Transfer Radiation Thermometer With Temperature Range Of 0 C To 3,000 C

Similar documents
IMPAC Infrared Thermometers

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

COMPARED IMPROVEMENT BY TIME, SPACE AND FREQUENCY DATA PROCESSING OF THE PERFORMANCES OF IR CAMERAS. APPLICATION TO ELECTROMAGNETISM

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Product Data Sheet 4656 EZ

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

In-process inspection: Inspector technology and concept

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S ZN-Z85 Switch Matrix Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S ZN-Z154 Calibration Unit Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S ZN-ZTW Torque Wrench Specifications

IMPAC Infrared Thermometers

Uncooled amorphous silicon ¼ VGA IRFPA with 25 µm pixel-pitch for High End applications

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Standard Operating Procedure of nanoir2-s

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Fluke 279 FC True-rms Thermal Multimeter

watchmaster IP Thermal surveillance systems

Connection for filtered air

R&S SMBV-Z1 Reference Frequency Converter Specifications

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Test of ScannerMAX Saturn 1 with 600Hz Sine-wave input, having an optical scan angle of 40 optical degrees peak to peak.

Scanning System S-2100

R&S HF907DC SHF Downconverter Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

HP 70950B OPTICAL SPECTRUM ANALYZER

Altman Lighting Spectra Cyc 50 Specification

Polygon Scanners Capabilities, Applications and System integration. considerations

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems

WATCHMASTER IP THERMAL SURVEILLANCE SYSTEMS

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Lt DELTA USA, Inc

R&S RT-Zxx Standard Probes Specifications

Keysight Technologies Power Sensor Modules Optical Heads Return Loss Modules. Data Sheet

Security Driven by Intelligence.

Advanced Test Equipment Rentals ATEC (2832)

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator)

Sealed Linear Encoders with Single-Field Scanning

specification display applications cronus spectrometer & colorimeter

SC24 Magnetic Field Cancelling System

THE OPERATION OF A CATHODE RAY TUBE

SPATIAL LIGHT MODULATORS

Industrial Diode Laser (IDL) System IDL Series

L5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2

SC24 Magnetic Field Cancelling System

Compact multichannel MEMS based spectrometer for FBG sensing

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

R&S ZVA110 Vector Network Analyzer Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

Screen investigations for low energetic electron beams at PITZ

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Mechanical aspects, FEA validation and geometry optimization

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

LD OEM/LD PDS/LD PeCo

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

CCD Element Linear Image Sensor CCD Element Line Scan Image Sensor

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

DPD80 Infrared Datasheet

Advanced Digital Melting Point Apparatus

DIRECT DRIVE ROTARY TABLES SRT SERIES

Features. Applications

Precision testing methods of Event Timer A032-ET

R&S AVG050 DVB Satellite Receiver Specifications

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Calibrating attenuators using the 9640A RF Reference

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Agilent 81600B Tunable Laser Source Family

LadyBug Technologies LLC Manual PowerSensor+ Field Certification Procedure

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Label Applicator HERMA 400

M2-Measurement Report

NONDESTRUCTIVE INSPECTION OF A COMPOSITE MATERIAL SAMPLE USING A LASER ULTRASONICS SYSTEM WITH A BEAM HOMOGENIZER

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

RST INSTRUMENTS LTD.

Magnetic Stirrers Magnetic Stirr

DESIGN OF VISIBLE LIGHT COMMUNICATION SYSTEM

Product Data Sheet 8506 VW-691

OM2000N INSTALLATION MANUAL

LED-Strip C12 MK2.6. Product Sheet

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

S30-RP LED Soft Light

Transcription:

