Page 1 of 7 Preselection and multifunction up/down counters 48x48 - CPT4 - Electronic multifunction counters CPT4 - LCD - 6 x 9 mm digits Selling points of the range Preselection counter, Tachometer, Timer, Multi-totalizer, Batch counter Convenient parameter-setting options: configuration using text menus Easy modification of presets and multiplication coefficient Changeover relay and solid state output LCD display with 6 digits, 9 mm high LED display with 6 digits, 7.6 mm high IP65 sealed front panel Possibility of selective, complete or partial keyboard locking (preset, gain and/or reset) Part number characteristics 87620111 Function Preselection counter/tachometer/timer/multitotalizer Preset 1 Supply voltage 12-24 V DC Output 1 changeover 1 solid state Product available stocked item General characteristics Physical details and protection Supply Relative humidity (no condensation) Altitude Standards Vibration resistance in 3 axes Connection by screw terminals Protection Front panel watertight seal Temperature limits use Temperature limits stored Weight General characteristics Reset to zero or to preset Option to protect against reset from front panel Minimum pulse time Version 12 < 24 V DC ± 10% Version 24 V AC ± 10% Version 115 V AC ± 10% Version 230 V AC ± 10% DIN 40040-40/92 C / % RLF 0 < 2000 m/3048 m (transport) UL - culus - CE 10 m/s 2 (10 150 Hz) conforming to IEC/EN 68-part 2-6 100 m/s 2 (18 ms) conforming to IEC/EN 68-part 2-27 Conforming to IEC 144 IP 65 on front panel IP 20 for the connections 0 50 C Scale factor (each input pulse is multiplied by this figure) Decimal point selectable for ease of reading Sensor supply only when AC operated Programming and current value backed up via EEPROM memory -20 +70 C Approx. 100 g for V DC version with 1 preset Approx. 200 g for all other versions On front panel if not locked during programming Electrical: automatic, voltage or solid state (NPr PNP depending on programming) Counting input: 17 ms 30 Hz 250 µs 2.5 KHz 100 µs 5 KHz 0.001 999 999 xxxxxx xxxxx,x xxxxx,xx xxx,xxx 12 < 30 V DC, max. load 50 ma By non-volatile memory Write cycle: >100.000 Read cycle: unlimited Service life more than 10 years Operating characteristics Preselection counter Tachometer Functions Timer Multi-totalizer Batch counter Number of presets 1 or 2 Display LCD or LED LCD < 9 mm Height of digits LED < 7.6 mm Display details -99 999 < 999 999 Inputs specifications 2 counter inputs
Page 2 of 7 Input Input modes Input type High level Low level Solid state output characteristics Maximum current Maximum voltage Relay output characteristics Changeover relay 1 gate and reset input Adding Subtracting Directional Cumulative Independent Phase Voltage or solid state >= 8 V DC 40 V DC <= 2 V DC 30 ma 24 V DC for DC powered version 30 V DC for AC powered version Maximum current 5 A Rated current 10 ma Maximum voltage 30 V DC / 250 V AC Min. voltage 5 V AC/DC Response time <5 ms Mechanical life (operations) 1.00 E + 07 Permitted number of operations at 5 A AC1 1.00 E + 05 Output modes: maintained or pulsed 20, 50, 100, 200, 500 ms or 1s Counting speed Counter 5 khz for simple counting 2.5 khz for counting on both inputs Dimensions CPT4 1 Panel thickness 1 < 10 mm Panel cut-out Panel cut-out adaptor plate 72 x 72 1 Front frame 2 Seal 3 Clamping frame Accessories Accessories Code Panel cut-out adaptor plate 72 x 72 87 620 300 Curves Counter input Simple counting - In CGr
Page 3 of 7 : Counter 2 Input B: Gate Directional counting - In CdG : Counter 2 Input B: Counting direction 3 Input C: Gate Directional counting - In Cdr : Counter 2 Input B: Counting direction Individual counting - In ASr : Upcounter 2 Input B: Downcounter Individual counting - In ASG : Upcounter 2 Input B: Downcounter 3 Input C: Gate Cumulative counting - In AAr : Counter 2 Input B: Counter Phase discriminator - In PPr : Channel A 2 Input B: Channel B Phase discriminator - In PPG
Page 4 of 7 : Channel A 2 Input B: Channel B 3 Input C: Gate Output mode Counting in the direction of the cycle - rs 0/rS A0 1 Counting 2 Reset* Counting in the opposite direction to the cycle - rs P2/rS AP2 1 Counting (Eg: P2 = 8) 2 Reset* Reset Solid state reset - rs blo 1 Counting 2 Reset Dynamic reset - rs cpt 1 Counting 2 Reset Timing mode Accumulated time duration while input A is active Accumulative time duration between 2 rising edges on A
Page 5 of 7 Time duration while input A is active Time duration between 2 rising edges Tachometer operating mode 1 Low threshold 2 Normal operation 3 High threshold Batch counter operating mode 1 Current counter 2 Batch counter 3 Reset Connections
Page 6 of 7 CPT4-2 presets in AC version CPT4-2 presets in DC version 1 V AC power supply 2 Solid state output 2 3 Relay output 2 4 Auxiliary power supply 5 0 V or common 6 Counter and control input 7 Solid state output 1 8 Relay output 1 1 NC: Not connected 2 Solid state output 2 3 Relay output 2 4 V DC positive input 5 0 V or common 6 Counter and control input 7 Solid state output 1 8 Relay output 1 Applications Length let-off check 1 Encoder 2 Slow-down 3 Stop 4 Moteur 5 Ralentissement Compteurs à présélections Contrôle de déroulement de longueur 1 Codeur 2 Ralentissement 3 Stop Compteurs à présélections Contrôle de remplissage 1 Distribution 2 Vanne de remplissage rapide 3 Vanne de remplissage lent Totalisateurs d'impulsions / horaires Comptage de pièces 1 Cellule photoélectrique
Page 7 of 7 Totalisateurs d'impulsions / horaires Affichage de la logueur déroulée 1 Détecteur inductif Tachymètres Affichage de débit Tachymètres Affichage de la vitesse 1 Moteur 2 Détecteur inductif Tachymètres Affichage du nombre de bouteilles ou de la cadence de la chaîne de remplissage 1 Cellule photoélectrique