ITS-I. Test station for evaluation of image quality of image intensifier tubes. Fig. 1. Photo of the ITS-I test station: a)photo, b)block diagram

Similar documents
IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

CBF500 High resolution Streak camera

We bring quality to light. SNT 10 DC Power Supply

WATCHMASTER IP THERMAL SURVEILLANCE SYSTEMS

ET-5050x-BF1W Datasheet

Essentials of the AV Industry Welcome Introduction How to Take This Course Quizzes, Section Tests, and Course Completion A Digital and Analog World

Measurement of Microdisplays at NPL

watchmaster IP Thermal surveillance systems

ELECTRON OPTICS OF ST-X, ST-Y SERIES OF STREAK & FRAMING CAMERA TUBES

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

Scanning System S-2100

LCD MODULE SPECIFICATION

Monitor QA Management i model

LED Display Product Data Sheet LTC-5623SW Spec No.: DS Effective Date: 04/11/2013 LITE-ON DCC RELEASE

Dual Power and Control. Backup System. Armor. SUT43X Series. Ideal Solution For Control Room

Video Series. HCS-4311M Professional Mixed Matrix for Conference 8.2. HCS-3313C High Quality Speed Dome Camera (ceiling) 8.5

STAR-07. Industrial Pattern Projection. System Architecture. System Control

OPTICAL POWER METER WITH SMART DETECTOR HEAD

V9A01 Solution Specification V0.1

Ch. 1: Audio/Image/Video Fundamentals Multimedia Systems. School of Electrical Engineering and Computer Science Oregon State University

DT3130 Series for Machine Vision

Video Digital Optical Converter

Federal 3535 Single Color Datasheet

2.4.1 Graphics. Graphics Principles: Example Screen Format IMAGE REPRESNTATION

LCD Display Wall Narrow Bezel Series

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

ELECTRO-OPTIC TECHNOLOGY DIVISION SPECIAL OPERATIONS EO SYSTEM BRANCH CODE JXQR

ModBox-850nm-NRZ-series

ALS-PDIC17-77C/TR8. Surface - Mount Ambient Light Sensor. Features. Description. Applications

BARCOVISION 708 SERIES

Communication Theory and Engineering

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

YOUR FUTURE. ON DISPLAY.

MXAN-LN series 1550 nm band Analog Intensity Modulators

SPATIAL LIGHT MODULATORS

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Displays AND-TFT-5PA PRELIMINARY. 320 x 234 Pixels LCD Color Monitor. Features

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Specifications SMART Board 6075 interactive flat panel with iq Model SPNL-6275

MXAN-LN series 1550 nm band Analog Intensity Modulators

For high performance video recording and visual alarm verification solution, TeleEye RX is your right choice!

CAEN Tools for Discovery

BUREAU OF ENERGY EFFICIENCY

DATE DESCRIPTION CHANGED BY. CHECKED BY FROM TO A First Release. ZENG LI HUANG YUAN LIANG

AND-TFT-25XS-LED-KIT. 160 x 234 Pixels LCD Color Monitor AND-TFT-25XS-LED-KIT. Features

ModBox-1310nm-1550nm-28Gbaud-PAM nm & 1550 nm, 28 Gbaud PAM-4 Reference Transmitter

Salient Systems June, N Mopac Expy, Bldg 3, Ste 700 Austin, Texas FAX

Connection for filtered air

Color Spaces in Digital Video

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

WAH WANG HOLDINGS (HONG KONG) CO., LTD.

Buhl Industries VP-30 Visual Presenter. USER MANUAL Version

IMPAC Infrared Thermometers

Eddy Current Technology. eddyliner. digital

3. Fibre Gripper - Includes a simple adaptor to fit 70mm glass slides to the OFDA 4000 for measuring fibre snippets (not shown)

IMPAC Infrared Thermometers

Module 7. Video and Purchasing Components

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

USB Smart Power Sensor

Data. X-ray Image Intensifier HIDEQ 23-3 ISP

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

XC-77 (EIA), XC-77CE (CCIR)

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

Large 5 X 7 Dot Matrix Alphanumeric Displays 17.3/26.5 mm Character Heights Technical Data

Ethernet to VGA over IP Converter

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Outline Dimension. View Angle

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

Types of CRT Display Devices. DVST-Direct View Storage Tube

YCbCr (480i/576i) and RGBsync. 4 Press Component to change source to component connec tor. This connector supports YPbPr (480p/576p/720p/1080i)

