EN : 2015 IEC :2014 TEST REPORT FOR LED ILLUMINATOR MODEL NUMBER: P1347 REPORT NUMBER: E1V1 ISSUE DATE: MAY 15, 2017

Similar documents
FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd.

FCC Part 15 Subpart B Test Report. FCC PART 15 Subpart B Class B: 2014

Sensoray. Model 819. Tests Conducted by: ElectroMagnetic Investigations, LLC. May 10, 2013

Test Report #: Date: January 24, 2006

Page: 1 of 19 EMC TEST REPORT EN55024:1998+A2:2003

Test Report. Product Name: Access Point Model No.: MS-6809 FCC ID: DoC

CENTRE OF TESTING SERVICE INTERNATIONAL

FCC PART MEASUREMENT AND TEST REPORT FOR. DongGuan City FLYSKY Remote Model Co., Ltd.

FCC ID: IMK-ILCISA EMI TEST REPORT

TABLE OF CONTENTS 1. GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY

FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS

Date: ESPOO Page: 1 (10) Appendices. Tyre Pressure Monitoring Device. Flextronics International Finland.

TEST REPORT. iphone Hi-Fi Audio cable Adapter with Lightning female connector Model No.:

FCC PART 15B, CLASS B TEST REPORT. Autel Intelligent Tech. Corp., Ltd.

EMC Test Report. 850 Kacena Road Hiawatha, IA 52233

FCC TEST REPORT For. ETI Solid State Lighting (Zhuhai) Ltd. LED downlight Model No.: XX

FCC Part 15B Test Report

Sunlight Supply, Inc.

Test Report. Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 )

FCC PART TEST REPORT. HHC Changzhou Corp.

CONTENTS 6.2 TEST SET-UP...16

Report On. FCC Testing of the Pace Plc 16x4 Hybrid Gateway Cable Set Top Box COMMERCIAL-IN-CONFIDENCE

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC FCC ID TEST REPORT

FCC Report. Beijing Visual World Technology Co.,Ltd.

Testing. Maker Works. Applicant: Model No.: FCC ID: Jun., May to 16. Date of Test: PASS* Test Result: Signature: Authorized. this report.

R&TTE EMC TEST REPORT

FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT

T E S T - R E P O R T. No for. SLG 42 MOBY Component

Report No. 074L076-RFCEP02V01-A. Test Report MSI / MS-6837D

Report No R-RFCEP02V01. Test Report. MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

CONTENTS 1. GENERAL INFORMATION INTRODUCTION PRODUCT INFORMATION DESCRIPTION OF TESTS CHANNEL BANDWIDTH...

Order Number : GETEC-C FCC Part 15 subpart B Test Report Number : GETEC-E Page 2 / 32 CONTENTS

Report No R-RFCEP02V01. Test Report MSI / MS-6837D. Date of Receipt Aug. 21, Issued Date Sep. 11, 2007

Report No. 074L146-RFCEP02V01. Test Report MSI / MS-6837D. Date of Receipt Apr. 24, Issued Date May. 28, 2007

FCC Report (WIFI) Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town Business Park LiShan Road, NanShan, Shenzhen, Guangdong, China

FCC test report. Via Pezza Alta, 13 I Rustignè di Oderzo (TV)

Page: 1 of 15 FCC TEST REPORT. : MEGAVIEW DIGITECH LIMITED : C Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

APPLICATION OF CERTIFICATION For. TTE Technology Inc. LCD TV FCC ID: W8ULE32HDE3000

FCC Report (WIFI) Shenzhen SDMC Technology Co., Ltd 2AFC2-STB-1HD. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT Q6WBT * In the configuration tested, the EUT complied with the standards specified above.

CHAO WEI ELECTRONICS CO., LTD. FCC REPORT CHAO WEI ELECTRONICS CO., LTD.

EMC REPORT. Shenzhen Sunchip Technology Co., Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC Report (WIFI) Red Bear Company Limited. RedBear IoT phat 2ABXJ-PHAT-IOT

FCC Test Report. Color LCD Monitor

TEST REPORT. Power Spout PLT V. tested to. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

EMC Test Report. Client: Crestron Electronics, Inc. Tested by: Jeremy O. Pickens, Senior EMC Engineer

ONETECH Testing & Eval. Lab. VERIFICATION FCC RULES PARTS 2 & 15 CLASS A DIGITAL DEVICE. for AUTHORIZED. Win4NET Co., Ltd.

STC (Dongguan) Company Limited EC VERIFICATION OF COMPLIANCE EMC-D163584VOC

FCC PART TEST REPORT SHANGHAI MERIT TECHNOLOGY CORP.

A Test Lab Techno Corp. FCC. RF Test Report. Product Type. : Mobile Hotspot. Applicant. : Netgear Inc.

EMC Test Report. Client: Continental Automotive Systems, Inc. Tested by: Fendy Liauw, Engineering Technician

FCC Test Report (Class II Permissive Change)

FCC TEST REPORT D-LINK CORPORATION

ELECTRICAL TESTING FOR:

EMC TEST REPORT. Product : Digital Camcorder Model No. : SCD5000. SAMSUNG ELECTRONICS Co., Ltd. EMC Test Laboratory. Project No.

CERTIFICATION APPLICATION TEST REPORT

FCC Part 15 Certification Test Report. 433 MHz Alarm System

Test result 1. Conducted emission EN 55022: A1:2007 EA 3 passed 2. Radiated emission <1GHz (others)

T E S T - R E P O R T. No for PC24E-11-FC/R. RF-modem for wireless LAN. Agere Systems Nederland B.V.

FCC PART 22H, PART 24E MEASUREMENT AND TEST REPORT. Shanghai AirM2M Communication Technology Co., Ltd

TEST REPORT. Test Report No. : UL-RPT-RP C V2.0. Date of Issue: 06 March 2018

TEST REPORT FROM RFI GLOBAL SERVICES LTD

e2b calibration 521 Fifth Avenue Chardon, Ohio Phone: Fax: Certificate Of Calibration

Specifications. Reference Documentation. Performance Conditions

Report No. 103S085E-RFCEP02V01-A. Test Report

TEST REPORT. Test Report No. : UL-RPT-RP JD18L V2.0. Manufacturer : Neeo AG. Model No. : 6336-BRAIN FCC ID : 2AKK7-BR633601

Noise Detector ND-1 Operating Manual

Improving the accuracy of EMI emissions testing. James Young Rohde & Schwarz

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

TEST REPORT FROM RFI GLOBAL SERVICES LTD

3500/42E Vibration Monitor

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS-6967 FCC ID. : I4L-MS6967

Fibre Optic Modem ODW-622

LONWORKS Fibre Optic Converter

Raspberry Pi (Trading) Ltd. Raspberry Pi. dated. 9th December 2013

FCC Test Report (Class II Permissive Change)

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of NYNE MULTIMEDIA INC. Bluetooth Speaker. Model Number: NYNE VIBE FCC ID: AWA-NYNEVIBE

ODW-621. RS-232 Point-to-point applications

Fibre Optic Modem ODW-611

FCC REPORT. Report Reference No... : TRE R/C.: Simbans Picasso 10 Inch Tablet

LONWORKS Fibre Optic Router

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Agilent 87405C 100 MHz to 18 GHz Preamplifier

JD725A Cable and Antenna Analyzer - Dual Port

Fibre optic router for TP/FT-10 LRW-112PP

MAP110 AC-DC Series Data Sheet

ATT AN TENG TESTING R& TTE TEST REPORT. For Electric Skateboard Surfwheel. Test Report Number: ATT RT

PAM-1840 Preamplifier Operation Manual

R&S RT-Zxx High-Bandwidth Probes Specifications

TEST REPORT. Report Number: MPK-003B Project Number: G October 20, 2017

Indoor Linear 80W Driver SI-C215280N2KR

Multifunction Digital Timer

REPORT Datum/Date Beteckning/Reference Sida/Page

CERTIFICATION APPLICATION TEST REPORT

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Transcription:

EN 60601-1-2: 2015 IEC 60601-1-2:2014 TEST REPORT FOR LED ILLUMINATOR MODEL NUMBER: P1347 REPORT NUMBER: 11473017- E1V1 ISSUE DATE: MAY 15, 2017 Prepared for TECHNI-QUIP CORPORATION 530 BOULDER COURT SUITE 103 PLEASANTON CALIFORNIA 94566 USA Prepared by 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888

Revision History Rev. Issue Date Revisions Revised By V1 5/15/2017 Initial Issue --- Page 2 of 97

TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS... 4 2. TEST METHODOLOGY... 6 3. FACILITIES AND ACCREDITATION... 7 4. CALIBRATION AND UNCERTAINTY... 8 4.1. MEASURING INSTRUMENT CALIBRATION... 8 4.2. SAMPLE CALCULATION... 8 4.3. MEASUREMENT UNCERTAINTY... 8 5. EQUIPMENT UNDER TEST... 9 5.1. DESCRIPTION OF EUT... 9 5.2. TEST CONFIGURATIONS... 9 5.3. MODE(S) OF OPERATION... 9 5.4. SOFTWARE AND FIRMWARE... 10 5.5. MODIFICATIONS... 10 5.6. DETAILS OF TESTED SYSTEM... 10 6. EN 60601-1-2 EMISSIONS REQUIREMENTS... 13 6.1. RADIATED EMISSIONS... 13 6.2. AC MAINS LINE CONDUCTED EMISSIONS... 18 6.3. AC MAINS HARMONIC CURRENT EMISSIONS... 39 6.4. AC MAINS VOLTAGE FLUCTUATIONS AND FLICKER... 44 7. EN 60601-1-2 IMMUNITY REQUIREMENTS... 47 7.1. PERFORMANCE CRITERIA... 47 7.2. ELECTROSTATIC DISCHARGE... 49 7.3. RADIO FREQUENCY ELECTROMAGNETIC FIELD IMMUNITY... 65 7.4. FAST TRANSIENTS, COMMON MODE IMMUNITY... 67 7.5. SURGES... 69 7.6. RADIO FREQUENCY, COMMON MODE IMMUNITY... 71 7.7. MAGNETIC FIELD IMMUNITY... 73 7.8. AC MAINS VOLTAGE DIPS AND INTERRUPTIONS... 75 7.9. VARIATIONS OF POWER FREQUENCY... 77 8. SETUP PHOTOS... 79 8.1. EMISSIONS... 79 8.2. IMMUNITY... 84 9. APPENDIX A (IEC 60601-1-2, Compliance Summary)... 93 Page 3 of 97

1. ATTESTATION OF TEST RESULTS COMPANY NAME: EUT DESCRIPTION: MODEL: SERIAL NUMBER: TECHNIQUIP CORPORATION LED ILLUMINATION P1347 UNIT #3 for POLE-MOUNT and #6 For TABLE TOP DATE TESTED: JANUARY 24, 2017 To FEBRUARY 6, 2017 APPLICABLE STANDARDS STANDARD EN 60601-1-2: 2015 IEC 60601-1-2: 2014 TEST RESULTS Pass Pass UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Page 4 of 97

Reviewed By: Prepared By: Huda Mustapha HUDA MUSTAPHA PROJECT LEAD UL Verification Services Inc. THANH NGUYEN LABORATORY ENGINEER UL Verification Services Inc. Approved and released for UL Verification Services Inc. by: EDGARD RINCAND PROJECT LEAD UL Verification Services Inc. Page 5 of 97

2. TEST METHODOLOGY All tests were performed in accordance with the procedures documented in the most recent versions of basic standards as referenced by IEC 60601-1-2:2014 and EN 60601-1-2:2015. Specific respective tests were performed in accordance with basic standard versions as follows: BASIC STANDARD VERSION SUBJECT EN 55011 2009 A1 2010 CISPR 11 2009 Emissions A1 2010 EN 61000-3-2 2014 IEC 61000-3-2 2014 Harmonic Current EN 61000-3-3 2013 IEC 61000-3-3 2013 Flicker EN 61000-4-2 2009 ESD IEC 61000-4-2 EN 61000-4-3 A1 A2 IEC 61000-4-3 A1 A2 EN 61000-4-4 IEC 61000-4-4 EN 61000-4-5 IEC 61000-4-5 EN 61000-4-6 IEC 61000-4-6 EN 61000-4-8 IEC 61000-4-8 EN 61000-4-11 IEC 61000-4-11 2008 2006 2008 2010 2006 2007 2010 2012 2012 2014 2014 2014 2013 2010 2009 2004 2004 Radiated Immunity EFT Surge Conducted Immunity Magnetic Voltage Dips and Interrupts Page 6 of 97

3. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 47173 and 47266 Benicia Street, Fremont, California, USA. Line conducted emissions are measured only at the 47173 address. The following table identifies which facilities were utilized for radiated emission measurements documented in this report. Specific facilities are also identified in the test results sections. 47173 Benicia Street 47266 Benicia Street Chamber A Chamber D Chamber B Chamber E Chamber C Chamber F Chamber G Chamber H The above test sites and facilities are covered under FCC Test Firm Registration # 208313. Chambers A through H are covered under Industry Canada company address code 2324B with site numbers 2324B -1 through 2324B-8, respectively. UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. Page 7 of 97

4. CALIBRATION AND UNCERTAINTY 4.1. MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated in accordance with the manufacturer's recommendations, and is traceable to recognized national standards. 4.2. SAMPLE CALCULATION Where relevant, the following sample calculation is provided: Field Strength (dbuv/m) = Measured Voltage (dbuv) + Antenna Factor (db/m) + Cable Loss (db) Preamp Gain (db) 36.5 dbuv + 18.7 db/m + 0.6 db 26.9 db = 28.9 dbuv/m 4.3. MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus: PARAMETER Conducted Disturbance, 0.15 to 30 MHz Radiated Disturbance, 30 to 1000 MHz UNCERTAINTY 3.65 db 5.36 db Uncertainty figures are valid to a confidence level of 95%. Page 8 of 97

5. EQUIPMENT UNDER TEST 5.1. DESCRIPTION OF EUT The EUT is a high output LED illuminator designed for scientific and medical applications. It has two models: Table Top and Pole-Mount. GENERAL INFORMATION Power Requirements List of frequencies generated or used by the EUT 100-240 VAC, 50/60Hz <108 MHz 5.2. TEST CONFIGURATIONS The following configurations were investigated: EUT Configuration Table Top Pole-Mount Description EUT standalone and plugged to AC mains EUT plugged to AC mains, and 12 Vdc port connected to variable resistive load Radiated emissions, line conducted emissions, ESD and radiated immunity testing was performed on both configurations shown above. All other tests were performed only on the pole-mount unit as worst case. The RS232 port was not populated based on the customer s declaration that it is intended for service/management. For radiated emissions, the pole mount unit was invesitaged in three orthogonal oreintations, X, Y and Z, and position Y was found to be worst case. Refer to set-up photos in section 8.1 below. 5.3. MODE(S) OF OPERATION Mode Normal Description Powered On, LED output set to maximum and resistive load set to 24 ohms (only for pole-mount unit) Page 9 of 97

5.4. SOFTWARE AND FIRMWARE The firmware used during tesing was FW01_2016-07-07. 5.5. MODIFICATIONS For both models, to pass radiated and line conducted emissions, ferrite bead KGS part # GRFC- 10 was added to the power cord at USA 115VAC plug during testing. 5.6. DETAILS OF TESTED SYSTEM SUPPORT EQUIPMENT & PERIPHERALS SUPPORT EQUIPMENT & PERIPHERALS LIST Description Manufacturer Model Serial Number Variable Resistive Load BSQ 30 ohms/300w N/A Multimeter Fluke 115 True RMS 33231872WS I/O CABLES I/O CABLE LIST Cable Port # of Connector Cable Cable Remarks No. Identical Type Type Length Ports m 1 AC 1 3 Prong Unshielded 1.8 2 DC 1 Barrel AWS 26 2 3 DC 1 Banana Jack AWS 26 1 Hostpial grade IEC cable with ferrite added TEST SETUP The EUT was installed in a typical configuration. Refer to the following diagrams. Page 10 of 97

TEST SETUP DIAGRAMS Table Top Page 11 of 97

Pole-Mount Page 12 of 97

6. EN 60601-1-2 EMISSIONS REQUIREMENTS LIMIT 6.1. RADIATED EMISSIONS EN/IEC 60601-1-2 CISPR 11 GROUP 1 CLASS B 10 m measuring distance 3 m measuring distance a Frequency range Quasi-peak Quasi-peak MHz db(µv/m) db(µv/m) 30 to 230 30 40 230 to 1000 37 47 On a test site, class B equipment can be measured at a nominal distance of 3 m or 10 m. A measuring distance less than 10 m is allowed only for equipment which complies with the definition given in 3.10. At the transition frequency, the more stringent limit shall apply. a The limits specified for the 3 m separation distance apply only to small equipment meeting the size criterion defined in 3.10. TEST PROCEDURE CISPR 11 EN/IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due Antenna Sunol Sciences Corp. JB3 408 11/10/2016 11/10/2017 Broadband Hybrid 30-2000 MHz Amplifier 30-1000 HP 8447D 115 8/26/2016 8/26/2017 MHz PXA Agilent N9030A 905 1/1/2017 1/11/2018 Radiated Software UL UL EMC Ver 9.5, April 26, 2015 Page 13 of 97

RESULTS: Table Top RADIATED EMISSIONS 30 TO 1000 MHz (WORST-CASE CONFIGURATION) HORIZONTAL AND VERTICAL PLOTS Page 14 of 97

Trace Markers Marker Frequency (MHz) Meter Reading (dbuv) Det AF T408 (db/m) Amp/Cbl (db) Corrected Reading (dbuv/m) ClassB Grp1 QPk Limit (dbuv/m) 1 30.1434 21.76 Qp 25.3-27.3 19.76 40-20.24 66 137 H 3 30.4675 36.01 Pk 25-27.2 33.81 40-6.19 0-360 100 V 4 84.5275 49.24 Pk 11.3-26.5 34.04 40-5.96 0-360 100 V 5 93.8775 47.43 Pk 12.5-26.4 33.53 40-6.47 0-360 100 V 6 110.8674 46 Qp 16.7-26.1 36.6 40-3.4 114 102 V 2 112.5275 40.68 Qp 16.9-26.1 31.48 40-8.52 260 259 H 7 144.9386 39.79 Qp 16.8-25.7 30.89 40-9.11 77 104 V Margin (db) Azimuth (Degs) Height (cm) Polarity Pk - Peak detector Qp - Quasi-Peak detector Page 15 of 97

