Similar documents
Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

8 Installation Equipment

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Pendant Light Fitting IEC Series 6470/2

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

EXPlora. Introduction

Circuit-Breakers for Motor Protection Series 8523/8

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Horn loudspeaker, Ex proof, short/long flare

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

Explosion Proof Audible Signal db(a) Series YA60

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

I Ex-protected connectors exlink I

TYPE APPROVAL CERTIFICATE

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Pendant Light Fittings Series 6050

Inductive sensor With analog output BI15-M30-LI-EXI

Pressure transmitter For applications in hazardous areas Model IS-3

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Motor Protection Circuit Breaker Series 8146/5-V27

PMG. Vibration Energy Harvesters

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

7 Lighting Technology

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

EXLUX ECOLUX 6480 Series

Modular Lube Lubrication Systems System Controls

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

EXLUX ECOLUX C-LUX 6480 Series

TFRN Industrial RTD temperature sensor. CombiTemp TM

ABB IEC International Pin and Sleeve

Explosion Proof Audible Signal db(a) Series YA60

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Inductive sensor NI3-EG08K-Y1-H1341

Magnecraft Power Relays

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Level Measurement Point level measurement - RF Capacitance switches

Magnetic and Hydraulic-Magnetic Circuit Breaker

Illustrated Feature. Options

TFRN Industrial RTD temperature sensor. CombiTemp TM

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

High performance circuit breakers

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Bulletin 190 IEC Modular Starter System

Operating instructions

Quality products from a single source

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

DMP 331i / DMP 333i LMP 331 i

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Sensor technologies Proximity sensors Series ST4. Brochure

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil


LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

Certificate No.: i IECEx SIR issue No.:1 9.!~~~t~I~t.CJ!y:... Issue No.1 ( ) Status;

Process Transmitter RMA 422

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

3 Cleaning. 4 Technical data

llen-bradley 194R-HM4-NFPA3

Safety dialogue solutions

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

TFR5 Room or outdoor temperature sensor. CombiTemp TM

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

AS09..S 3-pole Contactors - Spring Terminals

Power Circuit of a UL508A Panel. Typical UL489 Application

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

SQM40/41 Actuators for air and gas dampers

GENERAL CATALOGUE EN013 E C

ENCODERS FOR OIL & GAS

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

ATEX-manual for units

GV2ME. Main. Device short name. Device application

Series CT7N Bimetallic Overload Relays

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Transcription:

s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 16 Amp s and Sockets - IK09/10 Applications s and receptacles are used with portable or stationery electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air conditioning equipment Compressors Pumps For use in corrosive atmospheres and installations in Zone 1 and 2 and 21 and 22 of the oil and gas industry; such as: Refineries Chemical and petrochemical plants Pipelines Loading docks Onshore and offshore drilling platforms Features and socket system is designed with a safe disconnect mechanism to insure maximum hazardous location protection: The contact separation is in a flameproof chamber The automatic electrical disconnection of each phase is contained in a second flameproof chamber Short circuit protection is 20 ka, while normal reference is 10 ka. Different voltages are color coded for easy identification. The receptacles are keyed to accept only ATX plugs (other plugs can not be inserted). ATX plugs can be used in non-hazardous IEC 309 sockets. Operating temperature of -40 ºC to +55 ºC (-40 ºF to +131 ºF) Standard Materials for 2P - - 3P: high impact resistance polycarbonate for - 3P+N+E: high impact resistance fiberglass reinforced polyester, mobile socket and flush socket: polyamide ATEX/IECEx Certifications and Compliances Certification Type PCX, PCX/EN Gas: Zones 1 and 2 Conforming to ATEX 94/9/CE: CE 0081 II 2 G ATEX/IEC Protection: Ex de IIC T6 for Ta +40 C (+104 F) and T5 for Ta +55 C ( Ambient Temperature: -40 C Ta +55 C (-40 F Ta Dust: Zones 21 and 22 Conforming to ATEX 94/9/CE: CE 0081 II 2 D ATEX/IEC Protection: Ex td A21 Surface Temperature: T68 C (T154 F) Ambient Temperature: -40 C Ta +55 C (-40 F Ta CE Declaration of Conformity: 50228, 5C214 ATEX Certificate: LCIE 02 ATEX 6068, LCIE 02 ATEX 0001U IECEx Certificate: IECEx LCI 04.0014, IECEx LCI 04.0012 Other Certifications: GOST Ingress Protection (solid and liquid): Impact Resistance (shock): IK10 (Polyester) and IK09 (Polyamide) Ex Standards: EN/IEC 60079-0; 60079-1; 60079-7; 61241-0; 61241-1 Product Standards: EN/IEC 60309-1, 60309-2 Other Standards: EN/IEC 60529 (IP), 62262 (IK) Technical Data AC 3 ICC Breaking Capacity Wall Mounting Socket 4 kw 220 V 4.3 kw 240 V 7.5 kw 380 V 8.2 kw 415 V 20 ka NBR IEC Brazilian Certifications and Compliances Certification Type PCX, PCX/EN Gas: Zones 1 and 2 Dust: Zones 21 and 22 IEC Protection: ; T6 for Ta +40 C (+104 F) and T5 for Ta +55 C ( Ambient Temperature: -40 C Ta +55 C (-40 F Ta Inmetro Certificate: BR230639, BR230598-U Ingress Protection (solid and liquid): Ex Standards: NBR IEC 60079-0; 60079-1; 60079-7 Other Standards: NBR IEC 60529 (IP) 1362