Application Note 20D45X Family

Stereo Box Pre Box Amp Box Amp Box Mono Switch Box. Tuner Box Dock Box F / V Phono Box MM Record Box USB Phono Box II

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Flash Single Color Datasheet

55 (54.6 viewable) Full HD Direct-lit LED Commercial Display CDE5502 Direct LED backlight technology for superior color performance

G ARD SECURITY SYSTEM Product Listing 2007

KS5600 USB E. Rev KS5600 USB E. Digital 1-CCD OEM Color Video Camera

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

3CCD Color Video Camera BRC-300 BRC-300P. USA Security Systems

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS:

Security and Surveillance Monitor Solutions

OLED THE PERFECT HIGH-RESOLUTION DISPLAY

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Fine Pitch LED Display System

Multi-function Portable. HD LCD Monitor. User Manual

User Guide

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1210

The ViewSonic VX2778-smhd is a 27 WQHD LCD monitor with 2560x1440 resolution and SuperClear IPS Panel technology. This monitor offers best-in-class

VP2780-4K. Best for CAD/CAM, photography, architecture and video editing.

Thank you for your interest in BARCO s dedicated Home Theater products and more particular in our top-model, the CINE9.

Item Symbol Absolute Maximum Rating Unit Remarks

Palette Master Color Management Software

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

DEM A VMH-PW-N 5 TFT

SPECIFICATION. DVB-T/ DVB-C / Worldwide hybrid Switchable NIM Tuner

DCI Requirements Image - Dynamics

HITACHI. Instruction Manual VL-21A

Transcription:

OS-1 stage Monitor S-I support VM-I microscope M-I microscope Control center Target projector OS-2 stage DC-I camera Tube holder P-I platform IM meter Target slider a) b) BASIC INFORMATION: LVS voltage supply IL-I illuminator BM-I base module Fig. 1. Photo of the ITS-I test station: a)photo, b)block diagram Image intensifier tubes are the most important modules of night vision devices that play crucial role in defence/security/industrial applications. Technology of manufacturing of image intensifier tubes is very difficult and performance parameters of modern image intensifier tubes varies even within the same technological process. Next, test report offered by manufacturers cannot be fully trusted because there are some differences in test methods used by different manufactures. Further on, there are literature sources presenting conflicting claims of different manufacturers. It is quite common to find on the world market two night vision devices (or two image intensifier tubes) of the same data sheet parameters but of totally different image quality. Inverse situation is possible, too. Due to reasons mentioned above testing image intensifier tubes is of critical importance for both their manufacturers, manufacturers of night vision devices (NVDs) and final users of NVDs. Testing of image intensifier tubes is typically done according to methods recommended by US MIL standards. These test methods refer to testing potted tubes after encapsulation. There are however some projects when more detail testing is needed using non- MILs methods or bare tubes before encapsulation are to be tested. PC, soft ware Inframet is a top leader in equipment for testing image intensifier tubes and offers a series of high tech test stations. These stations can be divided into three main groups optimized for different applications: ITS series stations, IRAD test stations, IPAS test stations. ITS series stations are developed for testing potted image intensifier tubes using typical test methods recommended by MIL standards. ITS-P station enables measurement of photometric parameters, ITS-I station enables measurement of imaging parameters, ITS-R station enables measurement of reliability parameters, and optional ITS-IP enables measurement imaging and most important photometric parameters. These stations are optimal for great majority of users of image intensifier tubes. This data sheet presents technical parameters of ITS-I station that enables measurement of image quality parameters of image intensifier tubes. The ITS-I station projects images of some standard targets to tube photocathode plane and measures distortion of the output images of these targets created at the tube screen. The stations can optionally enables also measurement of some photometric parameters. Bare tube can optionally be tested, too.