Pole-Mount RADIATED EMISSIONS 30 TO 1000 MHz (WORST-CASE CONFIGURATION) HORIZONTAL AND VERTICAL PLOTS Page 16 of 97

Trace Markers Marker Frequency (MHz) Meter Reading (dbuv) Det AF T408 (db/m) Amp/Cbl (db) Corrected Reading (dbuv/m) ClassB Grp1 QPk Limit (dbuv/m) 1 30.0173 21.04 Qp 25.4-27.3 19.14 40-20.86 59 289 H 4 56.6115 39.82 Qp 11.2-26.9 24.12 40-15.88 17 100 V 7 60.9278 49.26 Qp 11.6-26.8 34.06 40-5.94 28 100 V 5 88.4083 52.72 Qp 11.4-26.4 37.72 40-2.28 214 100 V 2 88.4124 51.68 Qp 11.4-26.4 36.68 40-3.32 149 383 H 9 152.1672 38.47 Qp 16.5-25.6 29.37 40-10.63 336 101 V 3 160.7719 42.43 Qp 16.3-25.5 33.23 40-6.77 62 220 H 6 160.2841 42.73 Qp 16.3-25.5 33.53 40-6.47 170 109 V 8 267.8 46.83 Pk 16.9-24.4 39.33 47-7.67 0-360 100 H Margin (db) Azimuth (Degs) Height (cm) Polarity Pk - Peak detector Qp - Quasi-Peak detector Page 17 of 97

LIMIT 6.2. AC MAINS LINE CONDUCTED EMISSIONS EN/IEC 60601-1-2 CISPR 11 GROUP 1 CLASS B Frequency range MHz Quasi-peak db(µv) Average db(µv) 66 56 0.15 to 0.50 Decreasing linearly with Decreasing linearly with logarithm of frequency to logarithm of frequency to 56 46 0.50 to 5 56 46 5 to 30 60 50 At the transition frequency, the more stringent limit shall apply. TEST PROCEDURE CISPR 11 EN/IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local Cal Date Cal Due ID (T No.) EMI Test Receiver, Rohde & Schwarz ESR 1436 1/06/2017 1/06/2018 9KHz to 7GHz LISN FCC 50/250-25-2 24 02/09/2016 02/09/2017 LISN FCC 50/250-25-2-01- 1310 06/08/2016 06/08/2017 CISPR16 Transient Limiter Com-Power LIT-930 1457 02/10/2016 02/10/2017 Thermometer Scientific Fisher 14-650-118 1576 2/19/2016 2/19/2017 Page 18 of 97

Table Top RESULTS 100 V, 60 Hz WORST CONDUCTED EMISSIONS 100 V, 60 Hz Ambient Temperature: 24ºС Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.168 30.07 Qp 0 0 10.1 40.17 65.06-24.89 - - 2.168 29.51 Ca 0 0 10.1 39.61 - - 55.06-15.45 3.25125 30.39 Qp 0.1 10.1 40.59 61.72-21.13 - - 4.25125 30.07 Ca 0.1 10.1 40.27 - - 51.72-11.45 5.5325 25.58 Qp 0.1 10.1 35.78 56-20.22 - - 6.5325 18.44 Ca 0.1 10.1 28.64 - - 46-17.36 7.6675 27.02 Qp 0.1 10.1 37.22 56-18.78 - - 8.6675 22.35 Ca 0.1 10.1 32.55 - - 46-13.45 9.8025 24.35 Qp 0.1 10.1 34.55 56-21.45 - - 10.8025 17.36 Ca 0.1 10.1 27.56 - - 46-18.44 11.9375 25.41 Qp 0.1 10.1 35.61 56-20.39 - - 12.9375 20.14 Ca 0.1 10.1 30.34 - - 46-15.66 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.168 31.25 Qp 0 0 10.1 41.35 65.06-23.71 - - 14.168 30.71 Ca 0 0 10.1 40.81 - - 55.06-14.25 15.25125 30.68 Qp 0.1 10.1 40.88 61.72-20.84 - - 16.25125 30.36 Ca 0.1 10.1 40.56 - - 51.72-11.16 17.53475 25.36 Qp 0.1 10.1 35.56 56-20.44 - - 18.53475 17.85 Ca 0.1 10.1 28.05 - - 46-17.95 19.66975 26.65 Qp 0.1 10.1 36.85 56-19.15 - - 20.66975 21.48 Ca 0.1 10.1 31.68 - - 46-14.32 21.8025 24.99 Qp 0.1 10.1 35.19 56-20.81 - - 22.8025 17.32 Ca 0.1 10.1 27.52 - - 46-18.48 23.93975 25.45 Qp 0.1 10.1 35.65 56-20.35 - - 24.93975 18.61 Ca 0.1 10.1 28.81 - - 46-17.19 Qp - Quasi-Peak detector Ca - CISPR average detection Margin (db) Page 19 of 97

LINE 1 AND LINE 2 RESULTS 100 V, 60 Hz Page 20 of 97

RESULTS 110 V, 60 Hz WORST CONDUCTED EMISSIONS 110 V, 60 Hz Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.15225 39.66 Qp.1.1 10.1 49.96 65.88-15.92 - - 2.15225 21.01 Ca.1.1 10.1 31.31 - - 55.88-24.57 3.25125 29.65 Qp 0.1 10.1 39.85 61.72-21.87 - - 4.25125 29.03 Ca 0.1 10.1 39.23 - - 51.72-12.49 5.33675 27.04 Qp 0.1 10.1 37.24 59.28-22.04 - - 6.33675 23.55 Ca 0.1 10.1 33.75 - - 49.28-15.53 7.672 27.59 Qp 0.1 10.1 37.79 56-18.21 - - 8.672 22.34 Ca 0.1 10.1 32.54 - - 46-13.46 9.84075 25.58 Qp 0.1 10.1 35.78 56-20.22 - - 10.84075 12.88 Ca 0.1 10.1 23.08 - - 46-22.92 11.93975 25.45 Qp 0.1 10.1 35.65 56-20.35 - - 12.93975 20.12 Ca 0.1 10.1 30.32 - - 46-15.68 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.15225 37.14 Qp 0 0 10.1 47.24 65.88-18.64 - - 14.15225 19.55 Ca 0 0 10.1 29.65 - - 55.88-26.23 15.249 29.15 Qp 0.1 10.1 39.35 61.79-22.44 - - 16.249 28.39 Ca 0.1 10.1 38.59 - - 51.79-13.2 17.33675 24.81 Qp 0.1 10.1 35.01 59.28-24.27 - - 18.33675 23.83 Ca 0.1 10.1 34.03 - - 49.28-15.25 19.66975 26.23 Qp 0.1 10.1 36.43 56-19.57 - - 20.66975 19.42 Ca 0.1 10.1 29.62 - - 46-16.38 21.93975 26.05 Qp 0.1 10.1 36.25 56-19.75 - - 22.93975 21.03 Ca 0.1 10.1 31.23 - - 46-14.77 23 1.2075 25.54 Qp 0.1 10.1 35.74 56-20.26 - - 24 1.2075 17.69 Ca 0.1 10.1 27.89 - - 46-18.11 Margin (db) Qp - Quasi-Peak detector Ca - CISPR average detection Page 21 of 97

LINE 1 AND LINE 2 RESULTS 110 V, 60 Hz Page 22 of 97

RESULTS 120 V, 60 Hz WORST CONDUCTED EMISSIONS 120 V, 60 Hz Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.15225 42.48 Qp.1.1 10.1 52.78 65.88-13.1 - - 2.15225 22.52 Ca.1.1 10.1 32.82 - - 55.88-23.06 3.3345 29.81 Qp 0.1 10.1 40.01 59.34-19.33 - - 4.3345 24.95 Ca 0.1 10.1 35.15 - - 49.34-14.19 5.93525 27.71 Qp 0.1 10.1 37.91 56-18.09 - - 6.93525 22.47 Ca 0.1 10.1 32.67 - - 46-13.33 7 1.203 25.84 Qp 0.1 10.1 36.04 56-19.96 - - 8 1.203 19.58 Ca 0.1 10.1 29.78 - - 46-16.22 9 10.28625 24.01 Qp 0.2 10.2 34.41 60-25.59 - - 10 10.28625 19.34 Ca 0.2 10.2 29.74 - - 50-20.26 11 23.75025 21.86 Qp.1.3 10.4 32.66 60-27.34 - - 12 23.75025 19.32 Ca.1.3 10.4 30.12 - - 50-19.88 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.15 40.95 Qp 0.1 10.1 51.15 66-14.85 - - 14.15 22 Ca 0.1 10.1 32.2 - - 56-23.8 15.25125 30.21 Qp 0.1 10.1 40.41 61.72-21.31 - - 16.25125 29.77 Ca 0.1 10.1 39.97 - - 51.72-11.75 17.53475 26.56 Qp 0.1 10.1 36.76 56-19.24 - - 18.53475 20.22 Ca 0.1 10.1 30.42 - - 46-15.58 19.93525 27.96 Qp 0.1 10.1 38.16 56-17.84 - - 20.93525 22.38 Ca 0.1 10.1 32.58 - - 46-13.42 21 5.21025 22.11 Qp 0.1 10.1 32.31 60-27.69 - - 22 5.21025 18.15 Ca 0.1 10.1 28.35 - - 50-21.65 23 23.75025 21.9 Qp.1.3 10.4 32.7 60-27.3 - - 24 23.75025 19.8 Ca.1.3 10.4 30.6 - - 50-19.4 Margin (db) Qp - Quasi-Peak detector Ca - CISPR average detection Page 23 of 97

