Hearing Solutions. Feature Chart 4 Feature Summary 6 Tinnitus Feature Chart 14 Tinnitus Feature Summary 15. Feature Chart 20 Feature Summary 22

Similar documents
HEARING SOLUTIONS CATALOG 2013

2017 Product Portfolio

TH Premium IF 19. Technical Data. 60 db / 125 db SPL (ear simulator) 50 db / 113 db SPL (2 ccm coupler)

Product information PRIO 112 BTE VC PRIO 105 BTE DM VC PRIO 105 BTE DM. Hearing Instruments Functions: Personalization Functions:

TINNITUS TREATMENT SOLUTIONS

TINNITUS TREATMENT SOLUTIONS

TINNITUS TREATMENT SOLUTIONS

Tinnitus Treatment Solutions

XINO. Tinnitus TREATMENT Solution

Audibel A2 Tinnitus Tinnitus Treatment Solution. Tinnitus

Tinnitus. Treatment solutions for you and your loved ones

Tinnitus. treatment solutions for you and your loved ones

Tinnitus. Technology products for you and your loved ones

Tinnitus. Technology products for you and your loved ones

Tinnitus. Technology products for you and your loved ones

TINNITUS. Technology products for you and your loved ones

TINNITUS. Technology products for you and your loved ones

Tinnitus. Technology products for you and your loved ones

rega ITE audifon GmbH & Co. KG Werner-von-Siemens-Straße 2 D Kölleda Tel Fax

Tinnitus. Treatment for Professionals

P r o d u c t I n f o R M A T I O N - X W / W / V

Tinnitus. Technology products for you and your loved ones

Tinnitus Technology products for you and your loved ones

Tinnitus. Technology products for you and your loved ones

Solutions for better hearing. audifon innovative, creative, inspired

çıkış çıkış MPO Düşük frekansta maksimum çıkış MPO Düşük frekansta maksimum çıkış

Using the BHM binaural head microphone

Hearing Aids for Tinnitus Patients: It s Not Just About Speech. Steve Benton, Au.D. VA Medical Center Decatur, GA

Tinnitus. Advanced technology products

QuickTIPS REMOTE CONTROL TRULINK FOR ANDROID DEVICES VOLUME CHANGES MEMORY CHANGES. PRODUCT AVAILABILITY: Halo iq, Halo 2, and Halo Devices

Beltone Tinnitus Calmer Reference Guide

Ear-level instrumentation in the treatment of tinnitus

Sound generators for the relief and management of tinnitus and hyperacusis

5/8/2013. Tinnitus Population. The Neuromonics Sanctuary. relief. 50 Million individuals suffer from tinnitus

Radio for Everyone...

Datasheet. Dual-Band airmax ac Radio with Dedicated Wi-Fi Management. Model: B-DB-AC. airmax ac Technology for 300+ Mbps Throughput at 5 GHz

4 MHz Lock-In Amplifier

ex 800 Series ematrix System

Digital Drive-Thru Communication System

A unique base plate in solid copper weighing 2.4kg is what guarantees a completely controlled thermal management.

StepArray+ Self-powered digitally steerable column loudspeakers

Stereo Box Pre Box Amp Box Amp Box Mono Switch Box. Tuner Box Dock Box F / V Phono Box MM Record Box USB Phono Box II

2 MHz Lock-In Amplifier

SCM820 Digital IntelliMix Automatic Mixer SEAMLESS MIXING. ADVANCED CONTROL.

3500 ANSI Lumens Full HD 1080p DLP Projector for Home Entertainment

Time For Change GS-HL-005. Single Unit Commentary. Key Points. Single Unit Commentary. Glensound. COIN GT-013 Glensound Commentary Telex Intercom

Digital audio is superior to its analog audio counterpart in a number of ways:

DOD OWNER'S MANUAL 866 SERIES II GATED COMPRESSOR/LIMITER SIGNAL PROCESSORS

Summary Table Voluntary Product Accessibility Template. Supporting Features. Supports. Supports. Supports. Supports

Neo DynaMaster Full-Featured, Multi-Purpose Stereo Dual Dynamics Processor. Neo DynaMaster. Full-Featured, Multi-Purpose Stereo Dual Dynamics

Generating the Noise Field for Ambient Noise Rejection Tests Application Note

SPL Analog Code Plug-in Manual

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Therefore, HDCVI is an optimal solution for megapixel high definition application, featuring non-latent long-distance transmission at lower cost.

FL6900U 1080p HD Projector

SPL Analog Code Plug-ins Manual Classic & Dual-Band De-Essers

QC External Synchronization (SYN) S32

sound generators for the relief and management of tinnitus and hyperacusis

3,600 ANSI Lumen SVGA DLP Projector with Dual HDMI inputs and USB type-a power supply

MOBILE AUDIO PRODUCT SUMMARY 2018

SMART Board Interactive Whiteboard System

The basic concept of the VSC-2 hardware

Impressive Image Performance for Presentations

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

Overview. Dimensions and weights 1. Specifications SMART Board 7086 interactive display Model SBID-7086

Design Brief - I35 and I35 DAC Stereo Integrated Amplifier

Getting Started with the LabVIEW Sound and Vibration Toolkit

3,500 Lumens XGA Business Projector

SMART Board interactive whiteboard system Model SBX880i4

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

KS8500 Curved SUHD TV

AcoustiSoft RPlusD ver

LX20 OPERATORS MANUAL

WiPry 5x User Manual. 2.4 & 5 GHz Wireless Troubleshooting Dual Band Spectrum Analyzer

WIDEX FITTING GUIDE PROGRAMMING ZEN FOR WIDEX ZEN THERAPY COMPASS GPS INTRODUCTION BASIC WIDEX ZEN THERAPY FITTING STEPS FOR THE BASIC FITTING

3M Littmann TeleSteth System. Tele-Auscultation. Hear It. As If You Were There.

Tinnitus: How an Audiologist Can Help

Omnia.9sg Your Processor s Secret Weapon

WiPry User Manual. 2.4 GHz Wireless Troubleshooting

Getting Started Guide for the V Series

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

D-76 DIGITAL AUDIO CONSOLE

What are you talking about...

PLV-Z2 ROLL THE FILM FOR THE FUTURE!

Voluntary Product Accessibility Template

What is the minimum sound pressure level iphone or ipad can measure? What is the maximum sound pressure level iphone or ipad can measure?

