a clinically-derived coefficient for N2O (also known as the 1MAC value). X(Isoflurane) = 1.15% X(Halothane) = 0.77% X(Sevoflurane) = 2.1% X(Desflurane) = 7.3% X(Enflurane) = 1.7% X(N2O) = 105% The uncorrected MAC value is not corrected for ambient pressure (altitude & barometric effects), patient age, patient core temperature or any other individual factors influencing the effect of volatile anesthetic agents. Reference Source: EN ISO 21647:2004 Medical electrical equipment- Particular requirements for the basic safety and essential performance of respiratory gas monitors. Vigilance Interface: Supports the Vigilance IFM out communication protocol in accordance with Edwards Lifesciences specification ELS 1291 RevF Soma Technology, Inc. acknowledges all registered trademarks of manufacturers listed. The technical data given in this publication are for general information and are subject to change without notice.