I-SERIES. A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement

Similar documents
Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

CDX series. World s No. 1 Linearity OPTEX FA CO., LTD. New models added. Ultra High-Accuracy Laser Displacement Sensor

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Cylindrical Photoelectric Sensor CY-100 SERIES

Photoelectric Sensors E3F2

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

NPN type (Analogue/Voltage/Dual) Laser type. PNP type (Analogue/Voltage/Dual) NPN type (RS422) PNP type (RS422) Pins configuration

Photoelectrics Through-beam Type PA18C.T..., DC

Absolute Rotary Encoder E6CP

Linear encoders without bearings incremental System for linear motion feedback

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button.

Separate Thin Amplifier type. AP-V40AW Series

APPLICATIONS. Automatic warehouse. Trasportation lines

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Detect Color and Shape for various inspection

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Ø50mm Shaft Multi-Turn Absolute Type

SA1J-F: Full Color Fiber Optic Sensors

In-process inspection: Inspector technology and concept

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Safety Light Curtains

SU17 Series Fiber Optic Sensors

W100L: Laser Sensor in Mini- Format

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Electrical connection

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

APPLICATIONS. Automatic warehouse. Trasportation lines

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

LUT Luminescence scanners: Seeing what no-one else can

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

ODW-621. RS-232 Point-to-point applications

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

Type F70AB F70ABPN. Digital display. Simple operation featured

Electrical connection

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Absolute Encoders Multiturn

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

SPACESCAN SERIES SS 02

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

ENC - LKE51 - L I B

LM10 linear magnetic encoder system

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Electrical connection

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

W 9-2: A Versatile, Complete and Compact Series

IMPAC Infrared Thermometers

Type. NPN output F71R F71G F71B F71W F71RH F71GH F71BH F71WH. Manual setting general-purpose type. Manual setting high-speed type

Safety Light Curtain Type4 SIL3 PLe

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Multifunction Digital Timer

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Transmitter optics with 9x white light LED (optics cover made of glass)

IMPAC Infrared Thermometers

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Magnetic Sensor - Incremental EHP

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Type SCH94FO. Type SCH94FO. Description

Fibre Optic Modem ODW-622

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

SCALE & WEIGHT DISPLAYS

Technical data. General specifications. Indicators/operating means

WF next: Fork sensors for a wide range of applications

Electrical connection

Safety Light Curtains GuardShield

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Datasheet - SRB-E-201ST

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

panasonic-electric-works.net/sunx Machine safeguarding without sacrificing productivity

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Datasheet - SRB301LC 24VAC/DC

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

>Inductive. REFERENCE guide. Proximity

True Color Sensor with Analog and Digital Outputs

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Transcription:

NEW CMOS Multi-Function Analogue Laser Sensor IL Series A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement Seam detection Thickness differentiation Thickness differentiation Height control Intelligent Sensor I-SERIES Low-cost High Performance INTRODUCING THE LASER APPLICATION SENSOR IL SERIES HEIGHT/ HEIGHT DIFFERENCE WARPAGE THICKNESS/WIDTH POSITIONING VIBRATION COUNT

VARIETY OF USES AT LOW COST Compact and lightweight laser displacement sensor Intelligent Rugged I SERIES Easy Intelligent High precision was achieved by using state of the art technology and functions specifi cally developed for high-accuracy measurement instruments. Rugged Developed for use in harsh environments, the IL Series was designed with a robust structure. Easy Excellent usability makes it possible to quickly and easily perform stable measurements without any diffi cult adjustments or settings. Low-cost High Performance The intelligent I-Series consists of a high-precision sensor lineup that realises low-cost and high performance with only the most advanced functions for on-site operations. Introducing the IL Series Intelligent Sensor I-SERIES 2

