VISY THEATRE TECHNICAL SPECIFICATIONS Version. //0 Auditorium Seating The Visy Theatre is a versatile venue with many configurations. The standard venue hire includes the venue in standard mode with a capacity of 00. The table and diagram below detail the different configurations possible for the venue. Any changes from standard mode will incur a cost of labour to complete the necessary changes. STAGE CONFIGURATIONS Permanent Seating (stalls) Pit Seating Removable Side Seats Total Capacity 00 Configuration Seating sections Capacity Standard mode (-) 00 Permanent seating () Stalls and side bank on stage left and right (+a+b) 0 Configuration Seating sections Capacity Cabaret mode with theatre seats, x 00mm round tables with chairs and x 00mm round tables with chairs (+a+b) Using the numbers listed in the seating sections column, refer to the diagram below to decide on the configuration that is best suited to your event. For further detail contact Brisbane Powerhouse. Stalls with side banks on left and right (+a+b+a+b) Stalls with side banks on left and right (+a+b+a+b+a +b) Stalls with side bank on stage left and side bank on stage right and centre of pit seating (++a+b+a+b) Stalls with side banks on stage left and side banks on stage right and centre of pit seating Stalls with side banks on stage left and side banks on stage right and centre of pit seating Stalls with centre of pit seating Stalls with side banks on stage left and side banks on stage right and centre of pit seating (++a+b+a+b) (++a+b+a+b) 0 ( + ) (++a+b+a+b+ 0 a+b) COMPUTER AIDED DESIGN (CAD) DRAWINGS OF THE VENUE DISPLAYING GRID, STAGE AND LIGHTING LAYOUT ARE AVAILABLE FROM THE VENUE OR BRISBANE POWERHOUSE WEBSITE. IF YOU REQUIRE FURTHER PLANS PLEASE CONTACT THE OF PRODUCTION ON (0) 0 OR YOUR PRODUCTION MANAGER FOR FURTHER DETAILS. Page of
VISY THEATRE TECHNICAL SPECIFICATIONS Version. //0 Staging Brisbane Powerhouse has a limited supply of staging, rigging and height safety equipment available. Height safety equipment required in each venue is provided as part of the venue hire. Additional rigging equipment is available for hire. Please note all rigging must be installed by a licensed rigger. Brisbane Powerhouse can provide a licensed rigger for a fee if required. Additional staging equipment, including soft blacks, rostra and treads, are also available for hire. Please contact Brisbane Powerhouse for the complete list of equipment. RIGGING Fixed grid of mm heavy wall steel scaffold pipe Grid height is.m to the underside of the pipe 0kg per meter distributed load 0kg point load at a concrete insert 0kg point load STAGE FLOOR The stage is a sprung timber dance floor. The top deck is masonite. The floor has a 0kg per square meter distributed load. Lighting The lighting grid is a fixed scaffold grid with a height to the underside of the pipe of.m. For point loads and rigging information refer to rigging section across. The space comes with a square one lighting rig patched and focused as part of the hire. This can be de-rigged prior to bump in if needed. Additional lighting equipment is available for hire. Please contact Brisbane Powerhouse for the complete list of equipment available for hire. LIGHTING FIXTURES x ETC w Source Four junior /0 zoom profiles 0 x Selecon.k Fresnel x Selecon Rama.k Fresnel x ETC 0w Source Four pars (MFL, WFL, NSP, VN SP lenses available) x Par MFL x LEDForce RGBW x Selecon 00w cell cyc battens ACCESSORIES 0 x Iris four ET C Source Four juniors 0 x M size gobo holders DIMENSIONS Stage size when sunken pit seating is open Stage edge to upstage columns.m Stage edge to rear wall.0m Stage left tostage right.m Stage size when sunken pit seating is closed Stage edge to upstage columns.m Stage edge to rear wall.0m Stage left to Stage right 0m LIGHTING CONTROL x HPC & x HP digital dimmer racks located in a central dimmer and patch room x ETC Ion 000 with fader wing and radio focus remote x stream of DMX is distributed to the grid and dimmer room via LSC ISO system House lights are controlled via a Dynalite System. DMX control of houselights is available if required. Stage size when sunken pit seating is closed and side banks removed Stage edge to upstage columns.mm Stage edge to rear wall. Stage left to stage right m DRAPES The venue comes supplied with x gathered blacks.m wide x.m high x tabs,.0m x.m each. Page of