Chapter 1. Introduction to Digital Signal Processing

VSX Series Getting Started Guide

3G/HD/SD dual channel audio embedder/de-embedder

Hugo Technology. An introduction into Rob Watts' technology

5000 ANSI Lumens High Brightness XGA Installation Projector

MachineryMate 800 operating guide Handheld vibration meter

OVERVIEW. YAMAHA Electronics Corp., USA 6660 Orangethorpe Avenue

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

Voluntary Product Accessibility Template (VPAT)

PROFESSIONAL D-ILA PROJECTOR DLA-G11

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

S1 Digital/Analogue Radio Broadcast Mixer September 2009

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

PROFESSIONAL D-ILA PROJECTOR DLA-G11

Transcription:

HEARING SOLUTIONS catalog 13

Hearing Solutions AGX s3s Feature Chart 4 Feature Summary 6 Tinnitus Feature Chart 14 Tinnitus Feature Summary 15 AGX swi Feature Chart Feature Summary 22 AGX ssl Feature Summary AGX sto / AGX sig 34 SurfLink Feature Summary 44

2 PATIENT DRIVEN PERFORMANCE TESTED

AGX s3s Our AGX s3s lineup includes a newly styled micro RIC 312, RIC 312, mini BTE 312, BTE 13 and a tinnitus RIC. All five feature everything you and your patients love about our popular wireless hearing aids along with a new, more tactile control switch, updated compression strategy, new, patientrequested color options and much more. AGX swi AGX s3s Feature Chart 4 AGX s3s Feature Summary 6 AGX s3s micro RIC 312 8 AGX s3s micro RIC 312 AP 9 AGX ssl DEEP CANAL INSTRUMENTS AGX s3s RIC 312 AGX s3s RIC 312 AP 11 AGX s3s mini BTE 312 12 AGX s3s BTE 13 13 AGX s3s Tinnitus Feature Chart 14 AGX sto /AGX sig AGX s3s Tinnitus Feature Summary 15 AGX s3s Tinnitus RIC 16 AGX s3s Tinnitus RIC AP 17 SURFLINK Accessories 3

AGX s3s AGX swi W I R E L E S S Sound Imaging Binaural Spatial Mapping Machine Noise Wind Directionality Synchronized User Controls Binaural Telephone Mode Volume Memory SurfLink Accessory Compatibility SurfLink Mobile SurfLink Programmer VIBRANT Optimal high-resolution sound imaging with frequency shaping in all 16 channels and 16 bands Premium Ear-to-Ear Processing SurfLink Media SurfLink Remote iq Boost PureWave Feedback Eliminator AGX ssl DEEP CANAL INSTRUMENTS AGX s3s FEATURE CHART Acoustic Scene Analyzer Voice iq 2 Noise Reduction Strength AudioScapes Machine Noise Premium 16-channel environmental adaptation with 5 levels of personalization Maximum (db) Speech in Noise Wind Quiet Speech Noise AGX sto /AGX sig AudioScape Adaptation Levels 5 Spectral iq SoundPoint Self Learning Swap Fit 3D Speech Mapping SURFLINK Accessories All AGX s3s Models Include: Ergonomic Switch to Adjust Volume and Memory ISO Compression Strategy SnapFit Receivers (for RIC products) InVision Directionality Automatic Telephone Solutions Live Speech Mapping Advanced Memories (Music, TV, Relax, T-Coil, Binaural Processing Off) T 2 On Demand Programming 4

ACTIVE High-resolution sound imaging with frequency shaping in 12 channels and 12 bands SOCIAL Frequency shaping in 8 channels and 8 bands Advanced Ear-to-Ear Processing Advanced 12-channel environmental adaptation with 3 levels of personalization Select 8-channel environmental adaptation with 2 levels of personalization Moderate (8dB) Light (6dB) 3 on/off In-Situ Audiometry Auto Path Verify Comfort Data Logging 4 Memories HydraShield 2 * Wireless accessories and features are not available in AGX s3s,, and. 5

AGX s3s Feature Summary AGX s3s products are available with and without wireless capabilities. AGX s3s product names contain an i to signify wireless technology i, i and i. IRIS Technology leverages a unique ear-to-ear communication protocol. Binaural Spatial Mapping* applies the combined speed and power of multiple dual-core platforms to achieve parallel processing benefits. This innovative protocol queries, analyzes, and maps the acoustic space surrounding the patient, applying the appropriate signal processing strategy for directionality and noise management. Voice iq 2 nearly doubles the noise reduction capability of our leading noise reduction and speech preservation system while still maintaining speech. Voice iq 2 : Instantly applies variable noise adaptation in all channels between each pause Has been proven to reduce listening effort and cognitive fatigue when used in tandem with InVision Directionality** Provides up to db of noise reduction JustTalk,* a mode on our new SurfLink Mobile, enables true hands-free phone conversations by turning the wearer s AGX s3s hearing aids into both the cell phone microphone and receiver. A new control switch gives users a simple, tactile way to control volume and change memories. Users will enjoy more dynamic and personalized sound with AGX s3s new ISO Compression. The 312 RICs features SnapFit receivers, which offer easier receiver connection and ensure greater stability. Unlike competing technologies that apply frequency compression broadly, our frequency lowering technology, Spectral iq, is designed to enhance real-time audibility by intelligently identifying high-frequency speech cues, then replicating them in lower frequencies. This allows AGX s3s to maintain important frequency relationships, retaining the sound quality that comes from harmonic distribution, while providing audibility for high-frequency speech cues for patients that may have previously been considered unaidable. Thanks to Self Learning, AGX s3s gradually and automatically learns patient volume control preferences in each active memory, which helps reduce the number of manual volume adjustments patients need to make. *Features only available when hearing aids are ordered with wireless functionality. ** Sarampalis, A., Kalluri, S., Edwards, B., Hafter, E. (09, October). Objective measures of listening effort: Effects of background noise and noise reduction. Journal of Speech, Language, and Hearing Research, 52, 12-12. 6

Activated via SurfLink Remote, our iq Boost* feature allows patients to enable aggressive noise reduction while optimizing sound quality in extremely noisy situations. AGX s3s wouldn t be an AGX product without our PureWave Feedback Eliminator. This leading technology ensures wide fitting ranges and a fast response to more complex feedback. HydraShield 2 Omniphobic nano-coating provides unprecedented resistance against wax, oils and everyday moisture. Our Swap Fit fitting function allows you to transfer patient settings from their current AGX product to a new one enabling more time for fine-tuning and counseling. With Synchronized User Adjustments* patients can use a single hearing instrument to adjust volume or memory for the pair eliminating the need to manually change two instruments. Binaural Telephone Mode* places the phone-side hearing aid in Automatic Telephone Response or Telecoil mode while attenuating the off-side hearing aid. InVision Directionality in AGX s3s hearing aids together with Voice iq 2, our leading directional system is designed to enhance speech audibility, even in complex listening environments. Voice Indicators alert your patients to the status of their hearing aid, low battery, memory and telephone modes in their choice of male or female voices in a wide variety of languages. Automatic Telephone Solutions (ATS) automatically detects telephone use and adjusts to the optimal acoustic frequency response for telephone listening. Bring the benefits of telehealth to your practice with our On Demand options. Each one is designed to elevate your interaction with patients and provide a better way for you to deliver care. Includes T 2 On Demand, Audiology On Demand and innovative applications that work with the ipad, iphone and ipod Touch. ipad, iphone and ipod Touch are registered trademarks of Apple Inc. Color Guide Standard Colors Champagne Sterling Bronze Slate Espresso Black Bright Colors Blue Ice Fuchsia Fabulous Blue Pacific Red Hot Pink Pixie Purple Pop 7