1 Design concept ITS-I station projects images of some standard targets to tube photocathode plane and measures distortion of the output images of these targets created at the tube screen. As shown in block diagram (Fig. 1b) ITS-I station is built from three main groups of blocks: 1. BM-I base module (light source, set of targets, image projector) 2. Set of tools for image evaluation (VM-I video microscope, DC-I digital camera, M-I microscope and manual optical stages) 3. PC set and software (PC, frame grabber and software for semi-automatic evaluation and recording results: TAS-I software, ITS Display software, MC Viewer software). BM-I module project images of some standard targets to the photocathode of the tested tube. The tube generates at its screen a distorted copy of the original image created at the photocathode. The distorted copy image is later analyzed using a set of tools for image evaluation: a)vm-i video microscope, b)dc-i digital camera, c)classical M-I microscop and d)optional luminance probes. PC set and software (PC, frame grabber, TAS-I, ITS Display, MC Viewer) enable capturing and analysis of images generated by VMI video microscope and DC-I camera. Resolution (center, peripheral, high level) of image intensifier is typically measured by analysis of images of USAF 1951 target generated by VM-I video microscope. This is subjective analysis where final decision is made by human observer but the observer is supported by software (TAS-I computer program and MRC computer program). Another option is measurement of resolution using classical microscope method (M-I microscope). Modulation Transfer Function (MTF), Signal To Noise Ratio (S/N), Halo, Image Non-Alignment, Shear Distortion,, Image Inversion, Magnification are measured semi-automatically using TAS-I computer program by analysis of images generated by VM-I video microscope. Dark and bright spots, Output Brightness Uniformity, Gross Distortion, Multi-Multi Pattern Noise, Multi- Boundary Pattern Noise, Temporal Distortion and measured semi-automatically using TAS-I computer program by analysis of images generated by CD-I camera. The earlier mentioned test concept refer to testing typical potted image intensifier tubes. If additional set of three HVP power supplies is delivered and BM-I base module modified then ITS-I station can enable testing both potted and bare tubes. Test capabilities of ITS-I station are generally limited to measurement of imaging parameters. However this station can be modernized to a station ITS-IP capable to measure both imaging and photometric parameters. 2 Technical parameters 2.1 BM-I base module BM-I base module is the main module of the ITS-I station. BM-I module in general serves as: 1. light source (IL-I illuminator) 2. target projector 3. source of low voltage power supply for the tested tubes 4. holder for the tested tubes 5. control center of the mentioned above light source, voltage source and target slider; display for the illuminance and the target projector, communication with PC Table. 1. Parameters of BM-I base module IL-I illuminator Light Source 1)halogen 2850K color temperature source 2)monochromatic 595 nm light source Illuminance range 20 µlx to 2lx (standard) 200lx -option Regulation resolution up to 2 lux (at low intensity range) Regulation type continuous (any value can be set within the regulation range) Regulation mechanism manual Regulation stability better than 2% of the set value Illuminance uncertainty better than 5% of the set value Target projector

Targets single multi-pattern target having the following patterns: USAF1951 pattern, edge/slit pattern, pinhole pattern, tube diameter pattern, gross/shear distortion pattern, uniform/spot pattern Resolution of target projector 400 [1p/mm] Target slider Manual Tube holders Mechanical holders MX-10160, MX-10130, MX-11620, MX-9444 or equivalent (other types possible, too) LV power source type DC voltage 2.7 V (option: regulation from 2V to 3.5V) 2.2 Tools for image evaluation Table. 2. Parameters of tools used for image evaluation VM-I video microscope Type Sensitivity 1mlx Image resolution 768 x 576 Field of view high resolution, high sensitivity CCD camera integrated with custom macro objective, custom image processing electronics (linearized response, improved temporal stability, increased apparent frame rate) 1,47 x 1,2mm Magnification >100 (depends on monitors settings) Resolution of macro objective >354 lp/mm DC-I digital camera Type High resolution digital still camera Depth of focus Over 3.9 mm (optimized for testing tubes with curved screens) Image resolution 3072 x 2048 Field of view Dual FOV (optimized for 18mm and 25 mm II tubes) Minimal Field of View 28.5 x 19 mm Pixel 9.3 m (at minimal FOV) Image transfer USB 2.0 M-I microscope type visual magnification resolution 2.3 PC and frame grabber mono 50x or 10x (other magnifications optional) >226 lp/mm Table. 3. Basic parameters of the PC and the frame grabber PC description modules memory Processor graphics card monitor Hard disk Frame grabber Typical desktop PC PC main unit, monitor, keyboard, mouse 1024 MB RAM DDRAM (at least) Intel Pentium G645 or better AGP 64 MB GeForce4 (or better) Minimal resolution 1280 1024@75 Hz. At least 500GB

