Agilent Technologies Series of RF and Universal Frequency Counter/Timers. Family Overview

Similar documents
SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

Keysight Technologies ad Integrated RF Test Solution

Keysight Technologies RF & Universal Frequency Counter/Timers Migration, Comparison, and Differences Guide

Agilent N5183A MXG Microwave Signal Generator

Agilent N4876A 28 Gb/s Multiplexer 2:1

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

Advanced Test Equipment Rentals ATEC (2832)

Exceptional performance

Agilent N4876A 28 Gb/s Multiplexer 2:1

Agilent Series Harmonic Mixers

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster


Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

Keysight Technologies 53200A Series RF/Universal Frequency Counter/Timers. Data Sheet

Time-Saving Features in Economy Oscilloscopes Streamline Test

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details

Full-featured CW Microwave Counters for Field, Factory or Lab

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Agilent 5345A Universal Counter, 500 MHz

Microwave Counter, Power Meter and DVM in One Portable Package

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Agilent N9344C Handheld Spectrum Analyzer (HSA)

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

Agilent Technologies N5454A Segmented Memory Acquisition for Agilent InfiniiVision Series Oscilloscopes

FlexRay Physical Layer Eye-diagram Mask Testing

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes

Agilent Understanding the Agilent 34405A DMM Operation Application Note

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Logic Analysis Fundamentals

Agilent N9343C Handheld Spectrum Analyzer (HSA)

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Agilent ESA Series Spectrum Analyzers

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

Keysight Technologies Achieve High-Quality Compliance Test Results Using A Top-Quality Test Fixture. Application Note

Keysight Technologies Decoding Automotive Key Fob Communication based on Manchester-encoded ASK Modulation

Digital Storage Oscilloscopes 2550 Series

Agilent 11713A Attenuator/Switch Driver

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

Agilent M9362A-D01-F26 PXIe Quad Downconverter

Keysight Technologies Segmented Memory Acquisition for InfiniiVision Series Oscilloscopes. Data Sheet

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

Portable Performance for Debug and Validation

Agilent 83000A Series Microwave System Amplifiers

Selecting the Right Oscilloscope for Protocol Analysis Applications

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

Agilent E4887A HDMI TMDS Signal Generator Platform

PM 6680B / PM 6681 / PM 6681R

Electrical Sampling Modules

Advanced Test Equipment Rentals ATEC (2832)

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope Wireless LAN Example Application

Agilent N4965A Multi-Channel BERT 12.5 Gb/s Data Sheet

Keysight Technologies Millimeter Wave Frequency Extenders From Virginia Diodes Inc. for the Keysight X-Series Signal Analyzers. Technical Overview

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

GFT Channel Digital Delay Generator

Arbitrary Waveform Generators AWGSYNC01 Synchronization Hub Datasheet

JD725A Cable and Antenna Analyzer - Dual Port

Microwave/Counter/Analyzer with Integrated Power Meter MCA3000 Series Datasheet

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

Agilent E6701G GSM/GPRS and E6704A EGPRS Lab Applications

2 MHz Lock-In Amplifier

Advanced Test Equipment Rentals ATEC (2832)

Fluke PM6690. Frequency Counter/Timer/Analyzer

Datasheet SHF A

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

Agilent V3500A Handheld RF Power Meter

Agilent Series Preselected Millimeter Mixers

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Keysight Technologies RS-232/UART Triggering and Hardware-Based Decode (N5457A) for InfiniiVision Oscilloscopes

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

GFT Channel Slave Generator

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

Data Pattern Generator

Keysight Technologies Oscilloscope Memory Architectures Why All Acquisition Memory is Not Created Equal. Application Note

Synthesized Clock Generator

Agilent Power Meters and Sensors

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster. Application Note

Microwave/Counter/Analyzer & Integrated Power Meter

Keysight Technologies E5500 Series Phase Noise Measurement Solutions

Signal Stability Analyser

Agilent 87075C Multiport Test Set Product Overview

Tektronix Video Signal Generators

Agilent E5100A Network Analyzer

Analog Dual-Standard Waveform Monitor

Technical Datasheet. 8650B Series Universal Power Meters 10 MHz to 50 GHz. 8651B Single Channel 8652B Dual Channel Rev.

