Minimize your cost for Phased Array & TOFD

Similar documents
Minimize your cost for Phased Array & TOFD

Minimize your cost for Phased Array & TOFD

Super Idea for Ultrasonic Inspection

No. MME/INS/153/ Date: 27 August 2018 NOTICE INVITING TENDER

Digital Storage Oscilloscopes 2550 Series

SDS1000C Specifications

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

Advanced Test Equipment Rentals ATEC (2832)

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel.

Agilent 5345A Universal Counter, 500 MHz

2016 RIGOL TECHNOLOGIES, INC.

SMS3000X Series Spectrum Analyzer

Portable Performance for Debug and Validation

JD725A Cable and Antenna Analyzer - Dual Port

GFT Channel Digital Delay Generator

R3267/3273 Spectrum Analyzers

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

PicoScope 6407 Digitizer

User s Manual of Signal Level Meter TABLE OF CONTENTS

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

FLAT DISPLAY TECHNOLOGY

Specifications LED Display Video Controller VX4S

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Expect to Make Waves.

ADS1000C, CAL / CML Series

Specifications LED Display Video Controller VX4. Xi an NovaStar Tech Co., Ltd. Rev1.0.4 NS

2 MHz Lock-In Amplifier

DS2460Q QAM Analysis Meter

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

PicoScope 6407 Digitizer

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

ScopeMeter 190 Series Specifications

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

SATELLITE FINDER SK-3200 USER MANUAL

Specifications. Independent Controller MCTRL R5. Rev1.0.0 NS


RF Semiconductor Test AXRF RF Port Upgrade Kits

Inmarsat Downconverter Narrowband Downconverter

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

DataSheet. SDS1000DL Series Digital Oscilloscope

Multi-Frame Matrix Capture Common File Format (MFMC- CFF) Requirements Capture

R-1580A Microwave Downconverter. Product Brochure

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

Microwave Counter, Power Meter and DVM in One Portable Package

Analog Dual-Standard Waveform Monitor

Clamp 200 A AC/DC (+ V AC/DC + Ω)

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

Durable and Reliable Design for 24/7 Use. Overview. Narrow Bezel Optimized for Video Walls. 42 Narrow bezel commercial LED display

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S EDS300 DME/Pulse Analyzer Specifications

RPV and Primary Circuit Inspection. Pressure Vessel Inspection Codes for phased Arrays M. Moles, Olympus NDT, Canada

Wideband Downconverter Solutions

PRODUCT NO.: PT-L735NT PRODUCT NAME: Ultra Portable Wireless LCD Projector

Agilent Technologies 54522A

SSA3000X Series Spectrum Analyzer

Satellite locator WS-6933

Product Brochure. June M5 Series. Metal Detector

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

50 MHz Digital Storage Oscilloscope

SNG-2150C User s Guide

PRODUCT NO.: PT-L735 PRODUCT NAME: Ultra Portable LCD Projector

DataSheet SDS1000CFL Series Digital Oscilloscope

Simple all-in-one design style with front stereo speakers and natural ventilation system

ThinkRF D GHz RF Downconverter

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

GFT Channel Slave Generator

HITACHI. Instruction Manual VL-21A

XC-77 (EIA), XC-77CE (CCIR)

VGA to Video Converter ID# 424 Operation Manual

AND-TFT-25XS-LED-KIT. 160 x 234 Pixels LCD Color Monitor AND-TFT-25XS-LED-KIT. Features

TRIAX Meters. Measurement instruments using the latest technology to make your installation perfect

Advanced Test Equipment Rentals ATEC (2832)

S7000L. TV & Satellite Analyzer. All IN ONE. Satellite & Terrestrial. Key Features. Model Guide

