Sauter Components

Similar documents
51.377/1. AVM 234S: Valve drive with SUT positioner. Sauter Components

Product Data Sheet

PROPORTIONAL VALVES Sentronic plus

Mechanical flow switch for On/Off control

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Long Stroke and High-Speed Movement

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Ordering details. Approval. Classification

Cylindrical Photoelectric Sensor CY-100 SERIES

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LED control gear Compact fixed output

Absolute Rotary Encoder E6CP

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Technical data. General specifications. Indicators/operating means

Generator protection relay

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Wall-/Pipe-Mount Level Indicator

Liner Quattro AC XB RGBW

Actuators IC 20, IC 40

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Connecting cables for valves, Sub-D Type codes

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

DLP200M 2 Relay Module for Heating and Cooling Plants

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

LED Driver Compact fixed output

LED Driver Linear / area fixed output

02/11/2015

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Datasheet - SRB301LC 24VAC/DC

Absolute encoders multiturn

SAUTER flexotron RDT405 Manual

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Photoelectrics Through-beam Type PA18C.T..., DC

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Data Sheet GU-LCT-RY-V1-10 GU-LCT-RY-V1-11

Linear flow control with actuator IFC

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

U S E R M A N U A L. HDMI Splitter 1x4. Model No:HDSP0001M1

LED Driver Compact fixed output

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Datasheet - SRB-E-201ST

RKSlimlift / EM. Two-stage lifting column

General Specifications

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Inductive sensor BI1.5-EG08K-Y1

LED Driver Compact fixed output

SQM40/41 Actuators for air and gas dampers

Inductive sensor NI3-EG08K-Y1-H1341

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Inductive sensor With analog output BI15-M30-LI-EXI

DALI TOUCHPANEL BASIC TW. Operating and control unit

Installing the FOREST SHUTTLE S / L

Standard RS232 RS ma

Connecting cables for valves, round plug connectors Product range overview

MULTIMIX 8/4 DIGITAL AUDIO-PROCESSING

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Gamma instabus. Technical product information

Compact EGC Fiber Deep Nodes A90100 and A90300

Process Transmitter RMA 422

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

AS09..S 3-pole Contactors - Spring Terminals

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

8 Installation Equipment

LONWORKS Fibre Optic Converter

Sensor technologies Proximity sensors Series ST4. Brochure

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

OxLinx TM LHM-Pxxx. Classification : Technical Specification. Ⅰ. Preview. Ⅱ. Contents. Spec. No. AD K Date

High performance circuit breakers

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

GESTRA Steam Systems NRR 2-50 NRR English. Installation & Operating Manual Level Controller NRR 2-50 Level Controller NRR 2-51

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

DLP600M 6+1 Relay Module for Heating and Cooling Plants

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Tube Rotator. User Guide. Version 1.2

ABS ST700 Compact Type Series

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Process transmitter RMA422

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Transcription:

51.362/1 AVM 105S, 115S: Actuator with SAUTER Uniersal Technology (SUT) How energy efficiency is improed Automatic adaptation to ale, precision control and high energy efficiency with minimal operating noise. Areas of application Actuation of through and three-way ales of the VUN/BUN, VUD/BUD and VUE/BUE series (DN15 to DN50). For controllers with continuous output (0 10 V) or switching output (2-point or 3-point control). Features Pushing force 250 N (AVM 105S) or 500 N (AVM 115S) Stepping motor with SUT (SAUTER Uniersal Technology) electronic control unit and electronic load-dependent cut-off Automatic detection of control signal applied (continuous or switching) The type of characteristic cure (ear, quadratic or equal percentage) can be set in the actuator Independent adaptation to ale stroke Direction of trael can be set on cable Coding switch for selection of characteristic and running time (35, 60 or 120 s) Maintenance-free transmission with magnetic clutch Transmission can be disengaged for positioning the ale manually (Allen key included) Assembly with ale is done automatically after control oltage is applied Technical description 24 V~ or 24 V~/= power supply Two-part housing made of fire-retardant plastic; lower section black, upper section yellow Console made of glass-fibre-reinforced plastic Brass box nut for fitting ale Connecting cable 1.2 m long, 5 0.75 mm² Installation position: ertical to horizontal, but not upside down Type Running time [s] 2) [mm] Pushing force [N] Power Weight [kg] For ales with equal-percentage characteristic, can be switched oer to ear AVM 105S F132 35/60/120 8.0 250 24 V~/= 0.7 AVM 115S F132 60/120 8.0 500 24 V~/= 0.7 100 % M Y07552 Direction of operation 2 Direction of operation 1 0 % 0 V Output signal y 10 V B07650 Positioner 1) Control signal 0...10 V, Ri > 100 k Starting point U 0 0 or 10 V Positional feedback signal 0...10 V, load > 10 k Control span U 10 V Switching range X sh 200 mv Power supply 24 V ± 20%, 50/60 Hz Degree of protection IP 54 as per EN 60529 24V= +20% / 10% (horizontal) Power consumption Protection class III as per IEC 60730 AVM 105S F132 4.8 W 8.5 VA Response time 1) 200 ms AVM 115S F132 4.9 W 8.7 VA Wiring diagram A09673 Max. media temperature 100 C Dimension drawing M09743 Ambient temperature 10...55 C Ambient humidity 5 95% rh Fitting instructions 1. 5S MV 506065 without condensation Material declaration MD 51.362 For control ale type KTM512 / TA-Regulator DN 15 50 Type Running time [s] [mm[ Pushing force [N] Power Weight [kg] AVM 115S F901 80/160 10.0 500 24 V~ 0.7 Deiation from standard type: inerse scale therefore inerse direction of operation. Adaptor for control ale aailable on the ale or from TA-Regulator, stating reference no. 52 757 003. 1) Also for 2-point or 3-point, depending on type of connection 2) Maximum stroke of drie = 10.0 mm

