Nova T C.L dimmer with wallplate, 250W CFL/LED, 1000W. Incandescent, Halogen, CFL,LED, Lutron Hi-Lume A-Series LTE LED Driver Plastic-Gloss Finish

Similar documents
Special Order To order, add color/finish suffix code to model number. Example: NT-600-BB Metal Finishes. Special Metal Finishes

Nova T* Controls. number. Example: NT-600-BB. Special Order. Metal Finishes. Special Metal Finishes. Anodized Aluminum Finishes

Nova T* Controls. Nova T*

Special Order To order, add color/finish suffix code to model number. Example: NT-600-BB Metal Finishes. Special Metal Finishes

Nova T* Controls. Wallbox Controls. Dimmers, Switches, and Accessories

Nova T Controls. Wallbox Controls. Dimmers, Switches, and Accessories

NTF10277WH NTF10277WH Dimmer Control

Ariadni Dimmer For 250W CFL/Led, 600W Inc/Hal, or Lutron Hi-Lume A-Series Lte Led Driver, Clamshell Packaging In White

AYCL253PBR Ariadni 250W Led 3WAY Dimmer Brown

Wallplates and accessories Designer Claro and Satin Colors

Caseta Wireless 3-Way/Single-Pole RF Dimmer For Led, Elv, MLV, or Halogen Lights In White

MRF2600MLA 600W 120V RF Wireless Dimmer LT Almond

Maestro Wireless Dimmers and Switches

Spacer System dimmers and switches

Lutron. Rania digital dimmer. Rania For 230 V loads, multiway Max. 500 W, min. 50 W For 230 V and 12 V loads, multiway Max. 450 W/VA, min.

Lutron. Rania digital dimmer with remote control

Maestro 0 10 V Dimmer Sensor

RadioRA 2 Enhancement and Interface, 120V main repeater with MHz to MHz or MHz to MHz

3000 Series. The World s Finest Multi-Scene Preset Lighting Control. Product Family Features. Specification Features. System Features.

Maestro Dual Technology Sensor Switch

3000 Series. The World s Finest Multi-Scene Preset Lighting Control. Product Family Features. Specification Features.

D600EI Iv 600W Inc Slide Dimmer

DIN Power Module - Phase Adaptive

PowPak Dimming Module with 0 10 V- Control

PowPak Dimming Module with 0 10 V Control

Acenti. For technical support call Online catalog available at leviton.com 13

VZT2S54 Electr DMMG Ballast

Lighting Zone Controller. Specifications

Modular pulse operated latching relay 16 A

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

PrimaLine 1.5 XT Wet Location LED Tape Light

WLB SERIES HID Lighting for Hose Down Applications

SECTION 4 TABLE OF CONTENTS

CR Series LED Downlights Easy to Install with Unprecedented Payback

blackbox.com/connect The smart choice when price matters most. Need help? Talk to a Black Box cable expert 24/7 at

ALLEN BRADLEY TIMING RELAY

92656 XR RTQ RG-6 F Comp Connector 100JR

ABB i-bus EIB Universal dimmer 6155 EB for Installation

Follow The Leader In Shielded Technology

Switching Power Module

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Controlling LEDs. why various control types are needed the existing methodologies used to control LEDs. Technical white paper January 2011

PROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

15 Series - Dimmer

Series CDP2 Definite Purpose Contactors

Identification - electrical services

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Dimensions and Weight Size 2.79 HEIGHT X 1.6 WIDTH X 1.19 DEPTH IN, HEIGHT X WIDTH X DEPTH MM

LCS2 Cat. 6 RJ 45 Patch panels and units

SECTION COMMUNICATIONS HORIZONTAL CABLING

The Uniduct Nonmetallic Latching Raceway

Compact Module. Category 6 FTP Cabling System

LCS 2 RJ 45 Cat. 6A HD panels and units

120 V~ Feed-Through DIN Panels (and Accessories)

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

XML LED X M L L E D. Explosionproof Linear LED Lighting

Wire Connector, Wire Size 18 to 12 Gauge; Yellow; Standard Package 100 Per Box; Approval Ul; Scotchlok[T] Brand