Tablet Oscilloscope Quick Guide

GDB-03 Demo Module USER MANUAL GW INSTEK PART NO. 82DB-03000M01 ISO-9001 CERTIFIED MANUFACTURER

SC24 Magnetic Field Cancelling System

EX04-000D. DVB-T/2xT/T2 MODULATOR DVB MODULATOR

PROFESSIONAL D-ILA PROJECTOR DLA-G11

In-process inspection: Inspector technology and concept

TH-55LF80U. 55-inch Class FULL HD LCD Display. Product specification (design and specification subject to change without notice) DISPLAY PANEL

ST-4000D SIGNAL LEVEL METER

TH-42LF80U. 42-inch Class FULL HD LCD Display. Product specification (design and specification subject to change without notice) DISPLAY PANEL

PROFESSIONAL D-ILA PROJECTOR DLA-G11

Ultrasonic Probes & Accessories

PT-LW330 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/9.

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Transcription:

Minimize your cost for Phased Array & TOFD

Latest ultrasonic flaw detector from SIUI, incorporates the latest advancements in Encoder In/Out UT/ TOFD Probe high-performance Phased Array and TOFD detection into one compact and durable unit. SyncScan can be upgraded with Phased Array and TOFD to satisfy various inspection requirements. Indicator Superior Features 8.4 inch Function Keys Knob Power Key 90mm Light Weight: 3.75 kg with battery IP rate: IP65 Touch screen: 8.4" LCD with resolution 800 600 pixels Remote Control/ Ultracloud Function (Optional) PA: Multi-group Scanning, Weld Simulation/ Corrosion Software (Optional) TOFD: 1~4 channel TOFD for Selection Extendable connectors Reserved for version two:1/2/4-channel TOFD Probe UT/TOFD Probe Encoder In/Out Port USB:2 pcs Ethernet SD Card VGA Battery DC Power Phased Array Probe Probe Locker Top View Side View (Left) Side View (Right) Durable Robust housing based on IP65 to work in the harshest industrial environment. Good Sealing Rubber Bumpers

Upgradeable Upgradeable from UT to Phased Array or TOFD Version One upgradeable to 16:64 PAUT & 1-ch TOFD Conventional UT Version Two upgradeable to 1/2/4 TOFD * Please define the version when purchasing. Conventional UT Function Most advanced UT functions including API Software, TCG Software, AWS D1.1 Software, Real Time B Scan and Thickness are available as options. Phased Array Function SyncScan is compatible with special corrosion software for corrosion mapping and composite inspection, as well as multi-group scanning functions for weld inspection. Furthermore, simultaneous inspection of PA and TOFD can increase productivity in various inspection situations. Simultaneous Inspection of PA & TOFD(Optional) Simultaneous display of phased array and TOFD function can increase scanning coverage, decrease undetected rate and provide multiple detection methods. Multi-Group Scanning(Optional) For one phased array probe, multi groups of element and multi angles can be applied for scanning at the same time, fully covering the welding area and enhancing the inspection efficiency. Special Corrosion Software(Optional) Step-by-step wizard can guide users to finish setup easily and improve inspection speed. Easy to work out scan plan for pipeline corrosion inspection. Different thickness will be displayed in different colors, making it easier to determine corrosion situation. Data analysis is available.

