Product information. Front-door station series with video for surface-mount

Similar documents
(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

STX Stairs lighting controller.

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM

WaterVue TV Installation & User Manual

CM-S38901SV TVL IR Long Range camera

Video Door Entry System Kits 2 Wires Installation

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

Indoor/Outdoor Security System with Quad Monitor User s Manual

Standard signal metering in wall-mounting case

CM-S23349SV. Vari-Focal IR Bullet Camera

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Outdoor IR Audio Camera

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Description Diagram Page

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button.

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Business Display Solutions - Institutional Television Mirror TV. Installation Guide for 32PM8822 ( BDL3221M) 42PM8822 (BDL4221M)

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Luminaire installation box Surface-mounted box Ceiling installation box

Installation & User Manual For. Styluscom. Wired Video Intercom System. Models StylusAB, StylusABK, StylusAS Manual Version 1.

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Tectiv 220 Instructions for use

INSTALLATION MANUAL. ST-CVTMD420-WPIR-W Covert Motion Detection Color Camera. v1.3 8/11/11 1

2.4GHz Digital Wireless Peephole Viewer User Manual Contents

LCD Thermometer / Clock S No. 1253

Installation Guide VL-MV10. Model No.

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Optical Signal Devices. Free-standing Beacons

Level Measurement silometer FMC 420, FMC 423

Technical Specifications

User Manual Color video door phone

Doorphone Video Intercom

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR


SquareLED - Aura Bar & Matrix Beam Light 100

2.0 Wall Mount TV Soundbar Instruction Manual

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

Projector Lift. User Guide INSTALLATION OPERATION SETUP PROGRAM IR REMOTE FACTORY RESET

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

Sensor technologies Proximity sensors Series ST4. Brochure

Interface Connectors for Miniature, Portable Terminal Devices

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Connecting cables NEBS, for sensors

LED bar- Built-in constant current - 105Lm/W-thin 5.5mm-waterproof

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components

Spectra Batten (Order code: LEDJ95)

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA

INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:

User Manual Color Video Door Phone

DMX Operator 192-channel lighting controller

LED Backlight for Technics amplifiers

HDCVI Camera User s Manual

Documentation VFD clock 8 a clock

2.4GHz Digital Wireless Video Door Phone User Manual

HDMI Cross Converter

Operating Manual. Basic Control BC16. two-channel for eco moon

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Operation Manual VMS 3.0 Video System

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

FOREST SHUTTLE S / L / M RECEIVER

Figure 1: Device components

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

INSTRUCTION MANUAL. Made in the U.S.A. by USA Dance Floor. Copyright 2017 USA Dance Floor, LLC

Product Manual. Designed and Manufactured in the UK by Optikinetics

VITEK VTM-TLM191 VTM-TLM240

Nixie Clock Type Frank 3

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

LED-Strip C12 MK2.6. Product Sheet

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

POINTS POSITION INDICATOR PPI4

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

HAND-FREE COLOR VIDEO DOORPHONE. Installation and Operation Manual

HDCVI Camera User s Manual

7 Lighting Technology

1440/2880 HP RGB+WW+CW

Gamma instabus. Technical product information

Transcription:

Product information Front-door station series with video for surface-mount series VPES series VPDS

2 05/2006 Table of contents Scope of delivery...3 Safety notices...3 General notes on the cabling in TCS video systems...4 Terms for 5 wire and 6 wire operation...4 6 wire operation...4 5 wire operation...4 Device overview...5 Technical data...6 Application...6 Brief description...6 Basic functions...6 Additional functions...7 Assembly...7 Installing the video front-door station...7 Installation location...7 Installation height...7 Opening and closing the case...8 Cable connection...8 General notes...8 Connection...9 Wiring example...9 Connection diagram...9 Video commissioning...10 Microphone and loudspeaker volume setup...10 Nameplate labelling...10 Programming of s...11 Basic principle...11 Programming with the Service Device...11 Programming steps legend...11 Programming state of a...12 Testing...12 Deleting the...12 Programming a...13 Method 1: In-house station not accessible...13 Programming the other s:...13 Method 2: In-house station accessible...14 Programming the other s:...14 Programming an already programmed...15 Basic principle...15 Method 1: In-house station not accessible...15 Programming the other already programmed s...15 Method 2: In-house station accessible...16 Programming the other already programmed s...16 Repair...17 Replacing the EEPROM memory...17 Cleaning...17 Service...17

3 05/2006 Scope of delivery 1 x VPES / VPDS 1 x key for hexagon socket screws 1 x screwdriver with round handle name plates, empty and with light symbol product information Safety notices! Assembly, installation and commissioning must only be carried out by a qualified electrician! For work on systems with 230 V AC mains voltage the safety requirements of DIN VDE 0100 must be observed. When installing TCS:BUS systems the general safety rules for telecommunication systems in accordance with VDE 0800 must be observed: separate cabling for high and low voltage lines, minimum distance of 10 cm for joint cabling arrangements, use of separators between high and low voltage lines in joint cable ducts, use of standard telecommunication cables, e. g. J-Y (St) Y with 0.8 mm² cross section, existing cables (rnisation) with different cross sections may be used whilst taking account of the loop resistance.! Suitable lightning protection must ensure that a voltage of 32 V DC will not be exceeded at the TCS:BUS wires a and b.