LINE 1 AND LINE 2 RESULTS 120 V, 60 Hz Page 24 of 97

RESULTS 220 V, 60 Hz WORST CONDUCTED EMISSIONS 220 V, 60 Hz Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.15675 38.25 Qp 0.1 10.1 48.45 65.63-17.18 - - 2.168 29.03 Ca 0 0 10.1 39.13 - - 55.06-15.93 3.48975 33.43 Qp 0.1 10.1 43.63 56.17-12.54 - - 4.48975 16.94 Ca 0.1 10.1 27.14 - - 46.17-19.03 5.8925 32 Qp 0.1 10.1 42.2 56-13.8 - - 6.8925 15.01 Ca 0.1 10.1 25.21 - - 46-20.79 7.98025 31.47 Qp 0.1 10.1 41.67 56-14.33 - - 8.98025 14.75 Ca 0.1 10.1 24.95 - - 46-21.05 9 1.20525 28.14 Qp 0.1 10.1 38.34 56-17.66 - - 10 1.20525 18.12 Ca 0.1 10.1 28.32 - - 46-17.68 11 1.338 27.61 Qp 0.1 10.1 37.81 56-18.19 - - 12 1.338 14.99 Ca 0.1 10.1 25.19 - - 46-20.81 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.402 30.85 Qp 0.1 10.1 41.05 57.81-16.76 - - 14.402 17.37 Ca 0.1 10.1 27.57 - - 47.81-20.24 15.8025 31.31 Qp 0.1 10.1 41.51 56-14.49 - - 16.8025 16 Ca 0.1 10.1 26.2 - - 46-19.8 17.48975 32.25 Qp 0.1 10.1 42.45 56.17-13.72 - - 18.48975 14.75 Ca 0.1 10.1 24.95 - - 46.17-21.22 19.8025 31.31 Qp 0.1 10.1 41.51 56-14.49 - - 20.8025 16 Ca 0.1 10.1 26.2 - - 46-19.8 21.9375 31.68 Qp 0.1 10.1 41.88 56-14.12 - - 22.9375 20.93 Ca 0.1 10.1 31.13 - - 46-14.87 23 1.20525 28.58 Qp 0.1 10.1 38.78 56-17.22 - - 24 1.20525 17.87 Ca 0.1 10.1 28.07 - - 46-17.93 Margin (db) Page 25 of 97

LINE 1 AND LINE 2 RESULTS 220 V, 60 Hz Page 26 of 97

RESULTS 230 V, 50 Hz WORST CONDUCTED EMISSIONS 230 V, 50 Hz Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.40425 31.86 Qp 0.1 10.1 42.06 57.77-15.71 - - 2.402 21.3 Ca 0.1 10.1 31.5 - - 47.81-16.31 3.447 31.44 Qp 0.1 10.1 41.64 56.93-15.29 - - 4.44925 11.01 Ca 0.1 10.1 21.21 - - 46.89-25.68 5.537 33.24 Qp 0.1 10.1 43.44 56-12.56 - - 6.537 14.02 Ca 0.1 10.1 24.22 - - 46-21.78 7.80475 32.43 Qp 0.1 10.1 42.63 56-13.37 - - 8.80475 15.12 Ca 0.1 10.1 25.32 - - 46-20.68 9 10.068 23.81 Qp 0.2 10.2 34.21 60-25.79 - - 10 10.06575 20.34 Ca 0.2 10.2 30.74 - - 50-19.26 11 23.75025 21.68 Qp.1.3 10.4 32.48 60-27.52 - - 12 23.75025 19.34 Ca.1.3 10.4 30.14 - - 50-19.86 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.16575 33.53 Qp 0 0 10.1 43.63 65.17-21.54 - - 14.168 29.83 Ca 0 0 10.1 39.93 - - 55.06-15.13 15.402 28.39 Qp 0.1 10.1 38.59 57.81-19.22 - - 16.402 14.68 Ca 0.1 10.1 24.88 - - 47.81-22.93 17.447 29.31 Qp 0.1 10.1 39.51 56.93-17.42 - - 18.44925 9.05 Ca 0.1 10.1 19.25 - - 46.89-27.64 19.537 32.42 Qp 0.1 10.1 42.62 56-13.38 - - 20.537 13.56 Ca 0.1 10.1 23.76 - - 46-22.24 21.80475 32.51 Qp 0.1 10.1 42.71 56-13.29 - - 22.80475 15 Ca 0.1 10.1 25.2 - - 46-20.8 23 6.03825 22.23 Qp 0.2 10.2 32.63 60-27.37 - - 24 6.036 20.11 Ca 0.2 10.2 30.51 - - 50-19.49 Margin (db) Page 27 of 97

LINE 1 AND LINE 2 RESULTS 230 V, 50 Hz Page 28 of 97

Pole-Mount RESULTS 100 V, 60 Hz WORST CONDUCTED EMISSIONS 100 V, 60 Hz Ambient Temperature: 24ºС Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.15225 40.62 Qp.1.1 10.1 50.92 65.88-14.96 - - 2.15225 23.29 Ca.1.1 10.1 33.59 - - 55.88-22.29 3.39525 22.38 Qp 0.1 10.1 32.58 57.95-25.37 - - 4.39525 22.08 Ca 0.1 10.1 32.28 - - 47.95-15.67 5.66075 24.97 Qp 0.1 10.1 35.17 56-20.83 - - 6.66075 23.87 Ca 0.1 10.1 34.07 - - 46-11.93 7.92625 24.86 Qp 0.1 10.1 35.06 56-20.94 - - 8.92625 24.2 Ca 0.1 10.1 34.4 - - 46-11.6 9 1.1895 23.48 Qp 0.1 10.1 33.68 56-22.32 - - 10 1.1895 22.21 Ca 0.1 10.1 32.41 - - 46-13.59 11 10.7025 23.64 Qp 0.2 10.2 34.04 60-25.96 - - 12 10.7025 21.28 Ca 0.2 10.2 31.68 - - 50-18.32 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.15 39.64 Qp 0.1 10.1 49.84 66-16.16 - - 14.15 22.35 Ca 0.1 10.1 32.55 - - 56-23.45 15.39525 20.38 Qp 0.1 10.1 30.58 57.95-27.37 - - 16.39525 19.32 Ca 0.1 10.1 29.52 - - 47.95-18.43 17.66075 24.27 Qp 0.1 10.1 34.47 56-21.53 - - 18.66075 23.33 Ca 0.1 10.1 33.53 - - 46-12.47 19.92625 24.34 Qp 0.1 10.1 34.54 56-21.46 - - 20.92625 23.5 Ca 0.1 10.1 33.7 - - 46-12.3 21 1.18725 23.66 Qp 0.1 10.1 33.86 56-22.14 - - 22 1.18725 22.38 Ca 0.1 10.1 32.58 - - 46-13.42 23 10.69125 25.87 Qp 0.2 10.2 36.27 60-23.73 - - 24 10.69125 23.91 Ca 0.2 10.2 34.31 - - 50-15.69 Qp - Quasi-Peak detector Ca - CISPR average detection Margin (db) Page 29 of 97

LINE 1 AND LINE 2 RESULTS 100 V, 60 Hz Page 30 of 97

RESULTS 110 V, 60 Hz WORST CONDUCTED EMISSIONS 110 V, 60 Hz Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.15225 45.34 Qp.1.1 10.1 55.64 65.88-10.24 - - 2.15225 26.72 Ca.1.1 10.1 37.02 - - 55.88-18.86 3.393 21.68 Qp 0.1 10.1 31.88 58-26.12 - - 4.393 21.25 Ca 0.1 10.1 31.45 - - 48-16.55 5.65625 22.91 Qp 0.1 10.1 33.11 56-22.89 - - 6.65625 22.3 Ca 0.1 10.1 32.5 - - 46-13.5 7.92175 25.88 Qp 0.1 10.1 36.08 56-19.92 - - 8.92175 24.93 Ca 0.1 10.1 35.13 - - 46-10.87 9 1.18275 21.28 Qp 0.1 10.1 31.48 56-24.52 - - 10 1.18275 19.83 Ca 0.1 10.1 30.03 - - 46-15.97 11 10.932 25.23 Qp 0.2 10.2 35.63 60-24.37 - - 12 10.932 22.51 Ca 0.2 10.2 32.91 - - 50-17.09 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.15225 43.6 Qp 0 0 10.1 53.7 65.88-12.18 - - 14.15225 25.44 Ca 0 0 10.1 35.54 - - 55.88-20.34 15.6585 24.47 Qp 0.1 10.1 34.67 56-21.33 - - 16.6585 24.01 Ca 0.1 10.1 34.21 - - 46-11.79 17.92175 26.37 Qp 0.1 10.1 36.57 56-19.43 - - 18.92175 25.31 Ca 0.1 10.1 35.51 - - 46-10.49 19 1.185 24.35 Qp 0.1 10.1 34.55 56-21.45 - - 20 1.185 23.16 Ca 0.1 10.1 33.36 - - 46-12.64 21 1.4505 21.47 Qp 0.1 10.1 31.67 56-24.33 - - 22 1.4505 20.81 Ca 0.1 10.1 31.01 - - 46-14.99 23 10.932 27.8 Qp 0.2 10.2 38.2 60-21.8 - - 24 10.932 25.3 Ca 0.2 10.2 35.7 - - 50-14.3 Qp - Quasi-Peak detector Ca - CISPR average detection Margin (db) Page 31 of 97