PRE Series 16 Amp s and Sockets - IK09/10 Wall Mounting Socket Three M20 threaded entries (one on the top and two on the bottom). Supplied with one M20 cable gland 6.5 to 14.5 mm ( 0.26 to 0.57 ) and two M20 blanking plugs. (0.003 x 0.006 in 2 ). Can be through-wired. Fitted with three linked earth terminals. One PG16 integrated cable gland 6.5 to 14.5 mm ( 0.26 to 0.57 ). Terminal capacity 2.5 mm 2 (0.004 in 2 ). One PG16 integrated cable gland 6.5 to 14.5 mm ( 0.26 to 0.57 ). (0.003 x 0.006 in 2 ). (0.003 x 0.006 in 2 ). ing Guide - IECEx Internationally Certified s and Receptacles PRE 2 16 R P IECEx Series: PRE - PRE Series Zone 1, 2, 21 and 22 ATEX / IEC Pin Configuration: 2-2P 3-4 - 5-3P+N+E 6-3P Amps: 16-16A Equipment: P - R - Receptacle (Wall Mounting) M - F - Voltage: P - 20-25 Vac 50/60 Hz W1-20 - 50 Vdc W - 40-50 Vac 50/60 Hz Y - 100-130 Vac 50/60 Hz B - 200-250 Vac 50/60 Hz R - 380-415 Vac 50/60 Hz N - 480-500 Vac 50/60 Hz G - 50-500 Vac 300 to 500 Hz ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles s and Receptacles ing Guide - NBR IEC Brazilian Certified s and Receptacles N PRE 2 16 R P NBR IEC Series: PRE - PRE Series Zone 1, 2, 21 and 22 NBR IEC Certified Pin Configuration: 2-2P 3-4 - 5-3P+N+E 6-3P Amps: 16-16A Equipment: P - R - Receptacle (Wall Mounting) M - F - Voltage: P - 20-25 Vac 50/60 Hz W1-20 - 50 Vdc W - 40-50 Vac 50/60 Hz Y - 100-130 Vac 50/60 Hz B - 200-250 Vac 50/60 Hz R - 380-415 Vac 50/60 Hz N - 480-500 Vac 50/60 Hz G - 50-500 Vac 300 to 500 Hz ELV: Extra Low Voltage Purple White White 20/25 Vac 20/50 Vdc 40/50 Vac LV: Low Voltage Yellow Blue Red Black Green 100/130 Vac 200/250 Vac 380/415 Vac 480/500 Vac 50/500 Vac (300 to 500 Hz) 1363

