Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Similar documents
SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Function Manual SIMATIC HMI TP900. Operator Panel.

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

MICROMASTER Encoder Module

KRF EMC Filters Installation, Operation and Maintenance Manual

Power Injector 1520 Series

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Series CT7N Bimetallic Overload Relays

Photovoltaic Module Installation Manual (IEC)

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

llen-bradley 194R-HM4-NFPA3

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Trusted 40 Channel 120 Vac Digital Input FTA

SIMATIC. ET 200S distributed I/O 2AO U HS analog electronic module (6ES7135-4FB52-0AB0) Preface. Properties 1. Parameters 2.

Photovoltaic Module Installation Manual (IEC)

Installation Manual Original Instructions - IW4001

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

SIMATIC. ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Preface. Properties 1. Parameters 2. Error and system messages 3

Trusted 40 Channel 120 Vac Digital Input FTA

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

SIREC P, PA, L, LA. Manual

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Cyclo Series. user manual. MartinArchitectural

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Immersion Pumps HCT (High Chem) sealless

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

AS09..S 3-pole Contactors - Spring Terminals

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Trusted 40 Channel Analogue Input FTA

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector Installation Instructions

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

SQM40/41 Actuators for air and gas dampers

Minicontactorrelay,2NO/2NC,DCoperated

Backlight Replacement

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

.Power Distribution Center. PD-1. Instruction Manual

Fibre Optic Modem ODW-622

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

EMC Solutions Noise filtering

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

LED Driver Linear / area fixed output

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

LONWORKS Fibre Optic Converter

3 line filters for converters and power electronics

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

MS2540 Current Loop Receiver with RS485 Communication

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

DS1 Cross-Aisle Panel

LED Thunder S-150 Code 1097

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

4 Wiring Brochure Wiring and installation of specific control


LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

Operating Instructions Dimmer for V Incandescent Lamps

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

3 Cleaning. 4 Technical data

S Regulators. Supplement 1. Contents. Control Replacement Assembly Installation Instructions Supplement

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

ODW-621. RS-232 Point-to-point applications

NEA WIRING CENTRE NEA HT 230V /24 V

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

Fibre optic router for TP/FT-10 LRW-112PP

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Installation Guide. CVC 300 Component Video and HDTV to RGB Converter Rev. B 12 08

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Datasheet - SRB301LC 24VAC/DC

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

GV2ME. Main. Device short name. Device application

EMC filters. 4-line filters for installations and systems Rated current 6 to 125 A. Date: January 2006

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

LONWORKS Fibre Optic Router

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Product Data Sheet 4656 ZW

Transcription:

Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s

Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical specifications 6 Control version V2.5 07/07 A5E01347987A

Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Prescribed Usage Trademarks Note the following: WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 48 48 90327 NÜRNBERG GERMANY A5E01347987A P 09/2007 Copyright Siemens AG 2007. Technical data subject to change

Table of contents 1 Safety information... 7 1.1 Warnings...7 1.2 Safety and operating instructions...8 2 General... 9 3 Mechanical installation... 15 3.1 General...15 3.2 Dimension drawings...16 4 Electrical installation... 19 5 Maintenance and servicing... 25 6 Technical specifications... 27 Operating Instructions, 07/07, A5E01347987A 5

Table of contents 6 Operating Instructions, 07/07, A5E01347987A

Safety information 1 1.1 Warnings WARNING Hazardous voltages are present when electrical equipment is in operation. Severe personal injury or substantial material damage may result if these warnings are not observed. Only qualified personnel are permitted to work on or around the equipment. This personnel must be thoroughly familiar with all the warnings and maintenance procedures described in these operating instructions. Correct and safe operation of this device assumes correct transportation, storage, setup, and installation, as well as careful operation and maintenance.. National safety guidelines must be observed. Operating Instructions, 07/07, A5E01347987A 7

