SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Similar documents
SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

FREEDM Loose Tube Interlocking Armored Cables

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Micro duct Cable with HDPE Sheath for Installation by Blowing

Mining and Petrochemical Fiber Optic Cables

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F Ribbon Indoor/Outdoor Riser Cable Preparation

Number of Fiber 6 Core 12 Core 24 Core 48 Core

TECHNICAL SPECIFICATION

SOLO ADSS Short-Span Cables, Fibers

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Product Catalogue. Fibre Optic Cable

Number of Fiber 6 Core 12 Core. Part Number

SPECIFICATION. Optical Fiber Cable

1. General. 1. Scope. 2. Quality Assurance

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

Empowering businesses through innovative network solutions.

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

LD Series High Performance Loose Tube Fiberoptic Cables

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

Revision No. 4 Page No. Page 1 of 7

Cable installation guidelines

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

Mini-breakout & Mini-bundle cable. Riser cabling solution

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Public Works Division Lighting District Fiber Optic Specifications April 2009

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

SPECIFICATION. Spec No : VSS-1402-CS603B

Purchase Now ANSI/ICEA S

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

OPTICAL CABLE FIBER-LAN INDOOR

INDUSTRY SOLUTIONS: MINING

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

The FiberMark1 offers an ideal solution for

FusionLink Central Tube Ribbon Preparation & handling procedure

New Ultra-Density Fiber Cable Technology for FTTx and Access Markets Using New SpiderWeb Ribbon

TECHNICAL SPECIFICATION

INSTALLATION INSTRUCTIONS

Industry solutions: Broadcast

OPTICAL FIBRE CABLE NETWORK 2004/1

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

SECTION FIBER OPTIC STATION CABLES

Special Specification 6242 Special Fiber Optic Cable

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

1 1/2 13.5, 625 JCASS)

Section Communications Optical Fiber Backbone Cabling

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

ENGINEERING COMMITTEE Interface Practices Subcommittee. ANSI/SCTE (Formerly IPS SP 001)

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet

DOME OPTIC SPLICE CLOSURE

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

NOTICE. The above identified patent application is available for licensing. Requests for information should be addressed to:

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Customer-Owned Outside Plant

Optical Distribution Box 300 Installation Guide. Version : R0.0

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Instrumentation Cables

Cable Installation Tips

Selecting the correct cable type for Outside Plant Application

Underground Installation of Optical Fiber Cable by Pulling

Student Services & Classroom Addition

Installation of Solo ADSS All-Dielectric Self-Supporting Fiber Optic Cables

Fiber Optic Closure. Fiber Optic Splice Closure For Aerial Line. Model : W-ICL-007-xxF. Features

FIBRE OPTIC CABLE SOLUTIONS

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SPECIAL SPECIFICATION 6559 Telecommunication Cable

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Transcription:

SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100 or 1-800-358-7378 www.futureflex.com SEL is a Member of the Sumitomo Electric Industries, Ltd. Group Sumitomo Electric Lightwave reserves the right to improve or modify these specifications without notice. TCxxMSOS DIELECTRIC OSP TUBE CABLE SERIES Page 1

CONTENTS 1.0 GENERAL 1.1 Tube cable Description 3 1.2 Quality 3 1.3 Reliability 3 2.0 Tube Cable Design 2.1 General 4 2.2 Construction 4-6 3.0 Tube Cable Characteristics 7 3.1 Performance 7 3.2 Tube and Jacket Markings 7 3.3 Reel Markings 7 3.4 Tube cable Ends 7 3.5 Tube Cable Reel Data 7-8 4.0 Testing 8 5.0 Installation / Handling Practices 8 6.0 Ordering Information 8 TCxxMSOS DIELECTRIC OSP TUBE CABLE SERIES Page 2