Rugged Intelligent I SERIES Easy High-Precision Head + Multi-Function Amplifier [Newly developed LSGC included] + [All-in-one design] The stable measurement of any given target is possible by sensing the target surface and adjusting the 600,000 times dynamic range. Furthermore, in order to further streamline communication with process control systems we have installed application specifi c functions into the compact amplifi er. Reduced power When the workpiece is highly refl ective Refl ection Power Increased power When the workpiece is dark Rugged Intelligent I SERIES Easy Rugged Head Structure [Die cast metal used for IP67/optical base] The head structure was redesigned to make it rugged enough to withstand almost any environment. In addition, the housing is made of die cast SUS304 for added strength and protection. Rugged Intelligent I SERIES Easy Compact Head Design + Easy Mounting [Smallest body in its class] + [Hi-fl ex cable] The IL Series has achieved the smallest head housing in its class by adopting the unique aspherical lens. The weight of the head is a mere 60g*. The sensor head cable is designed with a robot cable. This cable is specifi cally designed for high cycle service life and makes the sensor ideal for robotics or other high cycle applications. 20 million cycle service life (typical) Load (W): 250 g Bending radius: R50 mm Rate: 30 bends/minute (One bend is a cycle whereby the cable is bent from left to right and then from right to left.) Free Cut! R 90 L *IL-030 IL-600 Reference distance Measurement range Display Resolution Repeatability 600 mm 200 to 1000 mm 50 µm 300 µm IL-300 Reference distance Measurement range Display Resolution Repeatability 300 mm 160 to 450 mm 10 µm 50 µm IL-100 Reference distance Measurement range Display Resolution Repeatability 100 mm 75 to 130 mm 2 µm 10 µm IL-065 Reference distance Measurement range Display Resolution Repeatability 65 mm 55 to 105 mm 2 µm 4 µm IL-030 Reference distance Measurement range Display Resolution Repeatability 30 mm 20 to 45 mm 1 µm 2 µm 3

The multi-function amplifier with an all-in-one design Rugged Intelligent I SERIES Easy Direct connection with peripheral equipment Voltage / current analogue output Peripheral equipment PLC, etc. Analogue controller, etc. Hi / Go / Lo judgement output Data logger, etc. BCD output PC RS232C New mode Thickness calibration function included 3-step easy calibration With conventional devices, calibration had to be conducted on every individual sensor head, however, the IL Series has a dedicated mode that allows calibration to be completed in 3 simple steps. Bring the target close to one sensor Bring the same target used in Step 1 Step1 Step2 Step3 head and input the thickness data, close to the opposing sensor head and then push the set button. push the set button. Insert a target thicker than the target used in Step 2. Input the thickness data. Then pushing the set button completes calibration. When bringing the target closer to the sensor head in Steps 1 and 2, you are compensating for the misalignments that occur during installation. To set, you can begin with either one of the sensor heads. Ambient light elimination function included In order to counteract any ambient light interference, the IL Series automatically activates the ambient light elimination function when the sampling cycle is set to 2 ms or 5 ms, reducing the effects of ambient light. Laser Emission Off <A> CMOS exposed to laser emission <B> CMOS not exposed to laser emission = (Minus) (Equals) Sampling cycle The CMOS waveform of A Ambient light is present The CMOS waveform of B Ambient light only CMOS waveform (difference) Waveform where the ambient light has been removed 4

Multi-function amplifier CALCULATION FUNCTION Addition mode Subtraction mode Setting example 1 (thickness measurement) Setting example 2 (width measurement) Setting example 1 (Measurement of height difference) Setting example 2 (Measuring tilt) FUNCTION CHOICES NPN/PNP Output Selection (judgment selection) Both NPN and PNP outputs are supported. The outputs are set the fi rst time the user turns on the power. These settings can subsequently be changed. Judgments are output as HIGH, GO, or LOW. Bank Function The bank function can register up to four patterns of specifi c settings.* For example, in response to a measurement target changeover, this function allows the user to easily switch between the patterns of registered settings. * HIGH setting value, LOW setting value, shift value, analogue output scaling setting Analogue Output Selection The following fi ve types of analogue outputs can be selected. The output is selected the fi rst time the user turns on the power. Mounting method options Both panel and DIN-rail mount units are available. Setting Description value Not output Analogue output after the judgement value is converted to the range from 0 to 5 V. Analogue output after the judgement value is converted to the range of ±5 V. Analogue output after the judgement value is converted to the range from 1 to 5 V. Analogue output after the judgement value is converted to the range from 4 to 20 ma. The setting can be changed. IL-1500/1550 Panel mount type IL-1000/1050 DIN-rail mount type Communication Unit DL-RB1A BCD output unit Use this unit when retrieving numerical data from the IL Series to an external device as digital data. A single communication unit can retrieve data from up to 8 IL Series display units via BCD. DL-RS1A 1. RS-232C communication unit Use this unit when outputting digital data to an external device with RS-232C signals. In addition the unit can be used to externally program the amplifi ers. 1. D-sub 9 pin connector cable (OP-81283) can be used for connection. 5