Safety information 1.2 Safety and operating instructions 1.2 Safety and operating instructions DANGER This equipment is used in industrial high-voltage installations. During operation, this equipment contains rotating and live, bare parts. For this reason, they could cause severe injury or significant material damage if the required covers are removed, if they are used or operated incorrectly, or have not been properly maintained. When the machines are used in non-industrial areas, the installation location must be protected against unauthorized access (protective fencing, appropriate signs). Prerequisites Those responsible for protecting the plant must ensure the following: The basic planning work for the plant and the transport, assembly, installation, commissioning, maintenance, and repair work is carried out by qualified personnel and/or checked by experts responsible. The operating manual and machine documentation are always available. The technical specifications regarding the applicable installation, connection, environmental, and operating conditions are always observed. The plant-specific assembly and safety guidelines are observed and personal protection equipment is used. Unqualified personnel are forbidden from using these machines and working near them. This operating manual is intended for qualified personnel and only contain information and notes relating to the intended purpose of the machines. The operating manual and machine documentation are written in different languages as specified in the delivery contracts. Note We recommend engaging the support and services of your local Siemens service center for all planning, installation, commissioning and maintenance work. 8 Operating Instructions, 07/07, A5E01347987A

General 2 Description are drive components designed for installation in electrical systems or machines. They must not be used in other electrical consumers since this could destroy the devices. WARNING must only be connected to symmetrical networks otherwise they can be destroyed. Operating Instructions, 07/07, A5E01347987A 9

General Assignment of line harmonics filter and converter G130/G150 Table 2-1 Assignment of line harmonics filter, converter G130/G150 Line harmonics filter Associated converter G130 1) Associated converter cabinet G150 2) 6SL3000-0JE36-1AA0 6SL3000-0JE38-4AA0 Supply voltage 380 480 V 3 AC 6SL3310-1GE35-0AA0 6SL3310-1GE36-1AA0 6SL3310-1GE37-5AA0 6SL3310-1GE38-4AA0 6SL3710-1GE35-0_A0 6SL3710-1GE36-1_A0 6SL3710-1GE37-5_A0 6SL3710-1GE38-4_A0 Rated power of the converter 250 kw 315 kw 400 kw 450 kw 6SL3000-0JE41-0AA0 6SL3310-1GE41-0AA0 6SL3710-1GE41-0_A0 560 kw 6SL3000-0JH33-3AA0 6SL3000-0JH34-7AA0 Supply voltage 500 600 V 3 AC 6SL3310-1GF32-6AA0 6SL3310-1GF33-3AA0 6SL3310-1GF34-1AA0 6SL3310-1GF34-7AA0 6SL3710-1GF32-6_A0 6SL3710-1GF33-3_A0 6SL3710-1GF34-1_A0 6SL3710-1GF34-7_A0 160 kw 200 kw 250 kw 315 kw 6SL3000-0JH35-8AA0 6SL3310-1GF35-8AA0 6SL3710-1GF35-8_A0 400 kw 6SL3000-0JH38-1AA0 6SL3000-0JH33-3AA0 6SL3000-0JH34-7AA0 6SL3310-1GF37-4AA0 6SL3310-1GF38-1AA0 6SL3710-1GF37-4_A0 6SL3710-1GF38-1_A0 Supply voltage 660 690 V 3 AC 6SL3310-1GH32-6AA0 6SL3310-1GH33-3AA0 6SL3310-1GH34-1AA0 6SL3310-1GH34-7AA0 6SL3710-1GH32-6_A0 6SL3710-1GH33-3_A0 6SL3710-1GH34-1_A0 6SL3710-1GH34-7_A0 500 kw 560 kw 250 kw 315 kw 400 kw 450 kw 6SL3000-0JH35-8AA0 6SL3310-1GH35-8AA0 6SL3710-1GH35-8_A0 560 kw 6SL3000-0JH38-1AA0 6SL3310-1GH37-4AA0 6SL3310-1GH38-1AA0 6SL3710-1GH37-4_A0 6SL3710-1GH38-1_A0 710 kw 800 kw 1) With G130: only in conjunction with a line reactor and line contactor/circuit breaker (see table below) 2) With G150: only in conjunction with options L23 (line reactor) and L13 (line contactor)/l26 (circuit breaker) 10 Operating Instructions, 07/07, A5E01347987A