4 05/2006 General notes on the cabling in TCS video systems Terms for 5 wire and 6 wire operation 6 wire operation standard operating. Video operation where two separate earths (b and M) are being used. 5 wire operation special operating. Video operation where b and M are joined to a single earth. 6 wire operation The cabling depends on the building situation and is only limited by its length. When selecting the cable length consider: the loop resistance M-P must be max. 8 Ω (table 1). For loop resistance > 8 Ω: provide for multiple wiring of the lines (twisted pairs). choice of line or star wiring Do not use more than 6 video in-house stations per line. For systems with more video in-house stations provide for the use of video distributors (VT02, VT04). up to 64 front-door stations and an almost unlimited number of in-house stations can be connected polarity-free (a/b) to a system. (use suitable power supply and control unit.) Table 1: Loop resistances Line length M-P Line diameter in m 0.6 mm 0.8 mm Loop resistance in Ω 10 1.22 0.69 20 2.45 1.38 30 3.67 2.07 40 4.90 2.76 50 6.12 3.44 60 7.35 4.13 70 4.82 80 5.51 90 6.20 100 6.89 5 wire operation Number of monitors in the system max. permissible loop resistance in Ω 24 4,8 12 6,3 6 8

5 05/2006 Device overview microphone loudspeaker loudspeaker cover loudspeaker volume control connection extension microphone volume control EEPROM connection terminal PES board Steckbrücke cable duct attachment holes 1, 2 lower panel attachment holes 3, 4 condensate drainage Shown is the VPES12, without name plate glass

6 05/2006 Technical data Supply voltage: 24 V ± 8 % (via power supply and control unit) Case: aluminium, anodised Name plate glass: plexiglass Operating temperature range: -20 C to 50 C Input current: I(a) = 2.8 ma, I(P) = 200 ma standby Maximum input current: I(Pmax) = 240 ma camera features bw-camera: CCD-sensor 380 TVL photo sensitivity: 0.2 Lux IR-LED-Illumination: for short distance focal length: f = 3.7 diagonal capture: 90 video output 1 Vpp composite video balanced based on the TCS-video system in a 6-wire technique Application VPDS, VPES are front-door station series with video for surface mounting for external use. Basic functions Brief description Bell buttons Saving the allocations in the front-door station Camera Image activation Image deactivation Operating a programmed triggers a ringing tone at the in-house station. Operating an unprogrammed triggers the light switch function in the power supply and control unit. When operating a an acknowledgement tone sounds. All programmed data (serial numbers and parameters) are stored in the EEPROM. If the front-door station requires replacement, the EEPROM board can be removed from the programmed front-door station and inserted into the new front-door station of identical design. black/white-camera, image activation constantly enabled (video signal always connected) with operation of a or operation of the function key (to switch on monitor / between cameras) on the video in-house station replacing the handset or automatic (preset time)

7 05/2006 Additional functions Name plate illumination Connection Allocation of serial number to s additional switching signal Via LED, P-wire connection required. for Service Device for connection for extension PET/PDT for protection ground 2 Use a combining device BRE2. Installing the video front-door station Assembly Installation location To achieve a good video quality the camera must not point directly at: sunlight, strong sources of light, bright or strongly reflecting walls. Installation height The installation height for the video frontdoor station must be selected under consideration of the field of capture of the camera (see figure). Persons with average body height are best captured with an installation height of 160 cm above floor level. 3.7 mm lens 90 diagonal capture angle

8 05/2006 Opening and closing the case 1. Opening the case The lower panel is attached to the aluminium profile by two hexagon socket screws. (1) Unscrew both screws using an key for hexagon socket screws only half way: (2) Turn the lower panel to the left, without removing it completely. (3) Slide the name plate glass fully down. 2. Feed the cables through the cable duct. 3. Attach the device safely to the wall from the attachment holes (see overview) using suitable screws. Take care not to pinch the cables under the spacers on the device back. 4. Closing the case Slide the name plate glass upwards under the front panel. Turn the lower panel to the right until the recess fits over the screw. Tighten the screws.! When sliding the name plate glass upwards take care not to damage the rubber seals in the guide grooves. When fitting additional devices make sure that you can slide the name plate glass of the device downwards out of the profile. Do not fit a device below the device.! Never seal the device using silicon! Condensate must be allowed to drain and evaporate. General notes! Cable connection Use the small screwdriver supplied to connect the lines and prevent damage to the device. Please note the lines should not be run in front of the LED to prevent obstruction of the nameplate illumination the lines must not be squeezed below the spacers on the back of the front-station.