LINE 1 AND LINE 2 RESULTS 110 V, 60 Hz Page 32 of 97

RESULTS 120 V, 60 Hz WORST CONDUCTED EMISSIONS 120 V, 60 Hz Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.15225 47.38 Qp.1.1 10.1 57.68 65.88-8.2 - - 2.15225 30.95 Ca.1.1 10.1 41.25 - - 55.88-14.63 3.19725 33.42 Qp 0.1 10.1 43.62 63.73-20.11 - - 4.19725 13.47 Ca 0.1 10.1 23.67 - - 53.73-30.06 5.39525 23.38 Qp 0.1 10.1 33.58 57.95-24.37 - - 6.39525 22.87 Ca 0.1 10.1 33.07 - - 47.95-14.88 7.6585 25.74 Qp 0.1 10.1 35.94 56-20.06 - - 8.6585 24.42 Ca 0.1 10.1 34.62 - - 46-11.38 9.9195 25.15 Qp 0.1 10.1 35.35 56-20.65 - - 10.9195 24.48 Ca 0.1 10.1 34.68 - - 46-11.32 11 1.185 23.44 Qp 0.1 10.1 33.64 56-22.36 - - 12 1.185 22.4 Ca 0.1 10.1 32.6 - - 46-13.4 13 11.706 25.14 Qp 0.2 10.2 35.54 60-24.46 - - 14 11.706 23.48 Ca 0.2 10.2 33.88 - - 50-16.12 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 15.15225 45.56 Qp 0 0 10.1 55.66 65.88-10.22 - - 16.15225 29.89 Ca 0 0 10.1 39.99 - - 55.88-15.89 17.19725 30.5 Qp 0.1 10.1 40.7 63.73-23.03 - - 18.19725 11.7 Ca 0.1 10.1 21.9 - - 53.73-31.83 19.6585 25.22 Qp 0.1 10.1 35.42 56-20.58 - - 20.6585 24 Ca 0.1 10.1 34.2 - - 46-11.8 21.92175 25.46 Qp 0.1 10.1 35.66 56-20.34 - - 22.92175 24.84 Ca 0.1 10.1 35.04 - - 46-10.96 23 1.18275 23.74 Qp 0.1 10.1 33.94 56-22.06 - - 24 1.18275 22.7 Ca 0.1 10.1 32.9 - - 46-13.1 25 11.17725 26.85 Qp 0.2 10.2 37.25 60-22.75 - - 26 11.17725 24.77 Ca 0.2 10.2 35.17 - - 50-14.83 Qp - Quasi-Peak detector Ca - CISPR average detection Margin (db) Page 33 of 97

LINE 1 AND LINE 2 RESULTS 120 V, 60 Hz Page 34 of 97

RESULTS 220 V, 60 Hz WORST CONDUCTED EMISSIONS 220 V, 60 Hz Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.168 33.75 Qp 0 0 10.1 43.85 65.06-21.21 - - 2.168 24.6 Ca 0 0 10.1 34.7 - - 55.06-20.36 3.19725 29.7 Qp 0.1 10.1 39.9 63.73-23.83 - - 4.19725 11.42 Ca 0.1 10.1 21.62 - - 53.73-32.11 5.65625 25.46 Qp 0.1 10.1 35.66 56-20.34 - - 6.65625 24.64 Ca 0.1 10.1 34.84 - - 46-11.16 7.92175 23.31 Qp 0.1 10.1 33.51 56-22.49 - - 8.92175 21.84 Ca 0.1 10.1 32.04 - - 46-13.96 9 1.18275 24.26 Qp 0.1 10.1 34.46 56-21.54 - - 10 1.18275 22.38 Ca 0.1 10.1 32.58 - - 46-13.42 11 12.201 25.75 Qp.1.2 10.2 36.25 60-23.75 - - 12 12.201 23.96 Ca.1.2 10.2 34.46 - - 50-15.54 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.17025 34.29 Qp 0.1 10.1 44.49 64.95-20.46 - - 14.17025 24.67 Ca 0.1 10.1 34.87 - - 54.95-20.08 15.19725 26.59 Qp 0.1 10.1 36.79 63.73-26.94 - - 16.19725 9.51 Ca 0.1 10.1 19.71 - - 53.73-34.02 17.65625 24.91 Qp 0.1 10.1 35.11 56-20.89 - - 18.65625 24.08 Ca 0.1 10.1 34.28 - - 46-11.72 19.9195 26.02 Qp 0.1 10.1 36.22 56-19.78 - - 20.9195 24.97 Ca 0.1 10.1 35.17 - - 46-10.83 21 1.1805 25.4 Qp 0.1 10.1 35.6 56-20.4 - - 22 1.1805 23.27 Ca 0.1 10.1 33.47 - - 46-12.53 23 11.6835 27.49 Qp 0.2 10.2 37.89 60-22.11 - - 24 11.6835 26.21 Ca 0.2 10.2 36.61 - - 50-13.39 Qp - Quasi-Peak detector Ca - CISPR average detection Margin (db) Page 35 of 97

LINE 1 AND LINE 2 RESULTS 220 V, 60 Hz Page 36 of 97

RESULTS 230 V, 50 Hz WORST CONDUCTED EMISSIONS 230 V, 50 Hz Range 1: Line-L1.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L1 LC Cables C1&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 1.15 36.04 Qp.1.1 10.1 46.34 66-19.66 - - 2.15 12.81 Ca.1.1 10.1 23.11 - - 56-32.89 3.393 23.92 Qp 0.1 10.1 34.12 58-23.88 - - 4.393 23.15 Ca 0.1 10.1 33.35 - - 48-14.65 5.6585 23.33 Qp 0.1 10.1 33.53 56-22.47 - - 6.6585 21.93 Ca 0.1 10.1 32.13 - - 46-13.87 7.9195 25.37 Qp 0.1 10.1 35.57 56-20.43 - - 8.9195 23.87 Ca 0.1 10.1 34.07 - - 46-11.93 9 1.185 19.28 Qp 0.1 10.1 29.48 56-26.52 - - 10 1.185 16.66 Ca 0.1 10.1 26.86 - - 46-19.14 11 11.148 26.63 Qp 0.2 10.2 37.03 60-22.97 - - 12 11.148 23.3 Ca 0.2 10.2 33.7 - - 50-16.3 Margin (db) Range 2: Line-L2.15-30MHz Marker Frequency (MHz) Meter Reading (dbuv) Det LISN L2 LC Cables C2&C3 Limiter (db) Corrected Reading dbuv CISPR 22 Class B QP Margin (db) CISPR 22 Class B Avg 13.168 30.72 Qp 0 0 10.1 40.82 65.06-24.24 - - 14.168 25 Ca 0 0 10.1 35.1 - - 55.06-19.96 15.65625 24.79 Qp 0.1 10.1 34.99 56-21.01 - - 16.65625 23.58 Ca 0.1 10.1 33.78 - - 46-12.22 17.9195 25.68 Qp 0.1 10.1 35.88 56-20.12 - - 18.9195 24.2 Ca 0.1 10.1 34.4 - - 46-11.6 19 1.1805 24.12 Qp 0.1 10.1 34.32 56-21.68 - - 20 1.1805 22.95 Ca 0.1 10.1 33.15 - - 46-12.85 21 1.44375 22.51 Qp 0.1 10.1 32.71 56-23.29 - - 22 1.44375 21.3 Ca 0.1 10.1 31.5 - - 46-14.5 23 11.15025 28.06 Qp 0.2 10.2 38.46 60-21.54 - - 24 11.15025 24.95 Ca 0.2 10.2 35.35 - - 50-14.65 Qp - Quasi-Peak detector Ca - CISPR average detection Margin (db) Page 37 of 97

LINE 1 AND LINE 2 RESULTS 230 V, 50 Hz Page 38 of 97

LIMIT 6.3. AC MAINS HARMONIC CURRENT EMISSIONS IEC 61000-3-2 TEST PROCEDURE IEC 61000-3-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due AC Power Source Schaffner NSG 1007 134 5/26/2016 5/26/2017 Signal Conditioning Unit Schaffner CCN 1000-1 133 5/26/2016 5/26/2017 TEST INFORMATION Date: 2/01/2017 Project No: 11473017 Tester: 29427 EUT Mode of Operation: Normal RESULTS EUT Classification Results Class A Class B Class C Class D Pass Fail Page 39 of 97

