Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

Similar documents
Main House Technical Specification

DEREHAM MEMORIAL HALL

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

TECHNICAL SPECIFICATIONS

New Theatre Royal Lincoln Technical Information

Technical Information

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

Technical Specification for the Alley Theatre, Strabane

Theatre Technical Specifications

JERWOOD VANBRUGH THEATRE

Technical Specification

INFORMATION FOR VISITING COMPANIES

Technical Specification

Technical Specifications Updated 01/10/2017. Stage

Technical Specification Pavilion Dance

The Haymarket Basingstoke Technical Specifications

Theatre Technical Specification

Stage. Get In & Parking

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Technical requirements & conditions for hirers

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Specifications Nov 2016

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Dr JOHN GALLAGHER CONCERT CHAMBER

Matt Dann Cultural Centre

Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

RPAC REDLANDS PERFORMING ARTS CENTRE

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

HIRE AND TECHNICAL INFORMATION

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Technical Specification. Updated: April 2016

Technical Specifications

CHELSEA THEATRE. Technical Specifications

The Georgian Theatre Royal Technical Information For Visiting Companies

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Main House Technical Specifications

ISLAND HALL TECHNICAL INFORMATION

Pleasance London Main House Visiting Company Information Pack May 2017

Technical Specification Ardhowen Theatre

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Darlington Hippodrome Technical Specification

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATION

Technical specifications Main theatre. Sound

ROSE THEATRE BASEMENT

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Technical Director of Production Andrew Quick Ext 252

Information for Incoming Companies

Arlington Arts Tech Spec 2018

Technical Data Sheet

Technical Information

WYCOMBE SWAN Wycombe Arts Management Ltd registered in England and Wales No Registered Office: 16 High Holborn, London, WC1V 6BX

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

TECHNICAL SPECIFICATIONS

2017 TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Summary. Access and Parking

Latrobe Performing Arts Centre

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Lighthouse Theatre Technical Specification

Technical Specification

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

UNIVERSITY CONCERT HALL. Technical Specification

MAIN THEATRE TECHNICAL SPECIFICATION

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Technical Specifications

Hopgood Theatre NOARLUNGA CENTRE

John Leslie Theatre. Technical Specifications. Updated July 2018

Source 4 Junior Zoom Profile 575W 14 part of universal rig

Technical Specification (Studio Theatre)

HIRERS INFORMATION PACK For further technical information or enquiries please contact:

Hirers Technical Information Pack

Salisbury Arts Centre Technical Specification v Page 1 of 7

Visy Theatre technical information and general specifications 2019

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Main Stage Technical Specs - Hall #2

COURTYARD!!!!! THEATRE

Notes for Lighting and Sound Technicians (A Supplement to Notes for Playing Companies)

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Technical Specification Ver 01/16

ROSE THEATRE MAIN THEATRE

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Barney Simon Theatre Technical Specifications

Project manager (PM): Pamela Næss Mail: Phone:

Esso BHP Billiton Wellington Entertainment Centre

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

MAIN AUDITORIUM TECHNICAL INFORMATION

Technical Specifications - Theatre

CENTRE FOR PERFORMING ARTS

Backstage Accommodation (Ground Floor Mezzanine Level 1 Floor above Loading Bay)

The Anvil Technical Specifications

Transcription:

Derby Theatre Technical Information Main Stage Derby Theatre 15 Theatre Walk St. Peters Quarter Derby DE1 2NF 01332 593900 L.Barkes@derby.ac.uk technical@derbytheatre.co.uk www.derbytheatre.co.uk

Introduction Please note that Derby Theatre abides by the TMA/BECTU Code Of Conduct for Get-Ins, Fit-Ups and Get Outs and expects Visiting Companies to do the same. Technical Requirements and a lighting plan must be received at least two weeks before you visit, otherwise a pre-rig cannot be guaranteed. Please inform us at least three weeks in advance if your performance uses Strobe lighting, Naked flames, Pyrotechnics or any other special effects or equipment. Please note that if Naked Flame or Pyrotechnics are used, we require full details on usage and copies of your Method Statement and Risk Assessments before liaising with our Fire Officer. We may request to see PAT test certificates or conduct a visual inspection at any time. The management reserves the right to refuse any equipment being used if thought to be unsafe in anyway. Proof of test may be required. If we deem a PAT test is required, then we reserve the right to test and charge for this service. Permission to use and advice given by Derby Theatre Production office does not constitute as legal advice. It is in the interest of your safety, the safety of your cast, company, audience, guests and Derby Theatre staff that ALL your electrical equipment is regularly checked and tested to conform to the 1989 EAW legislation (this includes lighting & sound equipment, special effects, extension leads, kettles, hair dryers, portable power tools, illuminated music stands etc...).further information on electrical maintenance and portable appliance testing, can be obtained free in a booklet from : The Institute of Electrical Engineers, PO Box 96, Stevenage, Herts., SG1 2SD. (C) indicates that this item carries a contra charge. Please contact us for pricing General Information Main Auditorium - 535 seats, single rake of 15 Rows. The main stage has a Forestage lift, this also forms the Orchestra pit. Please inform us in advance if you wish to use the Orchestra Pit. Access is either via the substage or the Auditorium. The orchestra pit lift can be set at various heights (Further information should be sought). Main Stage access is via a lift. Only one side of the lift is solid. All items must be tied off before travel.