File Info GroupNum Encoder Name Probe height Probe height Signature To facilitate new PA operators, SyncScan carries calibration wizard and scanning wizard with step-by-step menu to improve inpection speed. Scan Wizard This function is used to complete testing process design for the specific testing of work pieces, including the beam coverage simulation and phased-array imaging parameter settings. Beam Coverage Simulation Wizard Wizard Step-by-step menu guides users to calibrate velocity, delay, sensitivity and TCG Velocity TOFD Function For many people, TOFD inspection is very tricky and complicated. However, SIUI TOFD wizard can make TOFD user-friendly. TOFD Wizard With step-by-step menu to guide users to finish the TOFD scanning process easily and improve inspection speed. Upgradeable TOFD channel for selection meets various inspection needs. 1-channel TOFD 2-channel TOFD 4-channel TOFD PC-based Software Main functions: Checking data file; Measuring data analysis. Generating measurement reports Setup Info Images Vel Wedge length Wedge width Wedge height Scan depth Display delay Pulse voltage Pulse freq Pulse power PRF Receive freq Gain Scan line num / frame Echo type Material vel Scan type Start element End element Linear step Aperture Start angle(sector) End angle(sector) Remark Ultrasonic Test Report Company Workpiece SN Specs Material Surface Method Coupling Standard Class Date File name File type Machine Machine SN Module Module SN Software version Hardware version Frame num Scan mode Scan time step Scan encode step Scan encoder XMpp Scan encoder YMpp Machine Info Scanning Info Channel 1 Probe Info Wedge Info Probe model Frequency Pitch Element num Probe length Probe width Images Wedge model Angle First element height First element x Vel Wedge length Wedge width Wedge height Scan depth Display delay Pulse voltage Pulse freq Pulse power PRF Receive freq Gain Scan line num / frame Echo type Material vel Scan type Start element End element Linear step Aperture Start angle(sector) End angle(sector) Setup Info Channel 2 Probe Info Wedge Info Probe model Frequency Pitch Element num Probe length Probe width Remark Operator Wedge model Angle First element height First element x Probe model Frequency Pitch Element num Probe length Probe width Probe height Wedge model Angle First element height First element x Vel Wedge length Wedge width Wedge height Scan depth Display delay Pulse voltage Pulse freq Pulse power PRF Receive freq Gain Scan line num / frame Echo type Material vel Scan type Start element End element Linear step Aperture Start angle(sector) End angle(sector) Channel 2 Probe Info Wedge Info Setup Info Phased Array TOFD File Operator Signature Date: Report Date:

General Technical Specification General Technical Specification Display Screen 8.4 high brightness TFT LCD, 800 600 Dimension (W H D) 284 mm 220 mm 90 mm Weight 3.65 kg with battery Battery Smart lithium battery, 1 pc (0.55kg) 7.5 Ah/pc, operation time more than 4 hours Battery Capacity for PAUT, 5 hours for UT/TOFD. External Power Supply for AC 100-240V 50Hz/60Hz Adaptor Output 15V DC Power 20VA Data Storage Standard SD card (16G) General Technical Specification Input/Output USB Connector 2 pcs Ethernet Connector 1 pc Video Output VGA port Encoder Connector 1 pc (14-core) WIFI 1pc, Build-in Environment Tests Operation Temperature -10-45 Storage Temperature -20-60 IP Code IP65 Technical Specification for 16:64 PAUT and TOFD to achieve simultaneous inspection of PA & TOFD Conventional UT Phased Array TOFD System No. of Channel 1 16 1/2/4 Probe Connector LEMO 00, 2 pcs Tyco, 1 pc LEMO 00 (same connector as conventional UT) Max. Supporting Elements 2 64 2-8 Pulser Negative square Bi-polar square Negative square PRF Adjustable 20-2000Hz, step: 20Hz 100Hz-20KHz, step:100hz Adjustable 20-2000Hz, step: 20Hz Pulse Voltage 50V~500V, min. step 1V 10-110V, min step 2V 50V~500V, min. step 1V Pulse Frequency 2-10MHz, step 0.5MHz Pulse Energy 4 levels Pulse Width 30-1000ns, step:10ns 30-1000ns, step:10ns Damping 25/75/200/1000Ω,4 levels 25/75/200/1000Ω,4 levels Pulser Delay 0-20µs, resolution 5ns Pulser Focusing Single point focusing Receiver Gain 0-110dB, step:0.5/2/6/12db 0-80dB, step:0.1/0.5/2/6/12db 0-110dB, step: 0.5/2/6/12dB Bandwidth 0.5-20MHz(-3dB) 0.7-20MHz (-3dB) 0.5-20MHz(-3dB) A/D Sampling Rate 170MHz 100MHz 170MHz Rectification Positive/ Negative/ Full/ RF Positive/ Negative/ Full/ Filter RF Receiver Delay 0-20µs, resolution 2.5ns Receiver Focusing Max. range: 1008 foci per scan line Filter 6 levels: 10 levels: 6 levels: 0.5-5/0.5-10/ 1-4/0.5-10/2-20/ 0.7-4/2.5-7/4-8.5/7-10/ 3.5-10/0.5-15/ 1/2.5/4/5/10/13/15MHz 9-15/0.7-20 MHz 5-15/0.5-20MHz Reject 0-80%, step:1%