1.0 GENERAL This specification covers the design requirements and performance standards for FutureFLEX Air-Blown Fiber (ABF) dielectric, UV resistant low shrink outside plant tube cables. These tube cables are designed for outdoor tube cable infrastructures. The features described in this document are intended to provide information on the performance of Sumitomo Electric s FutureFLEX tubes and aid in handling and use. 1.1 Tube Cable Description Sumitomo s FutureFLEX MSOS series tube cables are designed for use as an optical fiber cabling infrastructure in ABF applications that require non-conductive elements. The MSOS series tube cables are ideal for aerial or duct installations, and all OSP applications that require enhanced thermal stability. They may also be used in indoor applications where: 1) the tube cable is installed in rigid steel conduit or 2) no fire ratings apply. The tubes are made of a high performance black HDPE and have a 6mm inside diameter and 8mm outside diameter. The tubes are wrapped with a non-conductive water-blocking tape. The outer jackets are made of a high performance black HDPE with four extruded linear yellow stripes set at 90º apart. A ripcord is provided to aid in outer jacket removal. These tube cables are pulled or placed in routes for the purpose of individual tube connections to establish pathways for FutureFLEX fiber bundle installation. 1.2 Quality Sumitomo ensures a continuing high level of quality through ISO / TL9000 registered Quality Management Systems and our commitment to continuous improvement. Guaranteed, high quality products have been manufactured at Sumitomo s facility in Research Triangle Park, North Carolina since 1984. 1.3 Reliability Sumitomo ensures product reliability through rigorous qualification testing of each product family to meet or exceed industry standards. Both initial and periodic qualification testing are performed to assure the tube cables performance and durability in a field environment. Sumitomo supports industry standards organizations such as Telcordia, Telecommunications Industry Association (TIA), International Telecommunications Union (ITU), International Electrotechnical Commission (IEC), American Society for Testing and Materials (ASTM), Rural Utilities Service (RUS), The Institute of Electrical and Electronics Engineers (IEEE), and Insulated Cable Engineers Association (ICEA). TCxxMSOS DIELECTRIC OSP TUBE CABLE SERIES Page 3

2.0 TUBE CABLE DESIGN 2.1 General Sumitomo s FutureFLEX MSOS series tube cables provide a small diameter, lightweight, outdoor pathway for FutureFLEX fiber bundle installations. FutureFLEX ABF fiber bundles are available in Single-mode OS1, 62.5 micron Multimode OM1, 1-Gigabit 50 micron Multimode OM2, Laser Optimized 10-Gigabit 50 micron Multimode OM3, and Laser Optimized 10-Gigabit 50 micron Multimode OM4 versions with 2, 4, 6, 12, 18, or 24 fiber strand counts. One fiber bundle can be field-installed in each tube. 2.2 Construction SEL Part Number TC02MSOS TC04MSOS TC07MSOS TC19MSOS Product Description 2- high performance tubes, wrapped with water-blocking tape, ripcord, and black high performance polyethylene outer jacket with 4 yellow stripes 4- high performance tubes, around a FRP central strength member, wrapped with waterblocking tape, ripcord, and black high performance polyethylene outer jacket with 4 yellow stripes 7- high performance tubes, wrapped with water-blocking tape, ripcord, and black high performance polyethylene outer jacket with 4 yellow stripes 19- high performance tubes, wrapped with water-blocking tape, ripcord, and black high performance polyethylene outer jacket with 4 yellow stripes Outside Diameter (in.) Max. Weight (lbs./kft.) Max. Tensile Load (lbs.) 0.9 89 200 0.9 141 200 with standard basket-weave grip or 500 with pulling eye 1.1 196 400 1.77 399 600 TCxxMSOS DIELECTRIC OSP TUBE CABLE SERIES Page 4

1 Black Tube Water Blocking Tape Ripcord Outer Jacket 2 2-Tube Dielectric Low Shrink OSP Cable TC02MSOS Drawing Not to Scale 1 4 2 3 Black Tube Water Blocking Tape Central Strength Member Ripcord Outer Jacket 4-Tube Dielectric Low Shrink OSP Cable TC04MSOS Drawing Not to Scale TCxxMSOS DIELECTRIC OSP TUBE CABLE SERIES Page 5

1 6 5 7 2 3 Black Tube Ripcord Water Blocking Tape Outer Jacket 4 7-Tube Dielectric Low Shrink OSP Cable TC07MSOS Drawing Not to Scale 1 12 2 11 13 3 Black Tube 18 14 Ripcord 10 17 19 15 4 Water Blocking Tape 9 16 5 Outer Jacket 8 6 7 19-Tube Dielectric Low Shrink OSP Cable TC19MSOS Drawing Not to Scale TCxxMSOS DIELECTRIC OSP TUBE CABLE SERIES Page 6