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) AGX s3s micro RIC 312 RECEIVER-IN-CANAL Matrices: 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA 0 2 0 1K 2K 4K 8K Measurement Gain Data Gain Data 2cc 2cc Peak OSPL (db SPL) 115 125 1 HFA OSPL (db SPL) 9 115 RTF OSPL (db SPL) 116 125 AGX s3s micro RIC 312 (gray), and AGX s3s micro RIC 312 (black). Peak Gain (db) 62 71 HFA Full-On Gain (db) 44 54 RTF Full-On Gain (db) 53 62 Wireless RIC312 115/ Stock Frequency Range (Hz) -70-70 - 70-70 OSPL 55 FOG 115 Reference Test Frequency (khz) 1.6 1.6 45 5 HFA Frequencies (khz) 35 95 Reference Test Gain (db) 32 41 38 25 85 15 75 Harmonic Distortion 0 00 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s micro RIC 312 at 115/. Induction Coil Sensitivity Hz (%) <3 <3 <3 <3 HFA SPLITS (ANSI) (db SPL) OSPL FOG 1 MASL (IEC) (db SPL) Battery Current (ma) 1.7 1.7 2.0 2.0 0 00 Idle Current (ma) 1.3 1.3 1.4 1.4 Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 5-7* 5-7* 4-6* 4-6* OSPL (gray) and Full-On Gain (black) curves for the AGX s3s micro RIC 312 at /. * Results for wireless products will vary based on wireless usage. 8

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 AGX s3s RIC 312 AP RECEIVER-IN-CANAL ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 131 1 137 Peak OSPL (db SPL) 116 125 HFA OSPL (db SPL) 124 132 RTF OSPL (db SPL) 0 2 0 1K 2K 4K 8K 67 78 Peak Gain (db) 54 64 HFA Full-On Gain (db) 61 72 RTF Full-On Gain (db) AGX s3s micro RIC 312 AP (gray), AGX s3s micro RIC 312 AP (black) fitting ranges. - - - - Frequency Range (Hz) 1.6 1.6 Reference Test Frequency (khz) OSPL FOG 1 HFA Frequencies (khz) 39 51 48 61 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s micro RIC 312 AP at 123/. Wireless RIC312 1/ AP MASL (IEC) (db SPL) OSPL FOG 1 1.4 1.4 1.7 1.7 Battery Current (ma) 1.3 1.3 1.4 1.4 Idle Current (ma) 1 Estimated Battery Life for 16-Hour Day 6-8* 6-8* 4-6* 4-6* 312 Zinc Air (days) 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s micro RIC 312 AP at 1/. * Results for wireless products will vary based on wireless usage. 9

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) RIC 312 RECEIVER-IN-CANAL Matrices: 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA Gain Data Gain Data 0 Measurement 2cc 2cc Peak OSPL (db SPL) 115 125 1 HFA OSPL (db SPL) 9 115 RTF OSPL (db SPL) 116 125 2 0 1K 2K 4K 8K AGX s3s RIC 312 (gray) and AGX s3s RIC 312 (black). Peak Gain (db) 62 71 HFA Full-On Gain (db) 44 54 RTF Full-On Gain (db) 53 62 Frequency Range (Hz) -70-70 -70-70 OSPL FOG 1 Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 32 41 38 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s RIC 312 at 115/. Harmonic Distortion 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Induction Coil Sensitivity OSPL FOG HFA SPLITS (ANSI) (db SPL) 86 93 1 MASL (IEC) (db SPL) 91 Battery Current (ma) 1.7* 1.7* 2.0* 2.0* Idle Current (ma) 1.3* 1.3* 1.4* 1.4* 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s RIC 312 at /. Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 5-7* 5-7* 4-7* 4-7* * Results for wireless products will vary based on wireless usage.

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 RIC 312 AP RECEIVER-IN-CANAL ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 131 1 137 Peak OSPL (db SPL) 116 125 HFA OSPL (db SPL) 126 136 RTF OSPL (db SPL) 67 78 Peak Gain (db) 0 2 0 1K 2K 4K 8K 53 64 HFA Full-On Gain (db) 64 75 RTF Full-On Gain (db) AGX s3s RIC 312 AP (gray), AGX s3s RIC 312 AP (black) fitting ranges. - - - - 4 Frequency Range (Hz) OSPL FOG 1.6 1.6 Reference Test Frequency (khz) 1 NA HFA Frequencies (khz) 39 51 48 61 Reference Test Gain (db) Harmonic Distortion 0 00 <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) OSPL (gray) and Full-On Gain (black) curves for the AGX s3s RIC 312 AP at 123/. <3 <3 <3 <3 Hz (%) Induction Coil Sensitivity OSPL FOG 1 95 2 HFA SPLITS (ANSI) (db SPL) 1 93 4 MASL (IEC) (db SPL) 1.2* 1.2* 1.4* 1.4* Battery Current (ma) 1.1* 1.1* 1.2* 1.2* Idle Current (ma) 0 00 Estimated Battery Life for 16-Hour Day 6-8* 6-8* 4-6* 4-6* 312 Zinc Air (days) OSPL (gray) and Full-On Gain (black) curves for the AGX s3s RIC 312 AP at 1/. * Results for wireless products will vary based on wireless usage. 11

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) mini BTE 312 BEHIND-THE-EAR Matrix: 126/65 Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA Earhook Thin Tube (Size 3+, Occluded) 0 Measurement 2cc 2cc Peak OSPL (db SPL) 126 131 124 HFA OSPL (db SPL) 118 8 RTF OSPL (db SPL) 1 112 2 0 1K 2K 4K 8K Peak Gain (db) 65 64 68 AGX s3s mini BTE 312 fitting range. HFA Full-On Gain (db) 52 RTF Full-On Gain (db) 69 57 Frequency Range (Hz) - 70-70 - 70-70 OSPL FOG 85 75 135 125 Reference Test Frequency (khz) 1.6 1.6 65 55 115 5 HFA Frequencies (khz) 45 95 35 85 Reference Test Gain (db) 41 53 31 37 25 75 15 65 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s mini BTE 312 with Earhook. Harmonic Distortion 0 Hz (%) <5 <5 <2 <2 0 Hz (%) <3 <3 <1 <1 Hz (%) <3 <3 <2 <2 OSPL FOG Induction Coil Sensitivity 85 1 75 HFA SPLITS (ANSI) (db SPL) 97 87 65 55 MASL (IEC) (db SPL) 92 86 45 35 Battery Current (ma) 1.3* 1.3* 1.3* 1.3* 25 15 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s mini BTE 312 with Thin Tube. Idle Current (ma) 1.2* 1.2* 1.2* 1.2* Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 9-11* 9-11* 9-11* 9-11* * Results for wireless products will vary based on wireless usage. 12