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

Gamma instabus. Technical product information

INSTALLATION AND OPERATION MANUAL

with EcoSystem Control Unit Installation and Operation Guide Please Read

Illustrated Feature. Options

CONNECT TO VALUE THE SMART CHOICE WHEN PRICE MATTERS MOST BLACK-BOX.EU/CONNECT

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

BLACK-BOX.EU/CONNECT

Church Layout Medium Advanced

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

Operating Instructions Dimmer for V Incandescent Lamps

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

with EcoSystem Please Read

SQM40/41 Actuators for air and gas dampers

EXLUX ECOLUX 6480 Series

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

CR Series LED Downlights. Easy to Install with Unprecedented Payback THE QUALITY YOU DEMAND WITH THE SAVINGS YOU DESERVE.

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

Multi-Media Installation Guide

FLUID VIEW 12V LED TAPE LIGHT

TOKISTAR TOKISTAR LIGHTING

SECTION Structured Cabling Systems

EXLUX ECOLUX C-LUX 6480 Series

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

STRUCTURED CABLING SYSTEMS (SCS)

Data Sheet Definite Purpose Contactors Ex9CK Series

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

LED Lighting 12 th Annual Building Codes Education Conference March Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design Lab

OT 100/ /700 P5

CONTRACTORS SPECIFICATION

PREMIUM 5e F/UTP PRODUCTS

Profile 10F User Manual

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Best Friends General Trading FZE

6LE-AURA-REM-CT 6" APERTURE REMODEL DIRECT LED RECESSED DOWNLIGHT COLOR TUNING

Transcription:

NTCL250WH 1000W Lutron Catalog Number Manufacturer Description Weight per unit Product Category Features actuator load Material Poles 3 Voltage Rating 120 Wattage 250/600 Dimensions and Weight Size Descriptions Description Long Description Product Type special features NTCL250WH Lutron Nova T C.L With Wallplate, 250W CFL/Led, 1000W Inc/Hal, or 3.3A Lutron Hi-Lume A-Series Lte Led Driver (Max 10 Drivers), 120V In 0.4000 (lbs/each) Lighting s Toggle Incandescent, Halogen, CFL,LED, Lutron Hi-Lume A-Series LTE LED Driver Plastic-Gloss Finish 4.6in (117mm) x 2.86in (73mm) 1000W DIMMER Nova T C.L dimmer with wallplate, 250W CFL/LED, 1000W inc/hal, or 3.3A Lutron Hi-Lume A-Series LTE LED Driver (max 10 drivers), 120V in white Novat 250W CFL/Led 1000W Inc WH Uses Lutron patent pending HED Microprocessor technology. SSL-7A compliant.

Manufacturer Information Brand Lutron GTIN 00784276107488 Manufacturers Part Number NTCL250WH sub brand NovaT UPC 784276107488 Taxonomies, Classifications, and Categories Category Description DIMMERS Type C.L Packaging Carton 1 Package 12 Weight Per each 0.4 Uses, Certifications, and Standards environmental conditions Indoor use only Frequency Rating 60 Mounting WALLBOX Operating Temperature 0-40 C standard UL, CSA, NOM

s, Switches, and Accessories Nova T* s This series of classic thin-profile linear-slide dimmers and switches offers the following standard features: Square Law Dimming Voltage compensation (not applicable to NTCL-250) Power-failure memory Superior RFI suppression Captive linear slider Accessible air-gap switch Electrostatic discharge tested Precise color matching Heavy-duty components for surge protection and long product life 100% factory tested Product Family Features Available for 120 277~ line voltage switching (sink only control) 0 10 V- LED drivers and ballasts (power pack not required for loads up to 8 A) Excellent for residential or commercial applications Intuitive operation; easy to use Slide-to-off and preset models available Enclosed heat sink for aesthetically pleasing appearance Multi-gang alignment for quick and easy installation Full family of products for most lighting sources, plus matching accessories and wallplates Rated at 120 V~ 60 Hz, unless noted otherwise Custom products (CPN) are available to meet specific customer needs. Please contact Lutron Customer Service at 888.588.7661 for availability. Regulatory Approvals UL CSA NOM Colors and Finishes When ordering product for use with metal wallplates, the product and wallplate must be ordered separately. See the Architectural Wallplates and Accessories section of Volume 1: Basic Devices and Single-Space Systems Catalog (P/N 367-1746) for ordering procedure. See table to the right for complete list of metal finishes. Custom color matching is available for all Nova T* products. A swatch or sample is all that is required. Call customer service to arrange for a color-matched control. Slide-to-Off s Select light level with slider; slide down to OFF 369616j 1 02.22.16 Preset s Select light level with slider; press ON/OFF Engraving is available for all Nova T* products. Engraving schedules are available at www.lutron.com/engraving or through Customer Service at 888.588.7661. Available Colors and Finishes Matte Finishes To order, add color/finish suffix code to model number. Example: NT-600-WH Code Color Code Color Code Color WH GR Gray BE Beige TP Taupe IV Ivory SI Sienna AL Almond LA Light Almond BR Brown BL Special Order To order, add color/finish suffix code to model number. Example: NT-600-BB Metal Finishes Code Color Code Color SB Satin Brass BB Bright Brass BC Bright Chrome Special Metal Finishes Code Color Code Color QB Antique Brass QZ Antique Bronze SC Satin Chrome SN Satin Nickel BN Bright Nickel Anodized Aluminum Finishes Code Color Code Color Code Color CLA Clear BLA BRA Brass