General Table 2-2 Assignment of converter G130, line contactor, and line reactor SINAMICS G130 Rated power Line contactor/circuit breaker Line reactor Supply voltage 380 480 V 3 AC 6SL3310-1GE35-0AA0 250 kw 3RT1476-6AP36 6SL3000-0CE35-1AA0 6SL3310-1GE36-1AA0 315 kw 3RT1476-6AP36 6SL3000-0CE36-3AA0 6SL3310-1GE37-5AA0 400 kw 3 x 3RT1466-6AP36 6SL3000-0CE37-7AA0 6SL3310-1GE38-4AA0 450 kw 3WL1110-2BB34-4AN2-Z, Z=22 6SL3000-0CE38-7AA0 6SL3310-1GE41-0AA0 560 kw 3WL1210-2BB34-4AN2-Z, Z=22 6SL3000-0CE41-0AA0 Supply voltage 500 600 V 3 AC 6SL3310-1GF32-6AA0 160 kw 3RT1466-6AP36 6SL3000-0CH32-7AA0 6SL3310-1GF33-3AA0 200 kw 3RT1466-6AP36 6SL3000-0CH33-4AA0 6SL3310-1GF34-1AA0 250 kw 3RT1476-6AP36 6SL3000-0CH34-8AA0 6SL3310-1GF34-7AA0 315 kw 3RT1476-6AP36 6SL3000-0CH34-8AA0 6SL3310-1GF35-8AA0 400 kw 3RT1476-6AP36 6SL3000-0CH36-0AA0 6SL3310-1GF37-4AA0 450 kw 3 x 3RT1466-6AP36 6SL3000-0CH38-4AA0 6SL3310-1GF38-1AA0 560 kw 3WL1210-4BB34-4AN2-Z, Z=22 6SL3000-0CH38-4AA0 Supply voltage 660 690 V 3 AC 6SL3310-1GH32-6AA0 250 kw 3RT1466-6AP36 6SL3000-0CH32-7AA0 6SL3310-1GH33-3AA0 315 kw 3RT1466-6AP36 6SL3000-0CH33-4AA0 6SL3310-1GH34-1AA0 400 kw 3RT1476-6AP36 6SL3000-0CH34-8AA0 6SL3310-1GH34-7AA0 450 kw 3RT1476-6AP36 6SL3000-0CH34-8AA0 6SL3310-1GH35-8AA0 560 kw 3RT1476-6AP36 6SL3000-0CH36-0AA0 6SL3310-1GH37-4AA0 710 kw 3 x 3RT1466-6AP36 6SL3000-0CH38-4AA0 6SL3310-1GH38-1AA0 800 kw 3WL1210-4BB34-4AN2-Z, Z=22 6SL3000-0CH38-4AA0 Line system configurations If you want to operate the filter modules with line systems not specified in the table below, please contact our technical department. VDE-compliant line system configuration With directly grounded star point With indirectly grounded star point With isolated star point Operating the line harmonics filter Permitted Permitted Permitted Operating Instructions, 07/07, A5E01347987A 11

General Line harmonics filter Figure 2-1 Line harmonics filter in the delivery condition with degree of protection IP20 12 Operating Instructions, 07/07, A5E01347987A

General Figure 2-2 Line harmonics filter with mounted canopy and degree of protection IP21 Operating Instructions, 07/07, A5E01347987A 13

General 14 Operating Instructions, 07/07, A5E01347987A

Mechanical installation 3 3.1 General WARNING To ensure that the devices operate safely and reliably, they must be properly installed and commissioned by qualified personnel, taking into account the warnings provided in these operating instructions. In particular, the general and national installation and safety guidelines for high-voltage installations (e.g. VDE the Union of German Technical Engineers) as well as the guidelines relating to the proper use of tools and personal protective equipment must be observed. Death, serious injury, or substantial material damage can result if these factors are not taken into account. Note A ventilation clearance of at least 60 mm at the rear of the line harmonics filter must be observed. Natural convection must not be obstructed. Installing the canopy to increase the degree of protection to IP21 The canopy supplied can be installed on the line harmonics filter to increase the degree of protection to IP21. To install it, the spacers supplied with the line harmonics filter must be screwed into the holes otherwise used for the cover. Use the screws you removed earlier (incl. washers and retaining rings) to secure the canopy. Operating Instructions, 07/07, A5E01347987A 15

Mechanical installation 3.2 Dimension drawings 3.2 Dimension drawings Figure 3-1 Dimension drawing of line harmonics filter: 6SL3000-0JE36-1AA0, 6SL3000-0JH33-3AA0 16 Operating Instructions, 07/07, A5E01347987A