Transfer Radiation Thermometer With Temperature Range Of 0 C To 3,000 C At 8 µm To 14 µm O. Struss 1, H-P. Vietze 2 1 HEITRONICS Infrarot Messtechnik GmbH, Wiesbaden, Germany E-mail: ortwin.struss@heitronics.com 2 HEITRONICS Infrarot Messtechnik GmbH, Wiesbaden, Germany E-mail: hans-peter.vietze@heitronics.com Abstract. The paper will present the performance, specification and design of the Transfer Radiation Thermometer IV.82 (TRT IV.82) which covers a temperature range of 0 C to 3,000 C in one temperature range. It has a spectral response of 8 µm to 14 µm. More and more Infrared Thermographic Cameras and Infrared Radiation Thermometers are used in industry for manufacturing, inspection and improvement of the product quality. Today those instruments cover the temperature ranges from -50 C up to 3,000 C. Their spectral responses are typically 3 to 5 µm or 8 to 14 µm. For high level calibration Transfer Radiation Thermometers are needed that cover those temperatures. The TRT IV.82 has been designed and developed to improve the accuracy in long wave spectral band and high temperatures. The size of source effect (SSE) is optimized for the spectral range of 8 µm to 14 µm. It can be used as a Transfer Standard Radiation Thermometer (TSRT) for the transfer of radiation temperatures in VTBB scheme [1]. It will be calibrated against high grade blackbody radiators (BBR) according to ITS 90 and it is capable to transfer radiation temperatures between black body radiators (BBR). The instrument has an industrial design with the benefits and means of ruggedness, transportation and handling and the performance of a transfer standard. The construction of the thermometer and the test performed to characterize it are described. General specifications, spectral response, temperature resolutions, influence of ambient temperature and humidity as well as size of source effects (SSE) are investigated and presented in this paper. Keywords: Transfer Radiation Thermometer, High temperature, 8 µm to 14 µm, calibration INTRODUCTION More and more Infrared Thermographic Cameras and Infrared Radiation Thermometers are used in industry for manufacturing, inspection and improvement of the product quality. Today those instruments cover the temperature ranges from -50 C up to 3,000 C. Their spectral responses are typically 3 to 5 µm or 8 to 14 µm. For high level calibration Transfer Radiation Thermometers are needed that cover those temperatures. The Transfer Radiation Thermometer IV.82 (TRT IV.82) has been designed and developed to improve the accuracy in long wave spectral band and high temperatures. The size of source effect (SSE)[2] is optimized for the spectral range. It can be used for the transfer of radiation temperatures in the VTBB scheme [1]. DESIGN The TRT IV.82 has an industrial design, it is based on the Transfer Radiation Thermometer II (TRT II) [3] The optical design, the electronics and the software of the instrument were modified to higher performances than the industrial version, e.g. NETD (Noise Equivalent Temperature Difference), SSE (Size of Source Effect) and thermal drift. The operating principle is based on the chopped radiation method. In this instrument a pyroelectric detector is used. The TRT IV.82 covers temperature ranges from -50 C up to 3,000 C (in four different temperature ranges) on blackbody sources. Outputs are provided either in temperature or radiance equivalent values. Emissivity value can be set between 0.100 and 1.000. The instrument provides a field of view (FOV) of approximately 6.8 mm @ 380 mm. For calibration the minimum spot size has to be positioned at the opening of the calibration source. A built-in laser-marker facilitates aiming on the center of the field of view. For convenient operation the TRT IV.82 has three outputs, which can be individually configured: a display at the rear side of the instrument, which indicates the value in temperature. (It can be configured in C, F and K.)

a the serial interface RS232C for readouts in temperature or radiance values. an analog output for the readout signal (ma or Volt) which can be configured either in temperature or in radiance values. FIGURE 1. Design of the TRT IV shows the layout of the instrument with optical path for the measurement, the through the lens sighting and the laser beam for marking the field of view. Temperature Range 4 3 2 1 TEMPERATURE AND DYNAMIC RANGES The first TRT has been designed and developed in the TRIRAT project [4]. It covers the temperature range from -50 C up to 300 C with a spectral range from 8 µm to 14 µm. To expand the temperature ranges up to 3,000 C creates the need of a much higher (radiance) dynamic range. While the temperature range up to 300 C means a dynamic range of 660:1, the temperature range up to 3,000 C means a dynamic range of 13,460:1 (see fig.2) The TRT IV.82 s are available in four different versions with temp. ranges of -50 C to 1,000 C up to 0 C to 3,000 C. The different temperature ranges means different gain settings of the instruments. The wider temperature ranges have also the meaning of a slightly higher NETD at higher temperatures. Dynamic Ranges 4 :: 0-3,000 C 3 :: -50-2,000 C 2 :: -50-1,200 C 1 :: -50-1,000 C 0 100 200 300 400 500 600 700 Dynamic Range (X*1000 : 1) FIGURE 2 Dynamic Ranges for the Temperature Ranges 1 to 4 NOISE EQUIVALENT TEMPERATURE DIFFERENCE (NETD) VERSUS TEMPERATURE The NETD has been measured in front of blackbodies providing temperatures up to 2,000 C The TRT was photoelectric aligned in front of the blackbodies in the horizontal and vertical plane. The measurement values were acquired with the aid of the serial interface over a period of approx. 2 minutes for each temperature value. The NETD values are measured from 39 C to 2,000 C. During the measurement the response time is set to 3 sec. The NETD stated in the table is the expanded NETD of the measurement obtained by multiplying the standard value by the coverage factor k=2. The temperature fluctuation of the BBR was smaller than the registered NETD TABLE 1. Noise Equivalent Temperature Difference (NETD) vs Blackbody Temperature for TRT IV.82 Black body radiator Temp. / C NETD for 3 s Black body radiator response Temp. / C time /K 39 0.04 1000 0.03 150 0.03 1150 0.03 300 0.04 1700 0.09 650 0.04 2000 0.25 NETD for 3 s response time /K