s, Switches, and Accessories Dimensions Measurements shown as: in (mm) Small Large Profile 369616j 2 02.22.16 Back Views: NT- models NT-600 NT-1000 4.56 (116) 2.75 (70) NT-1500 0.30 (8) 2.75 (70) 4.56 (116) 1.31 (33) Note: Some models as deep as 1.9 (48) NT-2000 Available s and Accessories (Summary) For specific uses, capacities, and model numbers, see the following pages. s Slide-to-Off s Preset s ar-slide Switches Slide-to-Off Fan-Speed s Small Large Small Large Small Small Large Receptacles and Plugs Receptacles GFCI Receptacles Isolated Ground Receptacles Duplex for Dimming Use Half for Dimming Use Replacement Plug for Dimming Use 15 A 20 A 15 A 20 A 15 A 20 A 15 A 20 A 15 A 20 A 10 A Jacks and Ports Single Telephone Double Telephone Triple Telephone Cable TV Telephone/ Cable TV 6-Port Frame

s, Switches, and Accessories Specifications 369616j 3 02.22.16 Incandescent s: Slide-to-Off Small Large Single pole 120 V~ 60 Hz 600 W NT-600-XX Single pole 120 V~ 60 Hz 1000 W NT-1000-XX Single pole 120 V~ 60 Hz 1500 W NT-1500-XX Single pole 120 V~ 60 Hz 1950 W NT-2000-XX The NT-2000-XX does not have removable side sections; it can be ganged but must be kept intact. The NT-2000-XX requires a 2-gang wallbox. Incandescent s: Preset Small Large Single pole/3-way/4-way 120 V~ 60 Hz 600 W NT-603P-XX Single pole/3-way/4-way 120 V~ 60 Hz 1000 W NT-1003P-XX Single pole/3-way/4-way 120 V~ 60 Hz 1500 W NT-1503P-XX For 3-way or 4-way switching, use NT-3PS-XX (3-way), NT-4PS-XX (4-way), or other mechanical switches. C L s: Slide-to-Off Small Dimmable CFL/LED 250 W NTCL-250-XX Single pole 120 V~ 60 Hz Incandescent/Halogen 1000 W Single pole 120 V~ 60 Hz Hi-lume A-Series LTE LED driver Single pole 120 V~ 60 Hz 400 W (maximum of 10 drivers) Mixed bulb type Single pole 120 V~ 60 Hz See Derating: Maximum Capacities in Multigang Installations Application requirements: When dimming CFLs or LEDs, only bulbs marked or rated as dimmable and on the recommended list may be used. For a complete list of recommended dimmable CFLs and LEDs please visit www.lutron.com/dimcflled. For questions call 1.800.523.9466. Some dimmable CFLs and LEDs require a minimum number of bulbs for proper operation. For details and the bulb list, visit www.lutron.com/dimcflled For LED product selection tool, visit www.lutron.com/ledtool Features: Low-end adjustment to accommodate a wide range of bulbs. HEDT Technology: Advanced Lutron dimming circuitry designed for compatibility with most high efficacy light bulbs. NEMA SSL-7A Type 2 compliant. Electronic Low-Voltage (ELV) s: Slide-to-Off Small Single pole 120 V~ 60 Hz 300 W NTELV-300-XX Single pole 120 V~ 60 Hz 600 W NTELV-600-XX Maximum capacity is permitted lamp wattage. Requires neutral wire connection. For larger capacity ELV loads (up to 1000 W), use Nova T* fluorescent dimmers (NTF-10-XX or NTF-103P-XX) with a PHPM-WBX interface. (continued on next page )