FOG OSPL (db) (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) MATRIX: 126/65 Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 13 BTE 13 BEHIND-THE-EAR DATA Earhook Thin Tube (Size 3+, Occluded) 2cc 2cc Measurement 0 126 131 121 124 Peak OSPL (db SPL) 119 8 HFA OSPL (db SPL) 1 112 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 65 63 68 Peak Gain (db) 59 52 HFA Full-On Gain (db) AGX s3s BTE 13 fitting range. 57 RTF Full-On Gain (db) -70-70 -70-70 Frequency Range (Hz) OSPL FOG 1.6 1.6 Reference Test Frequency (khz) 85 75 135 125 65 115 1.0,1.6, 1.0,1.6, HFA Frequencies (khz) 55 5 45 95 42 55 31 37 Reference Test Gain (db) 35 85 25 75 Harmonic Distortion 15 0 00 65 <5 <4 <2 <2 0 Hz (%) <3 <4 <1 <1 0 Hz (%) OSPL (gray) and Full-On Gain (black) curves for the AGX s3s BTE 13 with Earhook. <3 <3 <2 <2 Hz (%) Induction Coil Sensitivity OSPL FOG 85 1 2 87 HFA SPLITS (ANSI) (db SPL) 75 86 MASL (IEC) (db SPL) 65 55 1.7* 1.7* 1.7* 1.7* Battery Current (ma) 45 35 25 1.3* 1.3* 1.3* 1.3* Idle Current (ma) 15 0 00 Estimated Battery Life for 16-Hour Day 9-11* 9-11* 9-11* 9-11* 13 Zinc Air (days) OSPL (gray) and Full-On Gain (black) curves for the AGX s3s BTE 13 with Thin Tube. * Results for wireless products will vary based on wireless usage. 13

FEATURE CHART Sound Imaging Optimal high-resolution sound imaging with frequency shaping in all 12 channels and 12 bands PureWave Feedback Eliminator Acoustic Scene Analyzer Premium 12-channel environmental adaptation with 3 levels of personalization Voice iq 2 Noise Reduction Strength Moderate (8dB) AudioScapes Machine Noise Speech in Noise Wind Quiet Speech Noise AudioScape Adaptation Levels 3 SoundPoint Self Learning Swap Fit 3D Speech Mapping 14

AGX s3s Tinnitus AGX s3s Tinnitus AGX s3s Tinnitus is a new solution designed to help provide relief to the million Americans affected by tinnitus. Using our patent-pending Multiflex Tinnitus Technology, AGX s3s Tinnitus enables hearing professionals to customize a sound stimulus designed to relieve each patient s unique symptoms, making it the most flexible and personalized way to treat tinnitus. Tinnitus Therapy + Hearing Aid = Two Devices in One o Configured memories (tinnitus, tinnitus + hearing aid, hearing aid) Flexible adjustments in 16 bands o Amplification operates independently of tinnitus stimulus Ability to adjust modulation rate of stimulus o Stimulus is a white noise, amplitude and frequency modulation is available and is configurable via 12 bands Compatible with both tinnitus retraining therapy and masking protocols Personalized adjustments during fitting made by patient using SoundPoint Tinnitus Flexible device-level control Nearly invisible device RIC Color Guide Standard Colors Champagne Sterling Bronze Slate Pearl Onyx 15

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) AGX s3s TINNITUS RECEIVER-IN-CANAL MATRICES: /, 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: DATA Gain Data Gain Data Gain Data Measurement 2cc 2cc 2cc Peak OSPL (db SPL) 122 115 126 1 HFA OSPL (db SPL) 2 8 112 RTF OSPL (db SPL) 116 118 AGX s3s Tinnitus (gray), AGX s3s Tinnitus (dark gray), AGX s3s Tinnitus (black) fitting ranges. Peak Gain (db) 51 61 HFA Full-On Gain (db) 31 44 51 OSPL FOG RTF Full-On Gain (db) 39 51 57 Frequency Range (Hz) - 70-70 - 70-70 - - 70 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s Tinnitus at /. Reference Test Frequency (khz) HFA Frequencies (khz) 1.6 1.6 1.6 Reference Test Gain (db) 25 32 31 41 35 43 Harmonic Distortion 0 Hz (%) <3 <3 <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 <3 <3 OSPL FOG Hz (%) <3 <3 <3 <3 <3 <3 Attack and Release Time () Test Mode Attack Time (ms) 15 15 15 15 15 15 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 5-1 5-2 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s Tinnitus at 115/. OSPL FOG 1 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 84 88 95 MASL (IEC) (db SPL) 72 81 89 Battery Current (ma) 1.2 1.2 1.4 1.3 1.6 1.4 Idle Current (ma) 1.1 1.1 1.2 1.2 1.2 1.2 Estimated Battery Life for 16-Hour Day Zinc Air (days) 5-8 5-6 5-8 5-8 4-6 4-6 Tinnitus Therapy Stimulus 16 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s Tinnitus at /. Max RMS Output (db SPL) 87 87 87 Weighted RMS Output Level (db SPL) 87 87 87 Max 1/3 Octave Output (db SPL) 87 87 87

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) MATRICES: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: AGX s3s TINNITUS AP RECEIVER-IN-CANAL RECEIVER-IN-CANAL ABSOLUTE POWER ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 1 1 137 Peak OSPL (db SPL) 115 124 HFA OSPL (db SPL) 127 135 RTF OSPL (db SPL) 69 Peak Gain (db) 52 65 HFA Full-On Gain (db) 63 75 RTF Full-On Gain (db) - - - 00-40 Frequency Range (Hz) 0 2 0 1K 2K 4K 8K AGX s3s Tinnitus AP (gray), AGX s3s Tinnitus AP (black) fitting ranges. 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 1 38 52 47 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) 0 00 Attack and Release Time () Test Mode 15 15 15 15 Attack Time (ms) OSPL (gray) and Full-On Gain (black) curves for the AGX s3s Tinnitus AP at 123/. 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) OSPL FOG Induction Coil Sensitivity 98 5 HFA SPLITS (ANSI) (db SPL) 1 1 95 8 MASL (IEC) (db SPL) 1.2 1.2 1.6 1.4 Battery Current (ma) 1.1 1.1 1.2 1.2 Idle Current (ma) Estimated Battery Life for 16-Hour Day 5-8 5-8 4-6 4-6 Zinc Air (days) Tinnitus Therapy Stimulus 87 87 Max RMS Output (db SPL) 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX s3s Tinnitus AP at 1/. 87 87 Weighted RMS Output Level (db SPL) 87 87 Max 1/3 Octave Output (db SPL) 17