Mechanical installation 3.2 Dimension drawings Figure 3-2 Dimension drawing of line harmonics filter: 6SL3000-0JE38-4AA0, 6SL3000-0JH34-7AA0 Operating Instructions, 07/07, A5E01347987A 17

Mechanical installation 3.2 Dimension drawings Figure 3-3 Dimension drawing of line harmonics filter: 6SL3000-0JE41-0AA0, 6SL3000-0JH35-8AA0, 6SL3000-0JH38-1AA0 18 Operating Instructions, 07/07, A5E01347987A

Electrical installation 4 Important safety precautions WARNING The line harmonics filters are operated with high voltages. All connection procedures must be carried out when the cabinet is de-energized. All work on the device must be carried out by trained personnel only. Death, serious injury, or substantial material damage can result if these warnings are not taken into account. Work on an open device must be carried out with extreme caution. The power and control terminals may be live even when the motor is not running. Due to the capacitors, dangerously high voltage levels are still present in the cabinet up to five minutes after it has been disconnected. For this reason, the cabinet should not be opened until a reasonable period of time has elapsed. The operator is responsible for ensuring that the motor, converter, and other devices are installed and connected in accordance with the recognized technical rules in the country of installation and applicable regional guidelines. Special attention should be paid to cable dimensioning, fuses, grounding, shutdown, disconnection, and overcurrent protection. If an item of protective gear trips in a branch circuit, a leakage current may have been disconnected. To reduce the risk of fire or an electric shock, the current-carrying parts and other components in the cabinet unit should be inspected and damaged parts replaced. When an item of protective gear trips, the cause of the trip must be identified and rectified. When the line harmonics filter is connected to a network with a line frequency of 60 Hz, the cable jumpers must be removed in accordance with the instructions in the device (see interface overviews below). Tightening torques for connecting current-carrying parts When securing connections for current-carrying parts (e.g. copper bars), you must observe the following tightening torques. Table 4-1 Tightening torques for connecting current-carrying parts Screw M6 M8 M10 M12 Torque 6 Nm 13 Nm 25 Nm 50 Nm Operating Instructions, 07/07, A5E01347987A 19

Electrical installation Interface overview Figure 4-1 Connection overview of the line harmonics filter (600 mm wide) 20 Operating Instructions, 07/07, A5E01347987A

Electrical installation Figure 4-2 Connection overview of the line harmonics filter (800 mm wide) Operating Instructions, 07/07, A5E01347987A 21

Electrical installation Figure 4-3 Connection overview of the line harmonics filter (1000 mm wide) 22 Operating Instructions, 07/07, A5E01347987A

Electrical installation Connecting the line harmonics filter for SINAMICS G150 L 1 L 2 L 3 N PE M 3 ~ Figure 4-4 Connecting the line harmonics filter for SINAMICS G150 Operating Instructions, 07/07, A5E01347987A 23

Electrical installation Connecting the line harmonics filter for SINAMICS G130 L 1 L 2 L 3 N PE M 3 ~ Figure 4-5 Connecting the line harmonics filter for SINAMICS G130 Thermostatic switch connection A thermostatic switch is installed to protect the integrated reactors against overload. Its floating contacts must be integrated in the fault chain on the line side. Table 4-2 Thermostatic switch connection Terminal Description of function T1 Thermostatic switch connection T2 Thermostatic switch connection Max. connectable cross-section: 6 mm² (AWG 8) Rewiring when the line frequency is changed from 50 Hz to 60 Hz When the line harmonics filter is connected to a network with a line frequency of 60 Hz, the cable jumpers must be removed in accordance with the instructions in the device (see the interface overviews). 24 Operating Instructions, 07/07, A5E01347987A

Maintenance and servicing 5 Maintenance and servicing are not carried out for the line harmonics filter. If a fault occurs, please contact Technical Support. Technical support We offer technical support in both German and English for products, systems, and solutions deployed in drive and automation systems. In special cases, help is available from professional, trained, and experienced specialists via teleservice and video conferencing. Free Contact providing you with free technical support In Europe / Africa Tel.: +49 (0)180 50 50 222 Fax: +49 (0)180 50 50 223 Internet: http://www.siemens.de/automation/support-request in America Tel.: +14232622522 Fax: +14232622289 E-mail: simatic.hotline@sea.siemens.com Asia / Pacific region Tel.: +86 1064 757575 Fax: +86 1064 747474 E-mail: adsupport.asia@siemens.com Operating Instructions, 07/07, A5E01347987A 25