3.0 TUBE CABLE CHARACTERISTICS 3.1 Performance Property Operation Temperature Range Minimum Bend Radius (During / After Installation) Specification -65 to +158 F 20 / 10 x tube cable outside diameter 3.2 Tube and Jacket Markings The outside surface of each tube is marked every two (2) inches with the tube designation number. (1 through 19) The outside surface of each jacketed cable is marked every two (2) feet with the following information: Phone Receiver SEL FutureFLEX (SEL Part No.) (#)-Tube Dielectric OSP Optical Fiber Cable, A-(Lot #-1, -2, -3, etc.) (Seq. Ftg.) 1-877-356-FLEX WWW.FUTUREFLEX.COM 3.3 Reel Markings The outside of each flange is marked with the Sumitomo Electric Lightwave Corp. product part number, the tube cable manufactured length in feet, and the text Do Not Lay Flat. 3.4 Tube Cable Ends Both ends of the tube cable are accessible on the reel. Each tube is sealed with a plastic cap or plug. Tube cable ends are sealed with a heat shrink end cap. 3.5 Tube Cable Reel Data Sumitomo Part No. Reel Length (ft) Reel F x W (in) Minimum Drum Diameter (in) Reel Weight (lbs) Empty Reel Weight (lbs) Full TC02MSOS 1000 54 x 20 40 116 205 TC02MSOS 3000 60 x 49 40 420 686 TC04MSOS 1000 54 x 20 40 116 257 TC04MSOS 3000 60 x 49 40 420 842 TC07MSOS 1000 54 x 36 40 137 333 TC07MSOS 3000 60 x 49 40 420 1008 TC19MSOS 1000 60 x 49 40 420 819 TC19MSOS 2500 72 x 49 40 523 1521 TC19MSOS 3000 72 x 52 36 543 1740 TCxxMSOS DIELECTRIC OSP TUBE CABLE SERIES Page 7

Notes: Standard Reel Lengths are 1,000-feet and Maximum Reel Lengths are 3,000-feet unless otherwise noted. All Reel Length tolerances are +5%. Cut Lengths are available. Contact FutureFLEX Distributor for additional information. If tube cable is re-spooled, the minimum Drum Diameter of the new reel SHALL be no less than that specified herein to avoid damaging tube cable product. All Reel Widths shown are approximate values only and measured from outside-of-flange to outsideof-flange plus an allowance for fastener hardware protrusions. All Empty and Full Reel Weights shown are approximate values only. 4.0 TESTING Each finished tube cable is required to pass a 5mm diameter steel ball from end to end using 70 psi (+/- 10 psi) gas pressure. 5.0 INSTALLATION / HANDLING PRACTICES Sumitomo has incorporated a wide range of technical support and training services for our tube cable products into our Technical Support Services (TSS) program. TSS offers training in the areas of cable installation, sheath entry, splicing, testing, and system troubleshooting. The services are available in a variety of media formats and can be customized to better accommodate individual training needs. The TSS program consists of an extensive series of recommended procedure documents, training courses with classroom and hands-on instruction. Please contact Sumitomo s Customer Service department for more information. 6.0 ORDERING INFORMATION To learn more about Sumitomo s cables or to place an order, call, fax, e-mail, or write us at: SUMITOMO ELECTRIC LIGHTWAVE CORPORATION 201 South Rogers Lane Suite 100 Raleigh, NC 27610 Attn: Customer Service Department Phone: 800-358-7378 919-541-8100 Fax: 919-541-82265 E-mail: info@sumitomoelectric.com Sumitomo Electric Lightwave reserves the right to improve, enhance, or modify the cable s features and specifications. For special requirements different than those shown above, please contact our Inside Sales Department. Each Sumitomo Electric Lightwave Corp. optic cable and/or its manufacture may be covered by one or more of the following US Patents: 4,715,677 4,729,629 4,763,983 4,770,489 4,828,349 4,953,945 5,043,037 5,082,347 5,165,003 D331,567 TCxxMSOS DIELECTRIC OSP TUBE CABLE SERIES Page 8