18 THERE is MORE TO OUR WIRELESS

AGX s3s The success of Starkey s AGX swi wireless hearing aids in the marketplace proves that simplicity and clarity win every time. From the ease of true wireless programming to the quality of their sound to the convenience of our compatible SurfLink accessories, AGX swi wireless hearing aids help make listening effortless again. AGX swi Feature Chart AGX swi AGX ssl DEEP CANAL INSTRUMENTS AGX swi Feature Summary 22 ITE 24 HS 25 ITC 26 CIC 27 AGX sto /AGX sig SURFLINK Accessories 19

AGX s3s Sound Imaging Binaural Spatial Mapping VIBRANT Optimal high-resolution sound imaging with frequency shaping in all 16 channels and 16 bands Premium Ear-to-Ear Processing AGX swi W I R E L E S S Machine Noise Wind Directionality Synchronized User Controls Binaural Telephone Mode Volume Memory SurfLink Accessory Compatibility SurfLink Mobile SurfLink Programmer SurfLink Media SurfLink Remote iq Boost PureWave Feedback Eliminator AGX ssl DEEP CANAL INSTRUMENTS AGX swi FEATURE CHART Acoustic Scene Analyzer Voice iq 2 Noise Reduction Strength AudioScapes Premium 16-channel environmental adaptation with 5 levels of personalization Maximum (db) Machine Noise Speech in Noise Wind Quiet Speech AGX sto /AGX sig Noise AudioScape Adaptation Levels 5 Spectral iq SoundPoint Self Learning Swap Fit 3D Speech Mapping SURFLINK Accessories All AGX swi Models Include: InVision Directionality ( on CICs) Automatic Telephone Solutions Live Speech Mapping Advanced Memories (Music, TV, Relax, T-Coil, Binaural Processing Off) Indicators (Level-Dependent Speech, Level-Dependent Tone) T 2 On Demand Programming Self Check

ACTIVE SOCIAL High-resolution sound imaging with frequency shaping in 12 channels and 12 bands Frequency shaping in 8 channels and 8 bands Advanced Ear-to-Ear Processing Advanced 12-channel environmental adaptation with 3 levels of personalization Select 8-channel environmental adaptation with 2 levels of personalization Moderate (8dB) Light (6dB) 3 on/off In-Situ Audiometry Auto Path Verify Comfort Data Logging 4 Memories 21

AGX swi Feature Summary IRIS Technology leverages a unique ear-to-ear communication protocol. Binaural Spatial Mapping applies the combined speed and power of multiple dual-core platforms to achieve parallel processing benefits. This innovative protocol queries, analyzes, and maps the acoustic space surrounding the patient, applying the appropriate signal processing strategy for directionality and noise management. Voice iq 2 nearly doubles the noise reduction capability of our leading noise reduction and speech preservation system while still maintaining speech. Voice iq 2 : Instantly applies variable noise adaptation in all channels between each pause Has been proven to reduce listening effort and cognitive fatigue when used in tandem with InVision Directionality* Provides up to db of noise reduction Unlike competing technologies that apply frequency compression broadly, our frequency lowering technology, Spectral iq, is designed to enhance real-time audibility by intelligently identifying high-frequency speech cues, then replicating them in lower frequencies. This allows AGX swi to maintain important frequency relationships, retaining the sound quality that comes from harmonic distribution, while providing audibility for high-frequency speech cues for patients that may have previously been considered unaidable. Activated via SurfLink Remote, our iq Boost feature allows patients to enable aggressive noise reduction while optimizing sound quality in extremely noisy situations. Thanks to Self Learning, AGX swi gradually and automatically learns patient volume control preferences in each active memory, which helps reduce the number of manual volume control adjustments patients need to make. AGX swi wouldn t be an AGX product without our PureWave Feedback Eliminator. This leading technology ensures wide fitting ranges and a fast response to more complex feedback. Our Swap Fit fitting function allows you to transfer patient settings from their current AGX product to a new one enabling more time for fine-tuning and counseling. * Sarampalis, A., Kalluri, S., Edwards, B., Hafter, E. (09, October). Objective measures of listening effort: Effects of background noise and noise reduction. Journal of Speech, Language, and Hearing Research, 52, 12-12. 22

With Synchronized User Adjustments patients can use a single hearing instrument to adjust volume or memory for the pair eliminating the need to manually change two instruments. Binaural Telephone Mode places the phone-side hearing aid in Automatic Telephone Response or Telecoil mode while attenuating the off-side hearing aid. InVision Directionality in AGX swi hearing aids together with Voice iq 2, our leading directional system is designed to enhance speech audibility, even in complex listening environments. Voice Indicators alert your patients to the status of their hearing aid, low battery, memory and telephone modes in their choice of male or female voices in a wide variety of languages. Automatic Telephone Solutions (ATS) automatically detects telephone use and adjusts to the optimal acoustic frequency response for telephone listening. Bring the benefits of telehealth to your practice with our On Demand options. Each one is designed to elevate your interaction with patients and provide a better way for you to deliver care. Includes T 2 On Demand, Audiology On Demand and innovative applications that work with the ipad, iphone and ipod Touch. 23

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) ITE IN-THE-EAR Matrices: 115/, 123/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 13 DATA 0 2 0 1K 2K 4K 8K Measurement ITE 115/ ITE 123/ 2cc 2cc Peak OSPL (db SPL) 115 124 123 1 HFA OSPL (db SPL) 116 RTF OSPL (db SPL) 116 128 Peak Gain (db) 58 68 AGX swi ITE fitting range. HFA Full-On Gain (db) 46 53 RTF Full-On Gain (db) 54 66 Frequency Range (Hz) - 60-00 - 00-5 OSPL FOG Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 33 41 39 53 Harmonic Distortion 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX swi ITE at 115/. Attack and Release Time () Test Mode 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Attack Time (ms) OSPL FOG 1 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 95 1 MASL (IEC) (db SPL) 83 95 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX swi ITE at 123/. Battery Current (ma) 1.22 1.22 1.22 1.22 Idle Current (ma) 1.14 1.15 1.13 1.13 Estimated Battery Life for 16-Hour Day 13 Zinc Air (days) 12-16* 12-16* 12-16* 12-16* * Results for wireless products will vary based on wireless usage. 24

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 HS HALF-SHELL DATA HS / HS 115/ 0 2cc 2cc Measurement 119 115 124 Peak OSPL (db SPL) 5 9 HFA OSPL (db SPL) 111 116 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 49 58 Peak Gain (db) 36 46 HFA Full-On Gain (db) AGX swi HS fitting range. 43 53 RTF Full-On Gain (db) - 00-70 - 60-60 Frequency Range (Hz) 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 28 36 32 41 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX swi HS at /. Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) OSPL FOG 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity 89 94 HFA SPLITS (ANSI) (db SPL) 71 82 MASL (IEC) (db SPL) 1.22 1.22 1.22 1.22 Battery Current (ma) 1.15 1.15 1.15 1.15 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX swi HS at 115/. 8-9* 8-9* 8-9* 8-9* 312 Zinc Air (days) * Results for wireless products will vary based on wireless usage. 25