C u r r e n t ( A m p s ) V o l t a g e ( V o l t s ) REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 TRANSITORY POWERLINE HARMONICS RESULTS SUMMARY EUT: LED Illuminator Tested by: 29427 TN Test category: Class-A per Ed. 4.0 (2014) (European limits) Test Margin: 100 Test date: 2/1/2017 Start time: 1:52:18 PM End time: 2:02:39 PM Test duration (min): 10 Data file name: H-000475.cts_data Comment: Model P1347 Customer: Techni-Quip #11473017 Test Result: Pass Source qualification: Normal VOLTAGE & CURRENT WAVEFORMS Current & voltage waveforms 1. 8 1. 2 0. 6 0. 0-0. 6-1. 2 300 200 100 0-1 0 0-2 0 0-3 0 0 Page 40 of 97

C u r r e n t R M S ( A m p s ) REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 CURRENT HARMONICS CHART Harmonics and Class A limit line European Limits 3. 5 3. 0 2. 5 2. 0 1. 5 1. 0 0. 5 0. 0 4 8 12 16 20 24 28 32 36 40 H a r m o n i c # PARAMETERS VALUES Highest parameter values during test: V_RMS (Volts): 230.00 Frequency(Hz): 50.00 I_Peak (Amps): 1.115 I_RMS (Amps): 0.383 I_Fund (Amps): 0.323 Crest Factor: 2.922 Power (Watts): 67.5 Power Factor: 0.771 Page 41 of 97

CURRENT HARMONICS Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.179 1.080 16.5 0.179 1.620 11.1 Pass 3 0.090 2.300 3.9 0.091 3.450 2.6 Pass 4 0.026 0.430 6.0 0.027 0.645 4.1 Pass 5 0.013 1.140 1.1 0.013 1.710 0.8 Pass 6 0.008 0.300 2.6 0.008 0.450 1.9 Pass 7 0.007 0.770 0.9 0.008 1.155 0.7 Pass 8 0.005 0.230 N/A 0.006 0.345 N/A Pass 9 0.004 0.400 N/A 0.005 0.600 N/A Pass 10 0.001 0.184 N/A 0.002 0.276 N/A Pass 11 0.001 0.330 N/A 0.002 0.495 N/A Pass 12 0.004 0.153 N/A 0.005 0.230 N/A Pass 13 0.004 0.210 N/A 0.004 0.315 N/A Pass 14 0.004 0.131 N/A 0.005 0.197 N/A Pass 15 0.002 0.150 N/A 0.003 0.225 N/A Pass 16 0.003 0.115 N/A 0.003 0.173 N/A Pass 17 0.001 0.132 N/A 0.002 0.198 N/A Pass 18 0.001 0.102 N/A 0.001 0.153 N/A Pass 19 0.001 0.118 N/A 0.002 0.178 N/A Pass 20 0.001 0.092 N/A 0.002 0.138 N/A Pass 21 0.003 0.107 N/A 0.004 0.161 N/A Pass 22 0.002 0.084 N/A 0.002 0.125 N/A Pass 23 0.001 0.098 N/A 0.001 0.147 N/A Pass 24 0.001 0.077 N/A 0.001 0.115 N/A Pass 25 0.001 0.090 N/A 0.002 0.135 N/A Pass 26 0.001 0.071 N/A 0.002 0.107 N/A Pass 27 0.002 0.083 N/A 0.002 0.125 N/A Pass 28 0.002 0.066 N/A 0.003 0.099 N/A Pass 29 0.002 0.078 N/A 0.002 0.116 N/A Pass 30 0.001 0.061 N/A 0.001 0.092 N/A Pass 31 0.001 0.073 N/A 0.002 0.109 N/A Pass 32 0.002 0.058 N/A 0.002 0.086 N/A Pass 33 0.002 0.068 N/A 0.002 0.102 N/A Pass 34 0.001 0.054 N/A 0.002 0.081 N/A Pass 35 0.001 0.064 N/A 0.001 0.096 N/A Pass 36 0.001 0.051 N/A 0.002 0.077 N/A Pass 37 0.001 0.061 N/A 0.002 0.091 N/A Pass 38 0.001 0.048 N/A 0.001 0.073 N/A Pass 39 0.001 0.058 N/A 0.001 0.087 N/A Pass 40 0.001 0.046 N/A 0.001 0.069 N/A Pass Page 42 of 97

VOLTAGE SOURCE VERIFICATION Harm# Harmonics V-rms Limit V-rms % of Limit Status 2 0.089 0.460 19.39 OK 3 0.489 2.070 23.62 OK 4 0.042 0.460 9.16 OK 5 0.039 0.920 4.25 OK 6 0.019 0.460 4.14 OK 7 0.019 0.690 2.69 OK 8 0.016 0.460 3.43 OK 9 0.015 0.460 3.37 OK 10 0.012 0.460 2.55 OK 11 0.014 0.230 5.88 OK 12 0.016 0.230 6.89 OK 13 0.009 0.230 3.82 OK 14 0.013 0.230 5.47 OK 15 0.008 0.230 3.39 OK 16 0.015 0.230 6.58 OK 17 0.015 0.230 6.32 OK 18 0.018 0.230 8.02 OK 19 0.009 0.230 4.11 OK 20 0.019 0.230 8.19 OK 21 0.010 0.230 4.20 OK 22 0.010 0.230 4.41 OK 23 0.006 0.230 2.68 OK 24 0.007 0.230 3.20 OK 25 0.005 0.230 2.18 OK 26 0.014 0.230 5.99 OK 27 0.006 0.230 2.58 OK 28 0.012 0.230 5.34 OK 29 0.010 0.230 4.24 OK 30 0.009 0.230 3.90 OK 31 0.010 0.230 4.17 OK 32 0.009 0.230 3.98 OK 33 0.013 0.230 5.55 OK 34 0.005 0.230 2.04 OK 35 0.005 0.230 2.16 OK 36 0.006 0.230 2.49 OK 37 0.007 0.230 2.96 OK 38 0.006 0.230 2.46 OK 39 0.005 0.230 2.23 OK 40 0.007 0.230 3.16 OK Page 43 of 97

6.4. AC MAINS VOLTAGE FLUCTUATIONS AND FLICKER LIMIT IEC 61000-3-3 TEST PROCEDURE IEC 61000-3-3 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due AC Power Source Schaffner NSG 1007 134 5/26/2016 5/26/2017 Signal Conditioning Unit Schaffner CCN 1000-1 133 5/26/2016 5/26/2017 TEST INFORMATION Date: 2/01/2017 Project No: 11473017 Tester: 29427 EUT Mode of Operation: Normal RESULTS Test Results Pass Fail Page 44 of 97

VOLTAGE FLUCTUATIONS AND FLICKER RESULTS SUMMARY EUT: LED Illuminator, M/N P1347 Tested by: 29427 TN Test category: All parameters (European limits) Test Margin: 100 Test date: 2/1/2017 Start time: 2:07:23 PM End time: 2:17:54 PM Test duration (min): 10 Data file name: F-000476.cts_data Comment: EUT fully exercised Customer: Techni-Quip # 11473017 Test Result: Pass Status: Test Completed PARAMETER VALUES Parameter values recorded during the test: Vrms at the end of test (Volt): 229.90 Highest dt (%): 0.00 Test limit (%): N/A N/A T-max (ms): 0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.064 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.028 Test limit: 0.650 Pass Page 45 of 97

P l t P s t 1 4 : 1 7 : 5 3 1 4 : 1 7 : 5 3 REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 SHORT TERM CHART Pst i and limit line European Limits 1. 0 0 0. 7 5 0. 5 0 0. 2 5 LONG TERM CHART Plt and limit line 0. 5 0 0. 2 5 0. 0 0 Page 46 of 97

7. EN 60601-1-2 IMMUNITY REQUIREMENTS 7.1. PERFORMANCE CRITERIA EN/IEC 60601-1-2 Under the test conditions specified in 6.2, the ME EQUIPMENT or ME SYSTEM shall be able to provide the BASIC SAFETY and ESSENTIAL PERFORMANCE. The following DEGRADATIONS, if associated with BASIC SAFETY and ESSENTIAL PERFORMANCE, shall not be allowed: component failures; changes in programmable parameters; reset to factory defaults (MANUFACTURER S presets); change of operating mode; false alarms; cessation or interruption of any intended operation, even if accompanied by an alarm; initiation of any unintended operation, including unintended or uncontrolled motion, even if accompanied by an alarm; error of a displayed numerical value sufficiently large to affect diagnosis or treatment; noise on a waveform in which the noise would interfere with diagnosis, treatment or monitoring; artifact or distortion in an image in which the artifact would interfere with diagnosis, treatment or monitoring; failure of automatic diagnosis or treatment ME EQUIPMENT and ME SYSTEMS to diagnose or treat, even if accompanied by an alarm. For ME EQUIPMENT and ME SYSTEMS with multiple FUNCTIONS, the criteria apply to each FUNCTION, parameter and channel. The ME EQUIPMENT or ME SYSTEM may exhibit DEGRADATION of performance (e.g. deviation from MANUFACTURER S specifications) that does not affect BASIC SAFETY or ESSENTIAL PERFORMANCE. Page 47 of 97