Applications Height difference measurements of a plastic extrusion Provides constant monitoring by measuring the height using 2 sensors simultaneously, then calculates the height difference using the calculation function in the amplifi er. Reliable detection is possible even if the product type or colour changes. Warpage detection in ceramic boards As the sensor head is compact, multiple point measurements of small-scale boards are possible. By calculating the measurement data externally, simultaneous measurements of positioning and warpage are possible. Thickness/width measurements of building material boards Thickness and width can be simultaneously measured immediately after the extrusion process. In addition, man-hours for setup and product changeovers are reduced using the thickness calibration function. Packaging material counting Even in targets with a large amount of shape scatter, reliable counts can still be achieved by detecting rising edges. Accuracy checks on an automotive door assembly When assembling automotive doors, by simultaneously measuring multiple points, the assembly accuracy can be evaluated. Reliable detection is possible regardless of body colour. Positional control of welding beads Through external calculations of height data from the sensor, the device detects the position of the weld seam. Welding accuracy can be improved via measurement data feedback to the welder. Heat processing inspection of cans Height controls of a hoop material By observing the expansion displacement of a can after heat processing, the results of heat processing can be evaluated. Reliable differentiation can still be conducted even if there are colour changes in the cans. By using a long range type of sensor head, it is possible to control height of hoop materials such as steel plates and sheet materials even during transportation. The sensor head can be installed at a distance of up to 1000 mm. 6

Differentiation of different types of plastic components Reliable differentiation, even in highly variable small parts, using a high-precision sensor head. Even when the variety changes, external changeover of up to 4 patterns is possible by setting items in the bank function. Stacker counting & uneven checks The IL Series counts how many items are being transported along a conveyer, in addition to the noncontact detection of uneven stacking in the stacker. Reliable detection regardless of colour changes in the targets. Wire winding process Height controls of a PC board Prevents irregular winding by monitoring the traverser position. In addition, feedback control to the device is possible by measuring the volume wound into the bobbin at the same time. Controls the PC board height in the mounting and drilling processes. Various kinds of targets can be reliably controlled without being affected by the surface colours of the PC boards. Detection of stage inclination prior to furnace transportation Calculates the inclination by measuring multiple points on the stage prior to transferring to the furnace. Transferring the product after correcting the inclination allows for consistent temperature control. Wafer measurement inside an inspection machine Measures the behaviour of each wafer in the machine. Due to the small head size, the IL Series can be installed in compact spaces. This means the IL Series can be installed even after the machinery has been set up. Misalignment measurement and presence detection of a wafer/glass in a cassette. Measures the presence and protrusion of glass in a cassette. Stable detection is possible even if positional misalignments occur in the cassette itself by utilising analogue processing. Measuring the height of a chip after bonding Measures the height of the board pre-bonding and the chip postmounting, allowing control of the postprocessing suction nozzle and dispenser nozzle feedback. 7