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) ITC IN-THE-CANAL Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA 0 ITC / ITC 115/ Measurement 2cc 2cc 2 0 1K 2K 4K 8K Peak OSPL (db SPL) 119 115 124 HFA OSPL (db SPL) 5 9 RTF OSPL (db SPL) 111 116 Peak Gain (db) 49 58 AGX swi ITC fitting range. HFA Full-On Gain (db) 36 46 RTF Full-On Gain (db) 43 53 Frequency Range (Hz) - 00-70 - 60-60 OSPL FOG Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 28 36 32 41 Harmonic Distortion 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX swi ITC at /. Attack and Release Time () Test Mode 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Attack Time (ms) OSPL FOG Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 89 94 MASL (IEC) (db SPL) 71 82 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX swi ITC at 115/. Battery Current (ma) 1.22 1.22 1.22 1.22 Idle Current (ma) 1.15 1.15 1.15 1.15 Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 8-9* 8-9* 8-9* 8-9* * Results for wireless products will vary based on wireless usage. 26

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: CIC COMPLETELY-IN-CANAL DATA CIC / CIC 115/ 0 2cc 2cc Measurement 119 115 124 Peak OSPL (db SPL) 4 HFA OSPL (db SPL) 115 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 49 58 Peak Gain (db) 35 46 HFA Full-On Gain (db) AGX swi CIC fitting range. 43 54 RTF Full-On Gain (db) - 70-70 - 70-70 Frequency Range (Hz) 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 28 35 32 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX swi CIC at /. Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) OSPL FOG 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) MASL (IEC) (db SPL) 1.17 1.17 1.17 1.17 Battery Current (ma) 1.12 1.12 1.13 1.13 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX swi CIC at 115/. 4-6* 4-6* 4-6* 4-6* Zinc Air (days) * Results for wireless products will vary based on wireless usage. 27

THE ORIGINAL IIC 28

AGX s3s Imitated but never duplicated, our AGX ssl isn t just the world s first ever custom-fit invisible-in-the-canal (IIC) hearing aid it s also the most popular. Invisible solutions are a proven draw for new patients. Now available in three technology levels, AGX ssl gives you and your patients more options to choose from than ever before. When it comes to invisible custom hearing aids, AGX ssl is the benchmark by which all other IICs are judged. AGX ssl Feature Summary AGX swi AGX ssl DEEP CANAL INSTRUMENTS AGX ssl 31 AGX sto /AGX sig SURFLINK Accessories 29

AGX s3s AGX swi AGX ssl Feature Summary Voice iq 2 nearly doubles the noise reduction capability of our leading noise reduction and speech preservation system while still maintaining speech. Voice iq 2 : Instantly applies variable noise adaptation in all channels between each pause Provides up to db of noise reduction Unlike competing technologies that apply frequency compression broadly, our frequency audibility technology, Spectral iq, is designed to enhance real-time audibility by intelligently identifying high-frequency speech cues, then replicating them in lower frequencies. This allows AGX ssl to maintain important frequency relationships, retaining the sound quality that comes from harmonic distribution, while providing audibility for high-frequency speech cues for patients that may have previously been considered unaidable. AGXssl SURFLINK AGX sto /AGX sig AGX ssl Accessories DEEP CANAL INSTRUMENTS AGX ssl wouldn t be an AGX product without our PureWave Feedback Eliminator. This leading technology ensures wide fitting ranges and a fast response to more complex feedback. Voice Indicators alert your patients to the status of their hearing aid, low battery, memory and telephone modes in their choice of male or female voices in a wide variety of languages. Our Swap Fit fitting function allows you to transfer patient settings from their current AGX product to a new one enabling more time for fine-tuning and counseling.

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 111/35, 111/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: IIC INVISIBLE-IN-CANAL DATA 35 Gain Data Gain Data 2cc 2cc Measurement 111 111 Peak OSPL (db SPL) 6 4 HFA OSPL (db SPL) 114 111 RTF OSPL (db SPL) 0 2 0 1K 2K 4K 8K 35 45 Peak Gain (db) 31 36 HFA Full-On Gain (db) 38 44 RTF Full-On Gain (db) 70 70 70 70 Frequency Range (Hz) IIC AGX ssl IIC fitting range. 1.6 1.6 Reference Test Frequency (khz) HFA Frequencies (khz) OSPL FOG 29 31 27 36 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <28 <28 <28 <28 Equivalent Input Noise (db SPL) 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX ssl IIC at a matrix of 111/35. Attack and Release Time () Test Mode OSPL FOG 1 Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) MASL (IEC) (db SPL) 1.1 1.1 1.2 1.2 Battery Current (ma) 1.0 1.0 1.0 1.0 Idle Current (ma) 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX ssl IIC at a matrix of 111/. Estimated Battery Life for 16-Hour Day 5-7 5-7 5-7 5-7 Zinc Air (days) 31

THE JOURNEY TO BETTER HEARING STARTS HERE 32

AGX s3s The exceptional quality and simple functionality that have made our wireless hearing aids so popular with patients and professionals is now available in an entry-level line. AGX swi A proven solution for those seeking value and performance, our AGX sto and AGX sig family of products lets you bring the benefits of wireless hearing aids to virtually all your patients. AGX sto RIC 312 34 AGX sto RIC 312 AP 35 AGX ssl DEEP CANAL INSTRUMENTS AGX sto mini BTE 312 36 AGX sto BTE 13 37 AGX sig ITE 38 AGX sig HS 39 AGX sig ITC AGX sto /AGX sig AGX sig CIC 41 SURFLINK Accessories 33

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) AGX s3s RIC 312 RECEIVER-IN-CANAL Matrices: 115/, / Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA AGX swi 0 Measurement Gain Data Gain Data 2cc 2cc Peak OSPL (db SPL) 115 125 1 HFA OSPL (db SPL) 9 115 RTF OSPL (db SPL) 116 125 2 0 1K 2K 4K 8K Peak Gain (db) 62 71 AGX ssl DEEP CANAL INSTRUMENTS OSPL AGX sto RIC 312 (gray) and AGX sto RIC 312 (black). FOG 1 HFA Full-On Gain (db) 44 54 RTF Full-On Gain (db) 53 62 Frequency Range (Hz) -70-70 -70-70 Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 32 41 38 0 00 Harmonic Distortion AGXsto/AGXsig AGX /AGX sig SURFLINK Accessories OSPL FOG OSPL (gray) and Full-On Gain (black) curves for the AGX sto RIC 312 at 115/. 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sto RIC 312 at /. 1 Induction Coil Sensitivity 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 HFA SPLITS (ANSI) (db SPL) 86 93 MASL (IEC) (db SPL) 91 Battery Current (ma) 1.7* 1.7* 2.0* 2.0* Idle Current (ma) 1.3* 1.3* 1.4* 1.4* Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 5-7* 5-7* 4-7* 4-7* * Results for wireless products will vary based on wireless usage. 34