Lift Get In height - Lift Floor width - Lift Floor Depth - WLL of Lift - 6000mm 2600mm 1970mm 1500kg Scenic items outside of these dimensions will not fit in our lift. Please contact the Production office for further information. We will not be held responsible for items not conforming to these measurements. Dressing Rooms Number 1 Number 2 Number 3 Number 4 Number 5 Number 6 Seats 4, with En Suite Bathroom Seats 4, Hand Basin Seats 6, En Suite Shower Seats 6, En Suite Shower Seats 4, (Company office) Seats 8, (Please check availability) Additional Showers and Toilets are found off the Dressing room Corridor. Access to stage from All dressing rooms is via stairs. Please contact the Production Office to discuss further. As part of the contract, you will be offered 4 Car Park spaces in the Theatre Car Park. Please provide Stage Door with the registration numbers when you arrive. It is the responsibility of the visiting company manager that only 4 spaces are used. Dimensions Proscenium Width (back) - Proscenium Width (front) - Proscenium height - Height from Stage to underside of Grid - Setting Line to back wall - 10450mm 10175mm 5635mm 14855mm 9500mm

Setting Line to US Counterweight bar - Setting Line to Front edge of Stage - Setting Line to DS edge of Forestage lift - 8700mm -900mm -3520mm Rigging Single Purchase Counterweight Bars - 28 Length of Counterweight Bars - WLL of Counterweight Bars - Diameter of Counterweight Bars - 14000mm 400kg UDL 50mm OD Various Strops, Shackles, Steels, chain blocks and other pieces of rigging are available, please contact the Production Office to discus further. All our rigging is checked in accordance with Lifting Operations and Lifting Equipment Regulations 1998. Steel deck units are also available to hire - 2400mm x 1200mm Whilst we predominantly use Black Serge Hard masking (6000 x 2000mm) as legs, we do have various soft Black Serge legs also. Please contact the Production Office should you need the use of Soft Black Legs. White BP screen, Cyc and Gauzes are also available. Please check with Production Office for Availability. Full Blacks, Black Half Tabs and House Tabs are also available. DSM operation can be from Control Room (At Back of Auditorium) or DSL. Full Q Light and Infa Red camera set up can be supplied. Lighting: Control Dimmers 2.5k Strand LD90 Dimmers - 180 Ways 5k Strand LD90 Dimmers - 12 Ways Non Dim Circuits - 32

Strand 6 Way Dimmer (63A, 1Φ Ceeform Inlet) - 3 250A 3Φ Power-Lock Touring Power in SL Wing - 1 18 way IWB with 15a outlets. (12000mm) - 4 32a 3Φ N+E Ceeform DSR - 1 63a 1Φ Ceeform USR - 2 13a 1Φ Ceeform USR - 1 63a 1Φ Ceeform USL - 1 32a 3Φ N+E Ceeform USL Wing - 1 The stage is covered with full Working Light and performance blue light, operated from DSL and control room. Lighting Control ETC Eos Lighting Desk - 1 ETC Ion Lighting Desk - 1 ETC Fader Wing - 1 ETC wireless riggers remote - 1 17 Illyama Touch Screens - 2 Various lengths of 15 amp, 16 amp TRS, Scroller cable, DMX Cable and socapex are available at no extra cost. Lighting: Lanterns Profiles ETC Source 4 Zoom 15/30 Profile 750w (bridge 3) - 12 ETC Source 4 Zoom 15/30 Profile 750w - 18 ETC Source 4 Zoom 25/50 Profile 750w - 16 ETC Source 4 Jnr 25/50 Profile 575w - 4

ETC Source 26 Profile 750w - 4 ETC Source 0 Lens Tu e for a o e - 3 Selecon Pacific (red Base) Profile 1k - 6 Selecon Pacific 14/35 Lens Tube (B sized Gobo) - 6 Selecon Pacific 23/50 Lens Tube (A size Gobo) - 6 Fresnels Selecon Arena Fresnel 2k - 10 Selecon Rama Fresnel 1k - 30 ETC Source 4 Fresnel 750w - 10 Parcans ETC Source 4 Par 750w - 40 Par 64 Long Nose (CP60, 61, 62 lamps available) - 20 Strand Beam Light 500w - 2 (C) Selecon Lui Asymmetric Flood 1k - 10 ADB 4 Way Asymmetric Flood - 8 Intelligent VariLite VL770 Spot - 2 (C) Robe ColorWash 750AT - 2 (C) Scrollers Apollo Smart Colour 10 (Selecon 2K) - 10 (C) Apollo Smart Colour 7.25 (Rama 1k, S Zoom) - 6 (C) Apollo Smart Colour 5.25 (Source, Not Zooms) - 6 (C) Apollo Smart Colour scroller PSU - 2 (C)