MANUFACTURER S STATEMENT OF ACCEPTABLE PERFORMANCE The device is intended to be immune to PERMANENT DAMAGE from IMMUNITY testing at the levels set forth in 60601. PERMANENT DAMAGE shall be defined as a permanent, irreversible change to the condition of any components (i.e. damaged capacitors, etc.). It is permissible for the device s function to be impaired which shall be defined as a condition unique from PERMANENT DAMAGE in which some aspect of the functionality is temporarily impaired but the device can be returned to full functionality by removing the EMI source and cycling AC MAINS power on the device. For purposes of immunity testing basic safety can be determined by monitoring the functionality of the device. For example, the device should not suffer a significant increase in temperature, should not present shock hazards, should not arc, etc. In other words the device should be monitored to ensure it is either operating normally or if impaired is impaired in such a manner that no safety hazards present themselves. Page 48 of 97

7.2. ELECTROSTATIC DISCHARGE TEST LEVEL EN 60601-1-2 IEC 60601-1-2 Contact Discharge: ± 8 kv Air Discharge: ± 2 kv, ± 4 kv, ± 8 kv, ± 15 kv TEST PROCEDURE IEC 61000-4-2 EN 60601-1-2 IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due ESD Simulator Teseq Inc. NSG 437 995 10/10/2015 10/10/2017 Static Charge Monitor Wescorp W210A 690 N/A N/A Temp/Humidity/ Pressure Meter Cole-Parmer 90080-02 1576 02/19/2016 02/19/2017 ENVIRONMENTAL CONDITIONS Parameter Value Limits Temperature 22.6 C 15 C to 35 C Humidity 41% 30 % to 60 % Pressure 1012mbar 860 mbar to 1060 mbar TEST INFORMATION Date: 1/31/2017 and 2/1/2017 Project No: 11473017 Tester: 29427_TN EUT Mode of Operation: Normal Page 49 of 97

DIRECT CONTACT DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 1) TABLE TOP PHOTOGRAPHS OF DIRECT CONTACT DISCHARGE POINTS FRONT andtop DIRECT CONTACT DISCHARGE Page 50 of 97

DIRECT CONTACT DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 BACK and RIGHT DIRECT CONTACT DISCHARGE Page 51 of 97

DIRECT CONTACT DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 LEFT DIRECT CONTACT DISCHARGE Page 52 of 97

DIRECT AIR DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 PHOTOGRAPHS OF DIRECT AIR DISCHARGE POINTS FRONT DIRECT AIR DISCHARGE Page 53 of 97

DIRECT AIR DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 BACK DIRECT AIR DISCHARGE Page 54 of 97

DIRECT AIR DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 LEFT and TOP DIRECT AIR DISCHARGE Page 55 of 97

DIRECT AIR DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 RIGHT DIRECT AIR DISCHARGE Page 56 of 97

PHOTOGRAPH OF HCP AND VCP FOR INDIRECT CONTACT DISCHARGE TESTS VCP HCP Page 57 of 97

DIRECT CONTACT DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 2) POLE-MOUNT PHOTOGRAPHS OF DIRECT CONTACT DISCHARGE POINTS FRONT and TOP DIRECT CONTACT DISCHARGE Page 58 of 97

DIRECT CONTACT DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 BACK and BOTTOM DIRECT CONTACT DISCHARGE Page 59 of 97

DIRECT CONTACT DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 FRONT and LEFT DIRECT CONTACT DISCHARGE Page 60 of 97

DIRECT AIR DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 PHOTOGRAPHS OF DIRECT AIR DISCHARGE POINTS FRONT DIRECT AIR DISCHARGE Page 61 of 97

DIRECT AIR DISCHARGE REPORT NO: 11473017-E1V1 DATE: MAY 15, 2017 BACK DIRECT AIR DISCHARGE Page 62 of 97

INDIRECT HCP AND VCP DISCHARGE Page 63 of 97

RESULTS Test Points Front Back Left Right Top Bottom Direct Contact Discharge Test Levels Results 8 kv Pass Fail Front Back Left Right Top Test Points Direct Air Discharge Test Levels Results 2 kv 4 kv 8 kv 15 kv Pass Fail Test Points Front Back Left Right Indirect Contact Discharge to Horizontal Coupling Plane Results 8 kv Pass Fail Test Points Front Back Left Right Indirect Contact Discharge to Vertical Coupling Plane Results 8 kv Pass Fail Notes: For Pole_Mount No anomalies observed. The EUT functioned as expected according to manufacturer s instructions. For Table Top: applying discharge around the LCD status indicator at the +/- 15kV air discharge level caused the LCD indicator to go out. However, the light output was still on and not affected. Unit was manually powered off and back on, which restored the display screen. Page 64 of 97

7.3. RADIO FREQUENCY ELECTROMAGNETIC FIELD IMMUNITY TEST LEVEL EN 60601-1-2 IEC 60601-1-2 3 V/m, 80 MHz to 2.7 GHz in 1% increments (Professional Use) 80 % Sinusoidal AM at 1000 Hz, 3 Seconds dwell time TEST PROCEDURE IEC 61000-4-3 EN 60601-1-2 IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due Signal Generator Agilent MXG, N5183A 454 04/15/2016 04/15/2017 RF Amplifier Amplifier Research 150W1000M2 N/A C.N.R C.N.R RF Amplifier Amplifier Research 30S1G3 519 C.N.R C.N.R Directional Coupler Werlatone C6021 67 C.N.R C.N.R Directional Coupler Amplifier Research DC7144A 524 C.N.R C.N.R Power Meter HP/Agilent N1914A 254 06/24/2016 06/24/2017 Power Sensor HP/Agilent E9304A 255 06/24/2016 06/24/2017 Power Sensor HP/Agilent E9304A 256 06/24/2016 06/24/2017 Log Periodic Antenna Rohde & Schwarz HL 046 620 C.N.R C.N.R Horn Antenna EMCO 3115 59 C.N.R C.N.R Field Probe Holaday HI-6153 597 12/15/2015 12/15/2016 Radiated immunity s/w UL UL EMS ver. 9.5, dated August 16, 2016 ENVIRONMENTAL CONDITIONS Parameter Value Limits Humidity 46% < 95 % Page 65 of 97

TEST INFORMATION Date: 2/6/2017 Project No: 11473017 Tester: 45250 EUT Mode of Operation: Normal RESULTS Frequency Range (MHz) Antenna Polarization 80 to 2700 Horizontal 80 to 2700 Vertical Enclosure Port Front Side Back Side Left Side Right Side Pass Fail Pass Fail Pass Fail Pass Fail Frequency Range (MHz)* 80 to 2700 Horizontal 80 to 2700 Vertical Enclosure Port Antenna Top Bottom Polarization Pass Fail Pass Fail The EUT was tested at the following frequencies with a dwell time of 1 seconds: 385, 450, 710, 745, 785, 810, 870, 930, 1720, 1845,1970, 2450, 5240, 5500 and 5785 MHz with the corresponding modulations and test level indicated in Table 9 of IEC 60601-1-2:2014. Notes: 1) The test was performed on AC power port at the rated input voltage 120VAC, 60 Hz 2) No anomalies observed. The EUT functioned as according to manufacturer s instructions. Page 66 of 97

7.4. FAST TRANSIENTS, COMMON MODE IMMUNITY TEST LEVEL EN 60601-1-2 IEC 60601-1-2 2 kv open circuit voltage for AC Mains power input port 1 kv open circuit voltage for I/O signal & interconnecting ports Test was performed at 230Vac, 50 Hz TEST PROCEDURE IEC 61000-4-4 EN 60601-1-2 IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due EFT Generator Teseq NSG 3060 1530 03/21/2016 03/21/2017 Coupling Network Teseq CDN 3061 1529 03/21/2016 03/21/2017 Capacitive Clamp Teseq CDN 3425 1528 03/21/2016 03/21/2017 ENVIRONMENTAL CONDITIONS Parameter Value Limits Humidity 41 % < 95 % TEST INFORMATION Date: 1/31/2017 Project No: 11473017 Tester: 29427 EUT Mode of Operation: Normal Page 67 of 97

RESULTS AC Mains Power Port Test Level Test Voltage Test Voltage Polarity 1 0.25 kv Positive / Negative 2 0.5 kv Positive / Negative 3 1 kv Positive / Negative 4 2 kv Positive / Negative Results Pass Fail Notes: 1. No anomalies observed. The EUT functioned according to manufacturer s instructions. 2. testing was not required on the d.c. power port, since it is not intended to be permanently connected to cables longer than 3 m. Page 68 of 97

7.5. SURGES TEST LEVEL EN 60601-1-2 IEC 60601-1-2 AC Power Line with Ground: ± 0.5 kv (Differential Mode & Common Mode) ± 1.0 kv (Differential Mode & Common Mode) ± 2.0 kv (Common Mode) 5 surges applied per polarity at 0 º, 90 º, 270 º phase angles Test was performed at 230Vac, 50 Hz TEST PROCEDURE IEC 61000-4-5 EN 60601-1-2 IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due Surge Generator Teseq NSG 3060 1530 03/21/2016 03/21/2017 Coupling Network Teseq NSG 3060 1533 03/22/2016 03/22/2017 Decoupling Unit Teseq CDN HSS-2 1565 03/21/2016 03/21/2017 ENVIRONMENTAL CONDITIONS Parameter Value Limits Humidity 40 % < 95 % TEST INFORMATION Date: 1/31/2017 Project No: 11473017 Tester: 29427 EUT Mode of Operation: Normal Page 69 of 97