SSE IMPROVEMENT The instrument provides a field of view of 6.8 mm @ 380 mm for 99 % collected radiation. The SSE graph shows improvable values for diameters between the nominal diameter and 30 mm. To improve this diameter range to a higher SSE value has been the part of the work to achieve higher performance. The layout of the inner optical path is redesigned. Field stop diameter and positions where adjusted and optimized to shift this diameter range to a SSE level of 0.998 or higher. SSE /% 1.00 0.99 0.98 0.97 SSE Size of Source Effect TRT IV.82 - Spectral Range 8-14 µm TRT IV.82 after optimazion TRT IV.82 before optimazion 0 10 20 30 40 50 60 Source-/Field stop - Diameter /mm FIGURE 3 SSE diagram SSE DETERMINATION It is recommended to use calibration sources that provide an aperture of 8 mm or more to minimize Size of Source Effects. Functions for correction of SSE are measured for different apertures. The lens of the instrument is designed for a wide spectral range (3 µm to 15 µm). It is a ZnSe meniscus. For calibration the minimum spot size has to be positioned at the opening of the calibration source. A built-in laser-marker is aiming on the center of the field of view. The instrument also provides through the lens sighting The SSE is determined on the instrument before calibration. The incorporated aiming device, a focus laser, is aligned to the measuring field. The arrangement to determine the SSE consists of the following components: Optical rail system Variable aperture (3 60 mm) Deflection mirror Stabilized Black Body Radiator (BBR) (±0.1 C) The BBR is made from a 210 mm x 450 mm aluminum plate with a pyramid structure on the emitting surface. The emitting surface is coated with high temperature paint [Nextel]. The BBR is placed at an angle of approximately 25 to the rail system to avoid multiple reflections between the BBR and the variable aperture. The TRT IV.82 is positioned at a distance of 650 mm to the BBR. Its optical axis is roughly aligned to the rail system using the built-in focus laser. After the rough alignment the aperture is moved to the minimal field of view (FOV) (the actual displacement is usually less than a few tenth of a millimeter in xy-direction and less than 5 mm along the z-axis). The actual measurement is carried out starting with a fully open aperture and recording the radiation values (RAD) for 60 seconds. To eliminate the background (e.g. temperature radiation coming from the aperture) the deflecting mirror is placed between the BBR and the variable aperture. This procedure is repeated several times by reducing the aperture opening down to 3 mm in steps. Then the aperture is removed and the 100 % RAD value is measured The background in this case is determined placing the deflecting mirror directly in front of the TRT IV.82 objective. FIELD OF VIEW The field of view diagram shows the diameter of the measurement area versus the distance from the front edge of the lens (Objective). It is required to use the TRT IV.82 at the focal distance. For this distance the SSE is measured. Field Of View Dia./mm 1000 100 10 1 Field Of View Diagram TRT IV.82 (8µm -14 µm), Lens S977 6.8 mm @ 380 mm 10 100 1000 10000 Distance From Lens / mm FIGURE 4 Field of View Diagram