51.362/2 AVM 105S...115S Accessories 0313529 001* Split-range unit for setting sequences; to be fitted in separate distribution box as per MV 505671 0372145 001* Single auxiliary change-oer contacts 1) ; MV 505795 0372145 002* Double auxiliary change-oer contacts 1) ; MV 505795 0372249 001* Intermediate piece required for media temperature >100 C (recommended for temperature < 10 C); MV 505932 0372273 001* Adaptor for Siemens VVG/VXG 44 and 48 ales; MV 505848 0372286 001 Potentiometer 2) 130 ; MV 505795 0372286 002 Potentiometer 2) 1000 ; MV 505795 0372286 003 Potentiometer 2) 5000 ; MV 505795 0372462 001 CASE Dries PC tool for configuration of actuators per computer; MV 506101 *) Dimension drawing or wiring diagram is aailable under the same number 1) Fully ariable from 0...100%; max. loading 5 (2) A. 24...230 V 2) ly one potentiometer or one set of auxiliary contacts can be fitted to each drie Operation Depending on how it is connected (see wiring diagram), the actuator can be used as a continuous 0...10 V, a 2-point (open/close) or a 3-point (open/stop/close) drie with intermediate position. The running time can be matched to requirements using switches S1 and S2 (AVM 105, S1 only). The characteristic (equal-percentage or ear) can be selected using switch S3. The AVM 105/115 is combined with ales that hae an equal-percentage basic characteristic such as the VUD/BUD and VUE/BUE ales. The AVM 115 can be fitted to a ale with a ear characteristic (e.g. VUE 050F200), but the position of the coding switches is important. With the AVM 105, it is not possible to create an equal-percentage characteristic for a ale with a ear characteristic. Manual adjustment is performed by disengaging the transmission (sliding switch next to the power cable) and simultaneously turning, using an Allen key in the insert on the upper part of the drie. 8 mm of stroke is attained with 1½ turns. N.B.: After manual adjustment, re-set the sliding switch (engage the transmission). Connected as a 2-point actuator Open/close actiation can be effected ia two wires. Power is applied to the drie ia the blue and the brown wires. connecting power to the black wire, the ale s control passage opens. When power is switched off, the drie goes to the opposite end position and closes the ale. The unused red and grey wires should not be connected, nor should they come into contact with other wires. We recommend that you insulate them. Connected as a 3-point control unit By connecting power to the wires (brown or black), the ale can be moed to any position. The coupg rod extends and opens the ale if power is applied to the black wire. It retracts and closes the ale if power is applied to the blue and the brown wires. In the end positions (on hitting a stop in the ale or reaching the maximum stroke) or in the eent of an oerload, the electronic motor cut-off responds (no end switches). The direction of the stroke can be changed by swapping the power-supply wires oer (BN/BK). The unused red and grey wires should not be connected, nor should they come into contact with other wires. We recommend that you insulate them. Connections for control oltage 0...10 V The integrated positioner controls the drie as a function of the controller s positioning signal y. Direction of operation 1 (mains power on brown wire): the coupg rod extends and opens the ale (control passage) as the positioning signal rises. Direction of operation 2 (mains power on black wire): the coupg rod retracts and closes the ale (control passage) as the positioning signal rises. The starting point and the control span are both permanently set. There is a split-range unit aailable (as an accessory) for setting partial ranges. After manual adjustment or in the eent of a power failure for longer than 5 minutes, the drie re-adjusts itself automatically, always with the following running times: AVM 105 35 s AVM 115 60 s