s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 16 Amp Extra Low Voltage and Low Voltage s and Sockets - IK09/10 Description Pin Configuration Weight kg (lb) Volume dm 3 (in 3 ) IECEx NBR Extra Low Voltage: ELV 20/25 Vac 50/60 Hz Purple 0.6 (1.3) 3.8 (231.89) PRE216RP NPRE216RP 0.2 (0.4) 0.6 (361.6) PRE216PP NPRE216PP polarization 0.4 (0.9) 1.3 (79.33) PRE216MP NPRE216MP 2P tab 0.2 (0.4) 1.3 (79.33) PRE216FP NPRE216FP 10h 0.6 (1.3) 3.8 (231.89) PRE316RP NPRE316RP 10h 0.2 (0.4) 0.6 (36.61) PRE316PP NPRE316PP 0.4 (0.9) 1.3 (79.33) PRE316MP NPRE316MP 0.2 (0.4) 1.3 (79.33) PRE316FP NPRE316FP 0.6 (1.3) 3.8 (231.89) PRE616RP NPRE616RP 0.2 (0.4) 0.6 (36.61) PRE616PP NPRE616PP polarization 0.4 (0.9) 1.3 (79.33) PRE616MP NPRE616MP 3P tab 0.2 (0.4) 1.3 (79.33) PRE616FP NPRE616FP 20/50 Vdc White 0.6 (1.3) 3.8 (231.89) PRE216RW1 NPRE216RW1 0.2 (0.4) 0.6 (36.61) PRE216PW1 NPRE216PW1 auxiliary polarization 0.4 (0.9) 1.3 (79.33) PRE216MW1 NPRE216MW1 tab 10h 2P tab 0.2 (0.4) 1.3 (79.33) PRE216FW1 NPRE216FW1 40/50 Vac 50/60 Hz White 0.6 (1.3) 3.8 (231.89) PRE216RW NPRE216RW 0.2 (0.4) 0.6 (36.61) PRE216PW NPRE216PW polarization 0.4 (0.9) 1.3 (79.33) PRE216MW NPRE216MW 2P tab 0.2 (0.4) 1.3 (79.33) PRE216FW NPRE216FW auxiliary 0.6 (1.3) 3.8 (231.89) PRE616RW NPRE616RW pin 12h 0.2 (0.4) 0.6 (36.61) PRE616PW NPRE616PW polarization 0.4 (0.9) 1.3 (79.33) PRE616MW NPRE616MW 3P tab 0.2 (0.4) 1.3 (79.33) PRE616FW NPRE616FW Low Voltage: LV 100/130 Vac 50/60 Hz Yellow 0.6 (1.3) 3.8 (231.89) PRE316RY NPRE316RY 4h 0.2 (0.4) 0.6 (36.61) PRE316PY NPRE316PY L/+ 0.4 (0.9) 1.3 (79.33) PRE316MY NPRE316MY 0.2 (0.4) 1.3 (79.33) PRE316FY NPRE316FY 200/250 Vac 50/60 Hz Blue L/+ 0.6 (1.3) 3.8 (231.89) PRE316RB NPRE316RB 6h 0.2 (0.4) 0.6 (36.61) PRE316PB NPRE316PB 0.4 (0.9) 1.3 (79.33) PRE316MB NPRE316MB 0.2 (0.4) 1.3 (79.33) PRE316FB NPRE316FB 1364