Capture resolution (at 25/30 Hz) 768 x 576 (PAL) 640 x 480 (NTSC) Input formats PAL, NTSC, USB 2.0 Capture quality Non-noticeable degradation of image quality SNR > 256 2.4 Test software There are three computer programs that are offered by Inframet as parts of ITS-I test station: 1. ITS Display program, 2. TAS-I program, 3. MC Viewer. ITS Display is a computer program that keeps communication between BM-I base module and PC. Program enables acquisition of data about input illumination at photocathode plane and output luminance at tube screen plane. It is used for semi-automatic measurement of optional photometric parameters (luminance gain, saturation level and EBI). Fig. 2. Control window of ITS Display program TAS-I is a computer program that enables the following functions: 1. Acquisition of the output images generated by VM-I video microscope 2. Acquisition of the output images generated by DC-I digital camera 3. Calculations of the following characteristics of the tested II tube: MTF, Signal To Noise Ratio (S/N), Blemishes, Output Brightness Non Uniformity, Useful tube diameter, Halo, Image Alignment, Shear Distortion, Gross Distortion, Multi-multi noise, Multi boundary noise, Image inversion. Fig. 3. Image of an exemplary tube with marked dark spots generated by TAS-I computer program. The tube area is divided into sectors according to MIL standards recommendations.

Fig. 4. Spot search results window of TAS-I computer program MC Viewer is a computer program that enables visualization of several video sequences of images generated by tested II tubes on PC screen at the same time. Humans can rather poorly compare images from different tubes seen at different moments of time. However, humans can very accurately compare quality of images generated by different II tubes when images are presented at the same time. MC Viewer is particularly useful for people limited technical knowledge testing II tubes who cannot properly interpret parameters of these tubes but can easily interpret video recordings. Fig. 5. MC Viewer window: video sequences of USAF 1951 target generated by four image intensifier tubes 2.5 Set of high voltage power supplies The HVP high voltage power supply is a special power supply optimized for use in systems for testing bare image intensifier tubes. It is built as set of of four HV power modules: HVP-1 to power photocathode circuit, : HVP-2 to power MCP circuit, HVP-3 to power screen circuit, and HVP-4 an option for some Gen3 tubes. The HVP power supply differ significantly from typical laboratory high voltage power supplies. The HVP power modules can be connected into a cascade. Flexible grounding (any output socket of any power supply can be grounded) is possible, too. Next, the voltage regulation ranges are optimized for testing bare image intensifier tubes.

Fig. 6. Photo of HVP power supply Table. 4. Parameters of HVP power supplies Parameter Value HVP-1: 10 to 1000 V - optimized for photocathode Output voltage range HVP-2: 30 to 3000 V - optimized for MCP HVP-3: 80 to 8000 V optimized for screen Max output current 100 A HVP1, HVP2 50 A HVP3 Type of regulation manual Ripple <0.1 % pp Temperature stability <300ppm/K Humidity Up to 90% non-condensing Working temperature 5ºC to 40 ºC Storage temperature -10ºC to 65ºC 3 Versions of ITS-I test station ITS-I test station can be delivered in different versions optimized for different customers. Both measurement capability and price depends significantly on version number. ITS test system - version ITS-I/A1 ITS-I/A2 ITS-I/B ITS-I/B2 ITS-I/C1 Capability Components BM-I/A base module, M-I microscope, OS-1 stage, microscope set of 3 tube holders. BM-I/A base module, M-I microscope, OS-1 stage, microscope or video camera with software set of 3 tube holders, VM-I video microscope, PC, support frame grabber, TAS-I/A2 program, ITS Display microscope, semi-automatic measurement of blemishes (dark and bright spots), cathode diameter, gross distortion, output brightness non uniformity (at visible range) the same as in version ITS-B but additionally measurement of luminance gain and saturation level microscope or video camera with software support, semi-automatic measurement of program, MC Viewer program BM-I/B base module, M-I microscope, OS-2 stage, set of 3 tube holders, PC, TAS-I/B computer camera BM-I/B2 base module, M-I microscope, OS-2 stage, set of 3 tube holders, PC, TAS-I/B computer camera, LP1 luminance probe BM-I/C1 base module, M-I microscope, VM-I video microscope, OS-1 stage, OS-2 stage, set of 3 tube holders, PC, frame grabber, TAS-I/C1 computer