MEASUREMENT UNCERTAINTY The uncertainties are calculated as described in reference [1], it has been taken according the VTBB calibration scheme [1]. The uncertainty budget incorporates the Blackbodies, the Ambient Conditions, the Radiation Thermometer and the In- Use -Effects like drift. In case of the Radiation Thermometers it incorporated the Size-of-Source- Effect, the Ambient Temperature, the Atmospheric Effect and the NETD. (Conditions see TABLE 2). Calibration was performed on high-grade heatpipe blackbodies of PTB. The radiation temperatures ts,90 at the calibration points from -39 C to 960 C were adjusted by means of standard platinum resistance thermometers, taking into account correction values. For the radiation temperatures ts,90 from 1,200 C to 2,000 C the calibrations were accomplished with the help of the High-Temperature Blackbody (HTBB). The TRT has been photoelectric aligned in front of the blackbodies in the horizontal and vertical plane. The measurement values of calibration were acquired with the aid of the serial interface over a period of approx. 2 minutes for each temperature value. Later, the arithmetic means of the measurement values stored were calculated. The reading of TRT, and the uncertainty stated in TABLE 3 and TABLE 4 are valid for the measurement conditions (TABLE 2). At the moment of calibration, the analysis of the PTB heat-pipe blackbodies furnished the values stated in TABLE 3 and TABLE 4. The uncertainty stated is the expanded uncertainty of the measurement obtained by multiplying the standard uncertainty by the coverage factor k=2. The stated uncertainty considers the uncertainty in the realization of the radiation temperatures of the blackbodies, the realization of the measurement conditions in combination with the SSE of the radiation thermometer and the short term stability of the radiation thermometer under calibration. The uncertainties are valid for the applied measurement conditions. Long term drifts of the instrument are not considered. The uncertainty has been determined in accordance with the "Guide to the Expression of Uncertainty in Measurement". Normally, the value of the measurand lies with a probability of approximately 95 % within the attributed interval of values. The temperature values stated in this calibration certificate are in accordance with the International Temperature Scale of 1990. TABLE 2. Measurement conditions Measurement distance of TRT to the aperture stops: 380 mm Setting of emissivity: 1.000 Setting of response time: 3 s Ambient temperature: 23 C +/- 2 C Relative air humidity: (22 38) % +/- 2 % TABLE 3. Measurement uncertainty TRT IV.82 8-14 µm -50 C 2,000 C Year of Calibration: 2009 Black Body Radiation Uncertainty Aperture Diameter / mm The calibration is done up to 2,000 C and calculated up to 3,000 C. The uncertainties given in TABLE 3 are taken in 2009 [5]. The calibration setup has improved in 2010 which will lead to smaller uncertainties (see TABLE 4) [7]. The uncertainties for the higher temperatures from 1,000 C up to 2,000 C will be taken with the new setup and published later. TABLE 4. Measurement uncertainty TRT IV.82 8-14 µm -50 C 1,000 C Year of Calibration: 2011 Black Body Radiation Uncertainty Aperture Diameter / mm Temperature t s,90 / C Temperature t s,90 / C U / K 20 0.03 0.05 20 350.0 0.3 20 500.0 0.5 20 900.0 0.9 20 1175.4 1.5 20 1509 2.1 20 2005 3.2 U / K 40.0-39.008 0.070 40.0 0.032 0.063 40.0 30.029 0.063 40.0 155.99 0.15 40.0 232.05 0.16 40.0 300.01 0.20 40.0 420.02 0.12 40.0 660.03 0.18 40.0 810.03 0.23 40.0 960.01 0.30

ATHMOSPHERIC EFFECTS The influences of atmospheric effects by humidity were determined by placing the instrument at the working distance of 380 mm from the opening of a BBR, measured through a climatic chamber with variable humidity. Measurements were made from 20 % to 95 % relative humidity. For the 8-14 µm range a small effect was measured that should be corrected. Figure 5 shows the results of these measurements. Functions for correction will be provided with the instrument. Temperature / C 289 288,5 288 287,5 287 286,5 Transfer Radiation Thermometer TRT IV.82 Measured Temperature vs Relative Humidity 286 0 10 20 30 40 50 60 70 80 90 100 Rel. humidity @ 23 C / % FIGURE 5 Effect of humidity for TRT IV.82 (8-14 µm) AMBIENT TEMPERATURE AND WARM UP EFFECTS The effect of ambient temperature variations was investigated by placing the instrument in front of a BBR at a working distance of 380 mm in a climatic chamber. The ambient temperature was changed and the effect was registered. The ambient temperature was determined by the internal reference temperature of the TRT IV.82 (Figure 7). The effect is within the instrument compensated by calculation. Tem peratur / C 1,001.75 1,001.70 1,001.65 1,001.60 1,001.55 1,001.50 Transfer Radiation Thermometer TRT IV.82 Effect of Ambient Temperatur 1,001.45 10 15 20 25 30 35 TRT IV Internal Reference Temperature / C FIGURE 7. Effect of ambient temperature Figure 8 shows the warm up effect in measuring operation. The temperature drift of the TRT IV.82 is recorded versus time while the instrument was continuously viewing at a 1,000 C source at 380 mm distance. Tem peratur / C 1,001.75 1,001.70 1,001.65 1,001.60 1,001.55 1,001.50 Transfer Radiation Thermometer TRT IV.82 Effect of Measuring Time 1,001.45 0:00 0:30 1:00 1:30 2:00 2:30 3:00 Measuring Time /h:min FIGURE 8. Effect of time in front of a Black body