General Technical Specification Technical Specification for 16:64 PAUT and TOFD to achieve simultaneous inspection of PA & TOFD Conventional UT Phased Array TOFD Scan Scan Type A A/S/L/C/D A/ TOFD Trigger Mode Time-based/ Encoder Encoder Scan Length Max.90m Max.3m (encoder precision:0.5mm, 4-ch TOFD (encoder precision:0.5mm) working simultaneously) Scan Line Number Max.512 lines Scan Angle Range -89 ~+89, step 1 Angle Spacing 0.1-5, step 0.1 Line Average 4 levels, 1/2/4/8 Focus Position 6-500mm, step1mm Range 0-15000mm, min. display range is 5mm. 0-1000mm, min. step: 0.01mm 0-15000mm, min. step:0.1mm Material Velocity 500-15000m/s, min. step:1m/s 500-15000m/s, min. step:1m/s 500-15000m/s, min. step:1m/s Display Delay 0-1000mm, min. step: 0.01mm 0-1000mm, min. step: 0.01mm 0-1000mm, min. step: 0.01mm Probe Delay 0-200us, min. step: 0.01us 0-200us, min. step: 0.01us Probe Flank 0-100mm, step: 0.01mm 0-100mm, step: 0.01mm Wizard Scan wizard, DAC, AVG/ DGS, Angle calibration, auto velocity/ delay/ calibration sensitivity/ TCG calibration TOFD Auto Zero, Velocity Zero, Velocity, Delay, Sensitivity, TCG Test Point Selection Peak/ Flank/ J Flank Peak/ Flank/ J Flank Three gates: to measure echo amplitude, Three gates: to measure echo amplitude, amplitude db difference, sound path, horizontal distance, vertical distance sound path, horizontal distance, vertical distance. Two measurement cursors: to measure horizontal & vertical position and Flaw height and length measurement. distance between cursors. Gate Start Full range Full range Gate Width Full range Full range Gate Thresh 10-90%, step: 1% 10-90%, step: 1%

General Technical Specification Technical Specification for 16:64 PAUT and TOFD to achieve simultaneous inspection of PA & TOFD Curve Function Conventional UT Phased Array TOFD DAC: Max. 6 lines; AVG/DGS TCG: Max. 6 lines; Auxiliary Function Coordinates switch (sound path/depth/horizontal), auto gain (40~100%, step:10%), second leg color, wave compare, gate expansion, wave filling, auto freeze Auto gain Alarm Signal Signal and sound alarm: positive/ Signal and sound alarm: positive/ negative negative Display Measure Value 8 positions can be user-defined. Data Analysis Testing Index Image mode switch and image gate LW/BW straightening, LW/BW removal, dynamic reconstruction contrast adjust, gain adjust, zoom Time Base Linearity 0.5% Vertical Linearity 3% Amplitude Linearity ±2% Attenuator Precision 20dB±1dB Dynamic Range 32dB Software API Welding Simulation Can be upgraded to 2-ch TOFD TCG Simultaneous Display of PAUT and AWS D1.1 Optional Software TOFD Can be upgraded to 4-ch TOFD Real Time B scan Grouping Scanning Thickness Corrosion Scanning (C scan) CSC(Curved Surface Correction)