Technical specifications 6 General technical specifications Table 6-1 General technical specifications Temperature class VDE: H UL: H Cooling method AN: Air cooling by means of natural convection Ambient conditions Operation Storage Transport Ambient temperature 0 C to +40 C -25 C to +55 C -25 C to +70 C Humidity range (noncondensing) Corresponds to class: Mechanical stability Vibrational load: - Displacement - Acceleration 5% to 95% 3K3 to IEC 60 721-3-3 0.075 mm at 10 Hz to 58 Hz 10 m/s² at > 58 Hz to 200 Hz 5% to 95% 1K4 to IEC 60 721-3-1 1.5 mm at 5 Hz to 9 Hz 5 m/s² at > 9 Hz to 200 Hz 5% to 95% at 40 C 2K3 to IEC 60 721-3-2 3.1 mm at 5 Hz to 9 Hz 10 m/s² at >9 Hz to 200 Hz Shock load: Acceleration 100 m/s² at 11 ms 40 m/s² at 22 ms 100 m/s² at 11 ms Detailed technical specifications Table 6-2 Line harmonics filter, 380 V 480 V Category Unit Order number: 6SL3000-0JE36-1AA0 0JE38-4AA0 0JE41-0AA0 Rated power kw 315 450 560 Rated voltage - can be rewired to: V 380 V to 415 V 3 AC ±10% at 50 Hz 440 V to 480 V 3 AC ±10% at 60 Hz Rated current A 500 700 900 Power loss kw 1.0 1.5 2.0 Connection cross-sections Maximum: DIN VDE AWG / MCM Mounting holes mm 2 mm 2 x 240 2 x (500) 15 (2 holes) 2 x 240 2 x (500) 15 (2 holes) 2 x 240 2 x (500) 15 (2 holes) Protective conductor connection Securing bolt M12 (3 bolts) M12 (3 bolts) M12 (3 bolts) Weight kg 450 600 830 Dimensions (W x H x D) mm 600 x 1700 x 540 800 x 1700 x 540 1000 x 1700 x 540 Operating Instructions, 07/07, A5E01347987A 27

Technical specifications Table 6-3 Line harmonics filter, 500 V 690 V, part 1 Category Unit Order number: 6SL3000-0JH33-3AA0 0JH34-7AA0 0JH35-8AA0 Rated power kw 315 450 560 Rated voltage - can be rewired to: V 500 V to 690 V 3 AC ±10% at 50 Hz 500 V to 690 V 3 AC ±10% at 60 Hz Rated current A 290 400 520 Power loss kw 0.8 1.0 1.5 Connection cross-sections Maximum: DIN VDE AWG / MCM Mounting holes mm 2 mm 2 x 240 2 x (500) 15 (2 holes) 2 x 240 2 x (500) 15 (2 holes) 2 x 240 2 x (500) 15 (2 holes) Protective conductor connection Securing bolt M12 (3 bolts) M12 (3 bolts) M12 (3 bolts) Weight kg 450 600 830 Dimensions (W x H x D) mm 600 x 1700 x 540 800 x 1700 x 540 1000 x 1700 x 540 Table 6-4 Line harmonics filter, 500 V 690 V, part 2 Category Unit Order number: 6SL3000-0JH38-1AA0 Rated power kw 800 Rated voltage V - can be rewired to: Rated current A 710 Power loss kw 2.0 Connection cross-sections Maximum: DIN VDE AWG / MCM Mounting holes Protective conductor connection Securing bolt mm 2 mm 2 x 240 2 x (500) 15 (2 holes) M12 (3 bolts) Weight kg 830 Dimensions (W x H x D) mm 1000 x 1700 x 540 500 V to 690 V 3 AC ±10% at 50 Hz 500 V to 690 V 3 AC ±10% at 60 Hz 28 Operating Instructions, 07/07, A5E01347987A

Siemens AG A5E01347987A Automation and Drives Large Drives PO Box 4743 90025 NUREMBERG GERMANY www.ad.siemens.com