Specifications (continued) s, Switches, and Accessories 369616j 4 02.22.16 Magnetic Low-Voltage (MLV) s: Slide-to-Off Small Single pole 120 V~ 60 Hz 600 VA / 450 W NTLV-600-XX Single pole 277 V~ 60 Hz 600 VA / 450 W NTLV-600-277-XX Single pole 120 V~ 60 Hz 1000 VA / 800 W NTLV-1000-XX Single pole 277 V~ 60 Hz 1000 VA / 800 W NTLV-1000-277-XX Large Single pole 120 V~ 60 Hz 1500 VA / 1200 W NTLV-1500-XX Maximum capacity is permitted lamp wattage. 277 V~ models require neutral wire connection. Magnetic Low-Voltage (MLV) s: Preset Small Single pole/3-way/4-way 120 V~ 60 Hz 600 VA / 450 W NTLV-603P-XX Single pole/3-way/4-way 120 V~ 60 Hz 1000 VA / 800 W NTLV-1003P-XX Large Single pole/3-way/4-way 120 V~ 60 Hz 1500 VA / 1200 W NTLV-1503P-XX For 3-way or 4-way switching, use NT-3PS-XX (3-way), NT-4PS-XX (4-way), or other mechanical switches. Fluorescent s for Lutron 3-wire fluorescent ballasts or LED drivers: Slide-to-Off Small Single pole 120 V~ 60 Hz 16 A NTF-10-XX Single pole 277 V~ 60 Hz 8 A NTF-10-277-XX Use with Lutron 3-wire fluorescent ballasts or LED drivers only. For LED loads, please see the Report Cards at www.lutron.com/hilumeled for proper loading of the dimmer. No derating required. To determine the number of ballasts that can be controlled by Nova T* fluorescent dimmer, divide the control capacity by the ballast current. For a complete list of Lutron ballasts and ballast currents, see the Fluorescent Dimming System Selection Guide (P/N 366002) at www.lutron.com. Fluorescent s for Lutron 3-wire fluorescent ballasts or LED Drivers: Preset Small Single pole/3-way 120 V~ 60 Hz 8 A NTF-103P-XX Single pole/3-way 277 V~ 60 Hz 6 A NTF-103P-277-XX Use with Lutron 3-wire fluorescent ballasts or LED drivers only. For LED loads, please see the Report Cards at www.lutron.com/hilumeled for proper loading of the dimmer. For 3-way or 4-way switching, use NT-3PS-XX (3-way), NT-4PS-XX (4-way), or other mechanical switches. No derating required. To determine the number of ballasts that can be controlled by Nova T* fluorescent dimmer, divide the control capacity by the ballast current. For a complete list of Lutron ballasts and ballast currents, see the Fluorescent Dimming System Selection Guide (P/N 366002) at www.lutron.com. (continued on next page )