Specification Sensor heads Model IL-030 IL-065 IL-100 IL-300 IL-600 Appearance Reference distance 30 mm 65 mm 100 mm 300 mm 600 mm Measurement range 20 to 45 mm 55 to 105 mm 75 to 130 mm 160 to 450 mm 200 to 1000 mm Red semiconductor laser, wavelength: 655 nm (visible light) Light source Laser class Class 1 (FDA (CDRH) Part1040.10) 1. Class 1 (IEC 60825-1) Class 2 (FDA (CDRH) Part1040.10) 1. Class 2 (IEC 60825-1) Output 220 µw 560 µw Spot diameter (at standard distance) Approx. 200 750 µm Approx. 550 1750µm Approx. 400 1350 µm Approx. ø0.5 mm Approx. ø1.6 mm Linearity 2. 3. ±0.1% of F.S. ±0.1% of F.S. ±0.15% of F.S. ±0.25% of F.S. ±0.25% of F.S.(200 to 600 mm) ±0.5% of F.S.(200 to 1000 mm) Repeatability 4. 2 µm 4 µm 10 µm 50 µm 300 µm Sampling rate 0.33/1/2/5 ms (4 levels available) Operation status indicators Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED Temperature characteristics 3. 0.05% of F.S./ C 0.06% of F.S./ C 0.06% of F.S./ C 0.08% of F.S./ C Enclosure rating IP67 Environmental resistance Ambient light 5. Incandescent lamp: 5000 lux Incandescent lamp: 7500 lux Incandescent lamp: 5000 lux Ambient temperature -10 to +50 C (No condensation or freezing) Relative humidity 35 to 85% RH (No condensation) Vibration 10 to 55 Hz Double amplitude 1.5 mm XYZ each axis: 2 hours Pollution degree 3 Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC Material Weight Approx. 60g Approx. 75g Approx. 135g 1. The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50. 2. Value when measuring the KEYENCE standard target (white diffuse object). 3. F.S. of each model is as follows. IL-030: ±5mm IL-065: ±10mm IL-100: ±20mm IL-300: ±140mm IL-600: ±400mm 4. Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 16. For the IL-300/IL-600, the sampling rate is 2 ms. 5. Value when the sampling rate is set to 2 ms or 5 ms. Amplifier unit Model IL-1000 IL-1500 IL-1050 IL-1550 Appearance Type DIN-rail mount Panel mount DIN-rail mount Panel mount Main unit/expansion unit Main unit Expansion unit Head compatibility Compatible Minimum IL-030: 1 µm, IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm displayable unit Display Display range IL-030/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable), IL-300/IL-600: ±999.99 mm to ±99 mm (3 levels selectable) Display rate Approx. 10 times/sec. Analogue voltage output 1. ±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω Analogue current output 1. 4 to 20 ma Maximum load resistance of 350 Ω None Bank switch input Control input 2. Zero-shift input Stop emission input Timing input Reset input Non-voltage input Judgement output Open collector output (NPN, PNP changeover possible/n.o., N.C. changeover possible) Control output 3. Alarm output Open collector output (NPN, PNP changeover possible/n.c.) Current Power voltage 4. 10 to 30 VDC ripple (P-P) 10% included, Class 2 Supplied by main unit Power consumption 2300 mw or less (at 30 V: 77 ma or less) 2500 mw or less (at 30 V: 84 ma or less) 2000 mw or less (at 30 V: 67 ma or less) 2200 mw or less (at 30 V: 74 ma or less) Ambient humidity -10 to +50 C (No condensation or freezing) Environmental Ambient temperature 35 to 85% RH (No condensation) resistance Vibration 10 to 55 Hz Double amplitude 1.5 mm XYZ each axis: 2 hours Pollution degree 2 Material Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC Weight (including attachments) Approx. 150g Approx. 170g Approx. 140g Approx. 160g 1. Select and use one of ±5 V, 1 to 5 V, 0 to 5 V or 4 to 20 ma. 2. Assign an input of your choice to the 4 external input lines before using. 3. The NPN open collector rated output is: 50 ma max./ch (20 ma when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit) The PNP open collector rated output is: 50 ma max./ch (20 ma/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit) 4. If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V. Sensor head cables (sold separately) The cable does not come attached with the sensor head and must be purchased separately. 1 cable included Appearance Cable length Model Weight 2 m OP-87056 Approx. 80 g 5 m OP-87057 Approx. 190 g 10 m OP-87058 Approx. 360 g 20 m OP-87059 Approx. 680 g This connector is required if the cable is cut. Connector used to connect to a display unit (2 pcs.) OP-84338 8