TECHNICAL SPECIFICATION Table 5 Technical Specification of TRT IV.82 Value TRT IV.82 (8-14 µm) Temperature 0 C 3,000 C measuring ranges -50 C 2,000 C -50 C 1,200 C -50 C 1,000 C Spectral response 8-14 µm Field of view 6.8 @ 380 mm Measuring field Laser marker and throughthe-lens-sighting marking Lens S977 (Zinc Selenide) Detector Analog output (selectable by programming) Resolution of the analog output Digital interface (RS232C) Resolution of serial output Response time (90%) (selectable by programming) Uncertainty Pyroelectric 0... 20 ma, 4... 20 ma, 0... 1 V, 0... 10 V The output signal is linear to the measured temperature or linear to the measured radiation, depends on setting 12 bit 9,600-115,200 bps 0.010 C 0.05; 0.10; 0.03, 0.1, 0.3, 1, 3 and 10 s Given by calibration laboratory 23 C ± 3 C Permissible ambient temperature Storage temperature - 20... + 70 C Operating voltages 24 VAC +/- 10 %, 48-400 Hz, 22-30VDC Power requirements Housing dimensions Weight Type of protection 200 ma RMS See above 1.5 kg IP65 (NEMA4 equivalent) CONCLUSION HEITRONICS has improved the performances of the TSRT and designed the TRT IV.82, an advanced, commercially available instrument which is suitable to be used as a Transfer Radiation Thermometer up to 3,000 C on long wavelength (8 14 µm). It provides high stability and excellent temperature resolution for calibrations at Calibration Laboratories as well as on industrial level. The instrument has to be calibrated against high grade Radiation Sources. It can be used in the VTBB scheme. It combines the benefits in handling and features of an industrial infrared thermometer with the performance of a TRT. ACKNOWLEDGEMENTS The author thanks all participants to their contributions to specify, evaluate and improve the performance of the TRT instruments. Special thanks to the PTB for spending the time and efforts to characterize features of the TRT [6]. REFERENCES 1. P. Saunders et al. Uncertainty Budgets for Calibration of Radiation thermometers below the Silver Point, International Journal of Thermophysics, (2008) 29: 1066-1083 2. Yong Shim Yoo, Bong-Hak Kim, Chu-Woung Park, Dong-Hoon Lee and Seung- Nam Park, Size of source effect of a transfer reference thermometer suitable for international comparisons near to room temperature in XIX IMEKO World Congress;Fundamental and Applied Metrology, September 6-11, 2009 3. O. Struß, C. Staniewicz, TEMPERATURE: Its Measurement and Control in Science and Industry; Volume VII, Eighth Temperature Symposium. AIP Conference Proceedings, Volume 684, pp. 565-570 (2003). 4. P. Bloembergen, M. Batuello, R. Bosma, J. Fischer, B. Gutschwager, E.W.M. van der Ham, G. Machin, H. McEvoy, T.Ricolfi, P. Ridoux, M. Sadli, TRIRAT, Second Progress Report, 1999 5. J. Hollandt, B. Gutschwager, Physikalisch-Technische Bundesanstalt PTB, Calibration certificate for Transfer Radiation Thermometer, 2009 6. F.E.Liebmann, et al. Radiometric comparison between a national laboratory and an industrial laboratory, Simposio de Metrologia, 2010 7. J. Hollandt, B. Gutschwager, Physikalisch-Technische Bundesanstalt PTB, Calibration certificate for Transfer Radiation Thermometer, 2011