Specifications (continued) s, Switches, and Accessories 369616j 5 02.22.16 0 10 V- s for Electronic Ballasts or LED Drivers: Slide-to-Off Description Maximum Capacity * Model Number Small Load 0 10 V- Sink Single pole 0 10 V- 120 277 V~ NTSTV-DV-XX 8 A 30 ma Power pack not required for loads up to 8 A. May use Lutron power pack (model PP-DV or PP347H; see Lutron P/N 369544) for higher load current applications or for Class 2 installations. Compatible with any IEC 60929 annex E compliant LED drivers and ballasts. Refer to LED driver and ballast manufacturer's specification for 0 10 V- sink currents. has a high and low end trim to adjust the 0 10 V- output for optimal dimming performance. * Limited by whichever rating is achieved first. Fluorescent s for Tu-Wire Electronic Ballasts: Slide-to-Off Small Single pole 120 V~ 60 Hz 5 A NTFTU-5A-XX Single pole 277 V~ 60 Hz 5 A NTFTU-5A-277-XX Use with Lutron Tu-Wire line voltage control electronic dimming ballasts only. To determine the number of ballasts that can be controlled by Nova T* fluorescent dimmer, divide the control capacity by the ballast current. For a complete list of Lutron ballasts and ballast currents, see the Fluorescent Dimming System Selection Guide (P/N 366002) at www.lutron.com. Compatible with Advance Mark X and Sylvania Powersense ballasts. Fluorescent s for Advance Mark X VEZ series 277 V~ Ballasts: Preset Small 3-way 277 V~ 60 Hz 3 A NTFTU-103P-277-XX-CPW0196 For control of permanently installed Advance Mark X VEZ series 277 V~ ballasts only. Install on load side only. No derating required. To determine the number of ballasts that can be controlled by Nova T* fluorescent dimmer, divide the control capacity by the ballast current. For a complete list of Lutron ballasts and ballast currents, see the Fluorescent Dimming System Selection Guide (P/N 366002) at www.lutron.com. ar-slide Switches for General Purpose: All Sources and Motor Loads Small No derating required. Single pole 120 / 277 V~ 60 Hz 20 A NT-1PS-XX 3-way 120 / 277 V~ 60 Hz 20 A NT-3PS-XX 4-way 120 / 277 V~ 60 Hz 20 A NT-4PS-XX Advance and Mark X are registered trademarks of Phillips Corporation. Powersense is a registered trademark of Sylvania Corporation. (continued on next page )

Specifications (continued) s, Switches, and Accessories 369616j 6 02.22.16 Fan-Speed s: Quiet Small For use with one ceiling paddle fan. No derating required. Fan-Speed s: Fully Variable Small Single pole, 3-speed 120 V~ 60 Hz 1.5 A NTFSQ-XX Single pole, Adjustable minimum speed 120 V~ 60 Hz 6 A NTFS-6E-XX Large Single pole, Adjustable minimum speed 120 V~ 60 Hz 12 A NTFS-12E-XX For use with one or more ceiling, ventilation, or exhaust fans. Do not mix fan types on same control.

s, Switches, and Accessories Accessory Specifications 369616j 7 02.22.16 Receptacles and Plugs No derating required. Receptacle Tamper Resistant Receptacle 15 A 125 V~ NTR-15-XX 20 A 125 V~ NTR-20-XX 15 A 125 V~ NTR-15-TR-XX 20 A 125 V~ NTR-20-TR-XX Tamper Resistant, Self-Testing GFCI Receptacle 15 A 125 V~ NTR-15-GFST-XX 20 A 125 V~ NTR-20-GFST-XX Insert is permanently attached to the back cover. No derating required. 15 A 125 V~ NTR-15-IG-OR-XX Isolated Ground Receptacle 20 A 125 V~ NTR-20-IG-OR-XX Insert is orange; wallplate is color selected. Receptacles can be special-ordered to match wallplate color; contact Lutron Customer Service at 888.588.7661 or visit www.lutron.com. No derating required. Tamper Resistant Duplex for Dimming Use 15 A 125 V~ NTR-15-DDTR-XX 20 A 125 V~ NTR-20-DDTR-XX Insert is permanently attached to the back cover. No derating required. Tamper Resistant Half for Dimming Use 15 A 125 V~ NTR-15-HDTR-XX 20 A 125 V~ NTR-20-HDTR-XX Insert is permanently attached. No derating required. Replacement Plug for Dimming Use 10 A 125 V~ RP-FDU-10-XX (continued on next page )