9 05/2006 Connection 1. Strip the insulation from the line ends. 2. Connect the lines, depending on system type, in accordance with the wiring example / connection diagram. Option grounding: If there are interferences in specific surroundings, the shielding can be connected with G and PE on the distribution side. Wiring example floorswitch button floorswitch button Connection diagram

10 05/2006 Video commissioning! First fully install the system, then connect power! V1 and V2 must never - not even temporarily - be connected to the P, a or b wires. Such a connection would destroy the device. When connecting the video wires V1 (+) and V2 (-) the polarity must be observed. If the image is distorted after commissioning, switch off the device and replace the wires for the video signal. Microphone and loudspeaker volume setup! For adjustments use the small screwdriver supplied! The volumes have been set to an average value at factory. A modification may not always be necessary. When adjusting please note: The amplification of loudspeaker and microphone cannot be set independently from each other. Too great volume will cause a feedback effect (whistling). Volume control microphone In-house station volume adjustment loudspeaker Front-door station volume adjustment Nameplate labelling The templates are available on our website www.tcs-germany.com \ English\ Downloads \ System and technology basics\ Product installation and use \ labelling of the nameplate 1. Enter the desired name into the template. 2. Print the name plate on the special film* and cut it to size. 3. Insert the cut plates from the side into the pockets on the name plate glass. * We recommend to print the name plates on a durable special film. The film can be ordered directly from TCS: Writable polyester film for name plates DIN A4.

11 05/2006 Programming of s Basic principle All devices at the TCS:BUS have a unique serial number. During this serial number is transferred to the front-door station and linked to the. Programming with the Service Device Utilise the simple 1 person with the TCS Service Device. You will not need access to the in-house stations in the flats. The voltage supply is provided by connecting the Service Device to the TCS:BUS. For more on the TCS Service Sevice see: www.tcsgermany.de If you do not have the Service Device, you can also program manually. Programming steps legend briefly press key press key until release key continue wait until Delation tone LED flashes slowly LED flashes rapidly NoProg tone ring tone Prog2 tone Progsperr tone

12 05/2006 Programming state of a The front-door stations are supplied un-programmed. The state can be checked as follows: Testing press briefly Noprog tone ring tone un-programmed programmed Before a pre-programmed can be re-programmed, the must be deleted. Deleting the 1 2 LED flashes switched on 3 Press deletion tone release until sounds 1), deleted switched off LED flashes no more 1) If Progsperr ton sounds the block is active. It can be removed by the service device TCSK-01 only.

13 05/2006 Programming a Connect the in-house station to the TCS:BUS. Use one of these two methods. Method 1: In-house station not accessible 1 LED illuminates switched on 2 LED flashes 3 Floor-switch button within 3 sec: press 1 sec, until bell rings - release - press 1 sec until bell rings - release. programmed 4 ring tone sounds at front-door and in-house station 1) switched off LED illuminates Programming the other s: Step 1 repeat steps 2 and 3 each time complete the of all buttons with step 4

14 05/2006 Method 2: In-house station accessible 1 LED illuminates switched on 2 LED flashes programmed 3 Lift handset 2) press briefly, replace handset at in-house station ring tone sounds at in-house station at front-door and in-house station 1). switched off LED illuminates Programming the other s: Step 1 repeat step 2 each time for additional s where necessary complete the of all buttons with step 3 2) In-house stations without handset: to establish a voice communication press the speak button (resp. switch button speak / listen).

15 05/2006 Programming an already programmed Basic principle A can be linked to two serial numbers (of two in-house stations). It is then possible to have two different in-house stations ring at the same time. Connect the in-house stations to the TCS:BUS. Use one of these two methods. Method 1: In-house station not accessible 1 LED illuminates switched on 2 LED flashes 3 Floor-switch button within 3 sec: press 1 sec, until bell rings - release - press 1 sec until bell rings - release. programmed Press... and... and ring tone sounds release until Noprog tone at front-door and Prog2 tone sounds 1)... sounds in-house station. 4 LED illuminates switched off Programming the other already programmed s Step 1 repeat steps 2 and 3 each time complete the of all buttons with step 4

16 05/2006 Method 2: In-house station accessible 1 LED illuminates switched on 2 LED flashes programmed Lift handset 2) Press until...and... and ring tone release replace at the Prog2 tone Noprog tone sounds at handset in-house sounds 1) sounds front-door and at in-house station. in-house station. station. 3 switched off press briefly LED illuminates Programming the other already programmed s Step 1 repeat step 2 each time for additional s where necessary complete the of all buttons with step 3 Note Repeated of an already programmed always only changes the second serial number. If you want to change the first programmed serial number, you have to delete both serial numbers and then re-program both serial numbers.

17 05/2006 Repair Replacing the EEPROM memory All programmed data, like serial numbers and parameters, are stored in the EEPROM. If the front-door station requires replacement, the EEPROM board can be removed from the programmed front-door station and inserted into the new front-door station of identical design. Open the case. Pull the small PCB off the electronic board. Plug the EEPROM board onto the pins in the new un-programmed front-door station. Take care that all four poles of the plug are inserted into the jack of the small PCB and that the component side is visible. After replacement all is available again. Cleaning! Avoid water entering the device! Do not use any aggressive or abrasive cleaning agents! Clean the device using a dry or slightly moist cloth. More persistent dirt can be removed using a mild household cleaner. Service Contact your local sales representative or www.tcs-germany.com