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) Matrices: 123/, 1/ Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 RIC 312 AP RECEIVER-IN-CANAL ABSOLUTE POWER DATA Gain Data Gain Data 2cc 2cc Measurement 123 131 1 137 Peak OSPL (db SPL) 116 125 HFA OSPL (db SPL) 126 136 RTF OSPL (db SPL) 67 78 Peak Gain (db) 0 2 0 1K 2K 4K 8K 53 64 HFA Full-On Gain (db) 64 75 RTF Full-On Gain (db) AGX sto RIC 312 AP (gray), AGX sto RIC 312 AP (black) fitting ranges. - - - - 4 Frequency Range (Hz) OSPL FOG 1.6 1.6 Reference Test Frequency (khz) 1 HFA Frequencies (khz) 39 51 48 61 Reference Test Gain (db) Harmonic Distortion 0 00 <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) OSPL (gray) and Full-On Gain (black) curves for the AGX sto RIC 312 AP at 123/. <3 <3 <3 <3 Hz (%) Induction Coil Sensitivity OSPL FOG 1 95 2 HFA SPLITS (ANSI) (db SPL) 1 93 4 MASL (IEC) (db SPL) 1.2* 1.2* 1.4* 1.4* Battery Current (ma) 1.1* 1.1* 1.2* 1.2* Idle Current (ma) 0 00 Estimated Battery Life for 16-Hour Day 6-8* 6-8* 4-6* 4-6* 312 Zinc Air (days) OSPL (gray) and Full-On Gain (black) curves for the AGX sto RIC 312 AP at 1/. * Results for wireless products will vary based on wireless usage. 35

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) mini BTE 312 BEHIND-THE-EAR Matrix: 126/65 Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA Earhook Thin Tube (Size 3+, Occluded) 0 Measurement 2cc 2cc Peak OSPL (db SPL) 126 131 124 HFA OSPL (db SPL) 118 8 RTF OSPL (db SPL) 1 112 2 0 1K 2K 4K 8K Peak Gain (db) 65 64 68 AGX sto mini BTE 312 fitting range. HFA Full-On Gain (db) 52 RTF Full-On Gain (db) 69 57 Frequency Range (Hz) - 70-70 - 70-70 OSPL FOG 85 75 135 125 Reference Test Frequency (khz) 1.6 1.6 65 55 115 5 HFA Frequencies (khz) 45 95 35 85 Reference Test Gain (db) 41 53 31 37 25 75 15 65 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sto mini BTE 312 with Earhook. Harmonic Distortion 0 Hz (%) <5 <5 <2 <2 0 Hz (%) <3 <3 <1 <1 Hz (%) <3 <3 <2 <2 OSPL FOG Induction Coil Sensitivity 85 1 75 HFA SPLITS (ANSI) (db SPL) 97 87 65 55 MASL (IEC) (db SPL) 92 86 45 35 Battery Current (ma) 1.3* 1.3* 1.3* 1.3* 25 15 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sto mini BTE 312 with Thin Tube. Idle Current (ma) 1.2* 1.2* 1.2* 1.2* Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 9-11* 9-11* 9-11* 9-11* * Results for wireless products will vary based on wireless usage. 36

FOG OSPL (db) (dbspl) FOG (db) OSPL (dbspl) Hearing Level in db (HL) MATRIX: 126/65 Maximum Output: Up to db reduction in 2dB steps Compression Ratio: 1:1-3:1 Battery Size: 13 BTE 13 BEHIND-THE-EAR DATA Earhook Thin Tube (Size 3+, Occluded) 2cc 2cc Measurement 0 126 131 121 124 Peak OSPL (db SPL) 119 8 HFA OSPL (db SPL) 1 112 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 65 63 68 Peak Gain (db) 59 52 HFA Full-On Gain (db) AGX sto BTE 13 fitting range. 57 RTF Full-On Gain (db) -70-70 -70-70 Frequency Range (Hz) OSPL FOG 1.6 1.6 Reference Test Frequency (khz) 85 75 135 125 65 115 1.0,1.6, 1.0,1.6, HFA Frequencies (khz) 55 5 45 95 42 55 31 37 Reference Test Gain (db) 35 85 25 75 Harmonic Distortion 15 0 00 65 <5 <4 <2 <2 0 Hz (%) <3 <4 <1 <1 0 Hz (%) OSPL (gray) and Full-On Gain (black) curves for the AGX sto BTE 13 with Earhook. <3 <3 <2 <2 Hz (%) Induction Coil Sensitivity OSPL FOG 85 1 2 87 HFA SPLITS (ANSI) (db SPL) 75 86 MASL (IEC) (db SPL) 65 55 1.7* 1.7* 1.7* 1.7* Battery Current (ma) 45 35 1.3* 1.3* 1.3* 1.3* Idle Current (ma) 25 15 0 00 Estimated Battery Life for 16-Hour Day 9-11* 9-11* 9-11* 9-11* 13 Zinc Air (days) OSPL (gray) and Full-On Gain (black) curves for the AGX sto BTE 13 with Thin Tube. * Results for wireless products will vary based on wireless usage. 37

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) ITE IN-THE-EAR Matrices: 115/, 123/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 13 DATA 0 2 0 1K 2K 4K 8K Measurement ITE 115/ ITE 123/ 2cc 2cc Peak OSPL (db SPL) 115 124 123 1 HFA OSPL (db SPL) 116 RTF OSPL (db SPL) 116 128 Peak Gain (db) 58 68 AGX sig ITE fitting range. HFA Full-On Gain (db) 46 53 RTF Full-On Gain (db) 54 66 Frequency Range (Hz) - 60-00 - 00-5 OSPL FOG Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 33 41 39 53 Harmonic Distortion 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sig ITE at 115/. Attack and Release Time () Test Mode 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Attack Time (ms) OSPL FOG 1 Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 95 1 MASL (IEC) (db SPL) 83 95 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sig ITE at 123/. Battery Current (ma) 1.22 1.22 1.22 1.22 Idle Current (ma) 1.14 1.15 1.13 1.13 Estimated Battery Life for 16-Hour Day 13 Zinc Air (days) 12-16* 12-16* 12-16* 12-16* * Results for wireless products will vary based on wireless usage. 38

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 HS HALF-SHELL DATA HS / HS 115/ 0 2cc 2cc Measurement 119 115 124 Peak OSPL (db SPL) 5 9 HFA OSPL (db SPL) 111 116 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 49 58 Peak Gain (db) 36 46 HFA Full-On Gain (db) AGX sig HS fitting range. 43 53 RTF Full-On Gain (db) - 00-70 - 60-60 Frequency Range (Hz) 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 28 36 32 41 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sig HS at /. Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) OSPL FOG 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity 89 94 HFA SPLITS (ANSI) (db SPL) 71 82 MASL (IEC) (db SPL) 1.22 1.22 1.22 1.22 Battery Current (ma) 1.15 1.15 1.15 1.15 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sig HS at 115/. 8-9* 8-9* 8-9* 8-9* 312 Zinc Air (days) * Results for wireless products will vary based on wireless usage. 39