/C2 ITS-I/D ITS-I/E ITS- I/MSR ITS-I MTF, blemishes (dark and bright spots), halo, cathode diameter, gross distortion, output brightness non uniformity microscope or video camera with software support, semi-automatic measurement of blemishes (dark and bright spots), cathode diameter, gross distortion, alignment, output brightness non uniformity, halo, rise time, decay time and phosphor decay time microscope or video camera with software support, semi-automatic measurement of MTF, SNR, blemishes (dark and bright spots), cathode diameter, gross distortion, output brightness non uniformity, halo, image alignment microscope or video camera with software support, semi-automatic measurement of MTF, SNR, blemishes (dark and bright spots), cathode diameter, gross distortion, output brightness non uniformity, halo, image alignment, image inversion, magnification, temporal magnification Measurement of MTF, SNR, resolution camera, MC Viewer program BM-I/C2 base module, M-I microscope, VM-I video microscope, OS-1 stage, OS-2 stage, set of 3 tube holders, PC, frame grabber, TAS-I/C2 computer camera, TP temporal probe, MC Viewer program, ITime computer program BM-I/D base module, M-I microscope, VM-I video microscope, OS-1 stage, OS-2 stage, set of 3 tube holders, PC, frame grabber, TAS-I/D computer camera, MC Viewer program BM-I/E base module, M-I microscope, VM-I video microscope, OS-1 stage, OS-2 stage, set of 3 tube holders, PC, frame grabber, TAS-I/E computer camera, MC Viewer program BM-I/MSR base module, VM-I video microscope, M-I microscope, OS-1 stage, set of 3 tube holders, PC, frame grabber, TAS-I/MSR computer program, P-I platform, S-I support, ITS Display computer program, MC Viewer program ITS-I/MT Measurement of MTF BM-I/MT base module, VM-I video microscope, M-I microscope, OS-1 stage, set of 3 tube holders, PC, frame grabber, TAS-I/MT computer program, P-I platform, S-I support ITS-I/SN Measurement of SNR BM-I/SN base module, VM-I video microscope, M-I microscope, OS-1 stage, set of 3 tube holders, PC, frame grabber, TAS-I/SN computer program, P-I platform, S-I support, ITS Display computer program The codes presented above refer to versions to be used for testing potted tubes. Testing bare tubes requires additional modules: HV power supplies and tube holders. These modules can be delivered by Inframet as an additional option 4 Comparison of ITS-I and other test stations There are other commercially available test stations that can be used for measurement of image quality parameters. Here we will compare different versions of ITS-I test stations with other commercially available test stations. ITS-I test station represent a new generation of test stations for testing image quality of II tubes. It was developed by Inframet in 2004 year as the first commercially available single test station that enabled measurement of all image quality parameters. A few commercially available test stations were needed to do the same task. Since 2004 ITS-I test station has been significantly improved and at the same time has passed a series of tests in different countries that confirmed its capabilities as a truly modern test station that wins any practical comparison to other test stations. Here we will present some of its features that present advantages of ITS-I over other test stations.

1. Fast semi automatic measurement method. Humans are still necessary and important but they are supported by software that increase measurement speed and accuracy. 2. Possibility to record all input data (images) and measurement results. 3. Compact design of ITS-I station. Some other test stations are a collection of laboratory equipment placed on a laboratory table. 4. Due to use of special tube holders the tests do not have to be carried out in total darkness. It is enough if tests are carried out in rooms where illumination is at level about 0.5 lx that enable relatively comfortable conditions for humans. 5. Possibility to compare online video images of USAF target generated by the tested tube to video images of the USAF target generated by a standard tube at the same time on PC screen. This feature significantly improved measurement speed and accuracy of resolution by human observers. 6. Continuous regulation of illumination level. Any level from 2 10-5 lux to 2 lx can be set. In typical test stations only several illumination levels are available. 7. Custom designed image projector of extremely high limiting resolution (resolution over 400 lp/mm). Typical test stations use typical commercial photographic macro objectives of limited quality to project images (resolution not higher than 100 lp/mm according to data from manufacturers of photographic objectives).medium resolution image projector can decrease accuracy of measurement of the resolution of tested image intensifier tube. The combination of all these factors enabled us to built ITS-I test station: the best commercially available test station for testing modern image intensifier tubes. Attention: Minor details of these specifications are subject to change without prior notice. These changes can be made due to continuous improvement of Inframet products. However, in any case the changes shall not reduce measurement capabilities of ITS-I test station. Version 4.3 dated 23.08.2017 CONTACT: Tel: +48 604061817 Fax: +48 22 3987244 Email: info@inframet.com