RESULTS AC Mains Port Test Level Surge Voltage Phase Angles Path 1 0.5 kv 0, 90, 270 LINE-LINE 2 1 kv 0, 90, 270 LINE-LINE 1 0.5 kv 0, 90, 270 LINE-GND 2 1 kv 0, 90, 270 LINE-GND 3 2 kv 0, 90, 270 LINE-GND Results Pass Fail Notes: 1. The test was performed on AC power port at the rated input voltage of 230V, 50 Hz 2. No anomalies observed. The EUT functioned as according to manufacturer s instructions. 3. No testing was required on the DC power port since the cable length is less than 10 m. Page 70 of 97

7.6. RADIO FREQUENCY, COMMON MODE IMMUNITY TEST LEVEL EN 60601-1-2 IEC 60601-1-2 3 Vrms, 150 khz to 80 MHz 1 % frequency increments, 1 second dwell time 80 % Sinusoidal AM at 1000 Hz Test was performed at 230Vac, 50 Hz TEST PROCEDURE IEC 61000-4-6 EN 60601-1-2 IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due Signal Generator Agilent MXG, N5183A 454 04/15/2016 04/15/2017 RF Amplifier Amplifier Research 75A250 520 C.N.R C.N.R Attenuator Bird 300-A-FFN-06 1354 C.N.R C.N.R CDN FCC FCC-801-M3-16A 367 03/08/2016 03/08/2017 Spectrum Analyzer HP 8546A 501 09/02/2016 09/02/2017 Current Clamp Fischer F-33-1 180 C.N.R C.N.R EMI Clamp Teseq KEMZ 801A 725 12/13/2016 12/13/2017 Power Meter HP 437B 220 08/30/2016 08/30/2017 Power Meter Sensor HP 8482A 440 06/17/2016 06/17/2017 Conducted immunity s/w UL UL EMS ver. 9.5, dated February 7, 2013 Page 71 of 97

ENVIRONMENTAL CONDITIONS Parameter Value Limits Humidity 40% < 95 % TEST INFORMATION Date: 1/27/2017 Project No: 11473017 Tester: 29427 EUT Mode of Operation: Normal RESULTS Frequency Range 150 khz to 80 MHz AC Mains Port Coupling Type Results CDN Current Clamp Pass Fail Notes: 1. The test was performed on AC power port at the rated input voltage of 230V, 50 Hz 2. No anomalies observed. The EUT functioned as according to manufacturer s instructions. 3. testing was not required on the d.c. power port, since it is not intended to be permanently connected to cables longer than 3 m. Page 72 of 97

7.7. MAGNETIC FIELD IMMUNITY TEST LEVEL EN 60601-1-2 IEC 60601-1-2 30 A/m RMS @ 50 & 60 Hz power frequency TEST PROCEDURE IEC 61000-4-8 EN 60601-1-2 IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Description Manufacturer Model AC Power Source ACS Test Equipment List AFC-10K- AFC-2 Local ID (T No.) Cal Date 134 CNR Cal Due Gaussmeter F.W. Bell 4190 204 1/23/2017 1/23/2018 Current Transformer Fluke 80i-600A 583 6/20/2016 6/20/2017 Digital Multimeter Fluke 45 431 5/9/2016 5/9/2017 1 m x 1 m Square Loop Haefely 073 696.1 1285 CNR ENVIRONMENTAL CONDITIONS Parameter Value Limits Humidity 40% < 95 % Ambient Magnetic Field 07µT < 0.12 µt Page 73 of 97

TEST INFORMATION Date: 2/1/2017 Project No: 11473017 Tester: 29427 EUT Mode of Operation: Normal RESULTS At 50 Hz, 30 A/m Enclosure Port Results Orientation Pass Fail X - axis Y - axis Z - axis At 60 Hz, 30 A/m Enclosure Port Results Orientation Pass Fail X - axis Y - axis Z - axis Notes: 1. The test was performed on AC power port at the rated input voltage of 120/230V, 60/50 Hz 2. No anomalies observed. The EUT functioned as according to manufacturer s instructions. Page 74 of 97

7.8. AC MAINS VOLTAGE DIPS AND INTERRUPTIONS TEST LEVEL EN 60601-1-2 IEC 60601-1-2 50Hz Level Periods For Reference Phase Angle Reduction Time 0 % residual 0.5 cycle 0º, 45º, 90º, 135º, 180º, 225º, 315º 100 % Dip 10 ms 0 % residual 1 cycle 0º 100 % Dip 20 ms 70 % residual 25 cycles 0º 30 % Dip 500 ms 0 % residual 250 cycles 0º 100 % Interruption 5000 ms 60Hz Level Periods For Reference Phase angle Reduction Time 0 % residual 0.5 cycle 0º, 45º, 90º, 135º, 180º, 225º, 315º 100 % Dip 10 ms 0 % residual 1 cycle 0º 100 % Dip 20 ms 70 % residual 30 cycles 0º 30 % Dip 600 ms 0 % residual 300 cycles 0º 100 % Interruption 6000 ms TEST PROCEDURE IEC 61000-4-11 EN 60601-1-2 IEC 60601-1-2 TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due AC Power Source Schaffner NSG 1007 134 5/26/2016 5/26/2017 Signal Conditioning Unit Schaffner CCN-1000-1 133 5/26/2016 5/26/2017 ENVIRONMENTAL CONDITIONS Parameter Value Limits Humidity 51 % < 95 % Page 75 of 97

TEST INFORMATION Date: 1/31/ and 2/01/2017 Project No: 11473017 Tester: 29427 EUT Mode of Operation: Normal RESULTS At minimum voltage, 100VAC, 60 Hz Level Period Results Pass Fail >95 % Dip <5 % residual 60 % Dip 40 % residual 30 % Dip 70 % residual >95 % Interruption <5 % residual 0.5 cycle 10 ms 5 cycle 100 ms 25 cycles 500 ms 250 cycles 5000 ms At maximum voltage, 240VAC, 50 Hz Level Period Results Pass Fail >95 % Dip <5 % residual 60 % Dip 40 % residual 30 % Dip 70 % residual >95 % Interruption <5 % residual 0.5 cycle 10 ms 5 cycle 100 ms 25 cycles 500 ms 250 cycles 5000 ms Notes: 1. The test was performed on AC power port at the rated input minimum voltage of 100_V, 60 Hz and maximum voltage of 240VAC, 50 Hz 2. No anomalies observed. The EUT functioned as according to manufacturer s instructions. Page 76 of 97

7.9. VARIATIONS OF POWER FREQUENCY TEST LEVEL EN 60601-1-2 IEC 60601-1-2 TEST PROCEDURE EN 60601-1:2012 IEC 60601-1:2012 EN 60601-1-2 IEC 60601-1-2 Duration of operation should be long enough to run through a full cycle of EUT operation. If there are multiple operating modes, each mode should be tested. TEST AND MEASUREMENT EQUIPMENT Test Equipment List Description Manufacturer Model Local ID (T No.) Cal Date Cal Due AC Power Source Schaffner NSG 1007 134 5/26/2016 5/26/2017 Signal Conditioning Unit Schaffner CCN-1000-1 133 5/26/2016 5/26/2017 ENVIRONMENTAL CONDITIONS Parameter Value Limits Humidity 42 % < 95 % TEST INFORMATION Date: 1/29/2017 Project No: 11473017 Tester: 29427 EUT Mode of Operation: Normal Page 77 of 97

RESULTS For 60 Hz product Test voltage: 100V Power line frequency Hz Mode description Duration of operation (minutes) Observation 59 Light ON 1 ON no change 61 1 ON no change For 50 Hz product Test voltage: 240V Power line frequency Hz Mode description Duration of operation (minutes) Observation 49 Light ON 1 ON no change 51 1 ON no change Notes: No anomalies observed. The EUT functioned as expected according to manufacturer s instructions. Page 78 of 97

8. SETUP PHOTOS 8.1. EMISSIONS RADIATED EMISSIONS TABLE TOP FRONT BACK Page 79 of 97

POLE-MOUNT FRONT BACK Page 80 of 97

AC MAINS LINE CONDUCTED EMISSIONS Table Top FRONT BACK Page 81 of 97

Pole-Mount FRONT BACK Page 82 of 97

AC MAINS HARMONIC CURRENT EMISSIONS AC MAINS LINE VOLTAGE FLUCTUATIONS AND FLICKER Page 83 of 97

8.2. IMMUNITY ELECTROSTATIC DISCHARGE TABLE TOP ESD POLE-MOUNT ESD Page 84 of 97

RADIATED IMMUNITY FRONT BACK Page 85 of 97

LEFT RIGHT Page 86 of 97

TOP BOTTOM Page 87 of 97

ELECTRICAL FAST TRANSIENT (AC MAINS) Page 88 of 97

SURGE (AC MAINS) Page 89 of 97

RF CONDUCTED IMMUNITY (AC MAINS) Page 90 of 97

POWER FREQUENCY MAGNETIC FIELD IMMUNITY X ORIENTATION Y ORIENTATION Page 91 of 97

Z ORIENTATION POWERLINE VOLTAGE DIPS AND INTERRUPTIONS Page 92 of 97