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) ITC IN-THE-CANAL Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: 312 DATA 0 ITC / ITC 115/ Measurement 2cc 2cc 2 0 1K 2K 4K 8K Peak OSPL (db SPL) 119 115 124 HFA OSPL (db SPL) 5 9 RTF OSPL (db SPL) 111 116 Peak Gain (db) 49 58 AGX sig ITC fitting range. HFA Full-On Gain (db) 36 46 RTF Full-On Gain (db) 43 53 Frequency Range (Hz) - 00-70 - 60-60 OSPL FOG Reference Test Frequency (khz) 1.6 1.6 HFA Frequencies (khz) Reference Test Gain (db) 28 36 32 41 Harmonic Distortion 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sig ITC at /. Attack and Release Time () Test Mode 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) <3 <3 <3 <3 Attack Time (ms) OSPL FOG Release Time 0.1s (ms) 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) 5-1 5-2 5-1 5-2 Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) 89 94 MASL (IEC) (db SPL) 71 82 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sig ITC at 115/. Battery Current (ma) 1.22 1.22 1.22 1.22 Idle Current (ma) 1.15 1.15 1.15 1.15 Estimated Battery Life for 16-Hour Day 312 Zinc Air (days) 8-9* 8-9* 8-9* 8-9* * Results for wireless products will vary based on wireless usage.

FOG (db) OSPL (dbspl) FOG (db) OSPL (dbspl) Matrices: /, 115/ Maximum Output: Up to db reduction in 2dB steps Compression Threshold: 24dB range in 4dB steps Compression Ratio: 1:1-3:1 Battery Size: CIC COMPLETELY-IN-CANAL DATA CIC / CIC 115/ 0 2cc 2cc Measurement 119 115 124 Peak OSPL (db SPL) 4 HFA OSPL (db SPL) 115 RTF OSPL (db SPL) 2 0 1K 2K 4K 8K 49 58 Peak Gain (db) 35 46 HFA Full-On Gain (db) AGX sig CIC fitting range. 43 54 RTF Full-On Gain (db) - 70-70 - 70-70 Frequency Range (Hz) 1.6 1.6 Reference Test Frequency (khz) OSPL FOG HFA Frequencies (khz) 28 35 32 Reference Test Gain (db) Harmonic Distortion <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 0 Hz (%) <3 <3 <3 <3 Hz (%) Attack and Release Time () Test Mode 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sig CIC at /. Attack Time (ms) 5-1 5-2 5-1 5-2 Release Time 0.1s (ms) OSPL FOG 5-1 5-2 5-1 5-2 Release Time 2.0s (ms) Induction Coil Sensitivity HFA SPLITS (ANSI) (db SPL) MASL (IEC) (db SPL) 1.17 1.17 1.17 1.17 Battery Current (ma) 1.12 1.12 1.13 1.13 Idle Current (ma) Estimated Battery Life for 16-Hour Day 0 00 OSPL (gray) and Full-On Gain (black) curves for the AGX sig CIC at 115/. 4-6* 4-6* 4-6* 4-6* Zinc Air (days) * Results for wireless products will vary based on wireless usage. 41

Carefree connectivity IS HERE 42

AGX s3s Combined with any of our wireless hearing aids, Starkey s innovative and popular lineup of SurfLink accessories gives your patients unprecedented control, convenience and freedom. AGX swi SurfLink Features 44 AGX ssl DEEP CANAL INSTRUMENTS AGX sto /AGX sig SURFLINK Accessories 43

AGX s3s AGX swi Cell Phone Noisy Places Lectures LIFE WITHOUT LIMITATIONS Meetings Music AGX ssl DEEP CANAL INSTRUMENTS Television SURFLINK MOBILE Hands-free phone conversations (and more) are here with SurfLink Mobile. This versatile device is the industry s most unique cell phone solution, assistive listening device, media streamer, and hearing aid remote all rolled into one. AGX sto /AGX sig SURFLINK Accessories Using our revolutionary JustTalk mode, SurfLink Mobile enables hands-free cell phone conversations by turning our wireless hearing aids into the phone microphone and receiver: o Microphone The wearer s hearing aids pick up their voice and send it to the person they re talking to o Receiver SurfLink Mobile streams the voice on the other end of the phone directly to both of the wearer s hearing aids for binaural listening Directional microphone enhances one-onone conversations in noisy environments Omnidirectional capability is ideal for listening in meetings or group settings Wirelessly streams sound from TVs or MP3 players using Bluetooth or an audio connector cable Can also be used as a powerful ALD as well as a hearing aid remote 44

SURFLINK MEDIA SurfLink Media provides patients with the first set-and-forget media streaming solution. Simply plug a TV, radio or MP3 player into SurfLink Media and rich, stereo sound is streamed directly to any wireless hearing aids in range without pairing or body-worn relay devices. SurfLink Media: Streams stereo sound directly from media devices to the patient s hearing aids without pairing or body-worn relay devices Uses Intelligent Media Mobility to allow seamless room-to-room transitions between media devices Enables multiple people wearing wireless hearing aids to connect to a single device Eliminates audio delay and lip-sync issues* commonly found with other wireless systems Helps prevent patients and companions from fighting over the volume SURFLINK Programmer Our SurfLink Programmer, combined with IRIS Technology and Inspire fitting software, gives you the ultimate speed and flexibility in direct-to-hearing aid wireless programming with no relay device. Detects your patients wireless devices in seconds Features at least a -foot range Frees patients to move around during counseling and demonstrations Connects via standard USB cable Requires no additional hardware for the patient Is 4x faster than HiPro and nearly twice as fast as NOAHLink and nearcom SURFLINK Remote With the optional SurfLink Remote, patients can control memory and volume adjustments, mute their hearing instruments, or go in and out of streaming mode if they desire. *Latency is unnoticeable according to International Telecommunications Union standards 45

Measurement Conditions and Recommendations The data for AGX hearing instruments are obtained and performance is expressed according to ANSI S3.22 (03), ANSI C63.19 (07), IEC 118-7 (05) and IEC 118-0 (1983) with Amendment 1 (1994-01). The Starkey proprietary Real Time Analyzer and the Starkey Automated Design Verification Test System comprise the basic test equipment. Data may be subject to change with product refinement. Because of the adaptive signal processing capabilities of AGX hearing instruments, the hearing instrument must be set to test mode to compare the actual performance of the hearing instrument with these specifications. AGX hearing instruments may be set to test mode with Inspire by reading the hearing aid and selecting the Hearing Aid Test screen from the menu on the left side of the Inspire window, then selecting the Full on Gain button. *All trademarks or trade names are properties of their respective owners. 46