Keysight Technologies Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details. Application Note

FlexRay Measurements (Option FLX) for Agilent s InfiniiVision Series Oscilloscopes

Transcription:

Agilent Technologies 53200 Series of RF and Universal Frequency Counter/Timers Family Overview

I never expected a frequency counter to do so much, so fast. Speed, resolution, and accuracy are just the beginning With Agilent 53200 RF and universal frequency counters/timers, you get: More bandwidth 350 MHz baseband frequency 6- or 15-GHz optional microwave channels More resolution and speed 12 digits/sec 20 ps single shot time interval Up to 75,000 frequency readings/sec, 90,000 time interval readings/sec Up to 1M Sa/sec gap-free frequency/timestamp More insight Datalog trend plot Cumulative histogram Built-in math analysis and statistics 1 M reading memory More connectivity LXI-C/Ethernet LAN USB (I/O and memory stick) GPIB interface Optional battery for portability and timebase accuracy More measurement capability (53230A only) Continuous gap-free measurements Basic modulation domain analysis (MDA) and timestamp Optional pulse microwave measurements 53210A: 350 MHz RF Frequency Counter, 10 digit/sec 53220A: 350 MHz Universal Frequency Counter/Timer, 12 digit/sec, 100 ps 53230A: 350 MHz Universal Frequency Counter/Timer, 12 digit/sec, 20 ps 2

Find and resolve problems faster The Agilent 53200 Series frequency counter/timers give you more insight into your signals so you can solve design and manufacturing problems faster: Figure 1. APPLICATION: Crystal/oscillator components How the 53230A helps: Easily observe the stability of your clocks over time Take advantage of continuous/gap-free measurements with timestamps to measure the stability of your clocks over time. See changes in the Allan Deviation over a series of measurements. (Figure 1) On-going insight to measurement data with graphing and built-in analysis All samples per trigger taken continuously with no lag between readings, timestamped for further stability analysis APPLICATION: Communications equipment How the 53200 Series helps: Make and analyze highly accurate jitter and wander measurements without spending a fortune Whether you re taking slow, high precision measurements over a long period of time, or fast measurements over a short time, you can use your Agilent 53200 Series frequency counter as a low-cost, highly accurate jitter and wander analysis solution (Figure 2): See histograms of a block of data Watch trends and changes of your frequency over a series of measurements Use markers to view specific data points Analyze your results with math functions: mean, standard deviation, Allan Deviation, etc. Figure 3. APPLICATION: Radar equipment How the 53230A helps: Minimize errors in your transmitted signals Now there s a low-cost way to verify the accuracy of transmitted signals to increase your confidence in your target data. Use the Agilent 53230A universal frequency counter/ timer to make high-resolution pulse/burst microwave frequency measurements, (Figure 3) including carrier frequency, PRI, PRF and PW. Compared to other pulsed RF measurement solutions, the 53230A is: Easier to use Lower cost Pulse width (t) Figure 2. T 0 Pulse repetition period (T) 3

Agilent Technologies 53200 Series of RF and Universal Frequency Counter/Timers Frequency counters are depended on in R&D and in manufacturing for the fastest, most accurate frequency and time interval measurements. The 53200 family of RF and universal frequency counter/timers expand on this expectation to allow you to get the most information, connectivity and new measurement capabilities while building on the speed and accuracy you ve depended on with Agilent s decades of time and frequency measurement experience.three available models offer resolution capabilities up to 12 digits/sec single shot frequency resolution on a one second gate. Single shot time interval measurements can be resolved down to 20 psec. More insight to see the measurements, graphs and math you need with large 4.3 (109.22 mm) color graphical display. Digits Graph views of trendline/strip charts, histograms with markers to zoom in to the data you need Markers are available to read to read specific measurement values from trend and histogram charts. Colored limit lines allow you to set up your pass/fail boundaries and easily determine from the front panel when measurements have surpassed those thresholds. Math with built in statistics and analysis New data logging capability automatically saves acquisition results to non-volatile memory (75 MB, up to 5 M readings) at up to 75,000 readings/sec. Transfer readings from memory via LAN or USB as fast as 1M readings in 2 s. Easy access to your basic measurement functions: Freq/Period (all models): frequency, frequency ratio, period, single period, pulse/burst measurements (53230A) Time Interval (53220A / 53230A): time interval, rise/fall, duty, pulse width, phase Totalize (53220A / 53230A) Voltage Levels (all models) Optional Pulse Microwave measurements (53230A): burst carrier frequency, pulse repetition frequency (PRF), pulse repetition interval (PRI), burst width Continuous gap-free measurements (53230A): Enable basic modulation domain analysis. Choose the number of samples (up to 1M samples) or time (up to 100,000 seconds), and collect a block of gap free measurements with pairs of delta-time timestamps for every defined number of events (for that trigger/gate). The capability is available on all channels, one channel at a time. Built-in help allows you to quickly get guidance on the functions you need Advanced triggering capabilities for gate start and stop hold off and delay based on time or events USB Memory Port to supplement 1M reading internal memory 4