PRE Series 16 Amp Low Voltage s and Sockets and Accessories - IK09/10 Description Pin Configuration Weight kg (lb) Volume dm 3 (in 3 ) IECEx NBR Low Voltage: LV 200/250 Vac 50/60 Hz Blue 1.5 (3.3) 4.7 (286.81) PRE416RB NPRE416RB L1 L2 0.6 (1.3) 0.6 (361.6) PRE416PB NPRE416PB 9h L3 key way 0.6 (1.3) 4.0 (244.09) PRE416MB NPRE416MB 0.2 (0.4) 1.3 (79.33) PRE416FB NPRE416FB L1 L2 1.6 (3.5) 4.7 (286.81) PRE516RB NPRE516RB 9h 0.3 (0.7) 1.3 (79.33) PRE516PB NPRE516PB N L3 3P+N+E (1) 0.6 (1.3) 4.0 (244.09) PRE516MB NPRE516MB (1) 120/208 V - 144/250 Vac 50/60 Hz 0.2 (0.4) 1.3 (79.33) PRE516FB NPRE516FB 380/415 Vac 50/60 Hz Red L2 1.5 (3.3) 4.7 (286.81) PRE416RR NPRE416RR L1 6h 0.2 (0.4) 0.6 (361.6) PRE416PR NPRE416PR L3 0.6 (1.3) 4.0 (244.09) PRE416MR NPRE416MR 0.3 (0.7) 1.3 (79.33) PRE416FR NPRE416FR L1 L2 1.6 (3.5) 4.7 (286.81) PRE516RR NPRE516RR 6h 0.3 (0.7) 1.3 (79.33) PRE516PR NPRE516PR N L3 0.6 (1.3) 4.0 (244.09) PRE516MR NPRE516MR 3P+N+E (2) (2) 200/346 V - 240/415 Vac 50/60 Hz 0.3 (0.7) 1.3 (79.33) PRE516FR NPRE516FR 480/500 Vac 50/60 Hz Black 1.5 (3.3) 4.7 (286.81) PRE416RN NPRE416RN 7h 0.2 (0.4) 0.6 (361.6) PRE416PN NPRE416PN 0.6 (1.3) 4.0 (244.09) PRE416MN NPRE416MN 0.3 (0.7) 1.3 (79.33) PRE416FN NPRE416FN 50/500 Vac 300/500 Hz Green L3 1.6 (3.5) 4.7 (286.81) PRE516RG NPRE516RG L2 2h 0.2 (0.4) 0.6 (361.6) PRE516PG NPRE516PG L1 N 0.6 (1.3) 4.0 (244.09) PRE516MG NPRE516MG 3P+N+E 0.3 (0.7) 1.3 (79.33) PRE516FG NPRE516FG ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles s and Receptacles Accessories Description IECEx NBR M5 earth stud with black neoprene sealing washer and green/yellow earth conductor, length 300 mm (11.8 ) PREESTM20 NPREESTM20 M20 earth continuity adaptor with black neoprene sealing washer and green/ yellow earth conductor, length 300 mm (11.8 ) PREECAM20 NPREECAM20 1365

s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 16 Amp and Socket Dimensions Dimensions 272.0 mm (10.71 ) 5.5 mm (0.22 ) Wall Mounting Sockets 82.5 mm (3.25 ) 120.0 mm 63.0 mm (4.72 ) (2.48 ) 5.5 mm (0.22 ) 65.0 mm (2.56 ) 202.0 mm (7.95 ) 125.0 mm (4.92 ) 133.0 mm (5.24 ) s Can be mounted on panel - 0.12"/3.0 mm thickness maximum 160.0 mm (6.30 ) 130.0 mm (5.12 ) 3.0 mm (0.12 ) maximum 210 mm (8.27 ) 54 mm (2.13 ) (3.15 ) 46.0 mm (1.81 ) 16A 2P 3P Versions 42.0 mm (1.65 ) 39.0 mm (1.54 ) 46.0 mm (1.81 ) 42.0 mm (1.65 ) 58.0 mm (2.28 ) 39.0 mm (1.54 ) s 152.0 mm (5.98 ) 3.15 / s 54.0 mm (2.13 ) 160.0 mm (6.30 ) 16A 3P+N+E Versions Wall Mounting Sockets s 97.0 mm (3.82 ) Fix. (3.15 ) 240.0 mm (9.45 ) Fix. 105.0 mm (4.13 ) 6.0 mm (0.24 ) 145.0 mm (5.71 ) 140.0 mm (5.51 ) 310.0 mm (12.20 ) B A C Dimensions in Millimeters (Inches) A B C 3 P + E 66.0 (2.60) 154.0 (6.06) 55.5 (2.19) 3 P + N + E 73.0 (2.87) 166.0 (6.54) 62.0 (2.44) s Can be mounted on panel - 3.0 mm (0.12 ) thickness maximum s 160.0 mm (6.30 ) 150.0 mm (5.91 ) 3.0 mm (0.12 ) maximum 230.0 mm (9.06 ) 68.0 mm (2.68 ) 90.0 mm (3.54 ) 60.0 mm (2.36 ) 0.17 90.0 mm (3.54 ) 68.0 mm (2.68 ) 160.0 mm (6.30 ) 1366