Accessory Specifications (continued) s, Switches, and Accessories 369616j 8 02.22.16 Jacks Accessory Type Description Model Number Single Telephone Jack 6-conductor RJ11. Also accepts most 4-conductor plugs NT-PJ-XX Cable TV Jack F-style 75 Ohm coaxial cable NT-CJ-XX No derating required for any cable jack configurations. A physical barrier (partition) must exist when ganging with any line-voltage products. Frames Accessory Type Description Model Number Field Customizable 6-port frame Ships with 6 blank ports. Use with connectors shown below. Each connector fills 1 port. NT-6PF-XX Connectors Accessory Type Description Model Number 6-conductor RJ11 Category 3 CON-1P-C3-WH Telephone Jack Connector 8-conductor RJ45 Category 5e CON-1P-C5E-WH 8-conductor RJ45 Category 6 CON-1P-C6-WH Fiber Jack Connector MT-RJ feed-through CON-1F-MTRJ-WH Fiber Jack Connector SC simplex CON-1F-SC-WH Fiber Jack Connector LC non-flush mount CON-1F-LC-WH Fiber Jack Connector ST style CON-1F-ST-WH Cable Jack Connector F-style 75 Ohm coaxial cable CON-1C-WH BNC Jack Connector BNC connector CON-1B-WH

s, Switches, and Accessories Wallplate Specifications 369616j 9 02.22.16 Wallplates Description Dimensions (w h) Model Number Single gang: For 1 small control (provided with control) 2.75 in 4.56 in (70 mm 116 mm) VWP-1-XX Single gang: For 1 accessory 2.75 in 4.56 in (70 mm 116 mm) VWP-R-XX 2 Gang: For 2 small controls 4.56 in 4.56 in (116 mm 116 mm) VWP-2-XX 2 Gang: For 2 accessories 4.56 in 4.56 in (116 mm 116 mm) VWP-2R-XX 2 Gang: For 1 small control (left) and 1 accessory (right) 4.56 in 4.56 in (116 mm 116 mm) VWP-2CR-XX 2 Gang: For 1 accessory (left) and 1 small control (right) 4.56 in 4.56 in (116 mm 116 mm) VWP-2RC-XX 3 Gang: For 3 small controls 6.32 in 4.56 in (161 mm 116 mm) VWP-3-XX 4 Gang: For 4 small controls 8.45 in 4.56 in (215 mm 116 mm) VWP-4-XX For other configurations, including small controls, large controls, and accessories, refer to the Specification Guide on the s and Switches product page at www.lutron.com, or call Lutron Customer Service at 888.588.7661 for assistance. For other faceplates, see the Lutron Custom Architectural Multi-gang tool at: www.lutron.com/en-us/service-support/pages/ technical/design-selectiontools/multigang.aspx

s, Switches, and Accessories Derating: Maximum Capacities in Multigang Installations* When installing more than one dimmer in the same wallbox, it may be necessary to remove some side sections prior to wiring (see diagram below). Removal of side sections may reduce maximum wattage, as shown in the charts below. Mixing bulb types (using a combination of CFL/LED and incandescent/halogen bulbs) will also affect the maximum ratings, as shown in the chart below. Example: If one set of side sections is removed and you have eight 9 W LED bulbs installed (Total LED Wattage = 72 W), you may add up to 500 W of incandescent or halogen lighting. 369616j 10 02.22.16 Do not remove outside sections (shaded areas below) Each control has inside sections removed Middle control has two side sections removed Single Units Full capacity. No side sections removed End Units One side section removed Middle Units Two side sections removed Incandescent s 600 W 500 W 300 W 1000 W 900 W 700 W 1500 W 1250 W 1000 W 1950 W NT-2000-XX controls (for 1950 W capacity) must be ganged without removing side sections. C L s Maximum Allowable Incandescent/Halogen Wattage + Total CFL/LED Wattage Installed (Wattage per bulb number of bulbs) 1000 W 800 W 600 W + 0 W 800 W 600 W 500 W + 1 W 40 W 600 W 500 W 400 W + 41 W 80 W 500 W 400 W 300 W + 81 W 120 W 400 W 300 W 200 W + 121 W 160 W 300 W 200 W 100 W + 161 W 200 W 0 W 0 W 0 W + 201 W 250 W No derating is required for multigang installations if only LED bulbs are used or if no fins are broken. * For more information on multigang installations, visit www.lutron.com/en-us/service-support/pages/technical/installationinstructions/ganging-derating/ GangingDerating.aspx (continued on next page )