Communication unit Model DL-RB1A DL-RS1A Appearance Power supply voltage 20 to 30 VDC, including ripple, Ripple (P-P): 10% max. Class 2 (Supplied via connected sensor amplifier) Power consumption 27 ma max. 25 ma max. Number of connectable sensor amplifi ers Up to 8 units (including main unit) Indicator Alarm indicator lamp (red), Power indicator lamp (green) Communication indicator lamp (green 2), Alarm indicator lamp (red), Power indicator lamp (green) Communication method - Full duplex Synchronization method - Start-stop Transmission code - ASCII Baud rate - 2400/4800/9600/19200/38400 bps selectable (Factory-setting: 9600 bps) Data bit length - 8 bits/7 bits selectable (Factory-setting: 8 bits) Parity check - None/Even/Odd selectable (Factory-setting: None) Stop bit length - 1 bit Data delimiter - Data reception: automatically recognizes CR or CR+LF Data transmission: Fixed to CR+LF Ambient temperature -10 to +55 C Environment resistance Ambient humidity 35 to 85%RH (No condensation) Vibration resistance 10 to 55 Hz Double amplitude 1.5 mm XYZ each axis: 2 hours Material Case/Polycarbonate Weight Approx. 46 g Approx. 53 g Optional Type Appearance Model Description Weight End unit (Optional) OP-26751 To connect an additional expansion unit, use the end units to secure the display units on both ends. When connecting additional units, be sure to use the end units. (2 pcs.) Approx. 15g Panel front protection cover [Included in panel mount type amplifi er] Panel mounting bracket [Included in panel mount type amplifi er] OP-87076 OP-4122 The panel front protection cover and panel mounting bracket are included in the panel mount type amplifi er. If the supplied cover or bracket is lost or damaged, purchase a new one. Approx. 6g Approx. 7g Expansion cable: 300 mm OP-35361 Extension cable used for panel mount type amplifi er. Use this cable if the standard cable is not long enough. Approx. 10g DIN-rail mounting bracket OP-60412 The mounting bracket is used when the expansion cable is used to connect to the panel mount type display unit, in which case a DIN rail is not provided. Approx. 12g Wiring Diagram Brown 1. 10 to 30 VDC 4. Light blue 1. Blue 1. Black White Gray Green Orange 2. Shield 2. Pink 3. Yellow 3. Pink/purple 3. Purple 3. 0V HIGH judgment output LOW judgment output GO judgment output Alarm output Analogue output + Analogue output GND External input 1 (zero shift input) External input 2 (reset input) External input 3 (timing input) External input 4 (not used) 1. The brown, blue, and light blue cables are not provided in a IL-1050/IL-1550 unit (expansion unit). The power is supplied to the expansion unit from the IL-1000/ IL-1500 unit (main unit). 2. For an analogue output, OFF (not used), 0 to 5 V, ±5 V, 1 to 5 V, or 4 to 20 ma can be selected. 3. For an external input, bank A input, bank B input, laser emission stop input, or OFF (not used) can also be selected. For details, refer to the User s Manual. 4. If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V. 9