We stock arious reak ups, architectural and scenic go o s. Please contact the production office if you have specific requirements. All lanterns are equipped with Colour frame, Barndoors/Shutter as appropriate. We also stock Gobo Holders for ETC source four as well as others. Please contact the production office if you have specific requirements. Colour is not provided by Derby Theatre unless agreed in advance. Effects MDG co2 Low Fog Machine 1 (C) Le Maitre G300 DMX Smoke Machine/Hazer - 1 (C) Jem ZR33 Smoke Machine - 1 (C) Le Maitre MVS hazer - 1 (C) Sound Speaker System D&B Audiotechnik Q7 Speaker (FOH L&R) - 4 D&B Audiotechnik QSub Speaker (FOH L&R) - 4 D&B Audiotechnik E12-D Speaker (FOH Centre) - 1 D&B Audiotechnik MAX12 Monitors - 4 EM Acoustic EM61passie loudspeaker - 2 Amplification / Mixing D&B Audiotechnik D12 Amplifier (for FOH PA) - 2 D&B Audiotechnik D6 Amplifier (for Max 12/E12D) - 3 HH V800 Amplifier - 2 Yamaha M7CL 48 Channel desk - 1 Allan & Heath Mix Wizard 14:4:2 desk - 1

Playback & Outboard Denon DN-C620 Cd Player - 2 Tascam MD350 Minidisc Player - 2 Roland Modular Rack 32 XLR in, 8 XLR out - 1 Roland Modular Rack 8 XLR in, 32 XLR out - 1 Yamaha SPX2000 Dual Channel Graphics - 1 Microphones & Accessories Sennheiser ew300 G3 Radio Microphones - 12 (C) Transmitter packs for above system - 12 (C) Hand Held Transmitter for above system - 2 (C) Shure SM58 Microphone - 2 (C) Shure SM57A Microphone - 3 (C) Shure PGDMK6 Drum Mic kit - 1 (C) AR133 Active BSS DI box - 6 (C) Tall Telescopic Mic Stands - 5 Short Telescopic Mic Stands - 5 Audio Technica Pro 45-2 (C) Various Audio cables and stage boxes are available. Please contact the Production office to discuss your requirements. The Stage, Sound desk position (back right of Auditorium) and control room are linked via XLR tie Lines. Q lights, DMX, CANS, VGA and HDMI are also linked between Sound position and Control Room.

Wardrobe Top loading washer 1 Front Loading washing machine 1 Tumble dryer 1 Spinner 1 Large hot box 1 Small hot box 1 We do not supply powder Support / Safety This Technical Specification should be used as a guide only. The Venue does not guarantee the availability of any of the items listed. If you specifically require the use of any of the equipment, prior notice musty be given. Only water in plastic bottles may be taken onto the stage. Technical Support At all times when using the Theatres facilities, a Technician will oversee practice and use. Technic l operators for lighting, sound and rigging of shows are available on request in advance, please contact the Production Office with your staffing requirements for get -in, performance and get -out. Appointments can be made with our technical staff for visits to the theatre space depending on availability of staff and theatre. All performance companies using Der y Theatre s theatre / auditorium must ensure and demonstrate if required that they can use and operate the theatre s equipment in a safe and competent manner. When raising and lowering counterweight sets you must make sure that it is carried out by experienced personnel and in a competent manner and that the load is correctly secured, giving an audible warning to stage workers. The load must not exceed the SWL of that particular hemp set and must not exceed the weight that the operators can safely lift. ALL counterweight bars when in a static position must be secured correctly. All scenery, props, costumes etc must conform to fire regulation standards where appropriate and that flame retardants conform to BS3119/3120 BS476 parts 5,6 & 7 (class 1 & 0). Any equipment being brought into the premises must be in a safe condition.

All rigging using ladders / Tallescope s must e conducted in a competent manner and in accordance with current health and safety guidelines. If used stationary, the tallescope must be operated by two people. If the tallescope is used moving, then it must have two people to operate. In both instances one of these people must be trained with current training course for the tallescope. The management reserves the right to control the Sound Pressure Levels of any event. Our SPL limit guideline is 103dBA, but be aware this is only a guide - If a request to reduce the Sound pressure Level at anytime is not adhered to, the management reserves the right to terminate the event and all loss of profits or costs incurred must be covered by the promoter/artist. No fire or pyrotechnics to be used during a performance without prior authorisation from the Technical Manager. It is illegal to smoke anywhere in the building (other than as part of a performance). Under no circumstance must any fire exit or fire exit route be obstructed both internally or externally. It must be the duty of the responsible person in charge of the company to make their colleagues aware of their nearest fire exit and muster point. A full briefing will be carried out by a member of Derby Theatre Staff. Under no circumstances must equipment or cable belonging to Derby Theatre be tampered with, adapted or have its connectors removed without prior permission or consultation with the Derby Theatre Production Office. Please contact L.Barkes@derby.ac.uk or technical@derbytheatre.co.uk if you have further enquiries. Thank you. We look forward to welcoming you to our Theatre