General characteristics Warm-up time Display User interface and help languages Bench dimensions Rack mount dimensions All models 45 minutes 4.3" (109.22 mm) color TFT WQVGA (480 x 272), LED backlight English, German, French, Japanese, Simplified Chinese, Korean 261.1 mm W x 103.8 mm H x 303.2 mm D 212.8 mm W x 88.3 mm H x 272. 3 mm D (2U x ½ width) Weight 3.9 kg (8.6 lbs) fully optioned; 3.1 kg (6.9 lbs) without Option 300 (battery option) Operating temperature 0 ºC to +55 ºC Power 100V - 240V ± 10%, 50-60 Hz ± 5%; 100 V - 120 V, 400 Hz ± 10% Interfaces LXI-C 1.3 (LAN sockets and VXI-11 protocol); USB 2.0 device port (USB-TMC488 protocol); GPIB Battery technology (Option 300) Internal lithium ion battery with integrated smart battery monitor and charger Accessories included Documentation CD including user s guide, SCPI/programmers reference, programming examples, IO library instructions Power line cord, 2 m USB2.0 Certificate of calibration and 1-year standard warranty Easy compatibility with Agilent 53131A, 53132A, 53181A (531xxA) frequency counters Select 531xxA family compatibility mode for full SCPI compatibility with Agilent s previous generation of counters. GPIB connectivity allows for full use of your existing Agilent 531xxA counter programs. Standard TCXO timebase in every model, option to upgrade to an ultra-high stability OCXO timebase for even more accuracy, or lock to your own external timebase reference. Optional battery for continuous timebase temperature maintenance High-speed USB 2.0 connectivity GPIB for system compatibility with 531xxA counters. 88.3 212.8 272.3 103.8 261.2 302.2 Optional rear terminal inputs LXI-C/LAN Ethernet connectivity for remote access 5

Abbreviated Characteristics and Specifications* 53210A 350 MHz, 10-digit/s RF counter 53220A 350 MHz, 12 digit/s, 100 ps universal frequency counter / timer 53230A 350 MHz, 12-digit/s, 20 ps universal frequency counter / timer Inputs Standard channels (Option 201 adds parallel rear panel inputs) Ch 1: DC 350 MHz Ch 1 and Ch 2: DC 350 MHz Impedance, coupling Selectable 1 M Ω ± 1.5% or 50 Ω ± 1.5% <25 pf; Selectable DC or AC coupling Amplitude input range ±5 V (±50 V) full scale ranges; ±500 V range available with 10:1 probe on counter input Input event threshold level ±5 V (±50 V) in 2.5 mv (25 mv) steps Sensitivity DC 100 MHz: 20 mvpk; > 100 MHz: 40 mvpk Optional microwave channel front type N Opt Ch 2 Opt Ch 3 (Option 203 moves the input connector to a rear panel SMA(f)) Frequency range Opt 106: 100 MHz 6 GHz or Opt 115: 300 MHz 15 GHz Amplitude range Opt 106: autoranged to +19 dbm max (2 Vrms) Opt 115: autoranged to +13 dbm max. (1.0 Vrms) Sensitivity 6 GHz (Opt 106): -27 dbm (10 mvrms); 15 GHz (Opt 115): 0.3 GHz 2 GHz: -23 dbm / 2 GHz 13 GHz: -26 dbm / 13 GHz 15 GHz: -21 dbm Measurement range Frequency resolution 10 digits/sec 12 digits/sec Time Interval resolution NA 100 psec 20 psec Measurements Frequency, period, frequency ratio, max/min/peak-to-peak input voltage Pulse/burst microwave measurements Option 150 Frequency, period, frequency ratio, max/min/peak-to-peak input voltage, time interval, single period, pulse width, rise/fall time, duty cycle, phase, totalize Frequency, period, frequency ratio, max/min/peak-to-peak input voltage, time interval, single period, pulse width, rise/fall time, duty cycle, phase, totalize, timestamp/mda NA NA Carrier frequency, carrier period, pulse repetition interval (PRI), pulse repetition frequency (PRF), positive and negative width Gate characteristics Source Time, external Time, external, advanced (gate start, stop/hold-off time or events) Gate time (step size) 1 ms 1000 s (10 µs) 100 µs 1000 s (10 µs) 1 µs 1000 s (1 µs) Advanced: Gate start and stop hold-off NA Source: internal/external/unused standard input channel Slope: positive/negative; delay and hold-off by time or events (edges) Trigger characteristics Source Internal, external, bus, manual Trigger count and samples/trigger 1 to 1,000,000 Trigger delay 0 s to 3600 s in 1 µs steps Math, memory, speed Speed characteristics (Note: Refer to pub #5990-6283EN for details Math Statistics Graphical display Memory * Please refer to Datasheet pub #5990-6283EN for details on specification, characteristic and typical value definitions. Single measurement throughput: Up to 400 readings/sec Block Reading throughput: Up to 66,500 readings/sec Maximum measurements to internal memory: 75,000 readings/sec frequency; 90,000 readings/sec time interval Smoothing (reading moving average), scaling, -change, null Mean, standard deviation, max, min, Mean, standard deviation, max, min, peak-to-peak, count, Allan Deviation peak-to-peak, count Digits, trend, histogram, limit test, markers Volatile reading memory: 1M readings (16 MB); data log (automatically saves acquisition results to memory) save and recall user-definable instrument set-ups; USB file system 6