Dimensions Unit : mm Sensor heads IL-030 38.3 24.8 Center of received light Center of emitted light 22.6 9.5 9.1 9.1 13.7 3.6 0.6 48.5 Reference surface for distance detection 29.7 11.7 33.5 37.9 (min. 5) 3.2 42.1 2-ø3.5 (mounting hole) 3.2 ø9 (26) ø4.8 cable length 160 Tip M8 connector Indicator 9.4 9.5 Mounting bracket (supplied) Material: SUS304 t=2.0 Supplied screw (2 pcs.) M3, P=0.5, L=30 Material: SUS 20 60 12 4.8 6.6 13.8 6.5 3.5 2.5 2.5 3.5 30 18.3 11.7 ø3.5 4.8 3.5 42.1 55.2 Material: SUS304 t=1.5 6 2-M3 P=0.5 43.7 49.7 IL-065/100 23.2 42.3 Center of received light Center of emitted light 11.6 10.5 24.1 15.4 3.6 11.6 0.6 52.5 Reference surface for distance detection 34.7 11.7 38.5 42.8 (min. 5) 3.2 46.1 2-ø3.5 (mounting hole) 3.2 Indicator ø4.8 cable length 160 Tip M8 connector 9.4 9.5 Mounting bracket (supplied) Material: SUS304 t=2.0 Supplied screw (2 pcs.) M3, P=0.5, L=30 Material: SUS 20 62 4.8 6.5 12 3.5 3.5 5.5 6.7 15 4.8 3.5 31.3 22.1 11.7 4 ø3.5 46.1 57.2 Material: SUS304 t=1.5 6 2-M3 P=0.5 53.6 47.6 IL-300/600 Mounting bracket (supplied) 3.8 7.5 9.1 9.1 18.5 5.3 4.5 12 27.2 16.4 0.6 45 4.5 4.5 2-ø4.4 (mounting hole) 4.5 42 32.4 15.5 ø4.5 Material: SUS304 t=2.0 2 M4 P=0.7 55.8 Center of received light Center of emitted light 13.6 20.5 20.8 13 3.6 Reference surface for distance detection 66 57 (26) 15.5 50.7 (min. 5) ø4.8 cable length 160 Tip M8 connector ø9 Indicator 11.6 11.4 Material: SUS304 t=2.0 22 76 4.5 8 3.5 57 69.8 8 59.1 67.1 10

Options Unit : mm Amplifier unit (DIN-rail mount type) IL-1000/IL-1050 IL-1000 Cable diameter ø4.7 Cable length 2 m IL-1050 Cable diameter ø4.7 Cable length 2 m 18.5 28.3 8.9 18.5 28.3 8.9 Cable diameter ø4.8 (1.9) (3.4) Cable diameter ø4.8 3 135 MAX 3 135 MAX 17.4 42.4 37.4 When cover is open max.109.2 17.4 37.4 42.4 When cover is open max.109.2 17.6 17.6 (min.15) 20 21.6 35.4 (min.15) 20 21.6 35.4 76.3 (min.15) 76.3 (min.15) Amplifier unit (Panel mount type) IL-1500/IL-1550 4 44.7 15.3 Cable diameter ø4.7 Cable length 2 m 37.1 Cable diameter ø4.8 47.6 27.4 12.4 Panel thickness 1 to 6 X 45 +0.6-0 X=48 (number of amplifiers) -3 19.1 9.7 min.85 48 17.6 22.4 44.7 45 +0.6-0 76 19.1 9.7 45 +0.6-0 Communication unit (BCD output type) DL-RB1A DIN-rail mount 22.5 When the mounting bracket is attached OP-60412 (Optional) 53.4 53.4 (57.8) 37.1 60.9 37.1 34-pin MIL connector 21.1 35.4 70 31.4 15 70 2-ø3.4 2 - (4.4 3.4) 22.5 Communication unit (RS-232C communication type) DL-RS1A Material : SPCC Steel 15 28.5 35.5 DIN-rail mount 22.5 When the mounting bracket is attached OP-60412 (Optional) (48.2) 37.2 51.3 37.2 43.8 43.8 21.1 35.4 70 31.4 15 70 2-ø3.4 2 - (4.4 3.4) 22.5 15 Material : SPCC Steel 28.5 35.5 11

Total Solution Lineup CCD LASER MICROMETRE Multi-Purpose CCD Laser Micrometre IG Series Repeatability of 5 µm Linearity of ± 0.1% (IG-028) Built-in position monitor Feedback control using edge position control Outer diameter/deformation measurement CONTACT SENSOR High-precision Contact Digital Sensor GT2 Series High accuracy in the entire measurement range Good temperature characteristics No tracking errors Absolute position detection Resolution Accuracy 0.1 µm 1 µm Measurement of defects in a press fi t Detection of crank shaft defects INDUCTIVE DISPLACEMENT Digital Inductive Displacement Sensor EX-V Series Resolution of 0.02% of F.S. Linearity of ± 0.3% of F.S. Ultra high-speed sampling of 25 µs Confi rmation of the die closure of an IC molding press Measuring the gap between rollers Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved. IL-WW-C2-E 1021-1 E 600874 Printed in Japan * 6 0 0 8 7 4 *