s, Switches, and Accessories Derating: Maximum Capacities in Multigang Installations* (continued) 369616j 11 02.22.16 Single Units Full capacity. No side sections removed End Units One side section removed Middle Units Two side sections removed Electronic Low-Voltage (ELV) s 300 W 300 W 250 W 600 W 500 W 400 W Permitted lamp wattage for ELV controls. Magnetic Low-Voltage (MLV) s 600 VA/450 W 500 VA/400 W 300 VA / 250 W 1000 VA/800 W 900 VA/750 W 700 VA / 500 W 1500 VA/1200 W 1250 VA/1000 W 1000 VA / 800 W Permitted lamp wattage for MLV controls. Fluorescent 3-Wire Ballast or LED Driver s 6 A No derating required 8 A No derating required 16 A No derating required Fluorescent Tu-Wire s 3 A No derating required 5 A 4 A 3.3 A 0 10 V- Electronic Ballast or LED Driver s Load 0 10 V- Sink 8 A 30 ma No derating required Quiet Fan-Speed s 1.5 A No derating required Fully Variable Fan-Speed s 6 A 4.2 A 2.5 A 12 A 10 A 8.3 A * For more information on multigang installations, visit www.lutron.com/en-us/service-support/pages/technical/installationinstructions/ganging-derating/ GangingDerating.aspx

Wiring Diagrams: Single Location s, Switches, and Accessories 369616j 12 02.22.16 Single-Pole 1 NT-600-XX NT-1000-XX NT-1500-XX NT-2000-XX 2 NTCL-250-XX NTLV-600-XX NTLV-1000-XX 1 NTLV-1500-XX NT-1PS-XX NTFSQ-XX Load Key Ground Wire connector 1 Wire or brass/ gold screw terminal* 2 Wire or green screw terminal* 3 Wire or copper/ black screw terminal* * s have wires; switches have screw terminals Fan 3 (capped) 1 Yellow** (capped) 2 Load Load (fan) NT-603P-XX NT-1003P-XX NT-1503P-XX NTLV-603P-XX NTLV-1003P-XX NTLV-1503P-XX NT-3PS-XX NTFS-6E-XX NTFS-12E-XX ** Switched full-voltage only Single-Pole with Fan/Light or Yellow Yellow Load Load (fan) Load (incandescent)** NTELV-300-XX** NTELV-600-XX** NTLV-600-277-XX NTLV-1000-277-XX ** Use NTELV- models with 120 V~ only NTFS-6E-XX NTFS-12E-XX ** Switched full-voltage only

Wiring Diagrams: Multi-Location Side s, Switches, and Accessories 369616j 13 02.22.16 Key Ground Switch 3 Wire connector 1 Wire or brass/ gold screw terminal* 2 Load 2 Wire or green screw terminal* 3 Wire or copper/ black screw terminal* Load Side 3 Switch * s have wires; switches have screw terminals 2 Load NT-603P-XX NT-1003P-XX NT-1503P-XX NTLV-603P-XX NTLV-1003P-XX NTLV-1503P-XX NT-3PS-XX 4-Way Side 3 4-Way Switch 3 Switch 3 2 2 Load Load Side 3 Switch 3 4-Way Switch 3 2 2 Load NT-603P-XX NT-1003P-XX NT-1503P-XX NTLV-603P-XX NTLV-1003P-XX NTLV-1503P-XX NT-3PS-XX NT-4PS-XX

Wiring Diagrams: Accessories s, Switches, and Accessories 369616j 14 02.22.16 Cable TV Jack Model: NT-CJ-XX 75 Ohm Cable 75 Ohm Cable Key Ground or isolated ground Wire connector Screw terminal P Protected P NP NP Not protected 6-Conductor Telephone Jack (accepts most 4-conductor jacks) Model: NT-PJ-XX Receptacle Brass NTR-15-XX NTR-20-XX NTR-15-IG-OR-XX Receptacle Jack position Wire color 1 2 3 4 5 Yellow 6 Blue Nickel-plated NTR-20-IG-OR-XX NTR-15-TR-XX NTR-20-TR-XX Tamper-Resistant Dimmable Receptacle (Dual) Tamper-Resistant Dimmable Receptacle (Half) NTR-15-DDTR-XX NTR-20-DDTR-XX NTR-15-HDTR-XX NTR-20-HDTR-XX Lutron Dimming Product Lutron Dimming Product Dimmed Output Dimmed Output Receptacle Receptacle Tamper Resistant, Self-Testing GFCI Receptacle Ground or Bare or Bare or Bare NP NP NP P P P Receptacle GFCI Receptacle Receptacle Load NTR-15-GFST-XX NTR-20-GFST-XX

