Color Codes of Optical Fiber and Color Shade Measurement Standards in Optical Fiber Cables

Similar documents
A Comparison of Dry Versus Gel Filled Optical Cables

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F Ribbon Indoor/Outdoor Riser Cable Preparation

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Panduit Recommended Best Case Practice Split Fibre

Color Codes and Counting Directions for Fiber Optic Cables

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

TENDER SUMMARY. Tender Title:

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

CUSTOM-LENGTH PATCH CABLES CUT-TO-LENGTH BULK FIBER PRE-TERMINATED FIBER MULTI-COLORED FIBER

Underground Installation of Optical Fiber Cable by Pulling

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Detailed Specifications & Technical Data

Visual Color Matching under Various Viewing Conditions

TECHNICAL SPECIFICATION

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

FREEDM Loose Tube Interlocking Armored Cables

Color Manual VOLUME 1 OCTOBER 2017

Revision No. 4 Page No. Page 1 of 7

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Micro duct Cable with HDPE Sheath for Installation by Blowing

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

SPECIFICATION. Optical Fiber Cable

Number of Fiber 6 Core 12 Core. Part Number

OPTICAL CABLE FIBER-LAN INDOOR

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Number of Fiber 6 Core 12 Core 24 Core 48 Core

TECHNICAL GUIDELINE. Universal/Toneable FTTP Cable Applications Guideline. Materials Required

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0553 Identification for Communications Systems

Follow The Leader In Shielded Technology

Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

Introduction. Part 1. Evaluating Color. Color Communication/Terms. Colorist Qualifications. Color Equipment/Instruments. Specifications/Settings

IP-LINX. Installation Guide

Installation of Optical Fiber

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

Colour Features in Adobe Creative Suite

1. General. 1. Scope. 2. Quality Assurance

Optical Distribution Box 300 Installation Guide. Version : R0.0

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Buffer Tube Midspan Access Tool Accessing fibers in buffer tube procedure

How to Speak Fiber Geek Article 4: Single-Mode Optical Fiber Geometries

Supplemental Material: Color Compatibility From Large Datasets

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Mining and Petrochemical Fiber Optic Cables

Mini-breakout & Mini-bundle cable. Riser cabling solution

LD Series High Performance Loose Tube Fiberoptic Cables

2 Types of films recommended for international exchange of television programmes

Gel-sealed in-line fiber optic closure

ISO/IEC TR TECHNICAL REPORT

avenue Submit Forms CONTENTS I. Statement of Purpose Explanation of Effective Color Evaluation Color Standards Lab Dip Process

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

GemeSquare. Gemstone Color Description & Communication System

3M Cold Shrink Splice Kit QS-III 5416A

SECTION 4 TABLE OF CONTENTS

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

CSE Data Visualization. Color. Jeffrey Heer University of Washington

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

3M Distribution Box (DDB)

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

Understanding Human Color Vision

Ø 1000 * 588 mm 50 kg

Connecting cables NEBS, for sensors

User Calibration Software. CM-S20w. Instruction Manual. Make sure to read this before use.

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

3M ScotchCode Wire Marking and Identification System. Identify with 3M

Preferred ordering guide for NETCONNECT

3M Cold Shrink Splice Kit QS-III 5514A

Background Statement for SEMI Draft Document 4759A NEW STANDARD: TEST METHOD OF PERCEPTUAL ANGLE FOR OLED DISPLAYS

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS:

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction

Public Works Division Lighting District Fiber Optic Specifications April 2009

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Micro Cables, Application (Ducts & Accessories, Equipments, Installation)

Primary Colors. Color Palette

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

Background Statement for SEMI Draft Document 5291A New Standard: TEST METHOD OF AMBIENT COLOR GAMUT FOR FPD UNDER INDOOR ENVIRONMENTS

3M Fiber Optic Wall Mount Enclosure 8430 Series

MILITARY SPECIFICATION SHEET

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

DCI Memorandum Regarding Direct View Displays

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

Transcription:

Application Notes Color Codes of Optical Fiber and Color Shade Measurement Standards in Optical Fiber Cables Author Sudipta Bhaumik Issued June 2014 Abstract This application note describes color identification scheme of Optical Fibers in a Sterlite Fiber Optic Cable and most common ways to measure color in fiber optic industry. Munsell color system, L/C/H system, and Delta E system of color identification are described and their equivalence presented. Keywords Color optical fiber, color code, Munsell color chart, Hue, Chroma, Lightness, Delta E

Optical Fiber Colors and Color Codes Like electrical wires, optical fibers are color coded for field recognition during cable installation. In a fiber optic cable buffer tube containing multiple fibers, each fiber needs to be distinguished from others by means of color coding. During splicing/ joining of two fiber ends, like color fibers are spliced to ensure continuity in an optical fiber network.tia/eia-598 is the most widely used color coding standard in fiber optic industry. This standard defines recommended identification scheme for individual fibers, buffered fibers, fiber units within a fiber optic cable both for premises and outdoor applications. Table 1 shows the color codes used for optical fibers in a Sterlite fiber optic cable. Color codes may be customized based on specific customer requirement. Table 1 Sterlite optical fiber color code in cable Fiber Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Base color and Ring marking Blue Orange Green Brown Slate (Grey) White Red Black Yellow Violet Pink Aqua Blue with Black Rinq mark Orange with Black Ring mark Green with Black Ring mark Brown with Black Ring mark Slate with Black Ring mark White with Black Rinq mark Red with Black Ring mark Natural (no color) or Natural with Black Ring mark Yellow with Black Ring mark Violet with Black Ring mark Pink with Black Ring mark Aqua with Black Ring mark Abbreviation BL OR GR BR SL WH RD BK YL VI PK AQ -B-L- -e-r- GR BR - WH RD NT /-1,4- - T L-- --VI- PK AQ Color Control Systems Due to the variability in the manufacturing process, a visual color standard is required to ensure that the base color codes are manufactured within a reasonable tolerance to the exact color. So there is a need for color standard that helps to ensure consistent color between color fiber lots and therefore, safe and easy identification of color fibers during cable installation and testing. There are three main ways to measure and control optical fiber color shades practiced in fiber optic industry.

1. Munsell color system or H/C/V system 2. L/C/H system 3. Color difference or Colortolerance or Delta E (AE) 1. Munsell Color System Munsell color system is a qualitative way to measure and control color shades and is accepted in both TIA/EIA-598 and EIA-359 standards. 1,2 Munsell worked with the Electrical Industries Association (EIA) to develop color standards that correlate to the color coding system for telecom and fiber optics industries 3. Each Munsell color coding standard includes a best match or centroid color plate and acceptable visual variations away from the centroid color. The color of the centroid and other acceptable color plates are specified by Hue (H), Value (V) and Chroma (C). Hue (H) is the quality by which we distinguish one color from other like blue, green, red, etc. Munsell Hue color circle as shown in Fig. 1, is divided into 10 equal regions by five main hues like Red (R), Yellow (Y), Green (G), Blue (B), Purple (P) and five intermediate hues like Yellow-Red (YR), Green-Yellow (GY), Blue-Green (BG), Purple- Blue (PB) and Red-Purple (RP). The colors are placed around a color circle at equal points and the colors in between these points are a mixture of the two, in favor of the nearer point/color as shown in Fig.1. For example, 2.5R, to represent the hue two-and-a-half steps around the circle from Red while moving clockwise. Fig.1 Munsell Hue Circle Chroma (C) (also known as Saturation) is defined as strength or dominance of the hue. It is also stands for intensity or purity of a color. On the outer edge of the hue wheel are the intensely saturated hues. Towards the center of the color wheel, no hue dominates and they become less and less saturated. In Munsell standard, the scale of chroma extends from 0 at the center of the circle, which is completely unsaturated (neutral grey) to 10, 12, 14 or further, depending upon the strength (saturation) of the color. In Fig. 2 chroma of purple-blue color is varied from 0 atthe centerto 12 at the outer edge. Value (V) describes overall intensity or how light or dark a color is. Value in Munsell standard it is expressed as numbers from 0 to 10 in a vertical scale as shown in Fig. 2. Zero stands for no lightness (i.e. completely black) and 10 stands for maximum lightness (i.e. completely white).