VISY THEATRE TECHNICAL SPECIFICATIONS Version. //0 Power Brisbane Powerhouse works on a distributed dual earth power system. The audio system operates on a true online UPS to condition the power and is on a separate earth to main power distribution. All audio points are red in colour. 0 amp phase outlets are distributed around the venue and in the dimmer room. As part of the venue hire a limited supply of 0v leads are supplied. Additional phase leads and weiland cables are available for hire. x 0 amp phase outlets in dimmer room x 0 amp phase outlets in rear stage, one stage left and one stage right x 0 amp audio phase located in bio box All audio power is run on a separate earth and is filtered by a UPS Sound The Visy Theatre comes supplied with a full front of house audio system and a small amount of fold back. The system includes console and play back. The system runs Meyer self-powered FOH boxes with the room EQ being provided by XTA EQ0 s. A limited supply leads and adaptors are available as part of venue hire. FOH CONTROL DiGiCo SD console x dual channel XTA band EQ for front of house x Tascam CD0u CD player CABINETS x Meyer UPJ p speakers in the roof provide front x Meyer UPA-p speakers x Meyer USW p sub-woofer Stage Management System The Stage Management System within the theatre comprises of a Stage Manager s Desk (SMD) which can be located in the control room or either back stage left or right. The system has full paging and relay to the dressing rooms ( - ) attached to the Visy Theatre. As part of venue hire talk back is provided at the SMD, sound desk and lighting desk as well as one additional set for back stage. Additional talk back is available for hire if required. Stage Manager s Desk Inbuilt cue light system Paging to dressing rooms attached to the theatre Stage camera (full colour) located on centre of grid bar Stage monitor located in Prompt Corner Stage relay to SMD and dressing rooms Clear-com talk back base station with Beyer headsets additional belt packs and Beyer headsets FOLD BACK x martin audio LE JB high powered fold back wedges x QCS dual channel amplifiers MICROPHONES/DI x Shure SM microphones x Shure SM microphones Pianos Brisbane Powerhouse has the following pianos available for hire: x Yamaha key Upright piano x Boston key Baby Grand piano Page of
VISY THEATRE TECHNICAL SPECIFICATIONS Version. //0 Miscellaneous Assistive Listening System The venue is equipped with an UHF assistive hearing system for patrons. Head sets are collected by patrons as needed from box office. Smoking Policy The Brisbane Powerhouse is a non-smoking venue. Persons who smoke are required by law to smoke only in Designated Smoking Areas. Fire Evacuation and Work Place Health and Safety Induction All visiting clients, including crew and cast, must undergo a venue specific induction regarding fire evacuation and workplace health and safety. A copy of the Brisbane Powerhouse fire evacuation procedure is available on request. It is a requirement of Brisbane Powerhouse Work Place Health and Safety that closed-in shoes are worn on stage for all site inspections, bump in and bump outs. Risk Assessment Shows which are deemed to contain an item or event that may cause a potential hazard may be required to complete a risk assessment in consultation with Brisbane Powerhouse. Insurance Details of insurance provided with venue contract. Page of
ELEVATION Scale : 0m m m m m 0m FLOOR PLAN Scale :0 Lighting Grid.m.m.m.m.m 0.m 0.m 0.m.0m US Curtain.m BACKSTAGE.m.m.m SECTION Scale : 0m m m m m 0m m m m m 0m.m.m.m.m.0m.m Standard Masking AUDIENCE ENTRY.0m Lighting Bars Lighting Grid.0m.m.m Seating.m.0m Backstage Stage Pit Seating Bank.0m 0.m.0m 0.m.m.m.m.m.m ISOMETRIC Not to Scale.m PIT SEATING CONTROL ROOM Venue: Visy Theatre Plan: Venue Plans - Floor Scale: Scale correct @ A Printed: 0// File: VISY THEATRE v Version:.0
.0m US Curtain.m BACKSTAGE.m.m.m.m.m.m.m.0m.m Standard Masking AUDIENCE ENTRY.0m.0m.m.0m.m.m.m PIT SEATING CONTROL ROOM Venue: Visy Theatre Plan: Floor Plan Detailed Scale: : @ A Printed: 0// File: VISY THEATRE v Version:.0
.0m CONTROL ROOM.0m a b a a b b a b REMOVEABLE BANKS PIT SEATING REMOVEABLE BANKS CONTROL ROOM Seating Configurations Type Bank Quantity Permanent Seating Pit Seating, Centre Pit Seating, Sides a & b 0 per side Removeable Seating a - a per section Total Seats -. 00 Venue: Visy Theatre Plan: Seating Scale: : @ A Printed: 0// File: VISY THEATRE v Version:.0
TOP VIEW LX LX LX B LX A LX 0 0 LX 0 0 L0 L L 0 0 0 0 L0 L L 0 0 L0 L L 0 0 LX 0 0 0 L0 L0 LX 0 L0 L0 0 0 0 LX L L0 L L L0 L L L0 L 0 0 0 L0 L0 LX L0 L0 LX L L0 L L L0 L L L0 L 0 0 0 0 L0 L0 LX L0 L0 0 0 L L0 L L L0 L L L0 L LX L0 L0 L0 L0 L0 L0 LX A LX B 0 0 0 LX C LX D LX E LX F LX G LX H LX I LX 0 LX J LX K LX L FOH FOH LEGEND Source Jr /0 Selecon.k Fresnel Selecon Rama.k Fresnel For grid and rigging point load information please refer to venue technical specifications. KEY Colour Gobo Unit Number Channel Outlet Number DMX Address Source Par WFL Par MFL LEDForce ( channel mode) Unique Hazer NOTES: - All Fresnels have barndoors. - Lighting console is ETC Ion with x 0 fader wing and RFR. - ETC Pars available with VNSP, NSP, MFL or WFL lens. - Speakers are Martin EM's hung from grid. - Rear stage bars (LX - LX ) do not have patch outlets. - Lamps must not be rigged in areas indicated with red circles. Sprinkler heads are located at these points. Martin EM LIGHTING BAR HEIGHTS Sprinkler Head LX - @.m LX - @.m LX A & K @.0m LX B & J @.m LX C - I @.m LX L @.m Venue: Visy Theatre Plan: Lighting Standard Rig Scale: : @ A Printed: 0// File: VISY THEATRE v Version:.0