Abbreviated Characteristics and Specifications, continued Standard TCXO Ultra-high stability OCXO Option 010 Aging 24-hour ± 0.3 ppb (typ) 30-day ± 0.2 ppm (typ) ± 10 ppb 1-year ± 1 ppm ± 50 ppb Temperature 0 ºC to 55 ºC relative to 25 ºC ± 1 ppm ± 5 ppb Timebase characteristics Timebase reference Internal, external, auto External timebase input Impedance 1k Ω, AC coupled Level 100 mvrms to 2.5 Vrms Lock frequencies and range 10 MHz, 5 MHz, 1 MHz ±1 ppm (±0.1 ppm for Option 010 U-OCXO timebase) Timebase output Signal 10 MHz sinewave Impedance 50 Ω ± 5% at 10 MHz Level 0.5 Vrms into a 50 Ω load 1.0 Vrms into a 1 k Ω load Accuracy Example ± [(k * Random Uncertainty) + Systematic Uncertainty + Timebase Uncertainty] See extended specifications document 5990-6283EN for complete expression of measurement uncertainty Example 1-year basic accuracy with Opt 010 ultra-high stability OCXO timebase: For a 1 MHz, 2 Vpp squarewave input using a 1 sec gate time. Accuracy Time base error = ± 15 ppb Ordering Information Model numbers 53210A 350 MHz, 10-digit/s RF frequency counter 53220A 350 MHz, 12 digit/s, 100 ps universal frequency counter/time 53230A 350 MHz, 12-digit/s, 20 ps universal frequency counter/timer Available options Option 010 Ultra-high-stability OCXO timebase Option 106 6 GHz microwave input Option 115 15 GHz microwave input Option 150 Pulse microwave measurements (53230A only) Option 201 Add rear panel parallel inputs for baseband channels Option 203 Optional microwave input rear panel SMA(f) connector Option 300 Add internal lithium ion smart battery and charger Recommended accessories 34190A Rack mount kit 34194A Dual-lock link kit 34191A 2U dual flange kit 34131A Transit case 1250-1476 BNC(f) to Type-N adapter N2870A Passive probe, 1:1, 35 MHz, 1.3 m N2873A Passive probe, 10:1, 500 MHz, 1.3 m N2874A Passive probe, 10:1, 1.5 GHz, 1.3 m For detailed specifications, see the Agilent 53200 RF and Universal Frequency Counter/Timers data sheet: http://cp.literature.agilent.com/litweb/pdf/5990-6283en.pdf 7

www.agilent.com FOR MORE INFORMATION www.agilent.com/find/ FrequencyCounters www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. We share measurement and service expertise to help you create the products that change our world. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair, reduce your cost of ownership, and move us ahead of your development curve. www.agilent.com/find/advantageservices Agilent Electronic Measurement Group KEMA Certified ISO 9001:2008 Quality Management System www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3500 Latin America 305 269 7500 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: June 15, 2010 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2011 Printed in USA, April 21, 2011 5990-6339EN