Application Notes A Comparison of Dry Versus Gel Filled Optical Cables Fig.2 Munsell color system 2. L/C/H system Munsell color standard plates are widely used qualitative methods to verify color of optical fibers. Color Author shades can also be measured quantitatively by spectrophotometer or colorimeter. Some organizations likejohn BritishPeters Telecom prefer quantitative representation and control of color shades. Most common ways to represent spectrophotometer output are using L/C/H and AE methods. L/C/H is slightly different compare to H/C/V terms used in Munsell color system. Value in the Munsell method is known as Lightness (L) in L/C/H system. The othertwo metrics, Hue and Chroma have the same nomenclature. Issued December 2012 Value (V) in Munsell standard is expressed as numbers from 0 to 10, whereas Lightness (L) is measured in percentage from 0% - 100%, that means L is 10 times of V. Zero stands for no lightness (i.e. completely black) and 100 stands for maximum lightness (i.e. completely white). Fig 3 shows how lightness varies Abstract from zero (black) and 100 (white) in a vertical scale. In L/C/H system, Hues are expressed as an angle The dry cable design compares favorably with a wet design that uses a flooding from 0 to 360 as shown in Fig 3,where Red hue is traditionally at zero degree and that makes Green at compound in the voids within the cable core and/or a thixotropic gel within the buffer -1200, at 240 and so on. In L/C/H Chroma scale is 0 to 100 or more and the numbers are tubeblue to achieve comparable water system blocking performance. approximately 5 times the C in Munsell system. Keywords Dry cable, super absorbent powder, fiber buffer tubes, cable weight, environment friendly, cost savings Fig. 3 Three coordinate color circle according to L/C/H system

3. Color difference or Color tolerance or Delta E (re) Another quantitative way to represent color shades is to calculate difference between two samples where one sample is the reference sample or industry standard and the other is the manufacturing sample. The calculated number is called the re (Delta E) or color difference or color tolerance. re displays the difference as a single number for hue, chroma, and value/lightness. re is calculated by comparing the measurements, taken with a spectrophotometer, of a manufacturing fiber sample (the output) to the data of a known color (the specification or input value). Different studies proposed different formula to calculate re. Two formulas are well practiced in fiber optic industry. a) The formula as shown in equation 1, proposed by International Commission of Illumination (CIE) in 1976 is referred in TIA/EIA-598 standard for controlling cable jacket / sheath color and it is symbolized as reab. reab = V(r Hue) 2 + (r Value) 2 + (r Chroma) 2...Eq (1) b) Color Measurement Committee (CMC) in 1984 proposed a different formula to calculate re and it is symbolized as rcmc 4. Some organizations like France Telecom prefer recmc measurement to control fiber color shades. Target L/C/H values as specified by the buyer, are taken as the input parameter of the spectrophotometer and L/C/H of the manufacturing sample is measured. Both target and measured L/C/H values are used to calculate recmc of a manufacturing sample. Lower the re value, closer is the manufacturing sample to the specifications or reference sample. re values of 4 and over will normally be visible to the average person, while those between 2 and 4 will be visible to an experienced observer. In TIA/EIA-598 standard, reab value less than 6 is acceptable for cable jacket / sheath. recmc value less than 8 are acceptable for most of the optical fiber colors in other industry standards. References 1. TIA/EIA-598-C, Optical fiber cable color coding,january 2005. 2. EIA-359-A, Munsell color chartsfor color coding, 1984. 3. http://munsell.com/color-blog/color-codingchart-wire-color-coding/munsell s New Color Coding Chart-Reference for Specifying Wire and Cable Colors, April 2013. 4. Lindbloom, Bruce Justin. Delta E (CMC). Brucelindbloom.com. Revised 2009-04-16. Copyright 2017 Sterlite Technologies Limited. All rights reserved. The word and design marks set forth herein are trademarks and/or registered trademarks of Sterlite Technologies and/or related affiliates and subsidiaries. All other trademarks listed herein are the property of their respective owners. www.sterlitetech.com