Wiring Diagrams: NTF- s s, Switches, and Accessories 369616j 15 02.22.16 Single-Pole NTF-10-XX NTF-10-277-XX Single-Pole Blue Yellow or Orange Orange or Brown a b Orange or Brown a b To additional ballasts b Yellow or Orange Orange or Brown a Violet or Blue (capped) Key Ground Wire connector Typical 4-wire connection a Yellow/Blue or Yellow/ wire when used with magnetic dimming ballasts b Must use lamp disconnect sockets with magnetic dimming ballasts 1 Wire or brass/ gold screw terminal* 2 Wire or green screw terminal* 3 Wire or copper/ black screw terminal* * s have wires; switches have screw terminals b Orange or Brown a Load Side To additional ballasts 3 Switch Blue Violet or Blue Yellow or Orange b Orange or Brown a 2 b Orange or Brown a NTF-103P-XX NTF-103P-277-XX To additional ballasts

Wiring Diagrams: NTFTU- s s, Switches, and Accessories 369616j 16 02.22.16 Single-Pole or Bare Model: NTFTU-5A-XX Key Ground Wire connector 1 Wire or brass/ gold screw terminal* 2 Wire or green screw terminal* 3 Wire or copper/ black screw terminal* * s have wires; switches have screw terminals or Bare Model: NTFTU-5A-277-XX Single-Pole Blue Yellow Blue (capped) Load Side 3 Blue Yellow Switch Blue 2 Model: NTFTU-103P-277-XX-CPW0196

s, Switches, and Accessories 369616j 17 02.22.16 Wiring Diagrams: NTSTV- s The total 0 10 V- control signal wiring for this control should not exceed 500 ft (152.4 m). Do not use wire smaller than 20 AWG (0.75 mm 2 ). For Class 1 installations, 0 10 V- wires must be run in conduit or approved cable per NEC or local jurisdiction. For Class 2 installations, conduit is typically not required (local code may apply). For application with excessive electrical noise, 0 10 V- wires should be run in separate conduit from the mains. Class 1 Installation 120 277 V~ Model: NTSTV-DV-XX Violet (+) Gray ( ) Violet (+) Violet (+) Gray ( ) Gray ( ) Class 1 0 10 V- Signal Wires a Class 2 Installation ON/OFF control using Power Pack (PP-DV or PP-347H) To additional ballasts 0 10 V- or LED Driver 0 10 V- or LED Driver Maximum Capacity * Load 0 10 V- Sink 8 A 30 ma * Whichever comes first. Key Ground Wire connector Wire connector Typical 4-wire connection a Do NOT connect to line voltage b 18 AWG (1.0 mm 2 ) red wires are interchangeable. Connect to either line or load side c wire may be capped for Class 2 installations ONLY Notice Lutron is not liable for damage due to miswiring 0 10 V- control signal wires with line voltage. Do not run Class 2 wires and line voltage conductors together in the same conduit. b b IEC PELV/NEC Class 2 wiring: 20 AWG (0.75 mm 2 ) a Blue Power Pack (capped) Violet (+) Gray ( ) Violet (+) Violet (+) Gray ( ) Gray ( ) 0 10 V- or LED Driver 0 10 V- or LED Driver c Model: NTSTV-DV-XX Class 2 0 10 V- Signal Wires a To additional ballasts Maximum Capacity Load 0 10 V- Sink ** 30 ma ** See PP- and UPP-Series Power Packs spec submittal, Lutron P/N 369544

Wiring Diagrams: NTCL- s s, Switches, and Accessories 369616j 18 02.22.16 Hi-lume A-Series LTE LED Driver Installation Hot NTCL-250 Dimmed Hot () +V () b Ground a () Hi-lume A-Series LED Dimming Driver V (/) b LED Light Engine Ground () a Model: NTCL-250-XX Ground a Key Ground Wire connector a Enclosure and junction box must be grounded in accordance with local and national electrical codes. Ground provided by grounding of junction box or by using the green ground wire connection b For maximum driver-to-led light engine wire length, see Hi-lume A-Series Constant Voltage Driver spec submittal (P/N 369789)