AVM 105S...115S 51.362/3 After power has been applied, the stepping motor moes to the lower stop, connects to the ale spindle and moes to the upper stop in the ale, thereby determining the closed position. Depending on the control oltage, any stroke between 0 and 8 mm can then be obtained. Thanks to the electronics unit, no steps can be lost, and the drie needs no periodical re-adjustment. Parallel operation of more than one drie of the same type is guaranteed. The feedback signal y 0 = 0...10 V corresponds to the effectie stroke of 0 to 8 mm. If the control signal (0...10 V) is interrupted and direction of operation 1 is connected, the ale closes fully (0% position). The ale s characteristic can be selected using the coding switch. The characteristics can be generated only if the drie is used as a continuous drie. Other switches enable the running times to be set. These can be applied irrespectie of which function (2-point, 3-point or continuous) has been chosen. Coding switch for setting the running time AVM 105S AVM 115S Run time per mm Switch coding 7,5 s 60 s ± 2 Run time for 8 mm stroke 15 s 120 s ± 4 = factory setting B10703 Coding switch for selecting the characteristic AVM 105S Desired character. cure Equal percentage Switch coding cure for ale cure for drie Effectie on ale = % Linear Linear = factory setting B10704

51.362/4 AVM 105S...115S Coding switch for selecting the characteristic AVM 115S Desired character. cure Switch coding cure for ale cure for drie Effectie on ale Equal percentage = % Quadratic x 2 Linear Equal percentage = % Linear = factory setting B10705 Split-range unit, accessory 0361529 001 The starting point U0 and the control span U can be set using the potentiometer. This makes it possible to actiate seeral regulating units in sequence or in cascade using the controller s control signal. The input signal (partial range) is amplified into an output signal of 0...10 V. This accessory cannot be fitted in the actuator, but should be located externally in an electric distribution box. CASE Dries PC tool, accessory 0372462 001 CASE Dries enables all the actuator's parameters to be set and iewed on site. Connection is ia a serial port on the PC (laptop) and a socket on the actuator. The set comprises: software including installation and operating instruction, fitting instructions, connectors, cable (1.2 metres in length) and an interface conerter for the PC. The application is designed for commissioning/ serice technicians and for experienced users. The last setting (i.e. whether with coding switch or CASE Dries) has priority. This setting is actie when the ale's running time or characteristic is changed ia the coding switch. To ensure that the settings with CASE Dries cannot be oerwritten, the coding switch should be remoed before setting alues through CASE Dries (special tool included).

AVM 105S...115S 51.362/5 Engineering and fitting notes The ingress of condensate, drops of water etc. along the ale spindle and into the drie should be preented. With the electrical connection, you must also make sure that the cross-section of the supply e is adapted to the power and length. In any case, howeer, we recommend that the cross-section should not be less than a minimum of 0.75 mm 2. The assembly of actuator and ale is done by fitting and tightening the cap nut without further adjustment; no tools should be used. The ale spindle and the drie spindle are coupled together automatically, either by using the manual adjustment facility or by applying power. When dismantg, first release the drie/ale spindle, then loosen the cap nut. The actuator is supplied ex works in the middle position. The combination of stepping motor and electronics unit allows seeral actuators of the same SUT type to be run in parallel. The following accessories can be fitted to each actuator: one set of auxiliary contacts. The coding switches are accessible ia an opening with black lid in the housing coer. The auxiliary contacts should be screwed onto the drie s top coer. Before the mechanical connection can be established, the indicator knob should be remoed. A new indicator is then isible on the lid of the auxiliary contacts. N.B.: The housing should not be opened. Fitting outdoors If the deices are fitted outdoors, we recommend that additional measures be taken to protect them against the effects of the weather. Additional technical data The upper part of the housing, with the lid, indicator knob and the cap, contains the stepping motor and the SUT electronic control unit. The lower part contains the maintenance-free transmission. Auxiliary change-oer contacts Switch rating: max. 230 V a.c.; min. current 20 ma at 20 V Switch rating: max. 4...30 V d.c.; current 1...100 ma Power consumption: Type Running time [s] Condition Actie power P [W] AVM 105S F132 35 Operating 2.45 4.75 Standstill 0.35 0.8 60 Operating 4.8 8.5 Standstill 0.35 0.8 120 Operating 2.2 4.25 Standstill 0.35 0.8 AVM 115S F132 60 Operating 4.9 8.7 Standstill 0.35 0.75 120 Operating 2.25 4.3 Standstill 0.35 0.75 CE conformity EMC Directie 2004/108/EC EN 61000-6-1 EN 61000-6-3 EN 61000-6-4 Apparent power S [VA]

51.362/6 AVM 105S...115S Wiring diagram RD = red BN = brown BK = black BU = blue GY = grey A10450 Dimension drawing 372145, 372286 0372249 001 Ø33 Ø8 45,6 63 43,5 107,1 60 55,8 5 15 3,2 10 32 2,5 35 Ø42 Ø16 Z10214 122 126,7 372273 46,5 70 2,5 3,2 Ø8 Ø26,5 SW30 Ø33 Ø26,7 Ø33 23,5 15,5 M09743b 10 10 4 8 24 M10203 Accessories 372145 001 372145 002 RD BN BK RD BN BK GN GY VT MM 01/02 03 A09782 A10183 Printed in Switzerland Subject to change. Fr. Sauter AG. CH-4016 Basle